HomeMy WebLinkAboutP301.AKEYNOTES: 1. 2-112" COLD WATER DROP. 2. 1" HOT AND COLD WATER DROP, 2" VENT RISE, 2" WASTE DROP. 3. 3/4" HOT AND COLD WATER DROP. 4. CAP BRANCH PIPE ABOVE CEILING. 5. 4" VENT DROP. 6. 3/4" HOT WATER DROP. 'A A. e6 B. eC eD eE eF eG eH el eJ eK ORRg0R G5 STOP TR4sNMTRsN TRANIANO �TNNI COI COrvE1EFlE CE iiR ING 150 lu TEARING TEARING IE 11/2"CW 1/2"CA Ili lil GENERAL NOTES: A. ALL EQUIPMENT AND PIPING SHOWN WITH THIN/LIGHT SOLID LINES IS EXISTING TO REMAIN. B. ALL EQUIPMENT AND PIPING SHOWN WITH THICK/DARK SOLID LINES IS NEW OR RELOCATED. C. RELEVANT EQUIPMENT AND PIPING SHOWN IS BASED ON EXISTING DRAWINGS AND FIELD SURVEY. NOT ALL EXISTING EQUIPMENT AND PIPING IS SHOWN. CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AFFECTED BY THIS RENOVATION AND NOTIFY THE ENGINEER IF CONDITIONS ARE NOT AS INDICATED. D. DOMESTIC WATER BRANCH PIPING RUN OUTS TO PLUMBING FIXTURES SHALL BE 314. DIAMETER, UNLESS OTHERWISE NOTED. E. REMOVE AND RE -INSTALL EXISTING LAY -IN CEILING AS REQUIRED TO COMPLETE WORK. REPLACE DAMAGED CEILING MATERIALS TO MATCH EXISTING CEILING. F. REMOVE EXISTING DRYWALL CEILINGS AS REQUIRED TO COMPLETE WORK. PATCH AND PAINT CEILINGS TO MATCH EXISTING CONDITIONS. G. REMOVE EXISTING DRYWALUMASONRY WALLS AS REQUIRED TO COMPLETE WORK. PATCH AND PAINT WALLS TO MATCH EXISTING CONDITIONS. I of 1 H. THE FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR THE DESIGN, COORDINATION, AND INSTALLATION OF THE FIRE PROTECTION SYSTEM, INCLUDING REMOVING AND INSTALLING NEW PIPING AS REQUIRED FOR A COORDINATED INSTALLATION. THE FIRE PROTECTION SYSTEM IS TO BE DESIGNED AND INSTALLED IN COMPLIANCE WITH NFPA AND ALL OTHER STATE AND LOCAL CODES. 4 I'I n cA — — — ——1/2'ca , 1/2"SAN — — — - - N 2 L-2 N Ii j l 196 CO H L I I I I f I I I I I I I I � C 1 1 `� 1� I sH ER y ,5 w o 9/ WC7 3 3 CORRIDOR 3/4" WC-1 WC-1 WC-1 C-2 WC-2 Q CORRIDOR U 2 4 C4 U 4 Ii i EWC-1 SH-1 METHE E0JWE o 0 05 6 -1 1 C o 1/2"C 1 N SH-1 CO 4• 3 SH- R-1 UR-1 UR-2 ,F iCORRIDOR FILE SIORPGE ICE OFF ICE WC- N 3 WC-1 C-1 C-2 • F " Gil n7 FFl B i 1/2"CAFRI - 1m 1 1 119 1 1151 1 M 1 sH AR 1/2"CA 3 ," DAS WER -- -3N- --r 3"V— i-3W 2"V NEW MENS ' 2N- 1 112Vw,f u I NL TRAINING lk 7FN vz^cA z 112"Cw L-z L-z L-z L-z % o 10 > 14 MB-1 1 1/4"HW 1czA ❑ ❑ SI 4 MERGERLL I', H 1� y rA II 12 LV f Cz __— NC — — — — — a — — — — — — - ---PPoM 34"cW e5 -------------------- 1/2"CW 1/2"CA MINT u, n�a 1/2"CAHPoNil ECFUIRNG — — — — —— =PLESiOR. [N S E — — — —IXISLWOMENG 110 IG3 1 2"CA 121 / CORRIDORC4 1 1/4"V- Q CONFERENCELF� Io ®®® n3N ioEws10RA . 1 �> EwsT 1A 1mnt1/2"CA4 — 0 MANAGER �OPFlad 10605CE a o v ® ® a, MIA 1 4 �I13 Ews132 inErs 30R 1 IX14Eq 5 III 1 1 HRRECEPION 3 4 101 INr. 1zs FF o II m 4 N 1/2"cA - II u2'CA_11/4"Hw 14"HWC uz'cA — — 104 ^ tas - - - - - OFFICE - OFFCE123 - - - - - - - - EMST. BREAKROOM 1N 107 CW DH LI ❑ — — — — — —1i— — — — r — o — — — —� C F I — — For, — — — — U OFFI ryr INT 13d I HUMAN RESOUR \ x15 j COFFEE COFFEE 0 38 O P LORRY I�A - - - - CORRIDOR - - I___L - - - - 1/2"CA - - - - - - - - - HE CONFERENCEC-15 - - - - - - - - - - - - II TESTING E;e3 ❑EEE _ L I I I I I I I I I I — t — — — — -- — — — — — — — — — — — - — — — -— FIRST FLOOR PLUMBING PLAN -AREA A ;R1 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Carmel 1M11IN IDAIM AS>Z DATE: 03/15/19 _ 1 jlr 7 I NOT KEYSTONE XNI SUITE 210 INDIANAPOLIS. IN RANT I MEG XUUI PROPERTY OF MI CORPANDSI NOT BE USEDOR ODUCED FORANI PROJECT WITHOUT THE EKPIRIESS WRITTEN DVALAND PARTICIPATION OF RACE CORP 6211181IMEG(OCIRIP REFEIRENCE SCALE IN INCHES co OAMERICAN No STRUCTUREPOINT 7260 Saedeland Sodium I Indianapolis, Indiana 48a56 TEL 317.547.5580 1 TAX 317.513.000 wwn.mmnMrepeim.nom 6, ] mur I = 0 -A 8900 KEYSTONE XING PH: 317.848.5045 SUITE 210 FAX 317.844.2201 INDIANAPOLIS, IN www.imegeorp.com 46240 GEICO CORPORATE FIRST FLOOR RENOVATION 101 W. 103RD ST. INDIANAPOLIS, IN 46290 1n� / CERTIFIED BY ISSUANCE INDEX DATE: 07/06/18 PROJECT PHASE: CONSTRUCTION DOCUMENTS REVISION SCHEDULE NO. DESCRIPTION DATE 1 ADDENDUM 001 07-19-18 2 PIR N 08-08-18 3 PR-009 10-2418 4 PR-013 01-31-19 Project Number 18002480.00 FIRST FLOOR PLUMBING PLAN - AREA A P301 OA