Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
I36153284.B19900447
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). February 15,2019 Liu, Xuegang Pages or sheets covered by this seal: I36153284 thru I36153371 My license renewal date for the state of Indiana is July 31, 2020. B19900447 Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. IMPORTANT NOTE: McKenzie 284 Westvale 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss AT01 Truss Type Attic Qty 3 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153284 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 16:31:08 2019 Page 1 ID:taVjvtMRPLbonO6z99JG03zlGUH-nbvkJTwequhxHN8ANG_duogOTlafW?EMql0bH6zlA3H Scale = 1:70.9 1 2 3 4 5 6 7 8 13 12 11 10 9 1514 8x8 6x6 6x8 3x4 3x6 4x8 10x16 8x10 4x10 10x10 3x4 5x6 8x8 8x10 6x16 7-4-12 7-4-12 15-5-10 8-0-14 24-5-14 9-0-4 32-0-0 7-6-2 7-4-12 7-4-12 14-6-0 7-1-4 15-5-10 0-11-10 17-6-5 2-0-11 24-5-14 6-11-9 25-1-11 0-7-13 32-0-0 6-10-5 4-2-98-11-1112-0-05-1-1112-0-03.94 12 12.00 12 Plate Offsets (X,Y)-- [4:0-5-0,Edge], [5:0-3-8,0-3-0], [6:0-3-8,0-2-0], [7:0-5-8,0-3-0], [8:0-5-0,Edge], [10:0-3-12,0-5-0], [11:0-7-0,0-5-0], [12:0-3-8,0-2-0], [14:0-3-8,0-3-0], [15:0-8-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.91 0.80 0.93 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.36 -0.63 0.04 0.10 (loc) 11-12 11-12 9 11-12 l/defl >999 >605 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 252 lb FT = 20% GRIP 137/123 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x6 SPF No.2 *Except* 10-11: onCENTER® AFL 2.1E 1 1/2" x 11 7/8" WEBS 2x4 SPF No.2 *Except* 2-12,1-13,8-9,5-14,6-14,7-15: 2x4 SPF-S Stud 8-15: 2x4 SPF 2100F 1.8E BRACING- TOP CHORD Sheathed or 4-5-7 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-7. BOT CHORD Rigid ceiling directly applied or 9-9-10 oc bracing. WEBS 1 Row at midpt 3-11, 10-15, 14-15, 8-9, 8-15 JOINTS 1 Brace at Jt(s): 14, 15 REACTIONS.(lb/size)13=1779/0-3-8, 9=1934/0-3-8 Max Horz 13=269(LC 5) Max Uplift 13=-11(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1997/37, 2-3=-2160/0, 3-4=-2540/23, 6-7=-63/1550, 7-8=-136/1910, 1-13=-1756/38, 8-9=-1944/0 BOT CHORD 11-12=-63/1861, 10-11=0/1826 WEBS 2-12=-680/72, 2-11=0/300, 3-11=-1350/84, 4-11=-30/1893, 10-15=-469/161, 6-15=-1583/277, 4-14=-1734/11, 14-15=-3281/6, 1-12=0/2076, 6-14=-78/1693, 8-10=0/2111, 8-15=-3607/0, 7-15=-954/98 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) The Fabrication Tolerance at joint 15 = 16% 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Ceiling dead load (5.0 psf) on member(s). 4-14, 14-15; Wall dead load (5.0psf) on member(s).4-11, 10-15 8) Bottom chord live load (40.0 psf) and additional bottom chord dead load (10.0 psf) applied only to room. 10-11 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 12) Attic room checked for L/360 deflection. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss CG01 Truss Type Diagonal Hip Girder Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153285 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:03 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-uskKUBRkoazi5na4hGzvAKge8VSODPmrqIOtXMzlBkE Scale: 1/4"=1' 1 2 3 5 4 6 7 8 9 3x6 8x8 3x4 4x6 8-4-5 8-4-5 -2-0-1 2-0-1 8-4-5 8-4-5 2-5-118-4-108-1-20-3-88-4-108.49 12 Plate Offsets (X,Y)-- [2:0-3-8,0-4-0] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.89 0.53 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.15 -0.00 0.26 (loc) 4-5 4-5 4 4-5 l/defl >999 >639 n/a >376 L/d 360 240 n/a 240 PLATES MT20 Weight: 55 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 8-3-12 oc bracing. WEBS 1 Row at midpt 3-4, 2-4 REACTIONS.(lb/size)5=614/0-4-9, 4=414/0-1-8 Max Horz 5=274(LC 5) Max Uplift 5=-323(LC 5), 4=-473(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-522/49, 3-4=-298/168 BOT CHORD 4-5=-389/114 WEBS 2-4=-105/387 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 323 lb uplift at joint 5 and 473 lb uplift at joint 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 66 lb down and 20 lb up at 2-9-8, 66 lb down and 20 lb up at 2-9-8, and 63 lb down and 92 lb up at 5-7-7, and 63 lb down and 92 lb up at 5-7-7 on top chord, and 4 lb down and 176 lb up at 2-9-8, 4 lb down and 176 lb up at 2-9-8, and 20 lb down and 114 lb up at 5-7-7, and 20 lb down and 114 lb up at 5-7-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-80, 2-3=-80, 4-5=-20 Concentrated Loads (lb) Vert: 7=-29(F=-14, B=-14) 9=-20(F=-10, B=-10) February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss CG02 Truss Type Diagonal Hip Girder Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153286 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:04 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-M3IiiXSMZu5Zjx9GE_U8iXCpuuocys0_3y8R4ozlBkD Scale = 1:46.4 1 2 3 5 4 6 7 8 9 3x6 8x8 3x4 4x6 8-4-5 8-4-5 -2-0-1 2-0-1 8-4-5 8-4-5 2-5-118-4-108-1-20-3-88-4-108.49 12 Plate Offsets (X,Y)-- [2:0-3-8,0-4-0] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.89 0.53 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.15 -0.00 0.26 (loc) 4-5 4-5 4 4-5 l/defl >999 >639 n/a >376 L/d 360 240 n/a 240 PLATES MT20 Weight: 55 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 8-3-12 oc bracing. WEBS 1 Row at midpt 3-4, 2-4 REACTIONS.(lb/size)5=614/0-4-9, 4=414/0-1-8 Max Horz 5=274(LC 5) Max Uplift 5=-323(LC 5), 4=-473(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-522/49, 3-4=-298/168 BOT CHORD 4-5=-389/114 WEBS 2-4=-105/387 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 323 lb uplift at joint 5 and 473 lb uplift at joint 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 66 lb down and 20 lb up at 2-9-8, 66 lb down and 20 lb up at 2-9-8, and 63 lb down and 92 lb up at 5-7-7, and 63 lb down and 92 lb up at 5-7-7 on top chord, and 4 lb down and 176 lb up at 2-9-8, 4 lb down and 176 lb up at 2-9-8, and 20 lb down and 114 lb up at 5-7-7, and 20 lb down and 114 lb up at 5-7-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-80, 2-3=-80, 4-5=-20 Concentrated Loads (lb) Vert: 7=-29(F=-14, B=-14) 9=-20(F=-10, B=-10) February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss CG03 Truss Type Diagonal Hip Girder Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153287 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:06 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-IRQT7DUc4VLGyFJfMPWcoyIFpiVLQnyHWGdX8hzlBkB Scale = 1:43.4 1 2 3 5 4 6 7 8 9 3x4 6x6 2x4 4x6 7-0-12 7-0-12 -2-0-1 2-0-1 7-0-12 7-0-12 2-5-117-5-107-2-20-3-87-5-108.49 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.48 0.39 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.03 -0.07 -0.00 0.13 (loc) 4-5 4-5 4 4-5 l/defl >999 >999 n/a >643 L/d 360 240 n/a 240 PLATES MT20 Weight: 47 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=473/0-4-9, 4=296/0-1-8 Max Horz 5=246(LC 12) Max Uplift 5=-417(LC 3), 4=-376(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-402/129 BOT CHORD 4-5=-311/45 WEBS 2-4=-41/314 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 417 lb uplift at joint 5 and 376 lb uplift at joint 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 44 lb down and 164 lb up at 1-5-15, 44 lb down and 164 lb up at 1-5-15, and 61 lb down and 57 lb up at 4-3-14, and 61 lb down and 57 lb up at 4-3-14 on top chord, and 10 lb down and 134 lb up at 1-5-15, 10 lb down and 134 lb up at 1-5-15, and 5 lb down and 136 lb up at 4-3-14, and 5 lb down and 136 lb up at 4-3-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-80, 2-3=-80, 4-5=-20 Concentrated Loads (lb) Vert: 6=82(F=41, B=41) 9=-2(F=-1, B=-1) February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss CG04 Truss Type Diagonal Hip Girder Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153288 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:07 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-mdzrKZUErpU7aOurw62rKAqSJ6wO9E6RlwM5g7zlBkA Scale = 1:27.7 1 2 5 67 8 3 9 43x4 5x8 6x6 -1-11-1 1-11-1 4-1-1 4-1-1 2-3-71-0-114-10-140-7-17.68 12 Plate Offsets (X,Y)-- [2:0-5-4,0-1-8], [6:0-3-0,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.37 0.08 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 -0.00 -0.02 0.01 (loc) 5 4-5 3 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 26 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x8 SP 2400F 2.0E BRACING- TOP CHORD Structural wood sheathing directly applied or 4-1-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=96/Mechanical, 4=40/Mechanical, 7=368/0-4-9 Max Horz 7=144(LC 5) Max Uplift 3=-89(LC 5), 4=-22(LC 5), 7=-165(LC 5) Max Grav 3=96(LC 1), 4=62(LC 2), 7=368(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-7=-349/105 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 89 lb uplift at joint 3, 22 lb uplift at joint 4 and 165 lb uplift at joint 7. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 40 lb down and 138 lb up at 0-11-14, and 158 lb up at 1-6-3 on top chord, and 12 lb down and 46 lb up at 0-9-0, and 22 lb down and 78 lb up at 1-6-3 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-80, 2-3=-80, 4-5=-20 Concentrated Loads (lb) Vert: 5=-12(B) 2=33(B) 8=39(F) 9=-22(F) February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss CG05 Truss Type Diagonal Hip Girder Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153289 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:08 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-EqXDXvVsc7c_CYT2TpZ4tNNfvW3YufKa_a6eDazlBk9 Scale = 1:44.2 1 2 6 5 7 3 8 4 2x4 4x6 2x4 1-6-0 1-6-0 5-7-2 4-1-2 -2-0-1 2-0-1 5-7-2 5-7-2 3-6-137-6-56-10-87-6-48.49 12 Plate Offsets (X,Y)-- [2:0-2-14,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.25 0.92 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.03 -0.31 0.18 (loc) 4-5 4-5 3 4-5 l/defl >999 >999 n/a >368 L/d 360 240 n/a 240 PLATES MT20 Weight: 33 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 4-2-10 oc bracing. REACTIONS.(lb/size)6=476/0-7-6, 3=181/Mechanical, 4=54/Mechanical Max Horz 6=232(LC 5) Max Uplift 6=-277(LC 3), 3=-72(LC 5), 4=-390(LC 5) Max Grav 6=476(LC 1), 3=181(LC 1), 4=108(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-422/20 WEBS 2-5=-37/497 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed; porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 277 lb uplift at joint 6, 72 lb uplift at joint 3 and 390 lb uplift at joint 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 66 lb down and 20 lb up at 2-9-8, and 66 lb down and 20 lb up at 2-9-8 on top chord, and 48 lb down and 252 lb up at 2-9-8, and 30 lb down and 268 lb up at 2-9-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-80, 2-3=-80, 4-6=-20 February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss CG06 Truss Type Diagonal Hip Girder Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153290 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:09 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-i05blFWVNQkrpi2E1X4JPbwi7vVwd8PjCErCl0zlBk8 Scale = 1:47.3 1 2 3 5 4 6 7 8 9 3x6 8x8 3x4 4x6 8-11-12 8-11-12 -2-0-1 2-0-1 8-11-12 8-11-12 2-5-118-9-148-6-60-3-88-9-148.49 12 Plate Offsets (X,Y)-- [2:0-3-8,0-4-0] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.73 0.52 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.08 -0.20 -0.00 0.29 (loc) 4-5 4-5 4 4-5 l/defl >999 >513 n/a >359 L/d 360 240 n/a 240 PLATES MT20 Weight: 60 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 8-0-4 oc bracing. WEBS 1 Row at midpt 3-4, 2-4 REACTIONS.(lb/size)5=657/0-4-9, 4=482/0-1-8 Max Horz 5=287(LC 5) Max Uplift 5=-276(LC 5), 4=-498(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-555/56, 2-3=-255/146, 3-4=-342/196 BOT CHORD 4-5=-445/180 WEBS 2-4=-171/443 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 276 lb uplift at joint 5 and 498 lb uplift at joint 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 62 lb down and 34 lb up at 3-4-15, 62 lb down and 34 lb up at 3-4-15, and 67 lb down and 105 lb up at 6-2-14, and 67 lb down and 105 lb up at 6-2-14 on top chord, and 4 lb down and 155 lb up at 3-4-15, 4 lb down and 155 lb up at 3-4-15, and 29 lb down and 107 lb up at 6-2-14, and 29 lb down and 107 lb up at 6-2-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-80, 2-3=-80, 4-5=-20 Concentrated Loads (lb) Vert: 7=-69(F=-35, B=-35) 9=-29(F=-14, B=-14) February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss GE01 Truss Type Monopitch Supported Gable Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153291 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:10 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-BCf_ybX78ksiRsdQbEbYyoS?rJz5MaLtRublHSzlBk7 Scale = 1:30.8 1 2 3 5 4 2x4 3x6 2x4 3x4 -1-5-0 1-5-0 1-7-8 1-7-8 3-9-115-5-312.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.22 0.02 0.16 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 -0.01 -0.00 0.01 (loc) 1 1 4 1 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-7-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=212/1-7-8, 4=-5/1-7-8 Max Horz 5=132(LC 6) Max Uplift 5=-21(LC 4), 4=-261(LC 6) Max Grav 5=214(LC 6), 4=49(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-284/27 WEBS 2-4=-27/413 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 21 lb uplift at joint 5 and 261 lb uplift at joint 4. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J01 Truss Type Jack-Open Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153292 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:12 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-7bnkNGYNgL6QgAmpifd01DXFo7arqWNAvC4sMLzlBk5 Scale = 1:21.4 1 2 5 3 4 3x6 3x6 1-1-7 1-1-7 -1-5-0 1-5-0 1-1-7 1-1-7 2-5-113-7-23-0-113-7-212.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.64 0.32 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.00 -0.05 0.00 (loc) 5 5 3 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-1-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=275/0-3-8, 3=-51/Mechanical, 4=-3/Mechanical Max Horz 5=132(LC 6) Max Uplift 5=-5(LC 4), 3=-65(LC 6), 4=-130(LC 6) Max Grav 5=275(LC 1), 3=17(LC 4), 4=16(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-253/3 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 5 lb uplift at joint 5, 65 lb uplift at joint 3 and 130 lb uplift at joint 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J02 Truss Type Jack-Open Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153293 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:12 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-7bnkNGYNgL6QgAmpifd01DXKU7Y5qUyAvC4sMLzlBk5 Scale = 1:31.4 1 2 6 5 3 4 2x4 3x6 2x4 1-6-0 1-6-0 3-1-7 1-7-7 -1-5-0 1-5-0 3-1-7 3-1-7 2-5-115-7-25-0-115-7-212.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.28 0.43 0.16 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.01 -0.06 0.03 (loc) 5 5 3 5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=304/0-3-8, 3=83/Mechanical, 4=29/Mechanical Max Horz 6=193(LC 6) Max Uplift 3=-41(LC 6), 4=-119(LC 6) Max Grav 6=304(LC 1), 3=83(LC 1), 4=58(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-275/0 WEBS 2-5=-11/396 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 41 lb uplift at joint 3 and 119 lb uplift at joint 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J03 Truss Type Jack-Open Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153294 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:14 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-3_vUoyadCzM8wTwBq4gU6edgzwIwIOsTMWZzQDzlBk3 Scale = 1:26.0 1 2 6 5 3 4 2x4 3x6 2x4 1-6-0 1-6-0 2-0-7 0-6-7 -1-5-0 1-5-0 2-0-7 2-0-7 2-5-114-6-23-11-114-6-212.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.28 0.15 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 -0.01 0.00 (loc) 6 5 3 5-6 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=270/0-3-8, 3=20/Mechanical, 4=18/Mechanical Max Horz 6=159(LC 6) Max Uplift 3=-14(LC 7), 4=-165(LC 6) Max Grav 6=270(LC 1), 3=24(LC 4), 4=37(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-252/1 WEBS 2-5=-6/327 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 14 lb uplift at joint 3 and 165 lb uplift at joint 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J04 Truss Type Jack-Open Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153295 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:16 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-?M0FDebukacs9n4axViyC3i0TktImIalpq23V6zlBk1 Scale = 1:35.9 1 2 6 5 3 4 2x4 3x6 2x4 1-6-0 1-6-0 4-0-7 2-6-7 -1-5-0 1-5-0 4-0-7 4-0-7 2-5-116-6-25-11-116-6-212.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.28 0.61 0.18 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.03 -0.13 0.08 (loc) 5 4-5 3 4-5 l/defl >999 >999 n/a >578 L/d 360 240 n/a 240 PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-0-15 oc bracing. REACTIONS.(lb/size)6=342/0-3-8, 3=128/Mechanical, 4=38/Mechanical Max Horz 6=221(LC 6) Max Uplift 3=-71(LC 6), 4=-97(LC 6) Max Grav 6=342(LC 1), 3=128(LC 1), 4=77(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-320/0 WEBS 2-5=-15/454 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 71 lb uplift at joint 3 and 97 lb uplift at joint 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J05 Truss Type Jack-Open Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153296 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:16 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-?M0FDebukacs9n4axViyC3ixnkynmKMlpq23V6zlBk1 Scale = 1:21.4 1 2 5 3 4 3x6 3x6 1-1-7 1-1-7 -1-5-0 1-5-0 1-1-7 1-1-7 2-5-113-7-23-0-113-7-212.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.64 0.32 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.00 -0.05 0.00 (loc) 5 5 3 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-1-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=275/0-3-8, 3=-51/Mechanical, 4=-3/Mechanical Max Horz 5=132(LC 6) Max Uplift 5=-5(LC 4), 3=-65(LC 6), 4=-130(LC 6) Max Grav 5=275(LC 1), 3=17(LC 4), 4=16(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-253/3 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 5 lb uplift at joint 5, 65 lb uplift at joint 3 and 130 lb uplift at joint 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J06 Truss Type Jack-Open Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153297 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:17 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-TZadQ_cWVukinxfmVCDBkHFBD8GGVlBv2Uod1YzlBk0 Scale = 1:31.4 1 2 6 5 3 4 2x4 3x6 2x4 1-6-0 1-6-0 3-1-7 1-7-7 -1-5-0 1-5-0 3-1-7 3-1-7 2-5-115-7-25-0-115-7-212.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.28 0.43 0.16 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.01 -0.06 0.03 (loc) 5 5 3 5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=304/0-3-8, 3=83/Mechanical, 4=29/Mechanical Max Horz 6=193(LC 6) Max Uplift 3=-41(LC 6), 4=-119(LC 6) Max Grav 6=304(LC 1), 3=83(LC 1), 4=58(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-275/0 WEBS 2-5=-11/396 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 41 lb uplift at joint 3 and 119 lb uplift at joint 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J07 Truss Type Jack-Open Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153298 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:18 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-yl8?eKd8GBsZO5Ez3wkQHUnMzYgsEBs2H7XAZ?zlBk? Scale = 1:26.0 1 2 6 5 3 4 2x4 3x6 2x4 1-6-0 1-6-0 2-0-7 0-6-7 -1-5-0 1-5-0 2-0-7 2-0-7 2-5-114-6-23-11-114-6-212.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.28 0.15 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 -0.01 0.00 (loc) 6 5 3 5-6 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=270/0-3-8, 3=20/Mechanical, 4=18/Mechanical Max Horz 6=159(LC 6) Max Uplift 3=-14(LC 7), 4=-165(LC 6) Max Grav 6=270(LC 1), 3=24(LC 4), 4=37(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-252/1 WEBS 2-5=-6/327 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 14 lb uplift at joint 3 and 165 lb uplift at joint 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J08 Truss Type Jack-Open Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153299 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:18 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-yl8?eKd8GBsZO5Ez3wkQHUnMzYZmEB42H7XAZ?zlBk? Scale = 1:35.9 1 2 6 5 3 4 2x4 3x6 2x4 1-6-0 1-6-0 4-0-7 2-6-7 -1-5-0 1-5-0 4-0-7 4-0-7 2-5-116-6-25-11-116-6-212.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.28 0.61 0.18 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.03 -0.13 0.08 (loc) 5 4-5 3 4-5 l/defl >999 >999 n/a >578 L/d 360 240 n/a 240 PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-0-15 oc bracing. REACTIONS.(lb/size)6=342/0-3-8, 3=128/Mechanical, 4=38/Mechanical Max Horz 6=221(LC 6) Max Uplift 3=-71(LC 6), 4=-97(LC 6) Max Grav 6=342(LC 1), 3=128(LC 1), 4=77(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-320/0 WEBS 2-5=-15/454 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 71 lb uplift at joint 3 and 97 lb uplift at joint 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J09 Truss Type Jack-Open Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153300 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:19 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-QxiNrgem0V_Q0Ep9ddFfpiKW9x09zevCWnHj5RzlBk_ Scale = 1:19.9 1 2 5 6 7 3 4 2x4 5x8 3x4 -1-2-12 1-2-12 1-0-4 1-0-4 2-3-71-0-113-3-110-7-12-9-43-3-1112.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.31 0.08 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 -0.01 0.00 (loc) 5 5 3 5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-0-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=-54/Mechanical, 4=36/Mechanical, 7=208/0-3-8 Max Horz 7=97(LC 6) Max Uplift 3=-54(LC 1), 4=-69(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 3 and 69 lb uplift at joint 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J10 Truss Type Jack-Open Qty 9 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153301 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:19 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-QxiNrgem0V_Q0Ep9ddFfpiKUWx_Sze8CWnHj5RzlBk_ Scale = 1:28.2 1 2 5 6 7 3 43x4 5x6 3x4 -1-2-12 1-2-12 2-8-0 2-8-0 2-3-71-0-114-11-70-7-14-5-04-11-712.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.42 0.19 0.19 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 -0.05 0.01 (loc) 4-5 4-5 3 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-8-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=64/Mechanical, 4=28/Mechanical, 7=258/0-3-8 Max Horz 7=146(LC 6) Max Uplift 3=-81(LC 6), 4=-30(LC 6) Max Grav 3=64(LC 1), 4=45(LC 2), 7=258(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 81 lb uplift at joint 3 and 30 lb uplift at joint 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J11 Truss Type Jack-Open Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153302 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:19 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-QxiNrgem0V_Q0Ep9ddFfpiKW9x09zevCWnHj5RzlBk_ Scale = 1:19.9 1 2 5 6 7 3 4 2x4 5x8 3x4 -1-2-12 1-2-12 1-0-4 1-0-4 2-3-71-0-113-3-110-7-12-9-43-3-1112.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.31 0.08 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 -0.01 0.00 (loc) 5 5 3 5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-0-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=-54/Mechanical, 4=36/Mechanical, 7=208/0-3-8 Max Horz 7=97(LC 6) Max Uplift 3=-54(LC 1), 4=-69(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 3 and 69 lb uplift at joint 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J12 Truss Type Jack-Open Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153303 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:20 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-u8Gm3?fOnp6HeOOLALmuMvthSLNmi6dLkR0HdtzlBjz Scale = 1:18.2 1 2 5 6 7 3 4 2x4 5x6 3x4 -1-1-9 1-1-9 1-2-10 1-2-10 1-11-121-0-72-11-150-7-12-6-22-11-1510.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.28 0.06 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 -0.01 0.00 (loc) 5 5 3 5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-2-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=-13/Mechanical, 4=25/Mechanical, 7=191/0-3-8 Max Horz 7=83(LC 6) Max Uplift 3=-33(LC 6), 4=-38(LC 6) Max Grav 3=2(LC 4), 4=25(LC 1), 7=191(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 33 lb uplift at joint 3 and 38 lb uplift at joint 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J13 Truss Type Jack-Open Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153304 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:20 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-u8Gm3?fOnp6HeOOLALmuMvthSLNmi6dLkR0HdtzlBjz Scale = 1:18.2 1 2 5 6 7 3 4 2x4 5x6 3x4 -1-1-9 1-1-9 1-2-10 1-2-10 1-11-121-0-72-11-150-7-12-6-22-11-1510.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.28 0.06 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 -0.01 0.00 (loc) 5 5 3 5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-2-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=-13/Mechanical, 4=25/Mechanical, 7=191/0-3-8 Max Horz 7=83(LC 6) Max Uplift 3=-33(LC 6), 4=-38(LC 6) Max Grav 3=2(LC 4), 4=25(LC 1), 7=191(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 33 lb uplift at joint 3 and 38 lb uplift at joint 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J15 Truss Type Jack-Open Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153305 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:21 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-MKq8GLf0Y6E8FYyYk2I7v7PsClfLRXYUz5mq9JzlBjy Scale = 1:31.7 1 2 6 5 3 4 2x4 3x6 2x4 1-6-0 1-6-0 2-0-7 0-6-7 -1-5-0 1-5-0 2-0-7 2-0-7 3-6-135-7-45-0-135-7-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.28 0.29 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 -0.03 0.01 (loc) 6 5 3 5-6 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=270/0-5-8, 3=20/Mechanical, 4=18/Mechanical Max Horz 6=176(LC 6) Max Uplift 6=-24(LC 4), 3=-14(LC 7), 4=-280(LC 6) Max Grav 6=270(LC 1), 3=24(LC 4), 4=37(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-354/23 WEBS 2-5=-29/498 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 24 lb uplift at joint 6, 14 lb uplift at joint 3 and 280 lb uplift at joint 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J16 Truss Type Jack-Open Qty 3 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153306 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:21 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-MKq8GLf0Y6E8FYyYk2I7v7PsClZ0RWUUz5mq9JzlBjy Scale = 1:41.3 1 2 6 5 3 4 2x4 3x6 2x4 1-6-0 1-6-0 4-0-0 2-6-0 -1-5-0 1-5-0 4-0-0 4-0-0 3-6-137-6-137-0-67-6-1312.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.28 0.70 0.26 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.02 -0.25 0.10 (loc) 5 4-5 3 4-5 l/defl >999 >999 n/a >448 L/d 360 240 n/a 240 PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=340/0-5-8, 3=126/Mechanical, 4=38/Mechanical Max Horz 6=237(LC 6) Max Uplift 6=-10(LC 4), 3=-70(LC 6), 4=-196(LC 6) Max Grav 6=340(LC 1), 3=126(LC 1), 4=76(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-555/20 BOT CHORD 5-6=-260/16 WEBS 2-5=-42/671 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 10 lb uplift at joint 6, 70 lb uplift at joint 3 and 196 lb uplift at joint 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J17 Truss Type Jack-Open Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153307 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:22 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-qWNWUhgeJQM?tiXkImpMRKy1y9?xA_oeClVOhmzlBjx Scale = 1:31.7 1 2 6 5 3 4 2x4 3x6 2x4 1-6-0 1-6-0 2-0-7 0-6-7 -1-5-0 1-5-0 2-0-7 2-0-7 3-6-135-7-45-0-135-7-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.28 0.27 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 -0.03 0.01 (loc) 6 5 3 5-6 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=270/0-5-8, 3=20/Mechanical, 4=18/Mechanical Max Horz 6=176(LC 6) Max Uplift 6=-6(LC 4), 3=-14(LC 7), 4=-265(LC 6) Max Grav 6=270(LC 1), 3=24(LC 4), 4=37(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-354/23 WEBS 2-5=-29/498 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 6 lb uplift at joint 6, 14 lb uplift at joint 3 and 265 lb uplift at joint 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J18 Truss Type Jack-Open Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153308 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:22 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-qWNWUhgeJQM?tiXkImpMRKy1y9?nA?geClVOhmzlBjx Scale = 1:28.2 1 2 6 5 3 4 2x4 3x6 2x4 1-6-0 1-6-0 2-5-11 0-11-11 -1-5-0 1-5-0 2-5-11 2-5-11 2-5-114-11-64-4-154-11-612.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.28 0.28 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 -0.02 0.01 (loc) 5 5 3 5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-5-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=281/0-3-8, 3=48/Mechanical, 4=23/Mechanical Max Horz 6=173(LC 6) Max Uplift 3=-23(LC 7), 4=-142(LC 6) Max Grav 6=281(LC 1), 3=48(LC 1), 4=45(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-259/0 WEBS 2-5=-8/355 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 23 lb uplift at joint 3 and 142 lb uplift at joint 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J19 Truss Type Jack-Open Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153309 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:22 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-qWNWUhgeJQM?tiXkImpMRKy0j9vYA?ueClVOhmzlBjx Scale = 1:38.0 1 2 6 5 3 42x4 3x6 2x4 1-6-0 1-6-0 4-5-11 2-11-11 -1-5-0 1-5-0 4-5-11 4-5-11 2-5-116-11-66-4-156-11-612.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.35 0.68 0.19 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.02 -0.05 -0.17 0.11 (loc) 4-5 4-5 3 4-5 l/defl >999 >999 n/a >464 L/d 360 240 n/a 240 PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 8-5-2 oc bracing. REACTIONS.(lb/size)6=361/0-3-8, 3=148/Mechanical, 4=43/Mechanical Max Horz 6=235(LC 6) Max Uplift 3=-85(LC 6), 4=-90(LC 6) Max Grav 6=361(LC 1), 3=148(LC 1), 4=85(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-349/0 BOT CHORD 5-6=-258/9 WEBS 2-5=-17/482 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 85 lb uplift at joint 3 and 90 lb uplift at joint 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J20 Truss Type Jack-Open Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153310 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:23 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-Iixuh1hH4kVsVs6wsTKb_YVBTZFnvS8nQPFxECzlBjw Scale = 1:38.0 1 2 6 5 3 42x4 3x6 2x4 1-6-0 1-6-0 4-5-11 2-11-11 -1-5-0 1-5-0 4-5-11 4-5-11 2-5-116-11-66-4-156-11-612.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.35 0.68 0.19 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.02 -0.05 -0.17 0.11 (loc) 4-5 4-5 3 4-5 l/defl >999 >999 n/a >464 L/d 360 240 n/a 240 PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 8-5-2 oc bracing. REACTIONS.(lb/size)6=361/0-3-8, 3=148/Mechanical, 4=43/Mechanical Max Horz 6=235(LC 6) Max Uplift 3=-85(LC 6), 4=-90(LC 6) Max Grav 6=361(LC 1), 3=148(LC 1), 4=85(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-349/0 BOT CHORD 5-6=-258/9 WEBS 2-5=-17/482 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 85 lb uplift at joint 3 and 90 lb uplift at joint 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss J21 Truss Type Jack-Open Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153311 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:23 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-Iixuh1hH4kVsVs6wsTKb_YVCiZL0vSwnQPFxECzlBjw Scale = 1:28.2 1 2 6 5 3 4 2x4 3x6 2x4 1-6-0 1-6-0 2-5-11 0-11-11 -1-5-0 1-5-0 2-5-11 2-5-11 2-5-114-11-612.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.28 0.28 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 -0.02 0.01 (loc) 5 5 3 5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-5-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=281/0-3-8, 3=48/Mechanical, 4=23/Mechanical Max Horz 6=173(LC 6) Max Uplift 3=-23(LC 7), 4=-142(LC 6) Max Grav 6=281(LC 1), 3=48(LC 1), 4=45(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-259/0 WEBS 2-5=-8/355 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 23 lb uplift at joint 3 and 142 lb uplift at joint 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss M01 Truss Type MONOPITCH Qty 12 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153312 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:24 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-mvVGuNivr1dj60h6PArqWl1L?yhbewTxf3_UmezlBjv Scale = 1:44.8 1 2 3 5 4 2x4 2x4 3x6 3x4 -1-5-0 1-5-0 5-2-0 5-2-0 2-5-117-7-117-4-30-3-87-7-1112.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.43 0.26 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.03 -0.08 -0.00 0.00 (loc) 4-5 4-5 4 5 l/defl >999 >691 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 30 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=389/0-3-8, 4=224/0-1-8 Max Horz 5=253(LC 6) Max Uplift 4=-183(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-340/0 BOT CHORD 4-5=-279/11 WEBS 2-4=-12/307 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 183 lb uplift at joint 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss M02 Truss Type Monopitch Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153313 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:24 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-mvVGuNivr1dj60h6PArqWl1KJyhLewUxf3_UmezlBjv Scale = 1:41.7 1 2 3 5 4 2x4 2x4 3x6 3x4 5-1-0 5-1-0 -1-5-0 1-5-0 5-1-0 5-1-0 2-5-117-6-117-3-30-3-87-6-1112.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.48 0.27 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.03 -0.08 -0.00 0.00 (loc) 4-5 4-5 4 5 l/defl >999 >727 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 30 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=385/0-3-8, 4=219/0-1-8 Max Horz 5=251(LC 6) Max Uplift 4=-182(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-337/0 BOT CHORD 4-5=-276/11 WEBS 2-4=-12/305 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 182 lb uplift at joint 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss M03 Truss Type Monopitch Qty 4 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153314 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:25 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-E53e6jiXcLlak9GJzuM33zaRBM_nNMa4ujk2I5zlBju Scale: 1/4"=1' 1 2 3 5 4 2x4 2x4 3x6 3x4 -1-5-0 1-5-0 6-0-0 6-0-0 2-5-118-5-118-2-30-3-88-5-1112.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.72 0.39 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.16 -0.00 0.00 (loc) 4-5 4-5 4 5 l/defl >999 >430 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 34 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-4 REACTIONS.(lb/size)5=428/0-3-8, 4=268/0-1-8 Max Horz 5=279(LC 6) Max Uplift 4=-196(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-370/0 BOT CHORD 4-5=-304/13 WEBS 2-4=-14/327 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 196 lb uplift at joint 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss M04 Truss Type MONOPITCH Qty 6 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153315 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:25 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-E53e6jiXcLlak9GJzuM33zaQ2M1RNMO4ujk2I5zlBju Scale = 1:50.0 1 2 3 5 4 3x4 3x4 6x8 4x6 -1-5-0 1-5-0 6-5-4 6-5-4 2-5-118-10-158-7-70-3-88-10-1512.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.80 0.22 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.14 -0.00 -0.01 (loc) 4-5 4-5 4 4-5 l/defl >999 >529 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 38 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-4: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-10-6 oc bracing. WEBS 1 Row at midpt 3-4 REACTIONS.(lb/size)5=448/0-3-8, 4=291/0-1-8 Max Horz 5=293(LC 6) Max Uplift 4=-203(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-384/0 BOT CHORD 4-5=-342/86 WEBS 2-4=-78/359 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 203 lb uplift at joint 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss PB01 Truss Type Piggyback Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153316 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:26 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-jHd1J3j9NftRMJrVXbtIbA7kgmOh6rtE7NTbqXzlBjt Scale = 1:15.2 1 2 3 4 56 8 7 5x6 5x6 2x4 2x4 2x4 2x4 7-7-6 7-7-6 7-7-6 7-7-6 0-5-31-4-11-6-30-1-80-5-30-1-81-4-112.00 12 Plate Offsets (X,Y)-- [2:0-2-6,0-1-0], [3:0-3-0,0-1-15], [4:0-3-0,0-1-15], [5:0-2-6,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.23 0.15 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 0.00 0.00 (loc) 5 5 5 5 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 6-6-0. (lb) - Max Horz 2=-27(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 2, 5, 8, 7 Max Grav All reactions 250 lb or less at joint(s) 2, 5 except 8=320(LC 10), 7=320(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5, 8, 7. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss PB02 Truss Type Piggyback Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153317 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:26 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-jHd1J3j9NftRMJrVXbtIbA7mWmPe6r1E7NTbqXzlBjt Scale = 1:21.2 1 2 3 4 56 8 7 4x8 3x4 3x4 2x4 2x4 7-7-6 7-7-6 7-7-6 7-7-6 0-5-33-4-13-6-30-1-80-5-30-1-83-4-112.00 12 Plate Offsets (X,Y)-- [2:0-1-9,0-1-8], [3:0-4-0,0-1-12], [5:0-1-9,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.11 0.09 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.01 0.00 -0.00 (loc) 6 6 5 6 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 25 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 6-6-0. (lb) - Max Horz 2=-73(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 2, 5, 8, 7 Max Grav All reactions 250 lb or less at joint(s) 2, 5, 8, 7 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5, 8, 7. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss PB03 Truss Type Piggyback Qty 16 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153318 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:27 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-BUBPXPkn8y?IzTQh5JPX8OfwzAlNrIGNL1D9NzzlBjs Scale = 1:22.0 1 2 3 45 6 4x6 3x4 3x4 2x4 7-7-6 7-7-6 3-9-11 3-9-11 7-7-6 3-9-11 0-5-33-8-30-1-80-5-30-1-812.00 12 Plate Offsets (X,Y)-- [2:0-1-9,0-1-8], [4:0-1-9,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.13 0.13 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.01 0.00 -0.00 (loc) 5 5 4 5 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=220/6-6-0, 4=220/6-6-0, 6=262/6-6-0 Max Horz 2=78(LC 5) Max Uplift 2=-23(LC 6), 4=-28(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss PB04 Truss Type Piggyback Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153319 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:27 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-BUBPXPkn8y?IzTQh5JPX8OfxpAmjrIjNL1D9NzzlBjs Scale = 1:12.2 1 2 3 4 5 6 4x6 2x4 2x4 2x4 4-9-14 4-9-14 2-4-15 2-4-15 4-9-14 2-4-15 0-4-131-10-100-1-80-4-130-1-810.00 12 Plate Offsets (X,Y)-- [2:0-2-1,0-1-0], [4:0-2-1,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.08 0.04 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.00 0.00 -0.00 (loc) 5 5 4 4 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=141/3-6-12, 4=141/3-6-12, 6=134/3-6-12 Max Horz 2=37(LC 5) Max Uplift 2=-26(LC 6), 4=-29(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss PB05 Truss Type Piggyback Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153320 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:28 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-fglnkllPvG79bd?ue0wmhbC7ma6Cal_WahyivPzlBjr Scale = 1:9.7 1 2 3 4 5 6 8 7 4x6 4x6 2x4 2x4 2x4 2x4 4-9-14 4-9-14 4-9-14 4-9-14 0-4-131-0-131-2-150-1-80-4-130-1-81-0-1310.00 12 Plate Offsets (X,Y)-- [2:0-2-1,0-1-0], [5:0-2-1,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.06 0.02 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.00 0.00 -0.00 (loc) 5 5 5 5 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-14 oc purlins, except 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 3-6-12. (lb) - Max Horz 2=20(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 2, 5, 8, 7 Max Grav All reactions 250 lb or less at joint(s) 2, 5, 8, 7 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5, 8, 7. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T01 Truss Type Hip Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153321 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:28 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-fglnkllPvG79bd?ue0wmhbC19a_maZKWahyivPzlBjr Scale = 1:58.1 1 2 3 4 5 6 7 12 11 10 9 813141516 2x4 5x6 5x6 3x4 3x8 3x6 3x6 3x6 3x6 3x6 2x4 8-0-0 8-0-0 9-0-0 1-0-0 17-0-0 8-0-0 3-6-0 3-6-0 8-0-0 4-6-0 9-0-0 1-0-0 13-6-0 4-6-0 17-0-0 3-6-0 18-5-0 1-5-0 2-5-1110-3-910-5-112-5-1110-3-912.00 12 Plate Offsets (X,Y)-- [3:0-3-9,0-2-8], [4:0-3-9,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.42 0.56 0.77 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.09 -0.24 0.01 0.01 (loc) 8-9 8-9 8 8-9 l/defl >999 >838 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 112 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-10,4-10,4-9: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 REACTIONS.(lb/size)12=916/0-3-8, 8=1053/0-3-8 Max Horz 12=-283(LC 4) Max Uplift 12=-27(LC 7), 8=-54(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-698/168, 3-4=-399/166, 4-5=-693/166, 6-8=-284/195 BOT CHORD 10-12=-126/436, 9-10=-26/397, 8-9=0/422 WEBS 3-10=-83/266, 2-12=-761/29, 5-8=-763/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 8. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T02 Truss Type Common Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153322 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:29 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-7sJ9y4l1gaF?Dna4CkR?DplBJzKrJ13gpLiFRszlBjq Scale = 1:54.6 1 2 3 4 5 6 10 9 8 711121314 3x4 4x6 3x4 3x8 3x6 3x6 3x6 3x6 3x4 8-6-0 8-6-0 17-0-0 8-6-0 3-4-0 3-4-0 8-6-0 5-2-0 13-8-0 5-2-0 17-0-0 3-4-0 18-5-0 1-5-0 2-5-1110-11-112-5-1112.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.46 0.57 0.74 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.10 -0.26 0.01 0.01 (loc) 8-10 7-8 7 7-8 l/defl >999 >775 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 91 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-8: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)10=917/0-3-8, 7=1054/0-3-8 Max Horz 10=-295(LC 4) Max Uplift 10=-33(LC 7), 7=-53(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-703/162, 3-4=-701/161, 5-7=-259/180 BOT CHORD 8-10=-136/437, 7-8=0/423 WEBS 3-8=-112/368, 2-10=-781/46, 4-7=-786/9 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 7. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T03 Truss Type Hip Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153323 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:30 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-b3sX9QmgRtNsrx8GmRyEm0HHuNfQ2T5p2?RpzIzlBjp Scale = 1:54.7 1 2 3 4 5 6 7 13 12 11 10 9 8 14 1516 17 18 19 5x6 5x6 2x4 3x4 3x6 3x12 2x4 3x6 2x4 6x6 6x6 3x4 3x4 5-11-10 5-11-10 13-11-4 7-11-10 21-10-14 7-11-10 27-10-8 5-11-10 -1-1-9 1-1-9 5-11-10 5-11-10 13-11-4 7-11-10 21-10-14 7-11-10 27-10-8 5-11-10 29-0-1 1-1-9 1-11-121-0-76-9-56-11-70-7-11-11-120-7-11-0-76-9-510.00 12 Plate Offsets (X,Y)-- [3:0-3-0,0-2-1], [5:0-3-0,0-2-1] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.79 0.62 0.82 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.12 -0.27 0.05 0.03 (loc) 10-12 10-12 17 10 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 128 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-5: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-10,5-10: 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-4 oc purlins, except end verticals, and 2-0-0 oc purlins (5-0-9 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)16=1608/0-3-8, 17=1608/0-3-8 Max Horz 16=125(LC 5) Max Uplift 16=-56(LC 5), 17=-56(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1588/150, 3-4=-1721/209, 4-5=-1721/209, 5-6=-1588/150 BOT CHORD 12-13=-114/294, 10-12=-112/1117, 9-10=-38/1117, 8-9=-21/294 WEBS 3-10=-150/842, 4-10=-769/232, 5-10=-150/842, 2-12=-55/878, 6-9=-73/878, 2-16=-1642/144, 6-17=-1642/144 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Bearing at joint(s) 16, 17 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 17. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T04 Truss Type Hip Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153324 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:30 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-b3sX9QmgRtNsrx8GmRyEm0HLsNf?2XJp2?RpzIzlBjp Scale = 1:54.5 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 16 1718 19 20 21 22 5x6 5x6 3x6 3x6 5x12 2x4 3x8 2x4 5x12 2x4 3x6 5x8 5x8 3x4 3x4 8-4-7 8-4-7 13-11-4 5-6-13 19-6-1 5-6-13 27-10-8 8-4-7 -1-1-9 1-1-9 4-0-0 4-0-0 8-4-7 4-4-7 13-11-4 5-6-13 19-6-1 5-6-13 23-10-8 4-4-7 27-10-8 4-0-0 29-0-1 1-1-9 1-11-121-0-78-9-58-11-70-7-11-11-120-7-11-0-78-9-510.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [4:0-3-0,0-2-1], [6:0-3-0,0-2-1], [8:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.54 0.58 0.55 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.10 -0.22 0.04 0.02 (loc) 12-14 14-15 19 12-14 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 156 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 4-14,4-12,5-12,6-12,6-11: 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-4 oc purlins, except end verticals, and 2-0-0 oc purlins (4-9-2 max.): 4-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-12 REACTIONS.(lb/size)18=1599/0-3-8, 19=1597/0-3-8 Max Horz 18=172(LC 5) Max Uplift 18=-67(LC 6), 19=-67(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1674/156, 3-4=-1495/189, 4-5=-1302/204, 5-6=-1302/204, 6-7=-1492/189, 7-8=-1670/156 BOT CHORD 14-15=-109/256, 12-14=-83/1062, 11-12=-10/1059, 10-11=0/257 WEBS 4-12=-127/525, 5-12=-538/161, 6-12=-127/530, 2-14=-23/997, 8-11=-23/994, 2-18=-1627/135, 8-19=-1625/135 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Bearing at joint(s) 18, 19 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 19. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T05 Truss Type Hip Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153325 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-3FQwMmnICBVjS4jTK9TTIEqTxnu5n_szGfBMWkzlBjo Scale = 1:55.0 1 2 3 4 5 6 7 8 13 12 11 10 9 14 1516 17 18 19 6x6 5x6 3x6 3x8 3x6 3x4 3x6 5x6 5x8 5x8 5x6 3x4 3x4 9-0-0 9-0-0 18-10-8 9-10-8 27-10-8 9-0-0 -1-1-9 1-1-9 4-0-0 4-0-0 10-9-4 6-9-4 17-1-4 6-4-1 23-10-8 6-9-4 27-10-8 4-0-0 29-0-1 1-1-9 1-11-121-0-710-9-510-11-70-7-11-11-120-7-11-0-710-9-510.00 12 Plate Offsets (X,Y)-- [4:0-3-7,Edge], [5:0-3-0,0-2-1] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.71 0.97 0.53 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.42 -0.62 0.05 0.15 (loc) 10-12 10-12 17 10-12 l/defl >793 >534 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 143 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 9-11: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 3-12,6-10,3-13,6-9: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-5-8 oc purlins, except end verticals, and 2-0-0 oc purlins (5-1-8 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-12, 3-13, 6-9 REACTIONS.(lb/size)16=1587/0-3-8, 17=1608/0-3-8 Max Horz 16=221(LC 5) Max Uplift 16=-302(LC 6), 17=-302(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-336/233, 3-4=-1513/614, 4-5=-976/490, 5-6=-1549/616, 6-7=-332/230, 13-14=-361/1204, 2-14=-361/1204, 9-15=-363/1228, 7-15=-363/1228 BOT CHORD 12-13=-289/1033, 10-12=-167/984, 9-10=-276/1053 WEBS 4-12=-257/343, 5-10=-266/411, 3-13=-1404/350, 6-9=-1444/355, 2-16=-1612/570, 7-17=-1634/570 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Bearing at joint(s) 16, 17 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 16=302, 17=302. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T06 Truss Type PIGGYBACK BASE Qty 3 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153326 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:32 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-XR_Ia6owzVda4EIfts_irRMiDBNgWPD6VJww2BzlBjn Scale = 1:58.7 1 2 3 4 5 6 13 12 11 10 9 8 7141516 4x6 4x8 4x6 4x6 2x4 3x4 3x6 3x8 3x4 3x8 3x6 3x8 2x4 5-6-0 5-6-0 11-8-9 6-2-9 16-6-7 4-9-14 22-9-0 6-2-9 28-3-0 5-6-0 5-6-0 5-6-0 11-8-9 6-2-9 16-6-7 4-9-14 22-9-0 6-2-9 28-3-0 5-6-0 1-9-1411-7-01-9-1411-7-010.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [3:0-6-4,0-2-0], [4:0-4-4,0-2-0], [6:0-3-0,0-1-8], [8:0-3-8,0-1-8], [12:0-3-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.48 0.44 0.65 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.07 -0.16 0.04 0.07 (loc) 11-12 11-12 7 11-12 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 155 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-11,3-11,3-9,4-9,5-9: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-11 oc purlins, except end verticals, and 2-0-0 oc purlins (5-7-15 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-11, 3-9, 5-9 REACTIONS.(lb/size)13=1554/0-3-8, 7=1547/0-3-8 Max Horz 13=279(LC 5) Max Uplift 13=-265(LC 6), 7=-265(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1667/570, 2-3=-1447/571, 3-4=-973/492, 4-5=-1437/571, 5-6=-1660/570, 1-13=-1511/481, 6-7=-1504/480 BOT CHORD 12-13=-279/268, 11-12=-337/1195, 9-11=-235/980, 8-9=-326/1189 WEBS 2-11=-333/221, 3-11=-258/436, 4-9=-259/393, 5-9=-335/220, 1-12=-327/1183, 6-8=-327/1177 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 13=265, 7=265. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T08 Truss Type Roof Special Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153327 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:32 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-XR_Ia6owzVda4EIfts_irRMh5BIqWNi6VJww2BzlBjn Scale = 1:54.5 1 2 3 4 5 6 7 12 11 10 9 8131415161718 3x6 3x4 3x4 3x4 3x4 3x6 3x6 3x4 3x8 3x6 3x6 5x6 9-4-0 9-4-0 18-4-8 9-0-8 25-6-8 7-2-0 6-3-13 6-3-13 12-4-3 6-0-5 18-4-8 6-0-5 21-9-12 3-5-4 25-6-8 3-8-12 9-5-99-7-112-5-119-5-912.00 12 Plate Offsets (X,Y)-- [5:0-3-9,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.55 0.75 0.81 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.21 -0.43 0.04 0.02 (loc) 11-12 11-12 8 9-11 l/defl >999 >705 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 143 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 10-12: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 6-9,7-8,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-10 oc purlins, except end verticals, and 2-0-0 oc purlins (5-3-15 max.): 1-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 1-12, 2-12, 4-11, 4-9, 6-8 REACTIONS.(lb/size)12=1536/Mechanical, 8=1484/Mechanical Max Horz 12=-214(LC 7) Max Uplift 12=-113(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1031/90, 4-5=-862/136, 5-6=-1308/142 BOT CHORD 11-12=-84/815, 9-11=-81/1088, 8-9=-0/788 WEBS 2-12=-1429/161, 2-11=-3/692, 4-9=-482/119, 5-9=-11/498, 6-9=-56/261, 6-8=-1425/2 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 12=113. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T09 Truss Type Hip Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153328 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:33 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-0eYgnSpYjolRiOtrRZVxOfvoPbdjFsFFkzgTadzlBjm Scale = 1:61.1 1 2 3 4 5 6 11 10 9 8 71213141516 3x4 5x6 5x8 5x6 2x4 3x4 3x8 3x6 3x6 3x8 3x6 8-0-8 8-0-8 16-4-8 8-4-0 25-6-8 9-2-0 5-4-8 5-4-8 8-0-8 2-8-0 16-4-8 8-4-0 22-2-4 5-9-12 25-6-8 3-4-4 7-2-88-11-1111-5-911-7-112-5-1111-5-93.94 12 12.00 12 Plate Offsets (X,Y)-- [3:0-5-9,0-2-8], [4:0-3-9,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.77 0.77 0.66 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.17 -0.39 0.04 0.03 (loc) 8-10 7-8 7 10-11 l/defl >999 >785 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 148 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-4: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 5-8,1-11,6-7,5-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-7 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10, 5-7, 2-11 REACTIONS.(lb/size)7=1493/Mechanical, 11=1512/Mechanical Max Horz 11=285(LC 5) Max Uplift 7=-10(LC 7), 11=-103(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1125/237, 3-4=-780/205, 4-5=-1340/200 BOT CHORD 10-11=-172/733, 8-10=-59/835, 7-8=-1/769 WEBS 2-10=0/318, 3-10=-49/263, 4-8=-17/337, 5-7=-1425/90, 2-11=-1382/102 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7 except (jt=lb) 11=103. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T10 Truss Type PIGGYBACK BASE Qty 3 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153329 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:33 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-0eYgnSpYjolRiOtrRZVxOfvobbcDFsVFkzgTadzlBjm Scale = 1:59.1 1 2 3 4 5 6 7 12 11 10 9 81314151617 3x4 5x6 4x6 6x8 3x4 3x8 3x4 3x6 3x8 3x4 3x6 8-4-13 8-4-13 16-0-3 7-7-6 25-6-8 9-6-5 5-4-8 5-4-8 8-4-13 3-0-5 16-0-3 7-7-6 22-2-4 6-2-1 25-6-8 3-4-4 26-11-8 1-5-0 7-2-88-11-1112-0-02-5-1112-0-03.94 12 12.00 12 Plate Offsets (X,Y)-- [4:0-4-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.82 0.87 0.64 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.23 -0.57 0.04 0.01 (loc) 8-9 8-9 8 9-11 l/defl >999 >529 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 154 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 1-12,6-8,5-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-4-4 oc purlins, except end verticals, and 2-0-0 oc purlins (4-1-9 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-11, 5-8, 2-12 REACTIONS.(lb/size)8=1613/0-3-8, 12=1508/Mechanical Max Horz 12=-292(LC 7) Max Uplift 8=-42(LC 7), 12=-83(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1134/194, 3-4=-763/174, 4-5=-1310/178, 6-8=-269/147 BOT CHORD 11-12=-118/720, 9-11=-26/804, 8-9=0/746 WEBS 2-11=0/254, 3-11=-30/302, 4-9=-30/318, 5-8=-1386/7, 2-12=-1349/125 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 12. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T12 Truss Type Piggyback Base Qty 3 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153330 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:34 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-Uq62?opAU6tIJYS1?H1AwsSx0_yM_J6PydP063zlBjl Scale = 1:74.9 1 2 3 4 5 6 7 14 13 12 11 10 9 81516171819 5x6 4x8 6x10 2x4 3x4 3x6 2x4 5x12 4x8 3x4 3x6 6x6 4x6 3x8 7-5-0 7-5-0 17-6-5 10-1-5 25-1-11 7-7-6 34-8-0 9-6-5 7-4-12 7-4-12 14-6-0 7-1-4 17-6-5 3-0-5 25-1-11 7-7-6 31-3-12 6-2-1 34-8-0 3-4-4 4-2-98-11-1112-0-02-5-1112-0-03.94 12 12.00 12 Plate Offsets (X,Y)-- [4:0-5-0,0-1-12], [5:0-6-8,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.91 0.87 0.69 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.43 -0.78 0.07 0.05 (loc) 11-13 11-13 8 11-13 l/defl >959 >529 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 186 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-5: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF 2100F 1.8E *Except* 8-10: 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 2-13,1-14,7-8,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-9 oc purlins, except end verticals, and 2-0-0 oc purlins (4-10-5 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-13, 3-11, 5-11, 1-14, 6-8 REACTIONS.(lb/size)14=1931/0-3-8, 8=2021/0-4-3 Max Horz 14=312(LC 5) Max Uplift 14=-144(LC 4), 8=-15(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2086/209, 2-3=-2111/301, 3-4=-2233/326, 4-5=-1545/268, 5-6=-1928/250, 1-14=-1896/180 BOT CHORD 13-14=-277/127, 11-13=-146/1963, 9-11=-46/1238, 8-9=-32/1073 WEBS 2-13=-666/240, 3-11=-1252/282, 4-11=-125/1084, 5-11=-118/674, 5-9=-22/254, 6-9=-77/334, 1-13=-124/2141, 6-8=-1995/163 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8 except (jt=lb) 14=144. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T13 Truss Type Piggyback Base Qty 3 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153331 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:35 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-y0gQC8qoFQ?9xi1EZ_YPT4_5xOHojmUYBH9afVzlBjk Scale = 1:69.3 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 21 22 23 24 25 5x6 6x8 8x8 4x6 3x4 3x6 2x4 2x4 2x4 5x12 8x8 6x10 5x12 3x6 2x4 6x6 7-4-12 7-4-12 17-6-5 10-1-9 19-3-7 1-9-2 25-1-11 5-10-4 34-8-0 9-6-5 7-4-12 7-4-12 14-6-0 7-1-4 17-6-5 3-0-5 19-3-7 1-9-2 25-1-11 5-10-4 29-9-1 4-7-7 34-8-0 4-10-15 4-2-98-11-1112-0-00-9-51-8-612-0-03.94 12 12.00 12 Plate Offsets (X,Y)-- [4:0-4-12,0-1-8], [6:0-4-8,0-1-4], [9:0-0-0,0-3-6], [11:0-2-4,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-MS 0.90 0.92 0.68 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.40 -0.71 0.11 0.06 (loc) 13-15 13-15 9 10-11 l/defl >999 >586 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 201 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 12-14: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 2-15,7-10,1-16: 2x4 SPF-S Stud SLIDER Right 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-14 oc purlins, except end verticals, and 2-0-0 oc purlins (3-10-3 max.): 4-6. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. Except: 1 Row at midpt 5-11 WEBS 1 Row at midpt 3-15, 3-13, 4-13, 1-16 REACTIONS.(lb/size)9=1996/0-5-8, 16=1922/0-3-8 Max Horz 16=280(LC 5) Max Uplift 9=-16(LC 7), 16=-142(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2065/210, 2-3=-2092/303, 3-4=-2244/325, 4-5=-1733/269, 5-6=-1742/270, 6-7=-2159/259, 7-9=-2375/212, 1-16=-1878/181 BOT CHORD 13-15=-114/1951, 11-12=-332/0, 5-11=-420/146, 10-11=-16/1431, 9-10=-60/1596 WEBS 2-15=-669/240, 3-15=-265/11, 3-13=-1281/291, 11-13=-81/2316, 4-11=-121/1389, 6-11=-147/707, 6-10=-34/524, 7-10=-268/178, 1-15=-126/2116 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9 except (jt=lb) 16=142. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T14 Truss Type PIGGYBACK BASE Qty 3 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153332 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:35 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-y0gQC8qoFQ?9xi1EZ_YPT4_4LOLrjmWYBH9afVzlBjk Scale = 1:60.5 1 2 3 4 5 6 7 13 12 11 10 9 81415 5x6 4x8 6x10 3x4 3x6 2x4 5x12 4x8 3x6 6x6 3x4 6x8 7-4-12 7-4-12 17-6-5 10-1-9 25-1-11 7-7-6 32-0-0 6-10-5 7-4-12 7-4-12 14-6-0 7-1-4 17-6-5 3-0-5 25-1-11 7-7-6 32-0-0 6-10-5 33-5-0 1-5-0 4-2-98-11-1112-0-05-1-1112-0-03.94 12 12.00 12 Plate Offsets (X,Y)-- [4:0-5-1,0-2-0], [5:0-6-4,0-1-0], [6:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 1.00 0.66 0.68 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.39 -0.71 0.04 0.05 (loc) 10-12 10-12 8 10-12 l/defl >967 >536 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 178 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 2-12,1-13,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-2 oc purlins, except end verticals, and 2-0-0 oc purlins (2-1-0 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-12, 3-10, 5-10, 5-9, 1-13, 6-8 REACTIONS.(lb/size)13=1764/0-3-8, 8=1940/0-3-8 Max Horz 13=326(LC 5) Max Uplift 13=-144(LC 4), 8=-42(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1883/207, 2-3=-1909/299, 3-4=-1887/319, 4-5=-1299/263, 5-6=-1434/241, 1-13=-1728/177, 6-8=-1884/196 BOT CHORD 12-13=-291/154, 10-12=-168/1689, 9-10=-73/874 WEBS 2-12=-667/241, 3-10=-1163/280, 4-10=-120/840, 5-10=-106/849, 5-9=-364/125, 1-12=-126/1922, 6-9=-66/1046 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8 except (jt=lb) 13=144. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T15 Truss Type Piggyback Base Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153333 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:36 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-QDEpQUrR0j70ZscQ6i3e?HXGdog8SDmiQxu7ByzlBjj Scale = 1:70.7 1 2 3 4 5 6 7 8 15 14 13 12 11 10 916171819 5x6 4x8 6x8 3x4 3x6 2x4 5x12 4x8 3x4 3x6 6x6 5x6 2x4 3x6 7-4-12 7-4-12 17-6-5 10-1-9 25-1-11 7-7-6 33-4-0 8-2-5 7-4-12 7-4-12 14-6-0 7-1-4 17-6-5 3-0-5 25-1-11 7-7-6 31-3-12 6-2-1 33-4-0 2-0-4 34-9-0 1-5-0 4-2-98-11-1112-0-03-9-1112-0-03.94 12 12.00 12 Plate Offsets (X,Y)-- [4:0-5-1,0-2-0], [5:0-4-12,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.90 0.72 0.68 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.41 -0.74 0.05 0.05 (loc) 12-14 12-14 9 12-14 l/defl >973 >538 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 185 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-5: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF 2100F 1.8E *Except* 9-11: 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 2-14,1-15,7-9,6-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-6 oc purlins, except end verticals, and 2-0-0 oc purlins (5-1-5 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-14, 3-12, 5-12, 5-10, 1-15, 6-9 REACTIONS.(lb/size)15=1847/0-3-8, 9=2077/0-3-8 Max Horz 15=310(LC 5) Max Uplift 15=-145(LC 4), 9=-51(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1983/209, 2-3=-2009/301, 3-4=-2059/324, 4-5=-1421/267, 5-6=-1675/251, 1-15=-1811/180 BOT CHORD 14-15=-274/175, 12-14=-150/1825, 10-12=-53/1055, 9-10=-3/610 WEBS 2-14=-666/240, 3-12=-1209/282, 4-12=-124/962, 5-12=-109/757, 6-10=-68/606, 1-14=-126/2030, 6-9=-1885/64 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9 except (jt=lb) 15=145. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T16 Truss Type Piggyback Base Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153334 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:37 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-uPnBdps3n1FtA?BcgPatYV4RMCz7Bf0rfbegjOzlBji Scale = 1:60.1 1 2 3 4 5 6 7 14 13 12 11 10 9 81516171819 5x6 4x8 6x8 2x4 3x4 3x8 2x4 5x12 4x8 3x4 3x6 6x6 5x6 3x6 7-4-12 7-4-12 17-6-5 10-1-9 25-1-11 7-7-6 33-4-0 8-2-5 7-4-12 7-4-12 14-6-0 7-1-4 17-6-5 3-0-5 25-1-11 7-7-6 31-3-12 6-2-1 33-4-0 2-0-4 4-2-98-11-1112-0-03-9-1112-0-03.94 12 12.00 12 Plate Offsets (X,Y)-- [4:0-5-0,0-1-12], [5:0-4-12,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.90 0.93 0.68 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.43 -0.77 0.05 0.05 (loc) 11-13 11-13 8 11-13 l/defl >931 >517 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 183 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-5: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 10-12: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 2-13,1-14,7-8,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-6 oc purlins, except end verticals, and 2-0-0 oc purlins (5-1-1 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-13, 3-11, 5-11, 5-9, 1-14, 6-8 REACTIONS.(lb/size)14=1852/0-3-8, 8=1951/0-3-8 Max Horz 14=329(LC 5) Max Uplift 14=-143(LC 4), 8=-20(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1985/205, 2-3=-2011/297, 3-4=-2070/314, 4-5=-1428/259, 5-6=-1686/237, 1-14=-1812/176 BOT CHORD 13-14=-293/108, 11-13=-166/1832, 9-11=-68/1062, 8-9=-12/630 WEBS 2-13=-666/241, 3-11=-1208/280, 4-11=-117/969, 5-11=-111/760, 6-9=-76/602, 1-13=-126/2032, 6-8=-1927/179 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8 except (jt=lb) 14=143. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T18 Truss Type COMMON Qty 3 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153335 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:37 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-uPnBdps3n1FtA?BcgPatYV4S0C7JBowrfbegjOzlBji Scale = 1:54.4 1 2 3 4 7 6 5 4x6 6x8 2x4 2x4 3x8 6x8 6-6-0 6-6-0 13-0-0 6-6-0 -1-5-0 1-5-0 6-6-0 6-6-0 13-0-0 6-6-0 2-5-118-11-112-5-1112.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [4:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.86 0.28 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.04 -0.09 -0.00 -0.00 (loc) 5-6 5-6 5 5-6 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 65 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-6: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)7=768/0-3-8, 5=628/0-3-8 Max Horz 7=215(LC 5) Max Uplift 7=-44(LC 6), 5=-33(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-551/109, 3-4=-540/101, 2-7=-711/113, 4-5=-571/81 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T19 Truss Type Half Hip Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153336 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:38 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-MbLZq9shYLNko9mpE7565icj?cRQwDD?tFNEFqzlBjh Scale = 1:43.2 1 2 3 4 6 5 5x6 2x4 2x4 3x6 4x8 6-0-0 6-0-0 -1-5-0 1-5-0 4-10-8 4-10-8 6-0-0 1-1-8 2-5-117-2-17-4-36-10-90-3-87-2-112.00 12 Plate Offsets (X,Y)-- [3:0-3-14,Edge], [5:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.46 0.35 0.23 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.05 -0.13 -0.00 0.00 (loc) 5-6 5-6 5 6 l/defl >999 >500 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 39 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=414/0-3-8, 5=276/0-1-8 Max Horz 6=246(LC 6) Max Uplift 5=-155(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-360/0 BOT CHORD 5-6=-267/13 WEBS 2-5=-10/278 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 5=155. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T20 Truss Type Half Hip Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153337 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:38 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-MbLZq9shYLNko9mpE7565icmwcQnwDc?tFNEFqzlBjh Scale = 1:32.6 1 2 3 4 6 5 5x6 2x4 2x4 3x4 3x4 6-0-0 6-0-0 -1-5-0 1-5-0 2-10-8 2-10-8 6-0-0 3-1-8 2-5-115-2-15-4-34-10-90-3-85-2-112.00 12 Plate Offsets (X,Y)-- [3:0-3-9,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.28 0.39 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.16 0.00 0.00 (loc) 5-6 5-6 5 6 l/defl >999 >430 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 34 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=428/0-3-8, 5=268/0-1-8 Max Horz 6=184(LC 6) Max Uplift 5=-68(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-101/256, 2-6=-270/280 WEBS 3-6=-262/15 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T21 Truss Type Half Hip Qty 2 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153338 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:39 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-qnvx2VtJJeWbQJL?oqcLdw9rp?m2fjE86v7noHzlBjg Scale = 1:21.3 1 2 3 4 6 5 5x6 2x4 3x4 2x4 3x4 6-0-0 6-0-0 -1-5-0 1-5-0 0-10-8 0-10-8 6-0-0 5-1-8 2-5-113-2-13-4-32-10-90-3-83-2-112.00 12 Plate Offsets (X,Y)-- [3:0-3-0,0-1-15] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.65 0.39 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.16 -0.00 0.00 (loc) 5-6 5-6 5 6 l/defl >999 >430 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 29 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=428/0-3-8, 5=268/0-1-8 Max Horz 6=122(LC 6) Max Uplift 6=-22(LC 6), 5=-38(LC 7) Max Grav 6=428(LC 1), 5=278(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-105/255, 2-6=-288/313 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-5-0 to 5-10-4 zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T22 Truss Type Common Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153339 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:39 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-qnvx2VtJJeWbQJL?oqcLdw9vQ?pjfiY86v7noHzlBjg Scale: 1/4"=1' 1 2 3 4 5 8 7 6 4x6 2x4 2x4 3x8 4x6 4x6 5-6-0 5-6-0 11-0-0 5-6-0 -1-5-0 1-5-0 5-6-0 5-6-0 11-0-0 5-6-0 12-5-0 1-5-0 3-6-139-0-133-6-1312.00 12 Plate Offsets (X,Y)-- [2:0-2-12,0-1-8], [4:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.42 0.22 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.02 -0.05 0.00 0.03 (loc) 6-7 6-7 6 6-7 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 63 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-7: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-7 REACTIONS.(lb/size)8=660/0-5-8, 6=660/0-5-8 Max Horz 8=244(LC 5) Max Uplift 8=-132(LC 7), 6=-132(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-402/264, 3-4=-402/264, 2-8=-613/248, 4-6=-613/248 WEBS 3-7=-252/126 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=132, 6=132. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T23 Truss Type Roof Special Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153340 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:40 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-I_TJFrux4yeS1TvBLY7aA7i6PP35O0pHLZsLKjzlBjf Scale = 1:46.6 1 2 3 4 5 6 7 8 9 14 13 12 11 10 15 16 6x6 5x6 5x6 5x6 6x6 2x4 3x8 4x10 4x10 3x6 2x4 3x6 6-8-12 6-8-12 14-11-4 8-2-8 21-8-0 6-8-12 -1-5-0 1-5-0 4-3-12 4-3-12 6-8-12 2-5-0 10-10-0 4-1-4 14-11-4 4-1-4 17-4-4 2-5-0 21-8-0 4-3-12 23-1-0 1-5-0 2-5-116-7-58-10-12-5-116-7-512.00 12 6.00 12 Plate Offsets (X,Y)-- [3:0-3-14,Edge], [4:0-3-0,Edge], [6:0-3-0,Edge], [7:0-3-14,Edge], [11:0-4-8,0-2-0], [13:0-4-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.28 0.59 0.67 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.23 -0.38 0.01 0.02 (loc) 11-13 11-13 10 11-13 l/defl >999 >675 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 128 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-5,5-6: 2x6 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 5-13,5-11: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-8 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4, 6-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)14=1273/0-3-8, 10=1273/0-3-8 Max Horz 14=-202(LC 4) Max Uplift 14=-81(LC 6), 10=-81(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1114/148, 3-4=-860/157, 4-5=-1021/224, 5-6=-1021/224, 6-7=-860/157, 7-8=-1114/148, 2-14=-1239/163, 8-10=-1239/163 BOT CHORD 11-13=-23/744 WEBS 3-13=-36/459, 4-13=-661/151, 5-13=-73/375, 5-11=-73/375, 6-11=-661/151, 7-11=-36/459, 2-13=0/725, 8-11=0/725 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 10. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T24 Truss Type Roof Special Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153341 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:40 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-I_TJFrux4yeS1TvBLY7aA7i4pP4KO3yHLZsLKjzlBjf Scale = 1:46.6 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 6x16 5x8 6x16 2x4 3x6 4x8 3x8 4x6 2x4 4x6 4x8 2-8-12 2-8-12 10-10-0 8-1-4 18-11-4 8-1-4 21-8-0 2-8-12 -1-5-0 1-5-0 2-3-12 2-3-12 2-8-12 0-5-0 10-10-0 8-1-4 18-11-4 8-1-4 19-4-4 0-5-0 21-8-0 2-3-12 23-1-0 1-5-0 2-5-114-7-58-10-12-5-114-7-512.00 12 6.00 12 Plate Offsets (X,Y)-- [3:0-0-0,0-1-7], [3:0-5-8,0-2-4], [6:0-5-8,0-2-4], [7:0-0-0,0-1-7] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.44 0.52 0.47 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.08 -0.20 0.02 0.01 (loc) 11-12 11-12 10 12 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 127 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-5,5-6: 2x6 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 4-12,5-12,6-12: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4, 6-7. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)15=1194/0-3-8, 10=1194/0-3-8 Max Horz 15=179(LC 5) Max Uplift 15=-81(LC 6), 10=-81(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-778/142, 3-4=-564/133, 4-5=-941/184, 5-6=-941/184, 6-7=-564/133, 7-8=-778/142, 2-15=-1202/143, 8-10=-1202/143 BOT CHORD 12-14=-75/581, 11-12=0/581 WEBS 3-14=-197/567, 4-14=-919/245, 5-12=0/267, 6-11=-919/245, 7-11=-197/567, 2-14=0/726, 8-11=0/726 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 10. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss T25 Truss Type Roof Special Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153342 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:41 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-nA1iTBvZrGmJfdUOvFfpiLEGOpSB7WeRZCcus9zlBje Scale = 1:44.0 1 2 3 4 5 6 7 13 12 11 10 9 8 2x4 6x6 4x6 6x6 2x4 3x4 3x8 3x6 3x6 3x6 3x6 3x6 3x6 6-4-6 6-4-6 10-10-0 4-5-10 15-3-10 4-5-10 21-8-0 6-4-6 1-10-12 1-10-12 6-4-6 4-5-10 10-10-0 4-5-10 15-3-10 4-5-10 19-9-4 4-5-10 21-8-0 1-10-12 2-5-114-4-78-10-12-5-1112.00 12 6.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-15], [6:0-3-0,0-1-15] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.32 0.41 0.51 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.04 -0.11 0.02 0.01 (loc) 8-9 8-9 8 12 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 113 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 4-10: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-5 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)8=1069/0-3-8, 13=1069/0-3-8 Max Horz 13=170(LC 5) Max Uplift 8=-34(LC 7), 13=-34(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-946/164, 3-4=-849/206, 4-5=-849/206, 5-6=-946/164 BOT CHORD 12-13=-106/427, 10-12=-37/784, 9-10=0/784, 8-9=0/427 WEBS 4-10=-88/365, 5-10=-261/88, 6-9=0/481, 3-10=-261/88, 2-12=0/481, 2-13=-1012/82, 6-8=-1012/82 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 13. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss TG01 Truss Type Hip Girder Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153343 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:42 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-FMb4gXwBcZu9Hn3aTyA2FYnKTDlLstnaosLROczlBjd Scale = 1:46.0 1 2 3 4 5 10 9 8 7 6 11 12 13 14 15 6x6 5x12 4x6 3x6 4x6 8x8 3x4 6x8 8x8 6-0-0 6-0-0 11-0-0 5-0-0 17-0-0 6-0-0 6-0-0 6-0-0 11-0-0 5-0-0 17-0-0 6-0-0 18-5-0 1-5-0 2-5-118-5-112-5-118-5-1112.00 12 Plate Offsets (X,Y)-- [2:0-8-0,0-0-12], [3:0-4-4,0-1-12], [4:0-3-8,Edge], [9:0-3-8,0-4-0] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.82 0.61 0.83 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.12 0.01 0.06 (loc) 9-10 9-10 6 7-9 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 99 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-7: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-6-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-4-14 oc bracing. WEBS 1 Row at midpt 2-7 REACTIONS.(lb/size)10=2013/0-3-8, 6=1774/0-3-8 Max Horz 10=-235(LC 3) Max Uplift 10=-720(LC 5), 6=-761(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1627/724, 2-3=-1014/649, 3-4=-1600/820, 1-10=-1603/662, 4-6=-1722/799 BOT CHORD 7-9=-542/1043 WEBS 2-9=-319/669, 3-7=-524/681, 1-9=-524/977, 4-7=-603/988 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 10=720, 6=761. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 260 lb down and 52 lb up at 0-11-4, 248 lb down and 84 lb up at 2-11-4, 256 lb down and 167 lb up at 4-11-4, 248 lb down and 208 lb up at 6-11-4, and 248 lb down and 208 lb up at 8-11-4, and 634 lb down and 702 lb up at 10-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-80, 2-3=-80, 3-4=-80, 4-5=-80, 9-10=-20, 9-14=-60, 6-14=-20 Concentrated Loads (lb) Vert: 8=-248 7=-634 11=-260 12=-248 13=-256 15=-248 February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss TG02 Truss Type Common Girder Qty 1 Ply 2 McKenzie 284 Westvale Job Reference (optional) I36153344 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:43 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-jZ9SutwqNt00uwem1ghHolKTod6?bIck1W5?x2zlBjc Scale = 1:54.1 1 2 3 4 5 6 12 11 10 9 8 713141516 6x6 4x8 3x4 4x8 10x10 3x6 6x8 3x6 3x4 6x6 8x10 3-6-0 3-6-0 8-6-0 5-0-0 11-8-8 3-2-8 17-0-0 5-3-8 3-6-0 3-6-0 8-6-0 5-0-0 11-8-8 3-2-8 17-0-0 5-3-8 18-5-0 1-5-0 2-5-1110-11-112-5-1112.00 12 Plate Offsets (X,Y)-- [8:0-3-8,0-4-0], [11:0-3-0,0-4-4] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.91 0.52 0.99 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.09 -0.16 0.01 0.05 (loc) 9-11 9-11 7 8 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 242 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 3-9,1-11: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-6 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)12=6632/0-3-8, 7=5327/0-3-8 Max Horz 12=-293(LC 3) Max Uplift 12=-780(LC 6), 7=-1152(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-5193/679, 2-3=-4288/823, 3-4=-4226/836, 4-5=-5007/1158, 1-12=-6039/750, 5-7=-5195/1143 BOT CHORD 11-12=-235/281, 9-11=-540/3616, 8-9=-738/3424 WEBS 3-9=-1093/5520, 4-9=-1269/854, 2-11=0/1210, 1-11=-496/4236, 4-8=-939/1394, 5-8=-789/3617, 2-9=-1057/134 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-6-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 12=780, 7=1152. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1488 lb down and 95 lb up at 1-9-4, 1488 lb down and 95 lb up at 3-9-4, 1488 lb down and 95 lb up at 5-9-4, 1492 lb down and 115 lb up at 7-9-4, and 1516 lb down and 134 lb up at 9-9-4, and 2691 lb down and 1314 lb up at 11-8-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard Continued on page 2 February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss TG02 Truss Type Common Girder Qty 1 Ply 2 McKenzie 284 Westvale Job Reference (optional) I36153344 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:43 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-jZ9SutwqNt00uwem1ghHolKTod6?bIck1W5?x2zlBjc LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-80, 3-5=-80, 5-6=-80, 7-12=-20 Concentrated Loads (lb) Vert: 11=-1488(B) 8=-2691(B) 13=-1488(B) 14=-1488(B) 15=-1492(B) 16=-1516(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss TG03 Truss Type Common Girder Qty 1 Ply 2 McKenzie 284 Westvale Job Reference (optional) I36153345 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:43 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-jZ9SutwqNt00uwem1ghHolKZhd6mbJmk1W5?x2zlBjc Scale = 1:46.6 1 2 3 4 7 6 589 4x6 4x6 3x6 3x6 10x10 4x6 5-2-0 5-2-0 10-4-0 5-2-0 5-2-0 5-2-0 10-4-0 5-2-0 11-9-0 1-5-0 2-5-117-7-112-5-1112.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.53 0.53 0.91 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.07 -0.13 0.00 0.03 (loc) 6-7 6-7 5 6 l/defl >999 >919 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 129 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 1-7,3-5: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)7=4527/0-3-8, 5=2878/0-3-8 Max Horz 7=-215(LC 3) Max Uplift 7=-947(LC 6), 5=-1066(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2755/1043, 2-3=-2762/1045, 1-7=-2755/1024, 3-5=-2976/1034 WEBS 2-6=-1364/3347, 1-6=-792/1768, 3-6=-767/1985 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc. Webs connected as follows: 2x4 - 1 row at 0-8-0 oc, Except member 6-1 2x4 - 1 row at 0-9-0 oc, member 6-3 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 7=947, 5=1066. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1473 lb down and 22 lb up at 1-1-4, 1464 lb down at 3-1-4, 2605 lb down and 1217 lb up at 5-0-8, and 467 lb down and 594 lb up at 5-1-0, and 268 lb down and 401 lb up at 5-3-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-80, 2-3=-80, 3-4=-80, 5-7=-20 Concentrated Loads (lb) Vert: 6=-3339(F=-2605) 8=-1473(F) 9=-1464(F) February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss TG04 Truss Type Hip Girder Qty 1 Ply 2 McKenzie 284 Westvale Job Reference (optional) I36153346 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:44 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-Bljq5DxS8B8tW4DyaNCWKzsnK0WgKvJtGAqYTUzlBjb Scale = 1:55.8 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 1819 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 5x6 3x4 2x4 4x6 3x6 3x6 3x6 2x4 3x12 5x6 3x6 6x6 2x4 6x6 3x4 3x4 3-6-13 3-6-13 10-5-3 6-10-6 17-5-5 7-0-2 24-3-11 6-10-6 27-10-8 3-6-13 -1-1-9 1-1-9 3-6-13 3-6-13 10-5-3 6-10-6 17-5-5 7-0-2 24-3-11 6-10-6 27-10-8 3-6-13 29-0-1 1-1-9 1-11-121-0-74-9-54-11-70-7-11-11-120-7-11-0-74-9-510.00 12 Plate Offsets (X,Y)-- [3:0-3-0,0-2-1], [7:0-3-0,0-2-1] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.34 0.23 0.38 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.12 0.02 0.07 (loc) 12-14 12-14 20 12-14 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 278 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-16,2-15,8-10,8-11: 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)19=1522/0-3-8, 20=1523/0-3-8 Max Horz 19=76(LC 4) Max Uplift 19=-646(LC 4), 20=-662(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1329/667, 3-4=-2163/1021, 4-6=-2158/1064, 6-7=-2161/1066, 7-8=-1332/692 BOT CHORD 14-15=-551/993, 12-14=-1018/2160, 11-12=-529/996 WEBS 3-15=-333/183, 3-14=-585/1404, 4-14=-614/330, 6-12=-609/339, 7-12=-617/1398, 7-11=-329/194, 2-15=-513/908, 8-11=-528/912, 2-19=-1546/656, 8-20=-1547/673 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 19, 20 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 19=646, 20=662. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Continued on page 2 February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss TG04 Truss Type Hip Girder Qty 1 Ply 2 McKenzie 284 Westvale Job Reference (optional) I36153346 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:45 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-fxGCIZy4vUGk8Eo985jltAPy4Qsv3MY1Uqa6?wzlBja NOTES- 12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 91 lb down and 158 lb up at 3-6-13, 43 lb down and 78 lb up at 5-7-9, 43 lb down and 78 lb up at 7-7-9, 43 lb down and 78 lb up at 9-7-9, 43 lb down and 78 lb up at 16-2-15, 43 lb down and 78 lb up at 18-2-15, 43 lb down and 78 lb up at 20-2-15, and 43 lb down and 78 lb up at 22-2-15, and 91 lb down and 158 lb up at 24-3-11 on top chord, and 18 lb down and 82 lb up at 3-6-13, 8 lb down and 42 lb up at 5-7-9, 8 lb down and 42 lb up at 7-7-9, 8 lb down and 42 lb up at 9-7-9, 8 lb down and 42 lb up at 16-2-15, 8 lb down and 42 lb up at 18-2-15, 8 lb down and 42 lb up at 20-2-15, and 8 lb down and 42 lb up at 22-2-15, and 18 lb down and 82 lb up at 24-2-15 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-80, 2-3=-80, 3-7=-80, 7-8=-80, 8-9=-80, 10-16=-20 Concentrated Loads (lb) Vert: 15=-18(F) 11=-18(F) 28=-8(F) 29=-8(F) 30=-8(F) 31=-8(F) 32=-8(F) 33=-8(F) 34=-8(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss TG06 Truss Type Roof Special Girder Qty 1 Ply 2 McKenzie 284 Westvale Job Reference (optional) I36153347 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:45 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-fxGCIZy4vUGk8Eo985jltAPrJQoQ3Kc1Uqa6?wzlBja Scale = 1:44.8 1 2 3 4 5 6 12 11 10 9 8 7 13 14 15 16 17 18 19 20 21 22 23 24 25 2x4 4x6 3x4 4x6 4x6 4x6 3x6 2x4 3x8 5x6 3x6 2x4 6-11-4 6-11-4 13-8-12 6-9-8 20-4-8 6-7-12 25-6-8 5-2-0 6-11-4 6-11-4 13-8-12 6-9-8 20-4-8 6-7-12 25-6-8 5-2-0 7-5-97-7-112-5-117-5-912.00 12 Plate Offsets (X,Y)-- [5:0-3-9,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.78 0.46 0.51 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.07 -0.13 0.02 0.08 (loc) 8-9 8-9 7 8-9 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 285 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 1-11,2-9,5-9: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 1-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)12=2711/Mechanical, 7=2625/Mechanical Max Horz 12=-152(LC 6) Max Uplift 12=-1302(LC 4), 7=-1196(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-12=-2349/1126, 1-2=-2050/1019, 2-4=-2499/1242, 4-5=-2501/1243, 5-6=-2389/1106, 6-7=-2464/1094 BOT CHORD 9-11=-1034/2050, 8-9=-765/1600 WEBS 1-11=-1460/2930, 2-11=-1057/402, 2-9=-344/649, 4-9=-590/188, 5-9=-715/1370, 5-8=-278/218, 6-8=-840/1686 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 12=1302, 7=1196. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Continued on page 2 February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss TG06 Truss Type Roof Special Girder Qty 1 Ply 2 McKenzie 284 Westvale Job Reference (optional) I36153347 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:45 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-fxGCIZy4vUGk8Eo985jltAPrJQoQ3Kc1Uqa6?wzlBja NOTES- 12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 204 lb down and 195 lb up at 1-9-12, 204 lb down and 195 lb up at 3-9-12, 204 lb down and 195 lb up at 5-9-12, 204 lb down and 195 lb up at 7-9-12, 204 lb down and 195 lb up at 9-9-12, 204 lb down and 195 lb up at 11-9-12, 204 lb down and 195 lb up at 13-9-12, 204 lb down and 195 lb up at 15-9-12, 204 lb down and 195 lb up at 17-9-12, 204 lb down and 195 lb up at 19-9-12, and 204 lb down and 195 lb up at 21-9-12, and 204 lb down and 195 lb up at 23-9-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-5=-80, 5-6=-80, 12-14=-60, 11-14=-20, 11-18=-60, 18-21=-20, 8-21=-60, 7-8=-20 Concentrated Loads (lb) Vert: 10=-204 9=-204 13=-204 15=-204 16=-204 17=-204 19=-204 20=-204 22=-204 23=-204 24=-204 25=-204 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss TG07 Truss Type Hip Girder Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153348 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:46 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-78qbWuzigoOblONLioE_POy0xq6SokqAjUJfYNzlBjZ Scale = 1:46.3 1 2 3 4 5 9 8 7 6 10 11 12 4x6 4x6 6x8 3x6 3x6 3x6 3x6 6x8 6-0-0 6-0-0 7-0-0 1-0-0 13-0-0 6-0-0 -1-5-0 1-5-0 6-0-0 6-0-0 7-0-0 1-0-0 13-0-0 6-0-0 2-5-118-5-112-5-118-5-1112.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [3:0-4-4,0-1-12], [4:0-4-4,0-1-12], [5:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.78 0.60 0.70 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.07 -0.14 -0.00 0.07 (loc) 6-7 6-7 6 6-7 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 77 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-12 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)9=1270/0-3-8, 6=1525/0-3-8 Max Horz 9=235(LC 4) Max Uplift 9=-503(LC 5), 6=-572(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1099/564, 3-4=-658/449, 4-5=-1090/562, 2-9=-1241/526, 5-6=-1082/504 BOT CHORD 7-8=-390/658 WEBS 3-8=-436/555, 4-7=-441/586, 2-8=-399/624, 5-7=-392/564 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 9=503, 6=572. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 634 lb down and 702 lb up at 6-0-0, 256 lb down and 167 lb up at 8-0-12, and 248 lb down and 84 lb up at 10-0-12, and 260 lb down and 52 lb up at 12-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-80, 2-3=-80, 3-4=-80, 4-5=-80, 6-9=-20 Concentrated Loads (lb) Vert: 8=-634 10=-256 11=-248 12=-260 February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss TG08 Truss Type Hip Girder Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153349 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:47 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-bKOzjEzKQ6WSNYyXGWlDybUH_EaZXExJy83C4pzlBjY Scale = 1:45.2 1 2 3 4 5 6 10 9 8 7 11 12 4x8 4x6 3x12 3x12 3x4 3x8 4x6 3x8 4-0-0 4-0-0 7-0-0 3-0-0 11-0-0 4-0-0 -1-5-0 1-5-0 4-0-0 4-0-0 7-0-0 3-0-0 11-0-0 4-0-0 12-5-0 1-5-0 3-6-137-6-133-6-137-6-1312.00 12 Plate Offsets (X,Y)-- [2:0-3-7,0-1-8], [3:0-6-4,0-1-12], [4:0-4-4,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.45 0.09 0.45 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.02 -0.00 0.03 (loc) 8 8 7 8-9 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 77 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-6-15 oc bracing. REACTIONS.(lb/size)10=846/0-5-8, 7=853/0-5-8 Max Horz 10=-207(LC 3) Max Uplift 10=-940(LC 5), 7=-967(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-523/769, 3-4=-283/606, 4-5=-526/797, 2-10=-807/926, 5-7=-811/963 BOT CHORD 8-9=-563/282 WEBS 3-9=-338/84, 4-8=-363/93, 2-9=-653/357, 5-8=-679/359 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed; porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 10=940, 7=967. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 184 lb down and 138 lb up at 4-0-0, and 60 lb down and 69 lb up at 6-0-12, and 184 lb down and 138 lb up at 7-0-0 on top chord, and 87 lb down and 583 lb up at 4-0-0, and 36 lb down and 195 lb up at 6-0-12, and 87 lb down and 583 lb up at 6-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-80, 2-3=-80, 3-4=-80, 4-5=-80, 5-6=-80, 7-10=-20 Concentrated Loads (lb) Vert: 3=-114(B) 4=-114(B) 9=-43(B) 8=-43(B) 11=-46(B) 12=-18(B) February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss TG09 Truss Type Hip Girder Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153350 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:47 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-bKOzjEzKQ6WSNYyXGWlDybUAqEXPX6dJy83C4pzlBjY Scale = 1:44.8 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 18 19 20 6x6 6x6 3x12 4x8 6x8 6x8 2x4 6x8 6x8 3x12 6x8 6-3-12 6-3-12 10-10-0 4-6-4 15-4-4 4-6-4 21-8-0 6-3-12 -1-5-0 1-5-0 6-3-12 6-3-12 10-10-0 4-6-4 15-4-4 4-6-4 21-8-0 6-3-12 23-1-0 1-5-0 2-5-118-7-58-9-72-5-118-7-512.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [3:0-3-14,Edge], [5:0-3-14,Edge], [6:0-3-8,Edge], [9:0-3-8,0-3-0], [12:0-3-8,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.84 0.29 0.99 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.07 -0.14 0.01 0.09 (loc) 9-10 9-10 8 9-10 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 146 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 3-10,5-10,2-13,6-8: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-0-3 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 REACTIONS.(lb/size)13=2529/0-3-8, 8=2583/0-3-8 Max Horz 13=-222(LC 11) Max Uplift 13=-1200(LC 5), 8=-1238(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2390/1270, 3-4=-1957/1149, 4-5=-1957/1149, 5-6=-2463/1326, 2-13=-2471/1228, 6-8=-2542/1283 BOT CHORD 10-12=-947/1555, 9-10=-914/1605 WEBS 3-12=-459/458, 3-10=-553/908, 4-10=-436/153, 5-10=-475/805, 5-9=-567/601, 2-12=-949/1548, 6-9=-997/1608 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 13=1200, 8=1238. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 725 lb down and 734 lb up at 6-5-4, 271 lb down and 215 lb up at 8-6-0, 271 lb down and 215 lb up at 10-6-0, 271 lb down and 215 lb up at 12-6-0, and 271 lb down and 215 lb up at 14-6-0, and 725 lb down and 734 lb up at 15-2-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-80, 2-3=-80, 3-5=-80, 5-6=-80, 6-7=-80, 12-13=-20, 12-15=-60, 15-18=-20, 9-18=-60, 8-9=-20 Continued on page 2 February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss TG09 Truss Type Hip Girder Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153350 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:47 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-bKOzjEzKQ6WSNYyXGWlDybUAqEXPX6dJy83C4pzlBjY LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 12=-454 14=-271 15=-271 16=-271 17=-271 19=-271 20=-725 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V01 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153351 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:48 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-3WyLxa_yBPeJ?iXkpDHSVp1Vxeu4GlOTAoomcFzlBjX Scale: 1/4"=1' 1 2 3 4 5 6 7 13 12 11 10 9 83x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 21-4-11 21-4-11 21-4-15 0-0-5 10-8-8 10-8-8 21-4-15 10-8-8 0-0-48-11-10-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.24 0.20 0.25 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 77 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-12: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 4-10: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 REACTIONS.All bearings 21-4-6. (lb) - Max Horz 1=-200(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 13, 8 except 11=-126(LC 6), 9=-126(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=470(LC 1), 11=516(LC 10), 13=336(LC 1), 9=516(LC 11), 8=336(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-356/176, 2-13=-276/138, 5-9=-356/176, 6-8=-275/138 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 13, 8 except (jt=lb) 11=126, 9=126. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V02 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153352 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:49 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-YjWj8w?ayjmAcr5wNwoh10age1FV?BycPSYJ8izlBjW Scale = 1:43.9 1 2 3 4 5 6 7 13 12 11 10 9 83x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 0-0-5 0-0-5 19-10-1 19-9-12 9-11-0 9-11-0 19-10-1 9-11-0 0-0-48-3-30-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.24 0.19 0.29 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 68 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-12: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 19-9-7. (lb) - Max Horz 1=184(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 13, 8 except 11=-127(LC 6), 9=-127(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=448(LC 1), 11=519(LC 10), 13=311(LC 1), 9=519(LC 11), 8=311(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-358/177, 2-13=-262/132, 5-9=-358/177, 6-8=-263/132 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 13, 8 except (jt=lb) 11=127, 9=127. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V03 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153353 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:49 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-YjWj8w?ayjmAcr5wNwoh10acL1B2?C0cPSYJ8izlBjW Scale = 1:39.5 1 2 3 4 5 9 8 7 63x6 4x6 3x6 3x4 2x4 2x4 2x4 2x4 2x4 0-0-5 0-0-5 18-3-3 18-2-14 9-1-9 9-1-9 18-3-3 9-1-9 0-0-47-7-50-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.45 0.41 0.23 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 60 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 18-2-9. (lb) - Max Horz 1=169(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1 except 9=-153(LC 6), 6=-153(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 8=417(LC 1), 9=604(LC 10), 6=604(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-415/204, 4-6=-418/205 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 9=153, 6=153. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V04 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153354 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:50 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-0v45MG0Dj1u1E?g6xeJwaE6q2RXUkfdme6Hsh8zlBjV Scale = 1:42.6 1 2 3 4 5 9 8 7 610113x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 0-0-5 0-0-5 16-8-4 16-7-15 8-4-2 8-4-2 16-8-4 8-4-2 0-0-46-11-70-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.27 0.33 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 53 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-7-11. (lb) - Max Horz 1=-154(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1 except 9=-138(LC 6), 6=-137(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 8=437(LC 1), 9=524(LC 10), 6=524(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-374/184, 4-6=-376/184 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 9=138, 6=137. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V05 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153355 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:50 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-0v45MG0Dj1u1E?g6xeJwaE6qkRabkhCme6Hsh8zlBjV Scale = 1:19.2 1 2 3 5 4 3x4 2x4 2x4 2x4 2x4 9-2-12 9-2-12 0-0-43-0-53.94 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.29 0.14 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 24 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=170/9-2-0, 4=145/9-2-0, 5=498/9-2-0 Max Horz 1=83(LC 4) Max Uplift 4=-15(LC 4), 5=-51(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-389/160 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V06 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153356 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:51 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-U5eUZc1rUK0us9FJVLqA6Rf?crxPT90vtm1QDazlBjU Scale = 1:7.9 1 2 3 2x4 2x4 2x4 3-1-10 3-1-10 0-0-41-0-53.94 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.21 0.10 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=102/3-0-14, 3=102/3-0-14 Max Horz 1=21(LC 4) Max Uplift 1=-3(LC 4), 3=-11(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V07 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153357 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:51 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-U5eUZc1rUK0us9FJVLqA6Rf?6rx6T8Zvtm1QDazlBjU Scale = 1:17.6 1 2 3 5 4 2x4 2x4 2x4 2x4 2x4 8-8-4 8-8-4 0-0-42-10-33.94 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.25 0.12 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=146/8-7-8, 4=153/8-7-8, 5=460/8-7-8 Max Horz 1=77(LC 4) Max Uplift 4=-16(LC 4), 5=-47(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-362/152 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V08 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153358 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:52 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-yIBsmy1TFe8lTJqV23LPffB9sFGgCac25Qmzl0zlBjT Scale = 1:35.1 1 2 3 4 5 8 7 69103x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 0-0-5 0-0-5 15-1-6 15-1-1 7-6-11 7-6-11 15-1-6 7-6-11 0-0-46-3-90-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.31 0.16 0.17 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 49 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 15-0-12. (lb) - Max Horz 1=-139(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1 except 8=-124(LC 6), 6=-124(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=429(LC 1), 8=453(LC 10), 6=453(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-340/167, 4-6=-340/167 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=124, 6=124. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V09 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153359 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:52 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-yIBsmy1TFe8lTJqV23LPffB9JFHYCa525Qmzl0zlBjT Scale = 1:33.9 1 2 3 4 5 8 7 63x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 0-0-5 0-0-5 13-6-7 13-6-3 6-9-4 6-9-4 13-6-7 6-9-4 0-0-45-7-110-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.28 0.10 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 43 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 13-5-14. (lb) - Max Horz 1=-123(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-115(LC 6), 6=-114(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=280(LC 1), 8=388(LC 10), 6=388(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-317/156, 4-6=-317/156 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=115, 6=114. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V10 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153360 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:53 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-QUlE_I250yGc5TPhcmseCskFKfdlx2gCK4WXHTzlBjS Scale = 1:31.6 1 2 3 4 5 8 7 63x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 0-0-5 0-0-5 11-11-9 11-11-4 5-11-12 5-11-12 11-11-9 5-11-12 0-0-44-11-130-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.58 0.11 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 34 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-10-15. (lb) - Max Horz 1=108(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-112(LC 6), 6=-112(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=296(LC 1), 8=373(LC 10), 6=373(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-315/155, 4-6=-315/155 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=112, 6=112. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V11 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153361 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:53 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-QUlE_I250yGc5TPhcmseCskIUfb4x26CK4WXHTzlBjS Scale = 1:25.6 1 2 3 43x6 4x6 3x6 2x4 0-0-5 0-0-5 9-1-6 9-1-1 4-6-11 4-6-11 9-1-6 4-6-11 0-0-43-9-90-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.44 0.21 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 24 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=223/9-0-12, 3=223/9-0-12, 4=384/9-0-12 Max Horz 1=80(LC 5) Max Uplift 1=-17(LC 6), 3=-21(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V12 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153362 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:54 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-ugJcBe3jnFOSjd_tAUOtk4HXi2zTgWMLZkF4qvzlBjR Scale = 1:11.7 1 2 3 4 2x4 4x6 2x4 2x4 0-0-5 0-0-5 4-3-12 4-3-7 2-1-14 2-1-14 4-3-12 2-1-14 0-0-41-9-90-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.16 0.08 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=102/4-3-3, 3=102/4-3-3, 4=147/4-3-3 Max Horz 1=-34(LC 4) Max Uplift 1=-12(LC 7), 3=-14(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V14 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153363 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:54 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-ugJcBe3jnFOSjd_tAUOtk4HT62ysgWmLZkF4qvzlBjR Scale = 1:19.2 1 2 3 2x4 2x4 2x4 3-2-14 3-2-14 0-0-43-2-1412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.39 0.18 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-2-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=137/3-2-10, 3=137/3-2-10 Max Horz 1=85(LC 6) Max Uplift 3=-52(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V15 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153364 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:55 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-Mst_Pz4LYZXJKmZ4kBv6HHpkUSKgPy0VnO?dMLzlBjQ Scale = 1:9.1 1 2 3 2x4 2x4 2x4 1-2-14 1-2-14 0-0-41-2-1412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.03 0.01 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 3 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-2-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=37/1-2-10, 3=37/1-2-10 Max Horz 1=23(LC 6) Max Uplift 3=-14(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V16 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153365 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:55 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-Mst_Pz4LYZXJKmZ4kBv6HHpeoSIkPyIVnO?dMLzlBjQ Scale = 1:18.4 1 2 3 5 4 2x4 4x6 2x4 2x4 2x4 4-3-13 4-3-13 3-1-5 3-1-5 4-3-13 1-2-8 0-0-43-1-51-10-1312.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.39 0.14 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-13 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=133/4-3-9, 4=39/4-3-9, 5=210/4-3-9 Max Horz 1=62(LC 6) Max Uplift 1=-3(LC 7), 4=-28(LC 7), 5=-5(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V17 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153366 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:55 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-Mst_Pz4LYZXJKmZ4kBv6HHphMSJfPyUVnO?dMLzlBjQ Scale = 1:15.2 1 2 3 5 4 2x4 4x6 2x4 2x4 2x4 3-7-15 3-7-15 2-5-7 2-5-7 3-7-15 1-2-8 0-0-42-5-71-2-1512.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.23 0.08 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-7-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=101/3-7-11, 4=45/3-7-11, 5=170/3-7-11 Max Horz 1=62(LC 5) Max Uplift 1=-18(LC 7), 4=-33(LC 7), 5=-17(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V18 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153367 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:56 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-q3RNcJ4zJtfAyw8GHvQLpVMu?sgP8P?e02kBuozlBjP Scale = 1:11.8 1 2 3 4 2x4 4x6 2x4 3x8 3-0-1 3-0-1 1-9-9 1-9-9 3-0-1 1-2-8 0-0-41-9-90-7-112.00 12 Plate Offsets (X,Y)-- [3:0-0-11,0-0-11], [3:0-1-6,0-3-11], [3:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.11 0.05 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud WEDGE Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=88/2-11-13, 4=99/2-11-13, 3=79/2-11-13 Max Horz 1=-34(LC 4) Max Uplift 1=-11(LC 7), 3=-11(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V19 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153368 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:56 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-q3RNcJ4zJtfAyw8GHvQLpVMrNseT8HGe02kBuozlBjP Scale = 1:47.3 1 2 3 4 5 6 7 12 11 10 9 8 2x4 3x6 4x6 3x4 2x4 2x4 3x4 2x4 2x4 2x4 11-0-0 11-0-0 -1-5-0 1-5-0 5-6-0 5-6-0 11-0-0 5-6-0 12-5-0 1-5-0 2-9-148-3-142-9-1412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.28 0.17 0.51 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.03 -0.05 0.00 0.03 (loc) 7 6-7 8 7 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 58 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 11-0-0. (lb) - Max Horz 12=219(LC 5) Max Uplift All uplift 100 lb or less at joint(s) except 12=-476(LC 4), 8=-120(LC 7), 11=-381(LC 5), 9=-124(LC 7) Max Grav All reactions 250 lb or less at joint(s) 8 except 12=426(LC 5), 10=584(LC 1), 11=427(LC 4), 9=419(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-12=-415/466, 3-4=-120/285, 4-5=-108/286 WEBS 4-10=-327/40, 3-11=-251/123, 2-11=-331/347 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 476 lb uplift at joint 12, 120 lb uplift at joint 8, 381 lb uplift at joint 11 and 124 lb uplift at joint 9. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V20 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153369 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:57 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-JF?lqf5c4An1a4jSrcxaMiv07G_htq9oFiUkQEzlBjO Scale = 1:40.5 1 2 3 4 5 8 7 63x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 0-0-4 0-0-4 12-7-12 12-7-8 6-3-14 6-3-14 12-7-12 6-3-14 0-0-46-3-140-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.28 0.11 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 43 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-7-4. (lb) - Max Horz 1=-139(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-147(LC 6), 6=-147(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=255(LC 1), 8=376(LC 10), 6=376(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-311/188, 4-6=-311/188 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=147, 6=147. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V21 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153370 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:58 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-nRZ71?6ErUvuCEHfPJSpuwR9tgIWcIKxUMDIzgzlBjN Scale = 1:29.3 1 2 3 43x6 4x6 3x6 2x4 8-7-8 8-7-8 8-7-12 0-0-4 4-3-14 4-3-14 8-7-12 4-3-14 0-0-44-3-140-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.40 0.20 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 24 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=226/8-7-4, 3=226/8-7-4, 4=342/8-7-4 Max Horz 1=-92(LC 4) Max Uplift 1=-18(LC 7), 3=-18(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19900447 Truss V22 Truss Type Valley Qty 1 Ply 1 McKenzie 284 Westvale Job Reference (optional) I36153371 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Feb 14 14:37:58 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:taVjvtMRPLbonO6z99JG03zlGUH-nRZ71?6ErUvuCEHfPJSpuwRC2gK5cJKxUMDIzgzlBjN Scale = 1:14.4 1 2 3 4 2x4 4x6 2x4 2x4 0-0-4 0-0-4 4-7-12 4-7-8 2-3-14 2-3-14 4-7-12 2-3-14 0-0-42-3-140-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.20 0.10 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=121/4-7-4, 3=121/4-7-4, 4=153/4-7-4 Max Horz 1=46(LC 5) Max Uplift 1=-16(LC 7), 3=-16(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. February 15,2019 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths