HomeMy WebLinkAbout16-H-601 IdexxPROVIDE STAINLESS DUCTWORK T-O' UPSTREAM AND 5'-0 DOWNSTREAM DISPERSION TUBES OF DISPERSION TUBES. DUCT SLOPE DUCT TO (1) CENTRAL LOW POINT AND PROVIDE STRUCTURE TRAPPED DRAIN DISPERSION CEILING COUNTER FLASHING METAL DECK AND STRUCTURE MOUNT TO WALL ABOVE CEILING STEAM VAPOR HOSE (MAXIMUM 10') r STRAINER SLOPE / ISOLATION VALVE STEAM OR III L WTEREUP GENERAA '/." MIN. CONDENSATE PUMP) PREFERRED INSTALLATION DETAIL DETAIL PROVIDE STAINLESS DUCTWORK 1'-0' UPSTR EA%ND 64, DOWNSTREAM DISPERSION TUBES OF DISPERSION TUBES. DUCT SLOPE DUCTTO(1) CENTRAL STRUCTURE LOW POINT AND PROVIDE TRAPPED DRAIN % STEAM VAPOR HOSE `lIr.TWIIITH / (MAXIMUM 10.) SLOPE—� 6"MIN STEAM DISPERSION TUBES GENERATOR TRAPPED DRAIN /j / I T ROUTE TO DRAIN / "MIN.J 18"iIN. PER PER PLANS J CONDENSATE PUMP) OPTIONAL INSTALLATION INSTALLATION ONLY ALLOWED WHEN REQUIRED DUE TO INSUFFICIENT CLEARANCE ABOVE CEILING ELECTRIC DUCT MOUNTED HUMIDIFIER PIPING N.T.S. AIR COOLED CONDENSING UNIT ROOF RAILS: COORDINATE WITH ROOF PITCH ROOFING MATERIAL ■ VARIES SEE ARCHITECTURAL ROOF PLAN x 12" MIN. (REFER TO ROOF PLAN) ROOF RAILS - EQUIPMENT SUPPORT RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Canned AVT�t�D*�41WML DATE: \ 03/15/19 VIBRATION ISOLATOR (BOLTED DOWN) N.T.S. HANGER RODS PIPES INSULATION UNISTRUT DETAIL TYPICAL PIPE HANGER PROVIDE A SECTION OF HIGH COMPRESSION STRENGTH INSULATION AT EACH HANGER POINT. INSULATION MAY BE HALF ROUND OR FULL ROUND & EXTEND 2" BEYOND GALVANIZED SHIELD EACH WAY. GALVANIZED CARBON STEEL SHIELD N.T.S. ABOVE CEILING COOLING COIL DRAIN PAN STRAINER DRAIN LINE SAME SIZE AS NIPPLE ON DRAIN PAN ISOLATION VALVE CAPPED TEE FOR CLEANOUT � '/2" MAKEUP WATER ROUTE NEAREST DRAIN J 3/4" DETAIL COIL PRIME TRAP BEFORE UNIT START-UP A IN BIN DRAWTHRU COIL FANINLET STATIC CONDENSATION DRAIN TRAP PIPING MAIN DUCT (TYP.) AIR FLOW AIR FLOW AIR FLOW VOLUME DAMPER 3 (TYPT 3 1 Q BRANCH DUCT Q 0 (TYP.) LOW VELOCITY SUPPLY LOW VELOCITY SUPPLY LOW VELOCITY (CONICAL SPIN IN) RETURN/EXHAUST PROVIDE 18" LONG ORANGE MARKER TAPE ON EACH VOLUME DAMPER HANDLE TO IDENTIFY LOCATION SINGLE LINE DETAIL TYPICAL DUCT CONNECTIONS N.T.S. N.T.S. SECURE FLEXIBLE DUCTTO DUCT COLLARS WITH SCREWS & DRAWRANDS. PROVIDE ADDITIONAL DRAWBANDS AND SEAL FLEX OUTER JACKET TO DUCT COLLARS VOLUME DAMPER LOCATION WHERE DAMPER W OULD BE INACCESSIBLE AT TAKE -OFF, PROVIDE W / W EXTENDED SHAFT, HANDLE AND COLLAR TO S.A. INSULATED OPENING ROUND DUCT 18" LONG ORANGE MARKER TAPE ATTACHED TO DAMPER TO IDENTIFY LOCATION INSULATED NON-METALIC FLEXIBLE CONNECTION (MAX.3 FT.) DETAIL TYPICAL DIFFUSER MOUNTING 1D RADIUS MINIMUM, SHEET METAL ELBOW RECOMMENDED SUPPLY AIR DIFFUSER (LAY -IN FRAME) SLEEVE (4 SIDES) BACKER ROD & CAULK BIRD SCREEN SHEETMETAL PAINTED FLAT BLACK (OR OTHER COLOR AS DIRECTED BY CAULK ARCHITECT)BY Jill HVAC CONTI DOOR I�SLOPE BOTTOM OF PLENUM TO DRAIN N.T.S. EXTERIOR WALL (BRICK) 2" PLENUM INSULATION PROVIDE DRAIN LINE AND RUN TO NEAREST FLOOR GRAIN CAULK REFER TO ARCHITECTURAL DWGS. FOR DEPTH OF RECESS DETAIL LOUVER IN WALL W/BRICK N.T.S. WSASTUll 982 S. FRONT STREET COLUMBUS, OHIO 43206 fi14.824.1fi33 CV M QZ (.0 z O z 0 C c� z Z W U) aaaaaa� C/3 C) U W 0 H = Z Co aaa� LC� I� CV T PRELIMINARY NOT FOR CONSTRUCTIOI 29 JAN 2019 OMER REVIEW rq.exmcer NOT FOR {(ORDA DRAWN WKNEI CHECKETKNE )NSTRUCTION •KOREA NEMETH ENGINEERING HVAC DETAILS CONCEPTUAL DESIGN 1650 WATERMARK DRIVE SUITE 200 SCHEMATICS COLUMBUS, OHIO 43215 DESIGN DEVELOPMEN DR WN BY: C. Wnexeaa ^ O J DESIGNED BY: Sleplen Vinfli _ VM I WORKING DRAWINGS FOR REVIEW CHECKEDBY. E4 Kaenx PROJEDTNUMBER: 901A-N:iAS