HomeMy WebLinkAboutA702.AFINISH MATERIAL KEY
GENERAL FINISH NOTES
2
IL
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Cannel
A\"
FLOORS
CPT-1 MANUFACTURER: SHAW
STYLE: TEMPT TILE
NUMBER ST019
COLOR ENTICE 18M5
INSTALLATION: QUARTER TURN
LV.l MANUFACTURER: TANDUSCENTIVA
STYLE: VENUE ABSTRACT NUVA
SIZE'6"X36"
NUMBER 51M
COLOR: ANTHRACITE
INSTALLATION: RUNNING BOND
T-1 MANUFACTURER: LOUISVILLE TILE
STYLE: ATLAS CONCORDE, MEK
SIZE: 12'X24"
COLOR: BRONZE
INSTALLATION: HORIZONTAL RUNNING BOND
GROUT:
CONTACT TRACEY KESSENS
(TK=SSENS@LOUISVILLE-TILE COM)
WALLS
PT-1 MANUFACTURER SHERWIN WILLIAMS
NUMBER: SW6147
COLOR PANDA WHITE
PT-2 MANUFACTURER: SHERWIN WILLIAMS
NUMBER: SW6711
COLOR PARAKEET
PT-3 MANUFACTURER SHERWIN WILLIAMS
COLOR TO MATCH T-1
PT-4 MANUFACTURER SHERWIN WILLIAMS
NUMBER: SW0D48
COLOR: BUGLEHOUSE BLUE
MILLWORK
PL-1 MANUFACTURER: WILSONART
STYLE: STH AVE. ELM
NUMBER: 7%6K-12
T-2 MANUFACTURER: MATCH TO EXIST. WHITE AM SS-1
WALL TILE IN RESTROOM, NO ACCENT BAND
EP-1 MANUFACTURER:SHERWINWILLIAMS
STYLE: CERAMIC CARPET;900
COLOR: CHARCOAL
SPA SEALED CONCRETE
VCT-1 MANUFACTURER: ARMSTRONG
STYLE'EXCELON
COLOR: CHARCOAL 51915
BASE
VB-1 MANUFACTURER: JOHNSONITE
STYLE: 4" COVE
NUMBER 63
COLOR: BURNT UMBER
TBA MANUFACTURER: LOUISVILLETILE
STYLE: ATLAS CONCORDE, MEK
SIZE: ITX24"
COLOR: BRONZE
TB-2 MATCH TO EXIST. WHITE TILE
(T-2) IN RESTROOM
EP-1 MANUFACTURER: SHERWIN WILLIAMS
STYLE: 6" CERAMIC CARPET INTREGAL BASE
COLOR: CHARCOAL
MANUFACTURER: DUPONT
STYLE: WILSONART
NUMBER 9077ST
COLOR MILK GLASS SPECTRA
DOORS
MANUFACTURER MARSHFIELD
STYLE. SOLID CORE
SOLID MAPLE, FLAT CUT
COLOR BOMBAY64ffi
i10l01ITAMA19
A. ALL GENERAL FINISHES ARE NOTED ON FINISH ROOM TAG U.N.O. AND FINISH MATERIAL
LEGEND FOR MORE INFORMATION.
B. REFERENCE REFLECTED CEILING PLAN FOR ADDRIONAL CEILING INFO.
C. ALL NEW INTERIOR FINISHES, INCLUDING FLOOR, WALL, AND CEILING MATERIALS,
SHALL BE IN ACCORDANCE WITH FLAME SPREAD AND SMOKE DEVELOPMENT
REQUIREMENTS FOUND IN THE CURRENT EDITION OF THE INTERNATIONAL BUILDING
CODE.
D. CONTRACTOR TO SUBMIT A MINIMUM OF THREE SAMPLES OF EACH FINISH TO
DESIGNER FOR APPROVAL PRIORTO ORDERING. ALTERNATES WILL NOT BE
ACCEPTED W ITHOUT WRITTEN APPROVAL OF ARCHITECT.
E. CONTRACTOR TO IMMEDIATELY NOTIFY ARCHITECT IF A SPECIFIED FINISH REM
BECOMES UNAVAILABLE.
F THE CONTRACTOR SHALL BE RESPONSIBLETOVERIFYTHAT ALL NEW INTERIORWALL
AND CEILING FINISHES WILL BE CLASS B MINIMUM, WITH A FLAME SPREAD RATING OF
75 MAXIMUM AND A SMOKE DEVELOPED INDEX OF 450 MAXIMUM PER IBC SECT]ON 803
G. PREPARE ALL FLOOR AND WALL CONSTRUCTION, NEW ANDIOR EXISTING, TO RECEIVE
NEW FINISHES IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDED
INSTALLATION METHODS AND MATERIALS FOR ALL FINISHES.
H. PRIOR TO INSTALLATION OF NEW FINISHES, CONTRACTOR SHALL INSPECT ALL
SUBSTRATES. IF A SUBSTRATE IS DEEMED UNACCEPTABLE, THE CONTRACTOR SHALL
TAKE THE NECESSARY STEPS TO RECTIFY THE SITUATION OR CONTACT THE
ARCHITECT WITH THE CONCERN. PROCEEDING WITH THE INSTALLATION OF FINISHES
WILL BE INDICATION THAT THE INSTALLER I FINISHER ACCEPTS CONDITION OF
SUBSTRATE
I. USE MANUFACTURER'S RECOMMENDED INSTALLATION METHODS AND MATERIALS FOR
ALL FINISHES.
J. ALL NECESSARYTILE FLOORING UNDERLAYMENT TO BE PROVIDED AND INSTALLED BY
FLOORING CONTRACTOR
K. FLOORING CONTRACTORTO LEVEL SUBSTRATE AS REQUIRED TO ACCEPT NEW
FLOORING MATERIAL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION.
FOR CARPET REQUIRING SEAMING, PROVIDE SEAM DIAGRAM LAYOUT FOR DESIGNER
APPROVAL PRIOR TO INSTALLATION.
L CARPET SEAMS TO BE LOCATED AT CENTERLINE OF DOOR WHEN DOOR IS IN CLOSED
POSITION
M. ALL FLOORING TRANSITIONS SHALL COMPLY WITH ADA GUIDELINES. FLOORING
CONTRACTOR TO SUBMIT A DIAGRAM SHOWING FLOORING TRANSITION LOCATIONS
FOR DESIGNERS APPROVAL PRIOR TO INSTALLATI ON.
N. ALL TRANSITIONIREDUCER STRIPS AND OTHER THRESHOLDS TO BE LOCATED AT
CENTERLINE OF DOOR WHEN IN CLOSED POSITION
0, ALIGN FLOORING TRANSITIONS WITH FINISH BASE EXCEPT AT DOORS, U.N.O.
P. FLOOR FINISHES ARE TO EXTEND UNDER NEW BUILT-IN CABINETS.
Q. FINISH LEVEL OF GYP BD. WALLS AND SOFFITS TO BE LEVEL 4, U.N.O.
R ALL PAINTED WALLS TO BE PAINTED PT-1, UNLESS NOTED OTHERWISE.
S. ALL GYP. BOARD CEILINGS TO BE PAINTED PT-1, UN.O,
T. ALL PAINTED SURFACES SHALL RECEIVE A MINIMUM OF (1) ONE BASE COAT AND (2)
TWO FINISH COATS
U. PAINTED SHEEN LEVEL TO BE SATINIEGG-SHELL FOR ALL WALLS, U.N.O. SHEEN FOR
ALL WET AREA WALLS, METAL DOORS AND METAL FRAMES TO BE SEMI -GLOSS.
V. ALL WET AREA WALLS TO BE PAINTED WITH EPDXY PAINT.
W. PAINT ALL EXPOSED METAL SURFACES, SUCH AS GRILLES, FIRE EXTINGUISHER
CABINETS, ETC. WITH PAINT TO MATCH ADJACENT SURFACE.
X. ALL METAL DOORS AND FRAMES TO BE PAINTED TO MATCH ADJACENT SURFACE
Y. PROVIDE METAL SCHLUTER TRANSITIONS AT ALL OUTSIDE CORNERS AND EXPOSED
TILE EDGES, INCLUDING TILE BASE (TBA)
I
1 I A702 B 11/ A702.0
-
----------------------------------------------------------------------------------------------------------r---
❑ o
❑ o a
VD FLOOR FINISH PLAN
B C
A D
KEY PLAN
12' = 1'-O^
NOTES:
1. REFERT0IB"SCALESHEETSFORPLANKEYNOTES.
2. AREAS SHOWN IN GRAY ARE EXISTING TO REMAIN.
n
OAMERICAN
M■ STRUCTUREPOINT
INC
III
7260 sMpnlana ehtian I IMianapolle, Indiana M256
TEL 317.547.5580 1 FAX317.393.0270
www.mu rurepoim.mm
GEICO CORPORATE
SECOND FLOOR
RENOVATION
101 W. 103RD ST.
INDIANAPOLIS, IN 46290
No.
AR10900003
CERTIFIED BY
ISSUANCEINDEX
DATE:
11/21/18
PROJECT PHASE:
CONSTRUCTION DOCUMENTS
REVISION SCHEDULE
NO. DESCRIPTION DATE
1 PRO13 01/31/2019
Project Number 2017.01381
SECOND FLOOR
FINISH PLAN -AREA A
A702.A
DATE: 03/15/19