HomeMy WebLinkAboutP301.AKEYNOTES:
1. 2-112" COLD WATER DROP.
2. 1" HOT AND COLD WATER DROP, 2" VENT RISE,
2" WASTE DROP.
3. 3/4" HOT AND COLD WATER DROP.
4. CAP BRANCH PIPE ABOVE CEILING.
5. 4" VENT DROP.
6. 3/4" HOT WATER DROP.
'A A. e6 B. eC eD eE eF eG eH el eJ eK
ORRg0R
G5
STOP
TR4sNMTRsN TRANIANO
�TNNI COI COrvE1EFlE CE
iiR ING 150 lu TEARING TEARING
IE 11/2"CW
1/2"CA Ili lil
GENERAL NOTES:
A. ALL EQUIPMENT AND PIPING SHOWN WITH THIN/LIGHT SOLID LINES IS EXISTING TO
REMAIN.
B. ALL EQUIPMENT AND PIPING SHOWN WITH THICK/DARK SOLID LINES IS NEW OR
RELOCATED.
C. RELEVANT EQUIPMENT AND PIPING SHOWN IS BASED ON EXISTING DRAWINGS AND
FIELD SURVEY. NOT ALL EXISTING EQUIPMENT AND PIPING IS SHOWN. CONTRACTOR
SHALL FIELD VERIFY ALL CONDITIONS AFFECTED BY THIS RENOVATION AND NOTIFY THE
ENGINEER IF CONDITIONS ARE NOT AS INDICATED.
D. DOMESTIC WATER BRANCH PIPING RUN OUTS TO PLUMBING FIXTURES SHALL BE 314.
DIAMETER, UNLESS OTHERWISE NOTED.
E. REMOVE AND RE -INSTALL EXISTING LAY -IN CEILING AS REQUIRED TO COMPLETE
WORK. REPLACE DAMAGED CEILING MATERIALS TO MATCH EXISTING CEILING.
F. REMOVE EXISTING DRYWALL CEILINGS AS REQUIRED TO COMPLETE WORK. PATCH
AND PAINT CEILINGS TO MATCH EXISTING CONDITIONS.
G. REMOVE EXISTING DRYWALUMASONRY WALLS AS REQUIRED TO COMPLETE WORK.
PATCH AND PAINT WALLS TO MATCH EXISTING CONDITIONS.
I of 1
H. THE FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR THE DESIGN,
COORDINATION, AND INSTALLATION OF THE FIRE PROTECTION SYSTEM, INCLUDING
REMOVING AND INSTALLING NEW PIPING AS REQUIRED FOR A COORDINATED
INSTALLATION. THE FIRE PROTECTION SYSTEM IS TO BE DESIGNED AND INSTALLED IN
COMPLIANCE WITH NFPA AND ALL OTHER STATE AND LOCAL CODES.
4 I'I
n cA — — — ——1/2'ca , 1/2"SAN — — — -
-
N 2 L-2
N Ii j l 196 CO H L
I I I I f I I I I I I I I � C 1 1 `� 1� I sH ER y ,5 w o
9/
WC7 3
3 CORRIDOR 3/4" WC-1 WC-1 WC-1 C-2 WC-2
Q CORRIDOR U
2
4 C4 U 4 Ii i EWC-1 SH-1 METHE E0JWE
o 0 05 6 -1 1 C o
1/2"C 1 N SH-1 CO
4•
3 SH-
R-1 UR-1 UR-2 ,F iCORRIDOR
FILE SIORPGE ICE OFF
ICE WC-
N 3 WC-1 C-1 C-2 • F " Gil
n7 FFl B i 1/2"CAFRI
-
1m 1 1 119 1 1151 1 M 1 sH AR
1/2"CA 3 ," DAS WER
-- -3N- --r 3"V— i-3W 2"V NEW MENS ' 2N- 1 112Vw,f u
I NL
TRAINING lk
7FN vz^cA z 112"Cw L-z L-z L-z L-z %
o 10 > 14 MB-1 1 1/4"HW 1czA
❑ ❑ SI 4
MERGERLL
I', H 1� y rA II
12
LV f Cz __— NC — — — — — a — — — — — — -
---PPoM
34"cW e5
--------------------
1/2"CW 1/2"CA
MINT
u, n�a
1/2"CAHPoNil ECFUIRNG — — — — —— =PLESiOR. [N S E — — — —IXISLWOMENG 110 IG3 1 2"CA 121 / CORRIDORC4 1 1/4"V- Q CONFERENCELF�
Io ®®® n3N ioEws10RA . 1 �> EwsT 1A 1mnt1/2"CA4 —
0 MANAGER �OPFlad 10605CE a o
v
® ® a, MIA
1 4
�I13 Ews132 inErs 30R 1 IX14Eq 5 III 1 1 HRRECEPION 3
4
101
INr. 1zs
FF o II m 4 N 1/2"cA
- II
u2'CA_11/4"Hw 14"HWC uz'cA — — 104
^
tas - - - - - OFFICE - OFFCE123 - - - - - - - -
EMST. BREAKROOM 1N 107
CW DH
LI
❑ — — — — — —1i— — — — r — o — — — —�
C
F I
— — For,
— — — — U OFFI
ryr INT 13d I HUMAN RESOUR \ x15
j COFFEE
COFFEE 0
38
O
P LORRY
I�A
- - - - CORRIDOR - - I___L - - - - 1/2"CA - - - - - - - - - HE CONFERENCEC-15 - - - - - - - - - - - -
II TESTING
E;e3
❑EEE
_ L
I I I I I I I I I I
— t — — — — -- — — — — — — — — — — — - — — — -—
FIRST FLOOR PLUMBING PLAN -AREA A
;R1
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Carmel
1M11IN IDAIM AS>Z
DATE: 03/15/19
_ 1 jlr
7
I
NOT KEYSTONE XNI SUITE 210
INDIANAPOLIS. IN RANT
I MEG
XUUI PROPERTY OF MI CORPANDSI NOT BE USEDOR
ODUCED FORANI PROJECT WITHOUT THE EKPIRIESS WRITTEN
DVALAND PARTICIPATION OF RACE CORP 6211181IMEG(OCIRIP
REFEIRENCE SCALE IN INCHES
co
OAMERICAN
No STRUCTUREPOINT
7260 Saedeland Sodium I Indianapolis, Indiana 48a56
TEL 317.547.5580 1 TAX 317.513.000
wwn.mmnMrepeim.nom
6, ] mur I = 0 -A
8900 KEYSTONE XING PH: 317.848.5045
SUITE 210 FAX 317.844.2201
INDIANAPOLIS, IN www.imegeorp.com
46240
GEICO CORPORATE
FIRST FLOOR
RENOVATION
101 W. 103RD ST.
INDIANAPOLIS, IN 46290
1n�
/ CERTIFIED BY
ISSUANCE INDEX
DATE:
07/06/18
PROJECT PHASE:
CONSTRUCTION DOCUMENTS
REVISION SCHEDULE
NO.
DESCRIPTION
DATE
1
ADDENDUM 001
07-19-18
2
PIR N
08-08-18
3
PR-009
10-2418
4
PR-013
01-31-19
Project Number 18002480.00
FIRST FLOOR
PLUMBING PLAN -
AREA A
P301 OA