HomeMy WebLinkAboutOBF-095 ENERGYIECC 2009 Performance Compliance Property 3914 BEAR CREEK WAY CARMEL, IN 46074 OBF095 (AS DESIGNED) OVERBROOK FARMS 95 Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder FISCHER HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance S1,650 S218 5411 $2,279 $1,303 $0 $3,582 Requirements C4405.3 Performance-based compliance passes by 2.0% 402.4.12 Air Leakage Testing C4402.5 Area -weighted average fenestration SHGG 402.5 Area -weighted average fenestration U -Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation C-M, Energy Solutions As Designed $1,621 $200 $411 $2,233 $1,303 $0 $3,536 Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa. Design exceeds requirements for IECC 2009 Performance compliance by 2%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Michael Hill Organization: TSI Energy Solutions Signature: Date: 2111119 at 11:23 AM Ekotrope RATER - Version 3.1.0.2106 IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool. 3914 BEAR CREEK WAY CARMEL, IN 46074 FISCHER HOMES Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls R-11 Framed Floor NIA Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U -Value: 0.31, SHGC: 0.29 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 260.0 CFM @ 25Pa Total Duct Leakage 509.0 CFM @ 25Pa Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name Michael Hill Organization: TSI Energy Solutions Signature: Date: 2{11119 at 11:23 AM Ekotrope RATER - Version 3.1.0.2106 No version of this software has been reviewed or approved by ICC or its affiliates. The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC'). This software is a RESIN ETAccredited HERS Rating Tool. Energy Code Inspection Checklist Property Organization 3914 BEAR CREEK WAY TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Michael Hill OBF095 (AS DESIGNED) OVERBROOK FARMS 95 Builder FISCHER HOMES General Building Information Conditioned Area (sq ft) 5,278 Conditioned Volume (cubic ft) 46,778 Insulated Shell Area (sq ft) 9,672 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab [ Name: BSMT (2,277 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall [ Name: CONDIAMB (Exterior Perimeter [ft]: 168, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 E[ Name: CONDIGAR (Exterior Perimeter [ft]: 43, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Above Grade Wall El Name: CON DIAM B (1,742 s.f.) R-0.205 continuous insulation, R-15 cavity insulation Insulation Grade: I El Name: CONDIGAR (387 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property 3914 BEAR CREEK WAY CARMEL, IN 46074 OBF095 (AS DESIGNED) OVERBROOK FARMS 95 Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder FISCHER HOMES Name: CONDIATTIC (756 s.f.) R-0.205 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Joist El Name: CONDIAMB x;192 s.f.) R: 15.414 Name: CONDIGAR (43 s.f.) R: 15.414 El Name: CONDIATTIC (99 s.f.) R: 15.414 Roof Name: SECOND (2,277 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected E] Name: FRONT (71 s.f.), U: 0.310, SHGC: 0.26, Orientation: EAST El Name: BACK (142 s.f.), U:0.310, SHGC: 0.29, Orientation: WEST El Name: BACK GD (18 s.f.), U:0.310, SHGC: 0.29, Orientation: WEST El Name: RIGHT SIDE (27 s.f.), U:0.310, SHGC: 0.29, Orientation: NORTH C", Energy Solutions 2 Energy Code Inspection Checklist TSI Energy Solutions Property Organization 3914 BEAR CREEK WAY TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Inspection Status Michael Hill Results are projected OBF095 (AS DESIGNED) OVERBROOK FARMS 95 Builder FISCHER HOMES Name: LEFT SIDE (70 s.f.), U: 0.310, SHGC: 0.29, Orientation: SOUTH E] Name: RIGHT BSMT (20 s.f.), U:0.310, SHGC: 0.29, Orientation: NORTH El Name: LEFT BSMT (7 s.f.), U: 0.310, SHGC: 0.29, Orientation: SOUTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment 0 Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 92.1 AFUE Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 3,898 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. 3 Energy Code Inspection Checklist Property 3914 BEAR CREEK WAY CARMEL, IN 46074 OBF095 (AS DESIGNED) OVERBROOK FARMS 95 Duct Leakage Duct System 1 Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder FISCHER HOMES Inspection Status Results are projected NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 260.0 CFM @ 25 Pa Total Duct Leakage is specified in Ekotrope at 509.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary TSI Energy Solutions Property Organization 3914 BEAR CREEK WAY TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Michael Hill Inspection Status OBF095 [AS DESIGNED] Results are projected OVERBROOK FARMS 95 Builder FISCHER HOMES General Building Information Number Of Bedrooms 4 Number Of Floors 2 Conditioned Floor Area [sq. ft.] 5;278 Unconditioned, attached garage? Yes Conditioned Volume [cu. ft.] 46;778 Total Units in Building 1 Residence Type Single family detached Model EVERETT (AC) Community OVERBROOK FARMS 95 Climate Zone 5A Basement Wali Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, 4f[ 1 8 168 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, 4f[ 1 8 43 Exposed Exterior CDndttioned Space Basement Wall Library List Name Feet From Wall Tap To Insulation Feet From Wall Top To Insulation Is Fully Insulated R-value Top Bottom R-11 Draped, 4f[ 0 4 No 11.00 Sla Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area BSMT Uninsulated 211 Below Grade 0 a 2,277.0 sq. ft. Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Type Slab Complete l Underslab Insulation Perimeter Insulation Perimeter Insulation R R-value Insulated. Width [it] Depth [ft] Value Uninsulated Wood Frame / Other No 0 0 D 0.00 1 Building Summary Property Organization 3914 BEAR CREEK WAY TSI Energy Solutions CARMEL, IN 46074 317-846-4655 G1 R-15 BATT, T- PLY Michael Hill OBF095 [AS DESIGNED] Exposed Exterior OVERBROOK FARMS 95 Builder Medium FISCHER HOMES Framed Floor CONDIGAR G1 R-15 Gar Walls None Present 387.0 sq. ft. Unconditioned, attached garage Framed Floor Library List M None Present Rim Joist Name Library Type CONDIAMB G1 R-19, OSB CONDIATTIC G1 R-19, OSB CONDIGAR G1 R-19, OSB Rim Joist Library List Name R value G1 R-19, OSB 15.414 CTS, Energy Solutions Inspection Status Results are projected 1920.sq. ft. Exposed Exterior 99.0 sq. ft. Attic 43.0 sq. ft. Unconditioned, attached garage Name FM Library Type Surface Color Surface Area Location CONDIAMB G1 R-15 BATT, T- PLY Medium 1.742.0 sq. fl. Exposed Exterior CONDIATTIC G1 R-15 BATT, T- PLY Medium 756.0 sq. PI. Attic CONDIGAR G1 R-15 Gar Walls Medium 387.0 sq. ft. Unconditioned, attached garage 2 Building Summary Property 3914 BEAR CREEK WAY CARMEL, IN 46074 OBF095 [AS DESIGNED] OVERBROOK FARMS 95 Fall Library List Name G1 R-15 BATT, T -PLY G1 R-15 Gar Walls Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder FISCHER HOMES 12.842 11.972 Inspection Status Results are projected C-M, Energy Solutions Glazing Name Library Type Wall Assignment 9r Basement Wall Overhang Depth Assignment Overhang Ft To Top Overhang Ft To Bottom Orientation Surface Area BACK U-.31, SHGG29 CONDIAMB 0 0 0 West 142.0 sq. R. BACK GD U-.31, SHGG29 CONDIAMB 0 0 0 West 18.0 sq. ft FRONT U-.31, SHGG26 CONDIAMB 0 0 0 East 71.0 sq. & LEFT BSMT U-.31, SHGG29 CONDIAMB 0 0 0 South 7.0 sq. R. LEFT SIDE U-.31, SHGG29 CONDIAMB 0 0 ❑ South 70.0 sq. R RIGHT BSMT U-.31, SHGG29 CONDIAMB 0 0 ❑ North 20.0 s9. R RIGHT SIDE U-.31, SHGG29 CONDIAMB 0 0 ❑ North 27.0 sq. R Glazing Library List Name U-.31, SHGC-26 U-.31, SHGC-29 Shgc U fiaCtOr 026 0.310 029 0.310 9 Building Summary Property Organization 3914 BEAR CREEK WAY TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Michael Hill OBF095 [AS DESIGNED] OVERBROOK FARMS 95 Builder FISCHER HOMES rkylightbrary List None Present Opaque Door Name Library Type Wall Assignment Basement Wall Assign ment FRONT Steel Door CONDIAMB GARAGE Steel Door CONDIGAR Opaque Door Library List r Name U -facto r Steel Daar 0.182 Roof Insulation Name Library Type Attic Exterior Area Clay or concrete leant �-f.] Tiles SECOND R -3R Rlown C'R1 2 277 C-M, Energy Solutions Inspection Status Results are projected Solar Surface Color Surface Area Location Ab sorpta n ce 0.9 0.75 Medium 200 sq_ ft Exposed Exterior 0.9 0.75 Medium 18.0 sq_ ft Exposed Exterior Roof Insulation Library List Name Has R-38 Blown. GR1 Whale House InfiltrationMA Infiltration Me 5 ACH at 50 Pa Blower -door tested 4 n No Medium 2.277.0 sq. ft Attic No 38.268 4 Building Summary Property 3914 BEAR CREEK WAY CARMEL, IN 46074 OBF095 [AS DESIGNED] OVERBROOK FARMS 95 Mechanical Ventilation i Lighting A % Interior Fluorescent Lighting 1❑ Onsite Generation Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder FISCHER HOMES None Present Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present or Fluorescent Lighting Inspection Status Resuhs are projected C-M, Energy Solutions Lighting 0 0 ❑ A Building Summary Property Organization Equipment Type: ENT 50 100 3914 BEAR CREEK WAY TSI Energy Solutions Electric CARMEL, IN 46074 317-846-4655 Hot Water Efficiency 0.93 Energy Factor Michael Hill Inspection Status OBF095 [AS DESIGNED] 15.4 Results are projected OVERBROOK FARMS 95 Builder Fuel Type Natural Gas FISCHER HOMES Forced Air ing Equipment PSG (Single Speed) Heating Efficiency Name r Library Type Heating Percent Load C er [2] No EAE [kWh] GSX130481B 0% C-M, Energy Solutions g Percent Lead Hot Water 100% 0% Fuel-fred air GMSS920603BN 100% 0% 0% distribution [1] Water Heating [3] ENT 50 100 0% ❑ % 100% 1 Equipment Type: ENT 50 100 Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.98 Equipment Type: GMSS920603BN Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 92.1 AFUE Heating Capacity [kBtulh] 55 Use default EAE No EAE [kWh] 573 Equipment Type: GSX130481B Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 46 6 Building Summary Property 3914 BEAR CREEK WAY CARMEL, IN 46074 OBF095 [AS DESIGNED] OVERBROOK FARMS 95 stribution System Distribution Type Heating Equipment Cooling Equipment Sq. Feet Served 4 Return Grilles Supply Duct R Value Return Duct R Value Supply Duct Area [sq. ft.] Return Duct Area [sq. ft_] Duct Leakage to Outdoors (CFM25) Total Leakage Total Leakage Duct Test Conditions Use Default Flow Rate Duct 1 Duct Location Percent Supply Area Percent Return Area Duct 2 Duct Location Percent Supply Area Percent Return Area Duct 3 Duct Location Percent Supply Area Percent Return Area Duct 4 Duct Location Percent Supply Area Percent Return Area Duct 5 Duct Location Percent Supply Area Percent Return Area Duct 6 Duct Location Percent Supply Area Percent Return Area Ceiling Fan Has Ceiling Fan Cfm Per Watt F Water Distribution Organization TSI Energy Solutions 317-846-4655 Michael Hill Inspection Status Results are projected Builder FISCHER HOMES Forced Air Fuel -fired air distribution (1) Air conditioner (2) 5278 3 3❑ 30 1068.8 593.8 26❑ 5❑9 Post -Construction Yes Conditioned Space 7❑ 7❑ Attic (well vented; under insulation) 3❑ 30 Conditioned Space 0 Conditioned Space 0 Conditioned Space 0 Conditioned Space s No 144 Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 123 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length jft] 20 Drain Water Heat Recovery? No C-M, Energy Solutions Building Summary Property 3914 BEAR CREEK WAY CARMEL, IN 46074 OBF095 [AS DESIGNED] OVERBROOK FARMS 95 Clothes Dryer Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I mef Appliances and Controls Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder FISCHER HOMES Electric 2.62 Timer Controls 704 kWhlYear 0.081kWh $23.00 $0.581Therm 2.874 0.331 Programmable thermostat? Yes Dishwasher Size Standard Dishwasher Efficiency 270 kWh Range/Oven Fuel Electric Convection Oven? No Induction Range? No Refrigerator Consumption 709 kWhlYear Notes Inspection Status Results are projected C-M, Energy Solutions L1