HomeMy WebLinkAboutLEGACY PRAIRIE 1504 - LP1504 (AS DESIGNED)IECC 2009 Performance Compliance
Property
7258 ZANESVILLE RD
CARMEL, IN 46033
LP1504 (AS DESIGNED)
LEGACY PRAIRIE 1504
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$1,000
$141
$350
$1,491
S583
so
$2,074
Requirements
C4405.3
Performance-based compliance passes by 15.3%
402.4.1.2
Air Leakage Testing
402.5
Area -weighted average fenestration SHGC
402.5
Area -weighted average fenestration U -Factor
40322
Duct. Testing
C4
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052
Duct Insulation
C-M,
Energy Solutions
As Designed
$767
$146
$350
$1,263
$583
$0
$1,846
Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa.
Design exceeds requirements for IECC 2009 Performance compliance by 15.3%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons Signature:
Organization: TSI Energy Solutions Digitally signed: 2120119 at 10:25 AM
Ekotrope RATER - Version 3.1.0.2112
IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool.
7258 ZANESVILLE RD
CARMEL, IN 46033
LENNAR HOMES
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls NIA
Framed Floor R-38
Slab R-10.0 Perimeter, R-0.0
Under
Infiltration 5 ACH50
Window U -Value: 0.32, SHGC: 0.34
Building Features
Duct Supply R-30.0, Return R-30.0
Duct Leakage to Outside 118.0 CFM @ 25Pa
Total Duct Leakage 189.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 95.5 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another palv. — -1-0
Name: Matthew Timmons Signature
Organization: TSI Energy Solutions
Digitally signed: 2120f19 at 10:25 AM
Ekotrope RATER - Version 3.1.0.2112
No version of this software has been reviewed or approved by ICC or its affiliates.
The 2009 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ('ICC').
Thissoftwareis a RESIN ETAccredited HERS Rating Tool.
Energy Code Inspection Checklist
Property
7268 ZANESVILLE RD
CARMEL, IN 46033
LP1504 (AS DESIGNED)
LEGACY PRAIRIE 1604
General Building Information
Conditioned Area (sq ft)
Conditioned Volume (cubic ft)
Insulated Shell Area (sq ft)
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
2,364
19,776
6,374
Inspection Status
Results are projected
C-M,
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identity any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: SLAB 1 (536 s.f.)
R-10 perimeter insulation, R-0 under slab insulation.
Name: SLAB 2 (66 s.f.)
R-10 perimeter insulation, R-0 under slab insulation.
Framed Floor
El Name: OVER GARAGE (411 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Foundation Wall
None Present
Alcove Grade Wall
El Name: CONDIAMB (1,706 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CONDIAMB 2X6 (277 s.f.)
R-3 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Name: CONDIGAR (240 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property Organization
7258 ZANESVILLE RD TSI Energy Solutions
CARMEL, IN 46033 Matthew Timmons
LP1504 (AS DESIGNED) Builder
LEGACY PRAIRIE 1504 LENNAR HOMES
El Name: CONDIGAR 2X6 (112 s.f.)
R-0 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Name: COND/COND (832 s.f.)
R-0 continuous insulation, R-22 cavity insulation
Insulation Grade: I
Rim Joist
Name: CONDIAMB (145 s.f.)
R: 13.575
El Name: CONDIGAR (44 s.f.)
R: 10.876
Name: CONDICOND (59 s.f.)
R: 10.876
Roof
El Name: MAIN (946 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
El Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
El Name: FRONT (99 s.f.), U:0.320, SHGC: 0.34, Orientation: EAST
El Name: BACK (114 s.f.), U:0.320, SHGC: 0.34, Orientation: WEST
C",
Energy Solutions
2
Energy Code Inspection Checklist
C-M
Energy Solutions
Property Organization
7258 ZANESVILLE RD TSI Energy Solutions
CARMEL, IN 46033 Matthew Timmons Inspection Status
Results are projected
LP1504 (AS DESIGNED) Builder
LEGACY PRAIRIE 1504 LEN NAR HOMES
E] Name: SLIDER [33 s.f.), U:0.320, SHGC: 0.34, Orientation: WEST
E] Name: GD (20 s.f.), U:0.320, SHGC: 0.34, Orientation: WEST
E] Name: RIGHT SIDE (74 s.f.), U:0.320, SHGC: 0.34, Orientation: NORTH
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
U Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 95.5 AFUE
Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER
Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Slower -door tested
House is air -sealed as to achieve 1,648 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
3
Energy Code Inspection Checklist
Property
7258 ZANESVILLE RD
CARMEL, IN 46033
LP1504 (AS DESIGNED)
LEGACY PRAIRIE 1504
Duct Leakage
Duct System 1
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 118.0 CFM @ 25 Pa
Total Duct Leakage is specified in Ekotrope at 189.0 CFM @ 25Pa
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
Organization
7258 ZANESVILLE RD
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
Name Library Type Perimeter
Inspection Status
LP1504 [AS DESIGNED]
Builder Results are projected
LEGACY PRAIRIE 1504
LENNAR HOMES
General Building Information
MM
Masonry Area
Number Of Bedrooms
3
Number Of Floors
3
Conditioned Floor Area [sq. ft.]
2;364
Unconditioned, attached garage?
Yes
Conditioned Volume [cu. ft.]
19;776
Total Units in Building
1
Residence Type
Townhouse; end unit
Model
FOXHALL
Community
LEGACY PRAIRIE 1505
Climate Zone
5A
Basement Wall
Am
None Present
Basement Wall Library List
None Present
C-M,
Energy Solutions
Slab
Name Library Type Perimeter
Floor Grade
Carpet R
Exposed
Surface Area Location
Enclosing
Masonry Area
SLAB 1 R-10, 2'down 72
On Grade
1.23
0
536.0 sq. ft. Exposed Exterior
Conditioned
Space
SLAB 2 R-10, 2'down 35
On Grade
1.23
0
66.0 sq. ft Exposed Exterior
Conditioned
Space
Slab Library List
Name Wall Construction Type Slab Completely
Underslab
Insulation
Perimeter Insulation
Perimeter Insulation R
R -value
Insulated.
Width [ft]
Depth 1111 Value
IR-10, 2'down Wood Frame / Other
No
0
2 10
0.00
Framed Floor
Name Library Type
IOVER
Carpet R
Floor Grade
Surface Area
Location
GARAGE R-38, GR1
1.23
Above Grade
411.0 sq. ft Unconditioned, attached
garage
1
Building Summary
Property
Organization
7258 ZANESVILLE RD
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
LP1504 [AS DESIGNED]
Builder
LEGACY PRAIRIE 1504
LENNAR HOMES
ramed Floor Library List
Name
R -value
1,706.0 sq. ft.
Exposed Exterior
33.825
G1 R-19, R-3 -0 2X6
Rim Joist
277.0 sq. ft.
Name
Library Type
CONDIAMB
Medium
G1 R-13, R-3.0
CONDICOND
CONDIGAR
G1 R-13, OSB
CONDIGAR
240.0 sq. ft.
G1 R-13, OSB
:ONDIGAR 2X6
Rim Joist Library List
Medium
Name
R -value
G1 R-13, OSB
10.876
G1 R-13, R-3.0
13.575
Inspection Status
Results are projected
145.0 sq. ft.
C-M,
Energy Solutions
Exposed Exterior
59.0 sq. ft. Conditioned Space (Adiabatic)
44.0 sq. ft. Unconditioned, attached garage
I
Name
Library Type
Surface Calor
Surface Area
Location
CONDIAMB
G1 R-13 BATT, R-3.0
Medium
1,706.0 sq. ft.
Exposed Exterior
:OND/AMB 2X6
G1 R-19, R-3 -0 2X6
Medium
277.0 sq. ft.
Exposed Exterior
CONDICOND
G1 R-22 Dbl Wall
Medium
832.0 sq. ft.
Conditioned Space [Adiabatic]
CONDIGAR
G1 R-13 Gar Walls
Medium
240.0 sq. ft.
Unconditioned, attached garage
:ONDIGAR 2X6
G1 R-19, 2x6 GAR
Medium
112.0 sq. ft.
Unconditioned, attached garage
2
Building Summary
Property
Organization
C-MEnergy
Solutions
7258 ZANESVILLE RD
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
Inspection Status
LP1504 [AS DESIGNED]
Builder
Results are projected
LEGACY PRAIRIE 1504
LENNAR HOMES
ibrary List
Name
R -value
G1 R-13 BATT, R-3.0
15.12
G1 R-13 Gar Walls
11.141
G1 R-19, 2x6 GAR
16218
G1 R-19, R-3.0 2X6
20217
G1 R-22 Dhl Wall
18.407
Glazing
Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Pt To
Overhang Pt To
Orientation
Surface Area
Assignment
Tbp
Bottom
BACK U-.32, SHGG.34
CONDIAMB
❑ ❑
❑
West
114.0 sq. ft.
FRONT U-.32, SHGG.34
CONDIAMB
❑ ❑
❑
East
99.0 sq. ft
GD U-.32, SHGG.34 CONDIAMB 2X6
0 0
❑
West
20.0 sq. 1
RIGHT SIDE U-.32, SHGG.34
CONDIAMB
❑ 0
❑
North
74.0 sq. 1
SLIDER U-32, SHGG.34
CONDIAMB
❑ ❑
❑
West
33.0 sq. ft
Glazing Library List
Name
Shgc
U -factor
U-32, SHGC-.34
0.34
0.320
Skylight
Skylight Library List
None Present
Building Summary
Property
Organization
7258 ZANESVILLE RD
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
LP1504 [AS DESIGNED]
Builder
LEGACY PRAIRIE 1504
LENNAR HOMES
POpaque Door
Name
FRONT Steel Door CONDIAMB 2706
GARAGE Steel Door CONDIGAR 2X6
C-M,
Energy Solutions
Inspection Status
Results are projected
Opaque Door Library List
JL
Name U -factor
Steel Door 0.182
0.9 0.75 Medium 20.0 sq. ft Exposed Exterior
0.9 0.75 Medium 18.0 sq. ft Exposed Exterior
Roof Insulation
Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color
P.f.] Tiles
MAIN RIR PU— r,R1 qAr IJ, M.,Ih m
Roof Insulation Library List
Name Has Radiant Barrier
'•0 .a l No
Whole House Infiltratio
Infiltration Measurement Type
5 ACH at 50 Pa Blower -door tested
Mechanical Ventilation
None Present
RAalue
38268
4
SurfaceArea Location
946.0 sq. R Attic
M
Building Summary
Property
7258 ZANESVILLE RD
CARMEL, IN 46033
LP1504 (AS DESIGNED)
LEGACY PRAIRIE 1504
Righting
% Interior Fluore.
Lig
Onsite Generation
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
C-M,
Energy Solutions
100 0 100 0 100
Onsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
Conditioning Equipment
Name Library Type Heating Percent Load
Air conditioner (2) CA13NA036 0%
Fuel -fired air 9155A4808OS17 100%
distribution (1)
Water Heating (3) RE350" 0%
Cooling Percent Load Hot Water Percent Load
100%
0%
0%
0%
0% 100%
Building Summary
Property
7258 ZANESVILLE RD
CARMEL, IN 46033
LP1504 [AS DESIGNED]
LEGACY PRAIRIE 1504
quipment Type:
Fuel Type
Distribution Type
Motor Type
Heating Efficiency
Heating Capacity [kBtulh]
Use default EAE
EAE [kWh]
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
915 5A4808O S i
Equipment Type: CA13NA036
Fuel Type
Distribution Type
Motor Type
Cooling Efficiency
Cooling Capacity [kBtulh]
quipment Type: RE350*
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity {gal.]
Hot Water Capacity [kBtulh]
Recovery Efficiency
Natural Gas
Forced Air
PSG (Single Speed)
95.5 AFUE
78
No
946
Electric
Forced Air
PSG (Single Speed)
13 SEER
34.2
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
0.98
Inspection Status
Results are projected
C-M,
Energy Solutions
Building Summary
Property
Organization
7258 ZANESVILLE RD
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
Sq. Feet Served
Inspection Status
LP1504 [AS DESIGNED]
Builder Results are projected
LEGACY PRAIRIE 1504
LENNAR HOMES
istribution System
Distribution Type
Forced Air
Heating Equipment
Fuel -f red air distribution [1)
Cooling Equipment
Air conditioner (2)
Sq. Feet Served
2364
# Return Grilles
2
Supply Duct R Value
30
Return Duct R Value
30
Supply Duct Area [sq. ft.]
478.7
Return Duct Area [sq. ft_]
177.3
Duct Leakage to Outdoors (CFM25)
118
Total Leakage
189
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct t
Duct Location
Conditioned Space
Percent Supply Area
50
Percent Return Area
50
Duct 2
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
50
Percent Return Area
50
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Ceiling Fan
'
Has Ceiling Fan
No
Cfm Per Watt
101
Water Distribution
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
86
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft]
34
Drain Water Heat Recovery?
No
C-M,
Energy Solutions
Building Summary
Property
7258 ZANESVILLE RD
CARMEL, IN 46033
LP1504 [AS DESIGNED]
LEGACY PRAIRIE 1504
Fuel Type
Cef
Field Utilization
lothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I mef
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
"M
Organization
TSI Energy Solutions
Matthew Timmons
Inspection Status
Builder Results are projected
LENNAR HOMES
Electric
Timer Controls
704 kWh/Year
0.0nWh
$23.00
$0.581Therm
2.874
0.331
Yes
Standard
270 kWh
Electric
No
No
709 kWh/Year
C-M,
Energy Solutions
,�