HomeMy WebLinkAbout651FA - Energy CertHOME CERTIFIED TO MEET THE PROVISIONS OF THE
2009 INTERNATIONAL ENERGY CONSERVATION CODE
This home built at
651 1st Avenue NE, Carmel, IN
by Wedgewood Building Co., LLC.
exceeds the minimum requirements for the 2009 International
Energy Conservation Code
The 2009 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( “ICC”).
No version of this software has been reviewed or approved by ICC or its affiliates.
REM/Rate - Residential Energy Analysis and Rating Software v15.7
The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in compliance with
Chapter 4 based on Climate Zone 5A and with all mandatory requirements.
Building Features
Ceiling Flat R-38.0 Duct NA
Sealed Attic: NA Duct Leakage to Outside: 252.00 CFM @ 25 Pascals
Vaulted Ceiling NA Total Duct Leakage: 432.00 CFM @ 25 Pascals
Above Grade Walls R-18.0 Infiltration: Htg: 6.00 Clg: 6.00 ACH50
Foundation Walls R-14.0 Window U-Value: 0.300, SHGC: 0.290
Exposed Floor NA Heating Fuel-fired air distribution, Natural gas, 95.0 AFUE.
Slab R-0.0 Edge, R-0.0 Under Cooling Air conditioner, Electric, 14.0 SEER.
Water Heating Conventional, Natural gas, 0.70 EF, 50.0 Gal.
Name Ian Carstairs Signature
Organization IC Energy Services Date 27 November 2018