Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ALB45- Energy Cert
Energy Code Inspection Checklist Property Organization HERS Drees Homes TopBuild Home Services Projected Rating 14298 Millner Drive 866-912-7233 NA Carmel, IN 46032 Alan Smith Rating No:NA RaterID:3662662 Weather: Indianapolis, IN Builder Registry ID: CRESTWOOD BST CRL GAM BD4 Drees Homes DREIND-AP-CRESTWOOD BST CRL GAM BD4-09IECC.bIg Date: 2/18/2019 Building Information Conditioned Area (sq ft) 5865 Conditioned Volume (cubic ft) 59328 Insulated Shell Area (sq ft) 11019 The building assemblies and the energy features listed below have been modeled to demonstrate compliance with the IECC utilizing the Simulated Performance Path. At times the energy features listed below will change in the field from what has been input in the analysis. TopBuild Home Services's field inspection process will identify any changes to ensure that the home continues to meet the intent of the IECC. Reports and certificates will be furnished before CO to ensure that the house meets the intent of the IECC. Ceilings [ ] 1. Attic: R-40 Blown, Attic*** (2646 s.f.) R-27.0 continuous insulation, R-13.0 cavity insulation. Name: Flat Ceiling Insulation Grade: 1 II III Face /Inset Comments/ Location [ ] 2. Vaulted: R-38, Vaulted0** (102 s.f.) R-11.0 continuous insulation, R-27.0 cavity insulation. Name: SLOPPED Insulation Grade: 1 II III Face /Inset Comments/ Location Above -Grade Walls [ ] 1. Wall: R-15 (2x4) OSB*** (2748 s.f.), Between conditioned space and ambient R-0.0 continuous insulation, R-15.0 cavity insulation. Name: Exterior Insulation Grade: 1 II III Face /Inset Comments/ Location [ ] 2. Wall: R-15 (2x4)*** (327 s.f.), Between conditioned space and garage R-0.0 continuous insulation, R-15.0 cavity insulation. Name: Garage Insulation Grade: 1 II III Face /Inset Comments/ Location REM/Rate - Residential Energy Analysis and Rating Software v15.7 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. Energy Code Inspection Checklist Property Drees Homes 14298 Millner Drive Carmel, IN 46032 Weather: Indianapolis, IN CRESTWOOD BST CRL GAM BD4 DREIND-AP-CRESTWOOD BST CRL GAM BD4-091ECC.btg Organization HERS TopBuild Home Services Projected Rating 866-912-7233 NA Alan Smith Rating No:NA RaterID:3662662 Builder Registry ID: Drees Homes Date: 2/18/2019 Above -Grade Walls [ ] 3. Wall: R-15 (2x4)*** (652 s.f.), Between conditioned space and attic R-0.0 continuous insulation, R-15.0 cavity insulation. Name: Attic Insulation Grade: 1 II III Face /inset Comments/ Location Windows and Skylights Window -to -Wall Area Ratio: 0.15 [ ] 1. Window: U=.30 SHGC=.21*** (13 s.f., East), U -Value: 0.300, SHGC: 0.210 For windows without labeled U -factors, describe features: Name: 1 ST FRONT DR Orientation: East Comments/ Location [ ] 2. Window: U=.30 SHGC=.21*** (36 s.f., East), U -Value: 0.300, SHGC: 0.210 For windows without labeled U -factors, describe features: Name: 1ST FRONT Orientation: East Comments/ Location [ ] 3. Window: U=.30 SHGC=.21*** (36 s.f., East), U -Value: 0.300, SHGC: 0.210 For windows without labeled U -factors, describe features: Name: 1ST FRONT Orientation: East Comments/ Location [ ] 4. Window: U=.30 SHGC=.21*** (53 s.f., East), U -Value: 0.300, SHGC: 0.210 For windows without labeled U -factors, describe features: Name: 2ND FRONT Orientation: East Comments/ Location [ ] 5. Window: U=.30 SHGC=.21*** (16 s.f., South), U -Value: 0.300, SHGC: 0.210 For windows without labeled U -factors, describe features: Name: LEFT EGRESS Orientation: South Comments/ Location REM/Rate - Residential Energy Analysis and Rating Software v15.7 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. Page 2 of 7 Energy Code Inspection Checklist Property Drees Homes 14298 Millner Drive Carmel, IN 46032 Weather: Indianapolis, IN CRESTWOOD BST CRL GAM BD4 DREIND-AP-CRESTWOOD BST CRL GAM BD4-091ECC.b[g Organization HERS TopBuild Home Services Projected Rating 866-912-7233 NA Alan Smith Rating No:NA RaterID:3662662 Builder Registry ID: Drees Homes Date: 2/18/2019 Windows and Skylights [ ] 6. Window: U=.30 SHGC=.21*** (48 s.f., South), U -Value: 0.300, SHGC: 0.210 For windows without labeled U -factors, describe features: Name: 1 ST LEFT SGD Orientation: South Comments/ Location [ ] 7. Window: U=.30 SHGC=.21*** (20 s.f., South), U -Value: 0.300, SHGC: 0.210 For windows without labeled U -factors, describe features: Name: 1ST LEFT Orientation: South Comments/ Location [ ] 8. Window: U=.30 SHGC=.21*** (45 s.f., South), U -Value: 0.300, SHGC: 0.210 For windows without labeled U -factors, describe features: Name: 2ND LEFT Orientation: South Comments/ Location [ ] 9. Window: U=.30 SHGC=.21*** (44 s.f., West), U -Value: 0.300, SHGC: 0.210 For windows without labeled U -factors, describe features: Name: Back EGRESS Orientation: West Comments/ Location [ ] 10. Window: U=.30 SHGC=.21*** (126 s.f., West), U -Value: 0.300, SHGC: 0.210 For windows without labeled U -factors, describe features: Name: 1ST Back Orientation: West Comments/ Location [ ] 11. Window: U=.30 SHGC=.21*** (66 s.f., West), U -Value: 0.300, SHGC: 0.210 For windows without labeled U -factors, describe features: Name: 1ST Back Orientation: West Comments/ Location REM/Rate - Residential Energy Analysis and Rating Software v15.7 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. Page 3 of 7 Energy Code Inspection Checklist Property Drees Homes 14298 Millner Drive Carmel, IN 46032 Weather: Indianapolis, IN CRESTWOOD BST CRL GAM BD4 DREIND-AP-CRESTWOOD BST CRL GAM BD4-091ECC.b[g Organization HERS TopBuild Home Services Projected Rating 866-912-7233 NA Alan Smith Rating No:NA RaterID:3662662 Builder Registry ID: Drees Homes Date: 2/18/2019 Windows and Skylights [ ] 12. Window: U=.30 SHGC=.21*** (22 s.f., West), U -Value: 0.300, SHGC: 0.210 For windows without labeled U -factors, describe features: Name: 1ST Back Orientation: West Comments/ Location [ ] 13. Window: U=.30 SHGC=.21*** (22 s.f., North), U -Value: 0.300, SHGC: 0.210 For windows without labeled U -factors, describe features: Name: 1ST Right Orientation: North Comments/ Location Doors [ ] 1. Door: Steel-urth w/brk***** (11 s.f.), R -Value 4.4 Comments/ Location [ ] 2. Door: Steel-urth w/brk***** (20 s.f.), R -Value 4.4 Comments/ Location [ ] 3. Door: Steel-urth w/brk***** (18 s.f.), R -Value 4.4 Comments/ Location Frame Floors [ ] 1. Floor: Uninsulated (531 s.f.), Between conditioned space and enclosed crawl space R-0.0 continuous insulation, R-0.0 cavity insulation. Name: Over CRL Insulation Grade: 1 II III Face /Inset Comments/ Location Slab Floors [ ] 1. Slab: Uninsulated*** (2217 s.f.) R-0.0 perimeter insulation, R-0.0 under slab insulation. Name: Slab Insulation Grade: 1 II III Face /Inset Comments/ Location REM/Rate - Residential Energy Analysis and Rating Software v15.7 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. Page 4 of 7 Energy Code Inspection Checklist Property Drees Homes 14298 Millner Drive Carmel, IN 46032 Weather: Indianapolis, IN CRESTWOOD BST CRL GAM BD4 DREIND-AP-CRESTWOOD BST CRL GAM BD4-091ECC.btg Organization HERS TopBuild Home Services Projected Rating 866-912-7233 NA Alan Smith Rating No:NA RaterID:3662662 Builder Registry ID: Drees Homes Date: 2/18/2019 Foundation Walls [ ] 1. Wall: R-11 Draped, 4ft****0* (1543 s.f.), Between conditioned space and ambient/ground R-11.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: Below -Grade Insulation Grade: 1 II III Face /inset Comments/ Location [ ] 2. Wall: R-11 Draped, 4ft****0* (209 s.f.), Between enclosed crawl space and ambient/ground R-11.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: CRL Insulation Grade: 1 II III Face /Inset Comments/ Location [ ] 3. Wall: R-11 Draped, 4ft****0* (56 s.f.), Between enclosed crawl space and garage/ground R-11.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: CRL GAR Insulation Grade: 1 II III Face /inset Comments/ Location [ ] 4. Wall: R-11 Draped, 4ft****0* (205 s.f.), Between conditioned space and garage/ground R-11.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: Garage Insulation Grade: 1 II III Face /Inset Comments/ Location Rim and Band Joists [ ] 1. Joist: Ambient (227 s.f.), Between conditioned space and ambient R-0.0 continuous insulation, R-15.0 cavity insulation. Name: Ambient Insulation Grade: 1 II III Face /inset Comments/ Location [ ] 2. Joist: Attic (88 s.f.), Between conditioned space and attic R-0.0 continuous insulation, R-15.0 cavity insulation. Name: Attic Insulation Grade: 1 II III Face /inset Comments/ Location REM/Rate - Residential Energy Analysis and Rating Software v15.7 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. Page 5 of 7 Energy Code Inspection Checklist Property Organization HERS Drees Homes TopBuild Home Services Projected Rating 14298 Millner Drive 866-912-7233 NA Carmel, IN 46032 Alan Smith Rating No:NA RaterID:3662662 Weather: Indianapolis, IN Builder Registry ID: CRESTWOOD BST CRL GAM BD4 Drees Homes DREIND-AP-CRESTWOOD BST CRL GAM BD4-09IECC.bIg Date: 2/18/2019 Mechanical Equipment [ ] 1. Water Heating: Conventional, Natural gas, 0.65 EF, 50.0 Gal. Make and Model Number [ ] 2. Heating: Fuel -fired air distribution, Natural gas, 93.0 AFUE. Make and Model Number [ ] 3. Cooling: Air conditioner, Electric, 13.0 SEER. Make and Model Number Mechanical Ventilation System [ ] Mechanical ventilation system rated for, and capable of, providing continuous ventilation. System shall include automatic timing controls. System type: Exhaust Only, 224 cfm, 11.9 hrs/day, 22.5 watts. System description (make) Air Leakage Control [ ] Blower Door Test at Final [ ] House is air -sealed so as to achieve 1.37 ELA/100sh or less at final blower door test. (Max CFM50 is: 2750) [ ] Visual inspection at rough for mandatory code air barrier and insulation features. Infiltration Requirements for IECC 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015-2018 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage (if not exempt from testing) [ ] Duct System 1 Leakage to Outside and Total Duct Leakage [ ] Duct System 1 Leakage to Outside is specified in REM/Rate at 0.030 CFM25 / CFA [ ] Duct System 1 Total Duct Leakage is specified in REM/Rate at 0.040 CFM25 / CFA Duct Leakage Code Requirements for IECC 2009 1 ECC: REM/Rate - Residential Energy Analysis and Rating Software v15.7 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. Page 6 of 7 Energy Code Inspection Checklist Property Drees Homes 14298 Millner Drive Carmel, IN 46032 Weather: Indianapolis, IN CRESTWOOD BST CRL GAM BD4 DREIND-AP-CRESTWOOD BST CRL GAM BD4-091ECC.b[g Organization HERS TopBuild Home Services Projected Rating 866-912-7233 NA Alan Smith Rating No:NA RaterID:3662662 Builder Registry ID: Drees Homes Duct Leakage Code Requirements for IECC Notes Date: 2/18/2019 Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and Prescriptive Path for 2015-2018 IECC: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015-2018 IECC Performance Path (Cost Compliance): Requires ducts be tested and reported, but has no compliance thresholds. REM/Rate - Residential Energy Analysis and Rating Software v15.7 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. Page 7 of 7 2009 IECC Energy Cost Compliance Property Drees Homes 14298 Millner Drive Carmel, IN 46032 Weather: Indianapolis, IN CRESTWOOD BST CRL GAM BD4 DREIND-AP-CRESTWOOD BST CRL Annual Energy Cost Organization TopBuild Home Services 866-912-7233 Alan Smith Builder Drees Homes Heating Cooling Water Heating SubTotal - Used to Determine Compliance HERS Projected Rating NA Rating No:NA RaterID:3662662 2009 1 ECC 311 167 49 527 $/yr As Designed 277 134 49 460 Mechanical Ventilation Fan 24 6 Lights Ft Appliances (minus MechVent) 676 687 Photovoltaics -0 -0 Service Charge 248 248 Total 1475 1401 Mandatory Requirements Annual Energy Cost Check PASSES Duct Insulation R -Value Check (per Section 405.2) PASSES Window U -Value and SHGC Check (per Section 402.5) PASSES Home Infiltration (Section 402.4.2) PASSES Duct Leakage (Section 403.2.2) PASSES Mandatory Requirements Check Box (2009 IECC) PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code based on a climate zone of 5A. In fact, this home surpasses the requirements by 12.8%. Name Alan Smith Organization TopBuild Home Services Signature Date 18 February 2019 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v15.7 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 14298 Millner Drive, Carmel, IN by Drees Homes exceeds the minimum requirements for the 2009 International Energy Conservation Code Ceiling Flat R-40.0 Sealed Attic: NA Vaulted Ceiling R-38.0 Above Grade Walls R-15.0 Foundation Walls R-11.0 Exposed Floor R-0.0 Slab R-0.0 Edge, R-0.0 Under Building Features Duct Duct Leakage to Outside: Total Duct Leakage: Infiltration: Window Heating Cooling Water Heating NA 0.03 CFM25 / CFA 0.04 CFM25 / CFA Htg: 1.37 Clg: 1.37 ELA/100sh U -Value: 0.300, SHGC: 0.210 Fuel -fired air distribution, Natural gas, 93.0 AFUE. Air conditioner, Electric, 13.0 SEER. Conventional, Natural gas, 0.65 EF, 50.0 Gal. The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in compliance with Chapter 4 based on Climate Zone 5A and with all mandatory requirements. Name Alan Smith Organization TopBuild Home Services Signature Date 18 February 2019 The 2009 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC"). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software v15.7