HomeMy WebLinkAboutOBF-095 ENERGYIECC 2009 Performance Compliance
Property
3914 BEAR CREEK WAY
CARMEL, IN 46074
OBF095 (AS DESIGNED)
OVERBROOK FARMS 95
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
FISCHER HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
S1,650
S218
5411
$2,279
$1,303
$0
$3,582
Requirements
C4405.3
Performance-based compliance passes by 2.0%
402.4.12
Air Leakage Testing
C4402.5
Area -weighted average fenestration SHGG
402.5
Area -weighted average fenestration U -Factor
40322
Duct Testing
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052
Duct Insulation
C-M,
Energy Solutions
As Designed
$1,621
$200
$411
$2,233
$1,303
$0
$3,536
Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa.
Design exceeds requirements for IECC 2009 Performance compliance by 2%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Michael Hill
Organization: TSI Energy Solutions
Signature:
Date:
2111119 at 11:23 AM
Ekotrope RATER - Version 3.1.0.2106
IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool.
3914 BEAR CREEK WAY
CARMEL, IN 46074
FISCHER HOMES
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls R-11
Framed Floor NIA
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 5 ACH50
Window U -Value: 0.31, SHGC: 0.29
Building Features
Duct Supply R-30.0, Return R-30.0
Duct Leakage to Outside 260.0 CFM @ 25Pa
Total Duct Leakage 509.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name
Michael Hill
Organization: TSI Energy Solutions
Signature:
Date: 2{11119 at 11:23 AM
Ekotrope RATER - Version 3.1.0.2106
No version of this software has been reviewed or approved by ICC or its affiliates.
The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC').
This software is a RESIN ETAccredited HERS Rating Tool.
Energy Code Inspection Checklist
Property Organization
3914 BEAR CREEK WAY TSI Energy Solutions
CARMEL, IN 46074 317-846-4655
Michael Hill
OBF095 (AS DESIGNED)
OVERBROOK FARMS 95 Builder
FISCHER HOMES
General Building Information
Conditioned Area (sq ft) 5,278
Conditioned Volume (cubic ft) 46,778
Insulated Shell Area (sq ft) 9,672
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
[ Name: BSMT (2,277 s.f.)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
None Present
Foundation Wall
[ Name: CONDIAMB (Exterior Perimeter [ft]: 168, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
E[ Name: CONDIGAR (Exterior Perimeter [ft]: 43, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
Above Grade Wall
El Name: CON DIAM B (1,742 s.f.)
R-0.205 continuous insulation, R-15 cavity insulation
Insulation Grade: I
El Name: CONDIGAR (387 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property
3914 BEAR CREEK WAY
CARMEL, IN 46074
OBF095 (AS DESIGNED)
OVERBROOK FARMS 95
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
FISCHER HOMES
Name: CONDIATTIC (756 s.f.)
R-0.205 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Rim Joist
El Name: CONDIAMB x;192 s.f.)
R: 15.414
Name: CONDIGAR (43 s.f.)
R: 15.414
El Name: CONDIATTIC (99 s.f.)
R: 15.414
Roof
Name: SECOND (2,277 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
E] Name: FRONT (71 s.f.), U: 0.310, SHGC: 0.26, Orientation: EAST
El Name: BACK (142 s.f.), U:0.310, SHGC: 0.29, Orientation: WEST
El Name: BACK GD (18 s.f.), U:0.310, SHGC: 0.29, Orientation: WEST
El Name: RIGHT SIDE (27 s.f.), U:0.310, SHGC: 0.29, Orientation: NORTH
C",
Energy Solutions
2
Energy Code Inspection Checklist
TSI Energy Solutions
Property Organization
3914 BEAR CREEK WAY TSI Energy Solutions
CARMEL, IN 46074 317-846-4655 Inspection Status
Michael Hill Results are projected
OBF095 (AS DESIGNED)
OVERBROOK FARMS 95 Builder
FISCHER HOMES
Name: LEFT SIDE (70 s.f.), U: 0.310, SHGC: 0.29, Orientation: SOUTH
E] Name: RIGHT BSMT (20 s.f.), U:0.310, SHGC: 0.29, Orientation: NORTH
El Name: LEFT BSMT (7 s.f.), U: 0.310, SHGC: 0.29, Orientation: SOUTH
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
0 Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 92.1 AFUE
Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER
Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 3,898 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
3
Energy Code Inspection Checklist
Property
3914 BEAR CREEK WAY
CARMEL, IN 46074
OBF095 (AS DESIGNED)
OVERBROOK FARMS 95
Duct Leakage
Duct System 1
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
FISCHER HOMES
Inspection Status
Results are projected
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 260.0 CFM @ 25 Pa
Total Duct Leakage is specified in Ekotrope at 509.0 CFM @ 25Pa
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
TSI Energy Solutions
Property Organization
3914 BEAR CREEK WAY TSI Energy Solutions
CARMEL, IN 46074 317-846-4655
Michael Hill Inspection Status
OBF095 [AS DESIGNED] Results are projected
OVERBROOK FARMS 95 Builder
FISCHER HOMES
General Building Information
Number Of Bedrooms 4
Number Of Floors 2
Conditioned Floor Area [sq. ft.] 5;278
Unconditioned, attached garage? Yes
Conditioned Volume [cu. ft.] 46;778
Total Units in Building 1
Residence Type Single family detached
Model EVERETT (AC)
Community OVERBROOK FARMS 95
Climate Zone 5A
Basement Wali
Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing
CONDIAMB R-11 Draped, 4f[ 1 8 168 Exposed Exterior Conditioned Space
CONDIGAR R-11 Draped, 4f[ 1 8 43 Exposed Exterior CDndttioned Space
Basement Wall Library List
Name Feet From Wall Tap To Insulation Feet From Wall Top To Insulation Is Fully Insulated R-value
Top Bottom
R-11 Draped, 4f[ 0 4 No 11.00
Sla
Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing
Masonry Area
BSMT Uninsulated 211 Below Grade 0 a 2,277.0 sq. ft. Exposed Exterior Conditioned
Space
Slab Library List
Name Wall Construction Type Slab Complete l Underslab Insulation Perimeter Insulation Perimeter Insulation R R-value
Insulated. Width [it] Depth [ft] Value
Uninsulated Wood Frame / Other No 0 0 D 0.00
1
Building Summary
Property
Organization
3914 BEAR CREEK WAY
TSI Energy Solutions
CARMEL, IN 46074
317-846-4655
G1 R-15 BATT, T- PLY
Michael Hill
OBF095 [AS DESIGNED]
Exposed Exterior
OVERBROOK FARMS 95
Builder
Medium
FISCHER HOMES
Framed Floor
CONDIGAR
G1 R-15 Gar Walls
None Present
387.0 sq. ft.
Unconditioned, attached garage
Framed Floor Library List
M
None Present
Rim Joist
Name
Library Type
CONDIAMB
G1 R-19, OSB
CONDIATTIC
G1 R-19, OSB
CONDIGAR
G1 R-19, OSB
Rim Joist Library List
Name
R value
G1 R-19, OSB
15.414
CTS,
Energy Solutions
Inspection Status
Results are projected
1920.sq. ft. Exposed Exterior
99.0 sq. ft. Attic
43.0 sq. ft. Unconditioned, attached garage
Name
FM
Library Type
Surface Color
Surface Area
Location
CONDIAMB
G1 R-15 BATT, T- PLY
Medium
1.742.0 sq. fl.
Exposed Exterior
CONDIATTIC
G1 R-15 BATT, T- PLY
Medium
756.0 sq. PI.
Attic
CONDIGAR
G1 R-15 Gar Walls
Medium
387.0 sq. ft.
Unconditioned, attached garage
2
Building Summary
Property
3914 BEAR CREEK WAY
CARMEL, IN 46074
OBF095 [AS DESIGNED]
OVERBROOK FARMS 95
Fall Library List
Name
G1 R-15 BATT, T -PLY
G1 R-15 Gar Walls
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
FISCHER HOMES
12.842
11.972
Inspection Status
Results are projected
C-M,
Energy Solutions
Glazing
Name
Library Type Wall Assignment
9r
Basement Wall Overhang Depth
Assignment
Overhang Ft To
Top
Overhang Ft To
Bottom
Orientation
Surface Area
BACK
U-.31, SHGG29
CONDIAMB
0
0
0
West
142.0 sq. R.
BACK GD
U-.31, SHGG29
CONDIAMB
0
0
0
West
18.0 sq. ft
FRONT
U-.31, SHGG26
CONDIAMB
0
0
0
East
71.0 sq. &
LEFT BSMT
U-.31, SHGG29
CONDIAMB
0
0
0
South
7.0 sq. R.
LEFT SIDE
U-.31, SHGG29
CONDIAMB
0
0
❑
South
70.0 sq. R
RIGHT BSMT
U-.31, SHGG29
CONDIAMB
0
0
❑
North
20.0 s9. R
RIGHT SIDE
U-.31, SHGG29
CONDIAMB
0
0
❑
North
27.0 sq. R
Glazing Library List
Name
U-.31, SHGC-26
U-.31, SHGC-29
Shgc
U fiaCtOr
026 0.310
029 0.310
9
Building Summary
Property Organization
3914 BEAR CREEK WAY TSI Energy Solutions
CARMEL, IN 46074 317-846-4655
Michael Hill
OBF095 [AS DESIGNED]
OVERBROOK FARMS 95 Builder
FISCHER HOMES
rkylightbrary List
None Present
Opaque Door
Name Library Type Wall Assignment Basement Wall
Assign ment
FRONT Steel Door CONDIAMB
GARAGE Steel Door CONDIGAR
Opaque Door Library List r
Name U -facto r
Steel Daar 0.182
Roof Insulation
Name Library Type Attic Exterior Area Clay or concrete leant
�-f.] Tiles
SECOND R -3R Rlown C'R1 2 277
C-M,
Energy Solutions
Inspection Status
Results are projected
Solar Surface Color Surface Area Location
Ab sorpta n ce
0.9 0.75 Medium 200 sq_ ft Exposed Exterior
0.9 0.75 Medium 18.0 sq_ ft Exposed Exterior
Roof Insulation Library List
Name Has
R-38 Blown. GR1
Whale House InfiltrationMA
Infiltration Me
5 ACH at 50 Pa Blower -door tested 4
n
No Medium 2.277.0 sq. ft Attic
No 38.268
4
Building Summary
Property
3914 BEAR CREEK WAY
CARMEL, IN 46074
OBF095 [AS DESIGNED]
OVERBROOK FARMS 95
Mechanical Ventilation
i
Lighting A
% Interior Fluorescent
Lighting
1❑
Onsite Generation
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
FISCHER HOMES
None Present
Onsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
or Fluorescent
Lighting
Inspection Status
Resuhs are projected
C-M,
Energy Solutions
Lighting
0 0 ❑
A
Building Summary
Property
Organization
Equipment Type: ENT 50 100
3914 BEAR CREEK WAY
TSI Energy Solutions
Electric
CARMEL, IN 46074
317-846-4655
Hot Water Efficiency
0.93 Energy Factor
Michael Hill
Inspection Status
OBF095 [AS DESIGNED]
15.4
Results are projected
OVERBROOK FARMS 95
Builder
Fuel Type
Natural Gas
FISCHER HOMES
Forced Air
ing Equipment
PSG (Single Speed)
Heating Efficiency
Name
r
Library Type
Heating Percent Load C
er [2]
No
EAE [kWh]
GSX130481B
0%
C-M,
Energy Solutions
g Percent Lead Hot Water
100%
0%
Fuel-fred air GMSS920603BN 100% 0% 0%
distribution [1]
Water Heating [3] ENT 50 100 0% ❑ % 100%
1
Equipment Type: ENT 50 100
Fuel Type
Electric
Distribution Type
Hydronic Delivery
Hot Water Efficiency
0.93 Energy Factor
Tank Capacity (gal.)
50
Hot Water Capacity [kBtulh]
15.4
Recovery Efficiency
0.98
Equipment Type: GMSS920603BN
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
92.1 AFUE
Heating Capacity [kBtulh]
55
Use default EAE
No
EAE [kWh]
573
Equipment Type: GSX130481B
Fuel Type
Electric
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Cooling Efficiency
13 SEER
Cooling Capacity [kBtulh]
46
6
Building Summary
Property
3914 BEAR CREEK WAY
CARMEL, IN 46074
OBF095 [AS DESIGNED]
OVERBROOK FARMS 95
stribution System
Distribution Type
Heating Equipment
Cooling Equipment
Sq. Feet Served
4 Return Grilles
Supply Duct R Value
Return Duct R Value
Supply Duct Area [sq. ft.]
Return Duct Area [sq. ft_]
Duct Leakage to Outdoors (CFM25)
Total Leakage
Total Leakage Duct Test Conditions
Use Default Flow Rate
Duct 1
Duct Location
Percent Supply Area
Percent Return Area
Duct 2
Duct Location
Percent Supply Area
Percent Return Area
Duct 3
Duct Location
Percent Supply Area
Percent Return Area
Duct 4
Duct Location
Percent Supply Area
Percent Return Area
Duct 5
Duct Location
Percent Supply Area
Percent Return Area
Duct 6
Duct Location
Percent Supply Area
Percent Return Area
Ceiling Fan
Has Ceiling Fan
Cfm Per Watt
F
Water Distribution
Organization
TSI Energy Solutions
317-846-4655
Michael Hill Inspection Status
Results are projected
Builder
FISCHER HOMES
Forced Air
Fuel -fired air distribution (1)
Air conditioner (2)
5278
3
3❑
30
1068.8
593.8
26❑
5❑9
Post -Construction
Yes
Conditioned Space
7❑
7❑
Attic (well vented; under insulation)
3❑
30
Conditioned Space
0
Conditioned Space
0
Conditioned Space
0
Conditioned Space
s
No
144
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
123
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length jft]
20
Drain Water Heat Recovery?
No
C-M,
Energy Solutions
Building Summary
Property
3914 BEAR CREEK WAY
CARMEL, IN 46074
OBF095 [AS DESIGNED]
OVERBROOK FARMS 95
Clothes Dryer
Fuel Type
Cef
Field Utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I mef
Appliances and Controls
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
FISCHER HOMES
Electric
2.62
Timer Controls
704 kWhlYear
0.081kWh
$23.00
$0.581Therm
2.874
0.331
Programmable thermostat?
Yes
Dishwasher Size
Standard
Dishwasher Efficiency
270 kWh
Range/Oven Fuel
Electric
Convection Oven?
No
Induction Range?
No
Refrigerator Consumption
709 kWhlYear
Notes
Inspection Status
Results are projected
C-M,
Energy Solutions
L1