HomeMy WebLinkAbout22-F-201 IdexxFIRE PROTECTION SYMBOLS LIST NOTE: ALL SYMBOLS NOT NECESSARILY USED GENERAL VALVES EXISTING TO REMAIN (E) ELECTRICALLY SUPERVISED VALVE EXISTING TO BE REMOVED -------- CHECKVALVE EXISTING TO BE ABANDONED AB) GATE VALVE GLOBE VALVE PRESSURE REDUCING VALVE PIPING WET PIPE ALARM VALVE FIRE MAIN F DRY PIPE ALARM VALVE COMB. FIRE B WATER SERVICE FW DELUGE VALVE ANTIFREEZE AF FIRE DEPARTMENT VALVE �a3 STANDPIPE SP INSPECTOR'S TEST CONNECTION :11— SPRINKLER PIPE SPR WALL INDICATOR VALVE DRAIN D FLOOR STAND VALVE — w COMB. SRINKLER B STANDPIPE S FLOW SWITCH DRY PIPE DP VALVE IN DROP DELUGE DL VALVE IN RISE SPECIALTIES SPRINKLER HEADS FIRE EXTINGUISHER ORE UPRIGHT Q FIRE EXTINGUISHER CABINET o REc PENDANT FIRE HOSE CABINET oRHc FLUSH/CONCEALED B FIRE HOSE/EXTINGUISHER CABINET oRHEc RECESSED FIRE HOSE RACK oRHa SIDEWALL FIRE VALVE CABINET oRvc NON -FREEZE PENDANT QDN WATER MOTOR GONG NON -FREEZE SIDEWALL '4N ELECTRIC ALARM BELL e EXTENDED THROW SIDEWALL �— GAUGE 0 SPRINKLER HEAD WITH DEFLECTOR WALL TYPE SIAMESE CONNECTION EXISTING SPRINKLER HEAD OE TEST CONNECTION TO REMAIN ROOF HYDRANT 0-0-0 EXISTING SPRINKLER HEAD OR UNION ­11 TO BE REMOVED SIGHT GLASS 8 MISCELLANEOUS FIRE RATED OR WATER TIGHT E� PIPE SLEEVE DETECTOR CHECK VALVE zr CONNECT TO EXISTING DETECTOR CHECK VALVE DENOTES ITEM PROVIDED BY WITH BYPASS METER IV ANOTHER CONTRACTOR, SHOWN lcc 4 FOR COORDINATION OR REFERENCE PRESSURE SWITCH STRAINER LOBBY too RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Camel ((�� �VTI�iID+nr)(1°AAL DATE: \\ 03/15/19 O ° CENTER IN TILE O ° CENTER IN 24 X 24 SECTION O 0 CENTER IN 24 X 24 OR 24 X 48 SECTION (D ° CENTER IN DIFF., LIGHT, PARTIAL TILE GRILLE. ETC. 0 O CENTER IN ONE 12 X 12 SECTION O6 CENTER IN THE GENERAL NOTE: NO. 2 TYPICAL FOR ANY STYLE OF CEILING TILE. GENERAL NOTES (APPLY TO ALL SHEETS) 1. SEE SKETCHES ABOVE FOR TYPICAL SPRINKLER HEAD LOCATION FOR VARIOUS CEILING TILE CONFIGURATIONS. COORDINATE WITH ARCHITECTURAL FINISH SCHEDULES AND DETAILS. 2. THE FIRE PROTECTION CONTRACTOR SHALL REFER TO THE REFLECTED CEILING PLAN FOR COORDINATION OF THE SPRINKLER LOCATIONS. / DETAIL ^/ SPRINKLER LOCATIONS IN VARIOUS CEILING N.T.S. TILE TYPES 1.0 2 20 GENERAL NOTES 1. THE SPRINKLER DRAWINGS ARE SCHEMATIC IN NATURE AND ARE INTENDED TO BE USED AS A GUIDELINE. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE EXACT NUMBER OF SPRINKLER HEADS AND EXACT PIPE SIZE BASED UPON THE HYDRAULIC CALCULATIONS TO MEET ALL GUIDELINES SET BYTHE OWNER'S REQUIREMENTS, BUILDING CODES AND THE AUTHORITY HAVING JURISDICTION. 2. AUTOMATIC SPRINKLER PROTECTION FOR ALLAREAS OF THIS CONTRACT WILL BE PROVIDED BYTHE FIRE PROTECTION CONTRACTOR. ALLAREAS ARE TO BE FULLY SPRINKLED. 3. PROVIDE DRAIN VALVES B PIPING TO ALLOW COMPLETE DRAINAGE OF ALL FIRE PROTECTION SYSTEMS. 4. THE CONTRACTOR SHALL COORDINATE THE WORK WITH THE ARCHITECTURAL REFLECTED CEILING PLANS, ROOM FINISH SCHEDULES, MECHANICAL DRAWINGS AND ELECTRICAL DRAWINGS. 6. PROVIDE SPRINKLER HEADS B PIPING THROUGHOUT THIS AREA AS PER NFPA 13, LIGHT HAZARD OCCUPANCY WITH A DENSITY OF 0.10 OVER THE MOST REMOTE 1,500 SF AND A MAXIMUM HEAD SPACING OF 226 SF/HEAD. STORAGE AND MECHANICAL ROOMS, JANITOR'S CLOSETS, ETC. SHALL BE ORDINARY HAZARD GROUP 1 OCCUPANCY WITH A DENSITY OF 0.16 GPM/SF OVER THE MOST REMOTE 1500 SF AND A MAXIMUM HEAD SPACING OF 130 SF/HEAD. 6. THE SYSTEM DESIGN IS BASED ON THE LATEST BUILDING CODE INCLUDING ALLAMENDMENTS THROUGH THE DATE OF DRAWING ISSUE. O CODED NOTES 1. EXISTING SPRINKLER HEADS AND BRANCH PIPING SHALL BE MODIFIED AS REQUIRED FOR THE NEW FLOOR PLAN. 2. EXISTING SPRINKLER SYSTEM TO REMAIN UNCHANGED UNLESS NOTED OTHERWISE. WSASTUI)IO 982 S. FRONT :REET COLUMBU6,OHI043206 614.824.1 BM N C7 Q z O � z C z H a 5 zz� W � U) U oCD EiiiiiiiiiiE o w Li 2 Z o0 � Ln ti N T UNISEX MtA �XEMIST HE AT00LOGY PRELIMINARY RES1p4O l 1OR NOT FOR �IBTY 1 ONSTRUCTIOP 103 OELIVMY/STORAGE CESSI G � 108 0 ❑❑ m AN, 29 JAN 2019OWNERREVIEW FLOOR PLAN LEVEL 1-NEW WORK SCALE: 1/8" = V-0" 0'1'2' 4' S' NOT FOR KORDA DRAWN BY RNE I CHECKEDXNE )NSTRUCTION KORDA NEMETH ENGINEERING LEVEL 1 FIRE CONCEPTUAL DESIGN 1650 WATERMARK DRIV PROTECTION PLANS SUITE :2CI SCHE AATICS COLUMBUS, OHIO 43215 DESIGN DEVELOPMEN WORKING DRAWINGS FOR REVIEW DBAw= C. Jea—waenem L I I F-2U1 DESIONeco : s'�epn�wnmon CHECKEDW Ea Kemx PIRC)JECTNUMBER: mi la-milas