Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
15-H-501 Idexx
HVAC SYMBOLS LIST NOTE: ALL SYMBOLS NOT NECESSARILY USED GENERAL VALVES 2-WAY CONTROL VALVE cc W UNDERFLOOR PIPING OR DUCTWORK ------- O ----- - Q. 3-WACONTROLVALVE L�jJ EXISTING TO REMAIN (E) BALANCE/SHUT-0FF VALVE EXISTING TO BE REMOVED ------- (R)------- rr �VI EXISTING TO BE ABANDONED (AB) BALL VALVE BUTTERFLY VALVE CHECKVALVE PIPING EXPANSION VALVE ISOLATION VALVE - SEE PROJECT HEATING WATER SUPPLY HWS SPECIFICATIONS FOR REQUIREMENTS HEATING WATER RETURN HWR GATE VALVE DQ CHILLED WATER SUPPLY CWS GLOBE VALVE CA CHILLED WATER RETURN CWR PLUG VALVE CONDENSER WATER SUPPLY CS ¢0 CONDENSERWATER RETURN CR PRESSURE REDUCING VALVE G� LOW PRESSURE STEAM — LPS( #) — PRESSURE RELIEF VALVE LOW PRESSURE CONDENSATE — LPR(#) — HIGH PRESSURE STEAM —HPS(#)— SOLENOIDVALVE HIGH PRESSURE CONDENSATE — HPR(#) — MISCELLANEOUS CONDENSATE PUMP DISCHARGE CPD DUCTACCESS DOOR ®A.D. REFRIGERANT LIQUID L REFRIGERANT SUCTION S REFRIGERANT HOT GAS RIG FIRE DAMPER � COOLING COILCONDENSATE C VENT — — — — V — — — — SMOKE DAMPER HEAT PUMP WATER SUPPLY —HPWS— HEAT PUMP WATER RETURN —HPWR— SD COMB. FIRE/SMOKE DAMPER DUCTVOLUME DAMPER I cD SPECIALTIES 4 OT AUTOMATIC AIR VENT WITH MOTOR OPERATED DAMPER --�� BALL VALVE M MANUALAIRVENT DUCT CHANGE IN ELEVATION UP OR DOWN) CONCENTRIC INCREASER ►� FLEX DUCT C CONCENTRIC REDUCER ECCENTRIC INCREASER TURNING VANES ECCENTRIC REDUCER 1' SPIN -IN FITTING FILL FUNNEL FLEXIBLE CONNECTION ® FLOW ARROW DUCTSECTIONS I�L/VI fVYI IVV�i, RISE FLOW SWITCH 4 POSITIVE PRESSURE(SUPPLV/OUTSIDE) DROP f1 v I RISE GAUGE WITH BALL VALVE T NEGATIVE PRESSURE(RETURN/RELIEF) HEAT TRACED PIPE Al Al Al Al DROP METER ® RISE PIPEANCHOR NEGATIVE PRESSURE(EXHAUST)®�JJ®� CAP 1"� 1 I 7 DROP DROP D L,,II �0 ���::__✓✓✓ HUMIDISTAT OR HUMIDITY SENSOR RISE _p (MOUNT 48"A.F.F. U.N.O.) O PRESSURE/TEMPERATURE TEST PLUG Y THERMOSTAT OR SPACE TEMPERATURE O PIPE ALIGNMENT GUIDE SENSOR (MOUNT 480A.F.F. U.N.O.) FIRE RATED PIPE SLEEVE ----- SMOKE DETECTOR BY DIV. 26 SIGHTGLASS .�. DIV 23 TO PROVIDE DUCTACCESS O DOOR AT EACH OF THESE LOCATIONS STRAINER m DIFFUSER THERMOMETER 4� RETURN AIR DEVICE z THRUST BLOCK � STEAM TRAP TERMINAL BOXES, WITINVITHOUT REHEAT ® 0 UNION OR FLANGE CONNECTTO EXISTING V 4 VACUUM BREAKER DENOTES ITEM PROVIDED BY VALVE IN RISER/DROP iQ 4<0— ANOTHER CONTRACTOR, SHOWN FOR COORDINATION OR REFERENCE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camm�ed �VT�t�D*�41WML DATE: \ 03/15/19 SPLIT AIR CONDITIONING UNIT SCHEDULE DISCONNECT SWITCH UNLESS OTHERW ISE NOTED EQUIPMENT BASED ON MITSUI B ISH UNIT DATA COOLING CAPACITY CONDENSING UNIT DATA INDOOR UNIT ELECTRICAL DATA IrvDICAT® TOTAL SENSIBLE E.A.T. L.A.T. AMBIENT COMPIXJENTS PROVIDEDBY REMARKS TAG LOCATION MODEL ARRANGE. CFM MBH MBH DB"F DB"F REFRIG. OPERATION"F TAG LOCATION MODEL MOCP MCA VOLTS PHASE F.L.A. MCA VOLTS PHASE DIV23 I BN 6 CEILING INDOOR UNIT POWERED FROM OUTDOOR UNIT. ACi SEE PLANS PLA-A24AA MOUNT - 24.0 18.5 80 67 R410A 0 ACCU-AC7 SEE PLANS PLY-A24NH4 26 19 208 1 - - 208 1 Q - PROVIDE CONDENSATE PUMP. FAN COIL UNIT SCHEDULE UNLESS OTHERWISE NOTED EQUIPMENT BASED ON TRANE UNIT DATA FAN DATA FAN MOTOR DATA I COOLING COIL DATA ELECTRIC COIL DATA REMARKS TAG LOCATION MODEL TYPE MIN O.A. CFM CFM T.S.P. IN. W.G. RPM NO OF FANS HP RPM VOLTS PHASE TOTAL MBH SENSIBLE MBH E.A.T. OF LA.T. OF REFRIGERANT KW NO OF STAGES VOLTS PHASE D.B. W.B. D.B. W.B. SUCT"F TYPE FC7 SEE PLANS TE - 100 800 0.5 - - 0.5 - 120 1 35.0 25.6 80 67 59.9 57.5 - R410A 10.8 - 208 1 FC2 SEE PLANS TE - 300 1600 0.5 - - 0.75 - 120 1 47.1 34.8 80 87 59.5 57.4 - R410A 10.8 - 208 1 FAN SCHEDULE UNLESS OTHERWISE NOTED EQUIPMENT BASED ON GREENHECK KEY: CENT. -CENTRIFUGAL, PROP. -PROPELLER, F.C.-FORWARD CURVED, B.I.-BACKWARD, INCLINED, A.F.-AIRFOIL. UNIT DATA MOTOR DATA SOUND INDICATED RATING CDMPDNE 8 I>RDVIDEDBY REMARKS FAN WHEEL TIP SPEED T.S.P. TYPE TYPE TAPE TAG LOCATION MODEL FUNCTION TYPE TYPE FPM IN. W.G. CFM RPM OF CONTROL OF DRIVE OF DAMPER VV RPM VOLTS PHASE IN BONES DIV 23 DIV 26 EF1 SEE PLANS CSP-B150 GENERALEXHAUST CENT. F.C. - 0.75 100 947 SOLID STATE DIRECT BACKDRAFT 99 - 115 1 CODED NOTES: DISCONNECT VOLTAGE STARTERVARIABLE FREQUENCY DRIVE ©-WALL SWITCH ©=SWITCH CONTROL PANELWITH INTEGRAL DISCONNECT SWITCH D = LINE VOLTAGE PANEL RTERSH=EMERGENCY POWERK =THERMOSTAT F TWO SPEED STARTERS HEAT PUMP SCHEDULE UNLESS OTHERWISE NOTED EQUIPMENT BASED ON TRANE UNITDATA CONDENSER DATA ELECTRICAL DATA INDICATED DCNPONENIS PROVIDED BY REMARKS COOLING HEATING E.A.T. OF E.A.T. OF REFRIGERANT NO. OF TAG LOCATION MODEL CAP. (TONS) I CAP. MBH) SUMMER WINTER TYPE FANS MCA MOCP VOLTS PHASE DIV 23 DIV 26 HP-FC1 SEE PLANS 4TWR4 3 22.4 95 17 R41 OA 1 18 30 208 1 OA HP-FC2 SEE PLANS 4TWR4 4 30.0 95 17 R41 OA 1 26 45 208 1 (2 CODED NOTESDISCONNECT : (D - CONTROL PANEL (D - REDUCED VOLTAGE VARIABLE FREQUENCY DRIVE CONTROL PANELTCH ON ROL PANELWITH INTEGRAL DISCONNECT SWITCH D =LINE VOLTAGE PANEL F -TWO SPEED STARTERS H = EMERGENCY POWER ELECTRIC HUMIDIFIER SCHEDULE UNLESS OTHERWISE NOTED EQUIPMENT BASED ON NEPTRONIC HEAT DISP. UNIT/ CAPACITY BASIS FOR ABSORPTION ABSORPTION ENTERING ROOM SETPOINT ELECTRICAL DATA TAG LOCATION EXCH. UNIT DUCT LBSMR DISCFMCE DISTANCE DB TEMP./RH DB TEMP./RH REMARKS AMPS VOLTS PHASE MODEL MODEL SIZE 'F/% 'F/% PROVIDE CONDENSATE PUMP AND DRAIN HUH SEE PLAN SKE4-N06 SAM E2 - 18 1600 4'-0" - 70"130% 30.0 208 1 COOLER. TAG-NECKSIZE GRILLE, REGISTER & DIFFUSER SCHEDULE CFM UNLESS OTHERWISE NOTED EQUIPMENT BASED ON PRICE NECK SIZES ARE GIVEN ON DRAWINGS. TAG MODEL FUNCTION FACE FRAME LOUVERTYPE MATERIAL FINISH DAMPER N.C. MAX. REMARKS TYPE TYPE SQUARE COORDINATE FRAME TYPE WITH ARCHITECTS Di SPD SUPPLY SEE NOTES - STEEL WHITE NONE 30 REFLECTED CEILING PLAN. PLAQUE RETURN/ i X i X dZ COORDINATE FRAME TYPE WITH ARCHITECTS RI 80 SEE NOTES EGGCRATE ALUMINIUM WHITE NONE 30 REFLECTED CEILING PLAN. EXHAUST GRID GREEN Li HECK INTAKE - - LOUVERED ALUMINIUM BVARCHITECT NONE 30 ESD-403 ELECTRIC WALL HEATER SCHEDULE UNLESS OTHERW ISE NOTED EQUIPMENT BASED ON QMARK UNITDATA ELECTRIC DATA INDICATED REMARKS PRWIDED BY TAG LOCATION MODEL TYPE KW VOLTS PHASE DIV 23 DIV 26 EWH1 SEE PLANS AWH WALL 3 208 1 BO© RECESSED MOUNTED HEATER CODED NOTES: O = DISCONNECT SWITCH ® =THERMOSTAT © = INTEGRAL DISCONNECT SWITCH All SASTUI)IO s82 S. FRDNT sREET COLUMBUB, OHI043266:::] 614.824.1633 N C7 Q Z O � z O � z z Z W � aaaaaa� U U L.0 0 H = Z Qo aaa� L0 I'OO. CV T PRELIMINARY NOT FOR PONSTRUCTIOP 29 JAN 2019 OWNER REVIEW NOT FOR KORDA DRAWN WKNE I CHECKED:KNE )NSTRUCTION KDRQA NLMLrH ENGINEERING HVAC SCHEDULES & CONCEPTUAL DESIGN 1650 WATERMARK DRIV SYMBOLS LIST SUITE 200 SCHE AATICS COLUMBUS, OHIO 43215 DESIGN DEVELOPMEN WORKING DRAWINGS FOR REVIEW DRAwe !Z;Wce I H _ 5 0 J I Inenem DESIGNED BY: $ Wllmow CHECKED BY: Ed Kwww PWJECT NUMBER: ?nisi