Loading...
HomeMy WebLinkAboutA102.CKEYED FLOOR PLAN NOTES (NOTED WITH (D ) RELEASED FOR CONSTRUCTION — — — — Subject to compliance with all regulations of State and Local Codes City of Cannel I �I ¢I I I I I I I I I I I I x I I I I I I I I I I I I ❑ x I I I I I I I I --1----------------------------------------- al x 0 0 x S. OPEN OFFICE 295 04 04 1 INSTALL EXISTING STOREFRONT, DOOR AND HARDWARE FROM AREA D - REF. DEMOLITION PLANS 2 AT EXISTING GYPSUM BOARD WALLS, PATCH/INFILL AND REPAIR AS REQUIRED FROM DEMOLITION. FIELD VERIFY FOR DESIGN INTENT. ALL ABANDONED OUTLETS AND FIRE EXTINGUISHER CABINET CAVITIES TO BE REPLACED BY DRYWALL FOR LIKE -NEW FINISH APPEARANCE 3 FIRE EXTINGUISHER. RE -USE SALVAGED FIRE EXTINGUISHERS FROM DEMOLITION PHASE 4 ALIGN NEW CONSTRUCTION CENTERED AND/OR FLUSH WITH EXISTING GEOMETRY. AT FLUSH CONDITIONS W/ DRYWALL, PATCH AND REPAIR AS REQUIRED FOR SEAMLESS TRANSITION 5 AT EXISTING GYPSUM BOARD COLUMN SURROUND, PATCH/INFILL AND REPAIR AS REQUIRED FROM DEMOLITION. FIELDVERIFYFOR DESIGN INTENT. ALL ABANDONED OUTLETS AND FIRE EXTINGUISHER CABINET CAVITIIES TO BE REPLACED BY DRYWALL FOR LIKE -NEW FINISH APPEARANCE 6 WHERE NEW WALL MEETS EXISTING WINDOW MULLION, PROVIDE (2) 2' X 2' CONTINUOUS 16 GA. CLEAR ANODIZED ALUMINUM ANGLES FROM SILL TO CEILING. 7 CASEWORK/COUNTERTOP- REFER TO A400 SHEETS 8 REPAIR EXISTING CONSTRUCTION WHERE INTERSECTING WALL WAS DEMOLISHED AT EXTERIOR WINDOW - REF. DETAIL 2/102.A 9 REINSTALL STOREFRONT, DOOR AND HARDWARE FROM ADJACENT LOBBYAREA. HARDWARE TO B ELECTRIFIED AND INSTALLED IN SAME MANNER AS EXISTING 10 REINSTALL EXISTING DOOR AT THIS LOCATION. REINSTALL HARDWARE AS APPLICABLE. IF NEW HARDWARE IS REQUIRED, REF. DOOR HARDWARE SPECIFICATION 11 BULKHEAD ABOVE- REF. REFLECTED CEILING PLANS 12 NEW DOOR OPENING IN EXISTING WALL, FIELD VERIFY AND COORDINATE WITH DOOR SCHEDULE 13 PROTECT EXISTING WINDOW, METAL WINDOW SILL, BULKHEAD AND WINDOW BLINDS DURING CONSTRUCTION. CAULK EXISTING METAL SILL PER DETAIL 2/A102.A. REPAIR EXISTING WINDOWSILLS AS NEEDED MW A I D N KEY PLAN _ 12. _ 1.-0. n OAMERICAN M■ STRUCTUREPOINT INC 7260 Slwpelanp ehtian I IMisnapolle, Indiana M256 TEL 317.M7.MM I MX317.393.0270 www.wmormmoim.nom GEICO CORPORATE SECOND FLOOR RENOVATION 101 W. 103RD ST. INDIANAPOLIS, IN 46290 oW No. AR10900003 CERTIFIED BY ISSUANCE INDEX DATE: 11/21/18 PROJECT PHASE: CONSTRUCTION DOCUMENTS REVISION SCHEDULE NO. DESCRIPTION DATE 1 PR013 01/31/2019 Project Number 2017.01381 SECOND FLOOR PLAN -AREA C DATE: 03/15/19 `a I< N 0 SECOND FLOOR PLAN -AREA C NOTES: 1. REFER T01B" SCALE SHEETS FOR PLAR KEYNOTES. 2. AREAS SHOWN IN GRAY ARE EXISTING TO REMAIN. A102.0