HomeMy WebLinkAboutM302.AeA A. eB B. eC eD eE eF eG
I I I I I I I I I
Cd I 14my-.j
14x10
too
RG 3 SD-1 U-10.2-32— — —
8/190 SD1 C
® SO en90 1
® TU-10-z-3z
II N.OPEOFICE n � iOm—
I m
2
01 Idi 61i
NC
10x10 16x12
4x10
RG-E RG-E SD-1 m
N
I 8/190 II I u Bm NC —�NC
A N _ sD-1
I I I SD-1 8%190 ®16k8
IBX16 2x18 40x30 50x30
NC
0TU--2-10 1 14x10 y tom
- - - - - TU728 CT I k
-7-2-7= r - TTII $
r - L - UJf 20X12
4i 02O NC
m
2 ddx20 52x24 NC
Kyy 32X20 m
RG-1 20x12/115 12x6 �RG-E d d
N NC 14x - - p RG-3
20X10 20x10 MMEI5 _ 8290
EG-E /
6x16 20x12/3 _ SD-1
8220 14x10
12m IF
u
24x16
SDA
8235
el
I
LJ
x12 - 20
RG-3
16XB
24x16 20X16
® SD-1 s i
8/235
.. 8235
a
Qtr
RON II ACE.
UNITT
S
6X8 MMENE
GENERALNOTES:
A. ALLEQUIPMENTAND DUCTWORKSHOWN
WITH THIN/LIGHT SOLID LINES IS EXISTING TO
REMAIN.
B. ALLEQUIPMENTAND DUCTWORKSHOWN
WITH THICK/DARK SOLID LINES IS NEW OR
RELOCATED.
C. RELEVANT EQUIPMENT AND DUCTWORK
SHOWN IS BASED ON EXISTING DRAWINGS
AND FIELD SURVEY. NOT ALL EXISTING
EQUIPMENT AND DUCTWORK IS SHOWN.
CONTRACTOR SHALL FIELD VERIFY ALL
CONDITIONS AFFECTED BY THIS RENOVATION
AND NOTIFY THE ENGINEER IF CONDITIONS
ARE NOTAS INDICATED.
D. BRANCH DUCTWORK RUNOUTS TO DIFFUSERS
AND TERMINAL BOXES SHALL MATCH THE
INLET SIZES OF THE DIFFUSERS AND
TERMINAL BOXES, UNLESS OTHERWISE
NOTED.
E. REMOVE AND RE -INSTALL EXISTING LAY -IN
CEILING AS REQUIRED TO COMPLETE WORK.
REPLACE DAMAGED CEILING MATERIALS TO
MATCH EXISTING CEILING.
F. REMOVE EXISTING DRYWALL CEILINGS AS
REQUIRED TO COMPLETE WORK. PATCH AND
PAINT CEILINGS TO MATCH EXISTING
CONDITIONS.
G. REMOVE EXISTING DRYWALUMASONRY WALLS
AS REQUIRED TO COMPLETE WORK. PATCH
AND PAINT WALLS TO MATCH EXISTING
CONDITIONS.
H. REFER TO ARCHITECTS REFLECTED CEILING
PLAN FOR FINAL LOCATIONS OF AIR OUTLETS
AND INLETS. ADJUST BRANCH DUCTWORK AS
REQUIRED.
TU-3-2-8 � kd 1 L J 1 / -3-2-]
)ia - NL O- - e6
MYlMEM
232 SD-1 SD-1
%� 10/305 101305
co
OAMERICAN
No STRUCTUREPOINT
7260 Saedeland Station I Indianapolis, Indiana 48056
TEL 317.541.55801 Fax 317.543.000
wwn.mmnMrepeim.n°m
8900 KEYSTONE XING PH: 317.848.5045
SUITE 210 FAX 317.844.2201
INDIANAPOLIS, IN www.imegeorp.com
46240
V° too I I 16xe NCJ O I r ,I (�I (�I (�I (�I (�I (� I V U_LaJ 0._. ' 12x171225
12x12 NC yl I NOPEry OE`.ICE
16x12 201 NC
lbi�U-3-2-8
20x1
2m
RG-3 14m
IT, 0m _ NC NC
SD-1 NC I� 1 ,tom tom 1 GEICO CORPORATE
8235 SD -I — SECOND FLOOR
SDA
MENS
PSI 8235 823 ®I 6x6 I RENOVATION
w l _ 22 iy IY 2N12
sD-1 ONFEF WE
12/515 ®® ®�� TOxTO
1\
L
pYP OP6CE SDI BOA
NC 120 14x6 MENS D 1 81165 6/150
p m
8/165
SDA
12/515 20x12/3E0
"O 14x10 TU-7 RG2 tOx10 Plan MCN. RG-2
I I
I I I I I I I
core.
2m
— - — T — — — — — — — - — — — - — — — — — — — T — — —
I I I I I I I 1
--- - 22x12 il.li Ja 17ai Sa 6D-1-1 SD-1
--- 10fJ30 S.OPEN OFFICE 10/330
10m 20x14 NC NC 235 RG
10x12 3 101 W. 103RD ST.
10x6 RG 3 10x6 i6xi6 NC INDIANAPOLIS,
"--
— — — — — — — — — — — INDIANAPOLIS, IN 46290
16x8 !—I
NC 24x16 A IIIIIIID
SD-1 TU-3-2-9
— — — — — N329 —
IL 8200 10m SD-1
10e 10/330
I{JpI� sD-1 SD-1
NC �10/345 100 10/330 � � `*•
8200 N. OPEN omcE SD-1 1 NC 10m NC f
�1 10/345 1�
Bm 12x12 24x16
T - -2-1
Jj1 NC 76x8 NC NC
24x16 20x14 NC 10m 10m
10m 10m _ C
II u az-a I 16ke NC I� Sp_1 �I IIII® I ®I 1
L — J 8m SD-1 Be fl/200 SO/350 90/350 OI330 BDt
NC fl/200 — � 10/330 — —
I I I 4
22x12 i�� 20x14I1RG-3 1 1
ex
~
NC 12x12
TU-8-2-
N 13 C RG-1
U-8-2-11
TU-8-2-17
sD-t
Iq� sD-t
NC 100
iN3I�5p0yiN350
SD-1 IX. EL.
SD-1 ®
—
-I-2-� 1 `..1om
8250
L ,
8200 E2
r�
40m
LOEBV
TU-8-2-10
NC
4
NC 6
N. OPEN OFFCE So E= 12x10 N L 120 - - - - -
a
— _ CERTIFIED BY
El IX. EL. 1 `, 160
SD-1 — + — — — — - — — Q
— I — I — —1 — 1 — — — — I — — — I — — — —1 — — — I — — — — — — — 1 — — 20A — — — I — — — 2
ISSUANCE INDEX
DATE:
11/21/18
PROJECT PHASE:
CONSTRUCTION DOCUMENTS
tom
10m
SD-1 SD-1
I I I I I I I I I io/3so II® io/aso I I
s. oPov oFFlcE
— — — — — — — — — — — — — — — — — — -- — — — — — — — — — — —
II vxs
I I I I I I I I I I I I I
I I I I I I I I I I I I I
I
I I I I I I I I I I I I
I I I I I I I I I I
I I I I I I I I
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
at State and Local Codes
City of Caramel
DATE: 03/15/19
' Project Number 18002480.00
aldd laYGTONExMG, mmnE„° SECOND FLOOR
Paa. INJ@Ip
�IME ;nuAnspasFwxanaaSaeM
"""'"gaxaspi PROECTO 1®]6600 MECHANICAL PLAN —
AND CCRP IiESERYES PROPRIETARY RMMS.INCILpNG CCVYMGMS. TO THIS AREA A
DRAWING AND THE DATA SHOWN THEREON. 541G GPAW ING PNO/CR MTA PAE
IXE IX0.USNE PRWERIY C£ MFG NIiPPNU SXPl1 NOT BE USEOOR
H FPRW UCEU FOR ONYOTIFA PRQIFGT W RXOIR TXE EXPRESS WRRTFN
PPRIOVPL PNn PA0.TCPATpN G£IMEG LONP. 6201811MEG Cg1P.
REFERENCE SCALE IM INCHES S M 3 0 2 . A