Loading...
HomeMy WebLinkAboutLEGACY PRAIRIE 1504 - LP1504 (AS DESIGNED)IECC 2009 Performance Compliance Property 7258 ZANESVILLE RD CARMEL, IN 46033 LP1504 (AS DESIGNED) LEGACY PRAIRIE 1504 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,000 $141 $350 $1,491 S583 so $2,074 Requirements C4405.3 Performance-based compliance passes by 15.3% 402.4.1.2 Air Leakage Testing 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U -Factor 40322 Duct. Testing C4 Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation C-M, Energy Solutions As Designed $767 $146 $350 $1,263 $583 $0 $1,846 Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa. Design exceeds requirements for IECC 2009 Performance compliance by 15.3%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Signature: Organization: TSI Energy Solutions Digitally signed: 2120119 at 10:25 AM Ekotrope RATER - Version 3.1.0.2112 IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool. 7258 ZANESVILLE RD CARMEL, IN 46033 LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls NIA Framed Floor R-38 Slab R-10.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U -Value: 0.32, SHGC: 0.34 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 118.0 CFM @ 25Pa Total Duct Leakage 189.0 CFM @ 25Pa Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another palv. — -1-0 Name: Matthew Timmons Signature Organization: TSI Energy Solutions Digitally signed: 2120f19 at 10:25 AM Ekotrope RATER - Version 3.1.0.2112 No version of this software has been reviewed or approved by ICC or its affiliates. The 2009 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ('ICC'). Thissoftwareis a RESIN ETAccredited HERS Rating Tool. Energy Code Inspection Checklist Property 7268 ZANESVILLE RD CARMEL, IN 46033 LP1504 (AS DESIGNED) LEGACY PRAIRIE 1604 General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 2,364 19,776 6,374 Inspection Status Results are projected C-M, Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identity any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB 1 (536 s.f.) R-10 perimeter insulation, R-0 under slab insulation. Name: SLAB 2 (66 s.f.) R-10 perimeter insulation, R-0 under slab insulation. Framed Floor El Name: OVER GARAGE (411 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall None Present Alcove Grade Wall El Name: CONDIAMB (1,706 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIAMB 2X6 (277 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I Name: CONDIGAR (240 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property Organization 7258 ZANESVILLE RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons LP1504 (AS DESIGNED) Builder LEGACY PRAIRIE 1504 LENNAR HOMES El Name: CONDIGAR 2X6 (112 s.f.) R-0 continuous insulation, R-19 cavity insulation Insulation Grade: I Name: COND/COND (832 s.f.) R-0 continuous insulation, R-22 cavity insulation Insulation Grade: I Rim Joist Name: CONDIAMB (145 s.f.) R: 13.575 El Name: CONDIGAR (44 s.f.) R: 10.876 Name: CONDICOND (59 s.f.) R: 10.876 Roof El Name: MAIN (946 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door El Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected El Name: FRONT (99 s.f.), U:0.320, SHGC: 0.34, Orientation: EAST El Name: BACK (114 s.f.), U:0.320, SHGC: 0.34, Orientation: WEST C", Energy Solutions 2 Energy Code Inspection Checklist C-M Energy Solutions Property Organization 7258 ZANESVILLE RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Inspection Status Results are projected LP1504 (AS DESIGNED) Builder LEGACY PRAIRIE 1504 LEN NAR HOMES E] Name: SLIDER [33 s.f.), U:0.320, SHGC: 0.34, Orientation: WEST E] Name: GD (20 s.f.), U:0.320, SHGC: 0.34, Orientation: WEST E] Name: RIGHT SIDE (74 s.f.), U:0.320, SHGC: 0.34, Orientation: NORTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment U Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 95.5 AFUE Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Slower -door tested House is air -sealed as to achieve 1,648 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. 3 Energy Code Inspection Checklist Property 7258 ZANESVILLE RD CARMEL, IN 46033 LP1504 (AS DESIGNED) LEGACY PRAIRIE 1504 Duct Leakage Duct System 1 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 118.0 CFM @ 25 Pa Total Duct Leakage is specified in Ekotrope at 189.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property Organization 7258 ZANESVILLE RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Name Library Type Perimeter Inspection Status LP1504 [AS DESIGNED] Builder Results are projected LEGACY PRAIRIE 1504 LENNAR HOMES General Building Information MM Masonry Area Number Of Bedrooms 3 Number Of Floors 3 Conditioned Floor Area [sq. ft.] 2;364 Unconditioned, attached garage? Yes Conditioned Volume [cu. ft.] 19;776 Total Units in Building 1 Residence Type Townhouse; end unit Model FOXHALL Community LEGACY PRAIRIE 1505 Climate Zone 5A Basement Wall Am None Present Basement Wall Library List None Present C-M, Energy Solutions Slab Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area SLAB 1 R-10, 2'down 72 On Grade 1.23 0 536.0 sq. ft. Exposed Exterior Conditioned Space SLAB 2 R-10, 2'down 35 On Grade 1.23 0 66.0 sq. ft Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Type Slab Completely Underslab Insulation Perimeter Insulation Perimeter Insulation R R -value Insulated. Width [ft] Depth 1111 Value IR-10, 2'down Wood Frame / Other No 0 2 10 0.00 Framed Floor Name Library Type IOVER Carpet R Floor Grade Surface Area Location GARAGE R-38, GR1 1.23 Above Grade 411.0 sq. ft Unconditioned, attached garage 1 Building Summary Property Organization 7258 ZANESVILLE RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons LP1504 [AS DESIGNED] Builder LEGACY PRAIRIE 1504 LENNAR HOMES ramed Floor Library List Name R -value 1,706.0 sq. ft. Exposed Exterior 33.825 G1 R-19, R-3 -0 2X6 Rim Joist 277.0 sq. ft. Name Library Type CONDIAMB Medium G1 R-13, R-3.0 CONDICOND CONDIGAR G1 R-13, OSB CONDIGAR 240.0 sq. ft. G1 R-13, OSB :ONDIGAR 2X6 Rim Joist Library List Medium Name R -value G1 R-13, OSB 10.876 G1 R-13, R-3.0 13.575 Inspection Status Results are projected 145.0 sq. ft. C-M, Energy Solutions Exposed Exterior 59.0 sq. ft. Conditioned Space (Adiabatic) 44.0 sq. ft. Unconditioned, attached garage I Name Library Type Surface Calor Surface Area Location CONDIAMB G1 R-13 BATT, R-3.0 Medium 1,706.0 sq. ft. Exposed Exterior :OND/AMB 2X6 G1 R-19, R-3 -0 2X6 Medium 277.0 sq. ft. Exposed Exterior CONDICOND G1 R-22 Dbl Wall Medium 832.0 sq. ft. Conditioned Space [Adiabatic] CONDIGAR G1 R-13 Gar Walls Medium 240.0 sq. ft. Unconditioned, attached garage :ONDIGAR 2X6 G1 R-19, 2x6 GAR Medium 112.0 sq. ft. Unconditioned, attached garage 2 Building Summary Property Organization C-MEnergy Solutions 7258 ZANESVILLE RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Inspection Status LP1504 [AS DESIGNED] Builder Results are projected LEGACY PRAIRIE 1504 LENNAR HOMES ibrary List Name R -value G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 G1 R-19, 2x6 GAR 16218 G1 R-19, R-3.0 2X6 20217 G1 R-22 Dhl Wall 18.407 Glazing Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Pt To Overhang Pt To Orientation Surface Area Assignment Tbp Bottom BACK U-.32, SHGG.34 CONDIAMB ❑ ❑ ❑ West 114.0 sq. ft. FRONT U-.32, SHGG.34 CONDIAMB ❑ ❑ ❑ East 99.0 sq. ft GD U-.32, SHGG.34 CONDIAMB 2X6 0 0 ❑ West 20.0 sq. 1 RIGHT SIDE U-.32, SHGG.34 CONDIAMB ❑ 0 ❑ North 74.0 sq. 1 SLIDER U-32, SHGG.34 CONDIAMB ❑ ❑ ❑ West 33.0 sq. ft Glazing Library List Name Shgc U -factor U-32, SHGC-.34 0.34 0.320 Skylight Skylight Library List None Present Building Summary Property Organization 7258 ZANESVILLE RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons LP1504 [AS DESIGNED] Builder LEGACY PRAIRIE 1504 LENNAR HOMES POpaque Door Name FRONT Steel Door CONDIAMB 2706 GARAGE Steel Door CONDIGAR 2X6 C-M, Energy Solutions Inspection Status Results are projected Opaque Door Library List JL Name U -factor Steel Door 0.182 0.9 0.75 Medium 20.0 sq. ft Exposed Exterior 0.9 0.75 Medium 18.0 sq. ft Exposed Exterior Roof Insulation Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color P.f.] Tiles MAIN RIR PU— r,R1 qAr IJ, M.,Ih m Roof Insulation Library List Name Has Radiant Barrier '•0 .a l No Whole House Infiltratio Infiltration Measurement Type 5 ACH at 50 Pa Blower -door tested Mechanical Ventilation None Present RAalue 38268 4 SurfaceArea Location 946.0 sq. R Attic M Building Summary Property 7258 ZANESVILLE RD CARMEL, IN 46033 LP1504 (AS DESIGNED) LEGACY PRAIRIE 1504 Righting % Interior Fluore. Lig Onsite Generation Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected C-M, Energy Solutions 100 0 100 0 100 Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present Conditioning Equipment Name Library Type Heating Percent Load Air conditioner (2) CA13NA036 0% Fuel -fired air 9155A4808OS17 100% distribution (1) Water Heating (3) RE350" 0% Cooling Percent Load Hot Water Percent Load 100% 0% 0% 0% 0% 100% Building Summary Property 7258 ZANESVILLE RD CARMEL, IN 46033 LP1504 [AS DESIGNED] LEGACY PRAIRIE 1504 quipment Type: Fuel Type Distribution Type Motor Type Heating Efficiency Heating Capacity [kBtulh] Use default EAE EAE [kWh] Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 915 5A4808O S i Equipment Type: CA13NA036 Fuel Type Distribution Type Motor Type Cooling Efficiency Cooling Capacity [kBtulh] quipment Type: RE350* Fuel Type Distribution Type Hot Water Efficiency Tank Capacity {gal.] Hot Water Capacity [kBtulh] Recovery Efficiency Natural Gas Forced Air PSG (Single Speed) 95.5 AFUE 78 No 946 Electric Forced Air PSG (Single Speed) 13 SEER 34.2 Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 Inspection Status Results are projected C-M, Energy Solutions Building Summary Property Organization 7258 ZANESVILLE RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Sq. Feet Served Inspection Status LP1504 [AS DESIGNED] Builder Results are projected LEGACY PRAIRIE 1504 LENNAR HOMES istribution System Distribution Type Forced Air Heating Equipment Fuel -f red air distribution [1) Cooling Equipment Air conditioner (2) Sq. Feet Served 2364 # Return Grilles 2 Supply Duct R Value 30 Return Duct R Value 30 Supply Duct Area [sq. ft.] 478.7 Return Duct Area [sq. ft_] 177.3 Duct Leakage to Outdoors (CFM25) 118 Total Leakage 189 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct t Duct Location Conditioned Space Percent Supply Area 50 Percent Return Area 50 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area 50 Percent Return Area 50 Duct 3 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Ceiling Fan ' Has Ceiling Fan No Cfm Per Watt 101 Water Distribution Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 86 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 34 Drain Water Heat Recovery? No C-M, Energy Solutions Building Summary Property 7258 ZANESVILLE RD CARMEL, IN 46033 LP1504 [AS DESIGNED] LEGACY PRAIRIE 1504 Fuel Type Cef Field Utilization lothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I mef Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption "M Organization TSI Energy Solutions Matthew Timmons Inspection Status Builder Results are projected LENNAR HOMES Electric Timer Controls 704 kWh/Year 0.0nWh $23.00 $0.581Therm 2.874 0.331 Yes Standard 270 kWh Electric No No 709 kWh/Year C-M, Energy Solutions ,�