Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
23-E-000 Idexx
1W$ASTtJD10 SYMBOLS LIST FOR PLANS 1. SOME SYMBOLS MAY NOT BE USED. 2. MOUNTING HEIGHTS ARE TO TOP U.N.O. SYMBOL DESCRIPTION LUMINAIRE: TYPE 'RI ';SEE LUMINAIRE SCHEDULE Re We W2 CEILING OR WALL MOUNTED LUMINAIRE TYPE (D;Q{:Cc 'R2','W2% SEE LUMINAIRE SCHEDULE EXIT SIGN FIXTURE (WITH DIRECTIONAL ARROWS AS �{ SHOWN) (TYPE AND MOUNTING AS NOTED; SEE —Xl x1 LUMINAIRE SCHEDULE) SHADED AREA DENOTES FACE I-0—I LUMINAIRE ON EMERGENCY LIFE SAFETY BRANCH ® 0 �LEMERGENCY LIGHTING BATTERY PACK W/INTEGRAL HEADS � : W TPF ANTI MOI INTNf: AR NOTFO REP I IIMMAIRF W1 C1 SCHEDULE) S SINGLE POLE SWITCH $2;3;4;K;P;T SPECIAL SW ITCH: 2-PCLE; 3-W AY; al -WAY; KEY OPERATED; SWITCH WITH PILOT LIG HT; TIMER SWITCH ® OCCU FANCY SENSOR, CE LI NG MOUNTED ®W OCCUPANCY SENSOR; WALL MOUNTED LINE VOLTAGE $M MOMENTARY CONTACT SWITCH Q VACANCY SENSOR, CEILING MOUNTED eS]W VACANCY SENSOR, WALL MOUNTED O DIMMER QD VS DIMMER/VACANCY SE NSOR, WALL MOUNTED POWER SYMBOLS 8 DUPLEX RECEPTACLE I& QUADRUPLEX(DOUBLE DUPLEX) RECEPTACLE llWP DUPLEX RECEPTACLE, WEATHERPROOF AND GROUND W/ FAULT INTERRUPTER GF ® DUPLEXRECEPTACLE, GROUND FAULT INTERRUPTER llx, �x LW RECEPTACLE MW- INDICATES OUTLET FOR MICROWAVE. ROUGH OUTLET IN CABINET ABOVE. VM- INDICATES OUTLET FOR VIDEO MONITOR FR- INDICATES OUTLET FOR REFRIGERATOR/FREEZER UC- INDICATES OUTLET UNDER COUNTER REFMG.FREEZER CM INDICATES OUTLET FOR COFFEE MAKER PR- INDICATES OUTLET FOR PRINTER C - INDICATES OUTLET FOR CLOCK CF- INDICATES RECEPTACLE FOR COPYIFAX MACHINE VD- INDICATES OUTLET FOR VENDING MACHINE M - INDICATES OUTLET FOR MONITOR TC - INDICATES OUTLET FOR TIME CLOCK TV - INDICATES OUTLET FOR TELEVISION ® B.33R SPECIAL PURPOSE RECEPTACLE (TYPE AS NOTED OR IN SPECIFICATIONS) �F DUPLEX RECEPTACLE, FLOOR MOUNTED O; OF JUNCTION BOX, CEILING OR WALL MOUNTED; FLOOR MOUNTED O MOTOR (BY DIVISION 1-25) MAGNETIC MOTOR STARTER (STARTER SIZE NO. OF ®3R POLES -AS NOTED)'3R' DENOTES NEVA'3R' ENCLOSURE S M MANUAL MOTOR STARTER SAFETY SWITCH (SWITCH SIZE, FUSE SIZE, NO. OF POLES Ep newest -AS NOTED)'3R' DENOTES NEMA'3R' ENCLOSURE, 3R NF 'NF' DENOTES NONFUSED COMBINATION MOTOR STARTER (STARTER SIZE, FUSE SIZE, v293 zH NO. OF POLES -AS NOTED)'3R' DENOTES NEVA'3R' 3R ENCLOSURE 0 PUSHBUTTON STATION ® CONTROL PANEL W—D I VARIABLE FREQU ENCY D FIVE VOICE/DATA TE RMINAL BOARD O POWERPOLE: INCLUDING 3 DUPLEX AND 4 DATA OUTLETS RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 03/15/19 MOUNTING HEIGHT UNLESS NOTED OTHERWISE SEE DRAWINGS 94' 94' COORD. HT 48" CEILING COORD. HT COORD. HT CEILING COORD. HT COOED. HT COOED. HT COORD. HT COORD. HT [HII:UlEII COOED. HT COOED. HT COORD. HT 48' COORD. HT COORD HEIGHT. 20- COOED HEIGHT. 20' COORD HEIGHT. COOED HEIGHT. 48' 60' SEE DRAWINGS SEE DRAWINGS W. 60' FRI 60' 48' SEE DRAWINGS SEE DRAWINGS M. SYMBOLS LIST FOR PLANS �1 P1 PANELBOARD: SURFACE MOUNTED, FLUSH MOUNTED PANEL DESIGNATION AS SHOWN 0 DISTRIBUTION PANELBOARD CONDUIT, RISER UP CONDUIT, RISER DOWN i--� CONDUIT ROUTED UNDERFLOORSPACE OR UNDERGROUND R FLEXIBLE METAL CONDUIT ORLIQUID-TIGHT FLEXIBLE METAL CONDUIT I[ TRANSFORMER: (TYPE AS NOTED ORIN TRANSFORMER Ti SCHEDULE) © MOTORIZED SHADE CONTROLLER PS POWERSUPPLY PP POWER PACK UNIT FIRE ALARM SYMBOLS O 0 CEILING MOUNTED FIRE ALARM SMOKE DETECTOR; HEATDETECTOR DUCT MOUNTED FIRE ALARM SMOKE DETECTOR ]2- ]2' SEE DRAWINGS COORD. HT 1 1 PORT, WALL MOUNT, (1) CATS LITE 20' v2 2 PORT, WALL MOUNT, (2) CATS UTP 20' v3 3 PORT, WALL MOUNT, (3) CATS LITE 20' v4 4 PONT, WALL MOUNT, (4) CATS UTP 20' �W TELEVISION OU'l(1) CATS LIFE, (1) R06 COAX 60' ® SECURITY SYSTEM GLASS BREAK DETECTION CEIL. OR M' 0 SECURITY SYSTEM MOTION DETECTOR CEIL OR 94' SYMBOLS LIST NOTES: 1. STRAIGHT LINES BETWEEN DEVICES INDICATE SWITCHED CIRCUIT. 2. STRAIGHT LINES BETWEEN DEVICES ON LIGHTING PLANS INDICATE SWITCHED CIRCUIT. ALL LIGHTING FIXTURES IN A ROOM OR CORRIDOR SHALL BE CONTROLLED VIA SWITCHES AND/OR OCCUPANCY SENSORS SHOWN UNLESS NOTED OTHERWISE. 3. SOLID SYMBOLS WITH SUBSCRIPT W INDICATE EXISTING DEVICES TO REMAIN. DASHED SYMBOLS WITH SUBSCRIPT'REL' INDICATE DEVICES TO BE RELOCATED. SOLID SYMBOLS WITH SUBSCRIPT'RD' INDICATE RELOCATED DEVICES. 4. DASHED SYMMS INDICATE EXISTING DEVICES TO BE REMOVED. DASHEDSYMBOLS WITH SUBSCRIPT'REL' INDICATE EXISTING DEVICES TO BE RELOCATED. ELECTRICAL ABBREVIATIONS ABBREVIATIONS USED ON DRAWINGS IN GENERAL ARE LISTED BELOW. REFER TO CSI DOCUMENT TD-24 FOR ANY ABBREVIATIONS LISTED ON THE DRAWINGS BUT ARE NOT LISTED BELOW. A AMPS AC AIR CONDITIONER ARE ABOVE FINISH FLOOR AEG ABOVE FINISH GRADE AHU AIR HANDLER UNIT BRKR BREAKER C CONDUIT CAW CABLE ANTENNA TELEVISION CCTV CLOSED CIRCUIT TELEVISION CUH CABINET UNIT HEATER CKT CIRCUIT CPT CONTROL POWER TRANSFORMER CPU CENTRAL PROCESSING UNIT Co COPPER DISTR DISTRIBUTION EF EXHAUSTFAN ELEC ELECTRICAL EM EMERGENCY EMT ELECTRICAL METALLIC TUBING EWC ELECTRIC WATER COOLER EX EXISTING EXP EXPLOSION PROOF TYPE DEVICE F FUSE FAA FIRE ALARM ANNUNCIATOR FAP FIRE ALARM PANEL FC FAN COIL UNIT FIXT LIGHT FIXTURE FLUOR FLUORESCENT FLR FLOOR FS FUSIBLE SWITCH G GROUND GRC GALVANIZED RIGID CONDUIT GF GROUND FAULT INTERRUPTING PROTECTION HID HIGH INTENSITY DISCHARGE HVAC HEATING, VENTILATION, AIR CONDITIONING HP HORSEPOWER J JUNCTION BOX KEC KITCHEN EQUIPMENT CONTRACTOR KV KILOVOLT KVA KILOVOLTAMPERE KW KILOWATTS LC LIGHTING CONTACTOR LV LOW VOLTAGE MCC MOTOR CONTROL CENTER MECH MECHANICAL MSS MAIN SWITCHBOARD MCC MOTOR CONTROL CENTER MTD MOUNTED ♦N INDICATES MOUNTING HEIGHT(N)TO BOTTOM OF DEVICE FROM FINISH FLOOR UNLESS OTHERWISE NOTED. NIC NOT IN CONTRACT NL NIGHTLIGHT NTS NOT TO SCALE OC OR O/C ON CENTER OH OVERHEAD P POLE (PHASE) PVC POLYVINYL CHLORIDE PE PNEUMATIC/ELECTRIC PNL PANEL I OR P PHASE RAF RETURN AIR FAN RTU ROOFTOP UNIT SW SWITCH TCP TEMPERATURE CONTROL PANEL TFMR TRANSFORMER TV TELEVISION TYP TYPICAL UG UNDERGROUND UH UNIT HEATER UNO UNLESS NOTED OTHERWISE V VOLTS VAV VARIABLE AIR VOLUME VFD VARIABLE FREQUENCY DRIVE VIE VERIFY IN FIELD VC VOLUME CONTROL W WATTS WP WEATHERPROOF TYPE DEVICE 1/E.1 MEANS DETAIL No. 1, DRAWING SHEET"Et" IT INFORMATION TECHNOLOGY BRANCH CIRCUIT GENERAL NOTE 1. BRANCH CIRCUIT CONDUIT ROUTING IS NOT SHOWN ON THE PLANS AND LEFT TO THE DISCRETION OF THE CONTRACTOR. BRANCH CIRCUIT WIRE SIZED SHALL BE AS FOLLOWS BASED ON CONDUIT ROUTE LENGTHS. BEFORE WIRING INSTALLATION, VERIFY THAT THE FURTHEST DISTANCE FROM PANELBOARD TO OUTLET DOES NOT EXCEED THE FOLLOWING DISTANCE FOR WIRE SIZE SHOWN. INCREASE W IRE SIZE APPROPRIATELY FOR FURTHER DISTANCES. CONDUCTOR SIZE I MAXIMUM LENGTH #12 AWG 100 FEET #10 AWG 150 FEET #8 AWG 250 FEET #6 AWG 400 FEET POWER GENERAL NOTES APPLIES TO EACH POWER DRAWING 1. REFER TO DRAWINGS AND SPECIFICATIONS OF OTHER CONSTRUCTION TRADES FOR ADDITIONAL ELECTRICAL WORK INCLUDED IN THIS CONTRACT. 2. COORDINATE EXACT LOCATIONS OF EQUIPMENT WITH OTHER CONSTRUCTION TRADES. VERIFY EXACT WIRING AND CONNECTION REQUIREMENTS WITH SUBMITTAL DOCUMENTS BEFORE INSTALLATION. SPECIALTY OUTLETTYPES SHALL BE VERIFIED BEFORE ORDERING. ALL ELECTRICAL WORK SHOWN HERE MUST BE VERIFIED AND COORDINATED IN FIELD BEFORE INSTALLATION. 3. REFER TO ARCHITECTURAL ELEVATIONS FOR OUTLET MOUNTING HEIGHTS. 4. EXACT LOCATIONS OF FLOOR RECESSED OUTLETS, SHALL BE COORDINATED WITH FURNITURE AND EQUIPMENT PLANS. OBTAIN LATEST PLANS FROM OWNERS REPRESENTATIVE. 5. ALL CONDUITS IN AREAS WITHOUT SUSPENDED CEILINGS SHALL BE RUN INCONSPICUOUSLY AS POSSIBLE, HIDDEN BEHIND BEAMS, CLOSE TO DECK, ETC. OBTAIN APPROVAL OF CONDUIT RUNS BELOW BEAMS WITH OWNER'S REPRESENTATIVE. 6. ALL DEVICES SHOWN ON THE EXTERIOR OF THE BUILDING SHALL BE WEATHERPROOF TYPE. T. REFER TO ARCHITECTURAL DOOR SCHEDULES, AND DOOR HARDWARE SPECIFICATION FOR ELECTRICAL DEVICES INSTALLED AT DOORS. 8. PROVIDE ALL FINAL POWER CONNECTIONS TO EQUIPMENT. PROVIDE ALL CONDUIT, DEVICE BOXES, AND CONTROL WIRING TO EQUIPMENT UNLESS NOTED OTHERWISE. 9. REFER TO ARCHITECTURAL PLANS FOR WALL CONSTRUCTION. 10. ALL RECEPTACLE FACEPLATES SHALL HAVE BRANCH CIRCUIT LABEL ON THE FRONT SIDE OF FACEPLATE. LIGHTING GENERAL NOTES APPLIES TO EACH LIGHTING DRAWING 1. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF LUMINAIRES. COORDINATE WITH OTHER TRADES CONTRACTORS, IN ADVANCE OF INSTALLATION, TO AVOID CONFLICTS OF SUFFICIENT SPACE ABOVE CEILINGS FOR RECESSED LIGHTING FIXTURES. 2. REFER TO ARCHITECTURAL ELEVATIONS, CASEWORK, AND DETAILS, ELECTRICAL DETAILS, AND LUMINAIRE SCHEDULE FOR LUMINAIRE MOUNTING HEIGHTS AND ADDITIONAL INSTALLATION INFORMATION. 3. LOCATIONS OF LUMINAIRES IN ROOMS W ITH MECHANICAL EQUIPMENT SHALL BE COORDINATED IN FIELD WITH INSTALLED EQUIPMENT. FIXTURES TO BE LOCATED OVER ACCESS PATHWAYS AROUND EQUIPMENT AND NOT OVER TOP OF EQUIPMENT OR DUCTWORK. DO NOT SUSPEND FIXTURES FROM PIPING OR DUCTWORK. PROVIDE APPROPRIATE MOUNTING HARDWARE AS REQUIRED TO SUPPORT FIXTURES. 4. SOME SWITCHED LIGHTING CIRCUITING NOT SHOWN FOR CLARITY. ALL FIXTURES W ITHIN A SPACE ARE TO BE CONTROLLED FROM SWITCHES/OCCUPANCY SENSORS SHOWN IN THAT SPACE UNLESS NOTED OTHERWISE. 5. REFER TO RELAY PANEL SCHEDULES FOR ZONED SWITCH CONTROL OF CIRCUITS CONTROLLED BY RELAY PANELS. 6. OCCUPANCY SENSOR POWER PACKS ARE NOT SHOWN FOR CLARITY REFER TO OCCUPANCY SENSOR WIRING DIAGRAMS. POWER PACKS TO BE LOCATED WITHIN EACH ROOM ABOVE CEILING ADJACENT TO ENTRY DOOR. PROVIDE CONDUIT AND W IRING FROM POWER PACK TO SENSOR UNITS. T. PROVIDE STEEL BRIDGING BETWEEN PURLINSIJOISTS/BEAMS AS NECESSARY TO SUPPORT THE WEIGHT OF SUSPENDED LUMINAIRES. 962 s. FRO STREET COLUMBUS, OHI043206 614.824.1633 V W '^aaaaa� �i O Q Q Z O 00 5W J °C cm W M C� U U C _O (d 00 L0 CV T PRELIMINARY NOT FOR ;ONSTRUCTIOI 28 JM 2019 D#MERREWEW NOT FOR KORDA DRAWNBY.MEI CHECIQD:KNE )NSTRUCTION KORDA NEMETH ENGINEERING ELECTRICAL SYMBOLS CONCEPTUAL DESIGN 1650 WATERMARK DRIVE SUITE 200 AND LEGENDS SCHEMATICS COLUMBUS, OHIO 43215 DESIGN DEVELOPMENT DRAWNSY Gyvaw. wawa Ruby D_000 CNEO DY: wua d. WORKING DRAWINGS DES FOR REVIEW cNECKEo av: c6acx« PROJECT NUMBER: 201 a_Q'385j