Loading...
HomeMy WebLinkAboutAT-2 PROPOSED FLOOR PLANGENERAL PROPOSED PLAN NOTES DOOR SCHEDULE DOOR TYPES HEAD AND JAMB DETAIL 1. ALL EXPOSED EDGES AND/OR CORNERS ON ALL PAINTED No Location Type Size Security Description Frame Hardware Details Note DRYWALL CONSTRUCTION SHALL RECEIVE A METAL BEAD, WHICH Y I N Mal. Finish Glass Material Finish Set Head Jamb Thresh IS TO BE TAPED AND FLOATED SMOOTH. 1 Main Suite Entry Doc A 3'-0" x 8'-0" x 1/2" :t EXISTING Yes EXISTING 1 EXISTING 2 101 B T-0" x 8'-0" x 1 3/4" * SCW PTD No 2 H1 J1 Paint door and frame P-1 (glossy finish) 2. WHERE NEW WALLS ARE TO ALIGN WITH EXISTING WALLS AND/ 3 101 B T-0% 8'-0% 13/4" * SCW PTD No 2 H1 11 Paint door and frame P-1(glossy finish) SEE PARTITION TYPES OR COLUMNS, REMOVE EXISTING CORNER BEAD. TAPE, SPACKLE 4 Suite Back Door A Tix 8'-0%1/2" * EXISTING Yes EXISTING 1 EXISTING o ADJ. ANCHOR SINGLE ENTRANCE LOCK SET W/ CLOSER ENTRANCE FUNCTION: ANSI A156.2, NP F82 FORT' DIMENSION AND SAND SMOOTH JOINTS AS NECESSARY TO A POINT ALONG (4 PER JAMB) THE EXISTING WALL SO THAT NEW FINISH IS NOT OBVIOUS. 1/ T �1/2 DOUBLE STUDS MAG-LOK EITHER LEVER OR KNOB OPERATES LATCHBOLT (EXCEPT WHEN OUTSIDE LEVER IS VARIES 5/8', 1 HINGES LOCKED FROM INSIDE). PUSHING BUTTON IN INSIDE LEVER LOCKS OUTSIDE LEVER GYPSUM BOARD @ALL JAMBS v 2„ ( o 3. ALL WOOD PRODUCTS TO BE FIRE RATED, IF REQUIRED BY CLOSER (AUTOMATICALLY RELEASES WHEN INSIDE LEVER IS TURNED OR KEY IS ROTATED IN G SEE SCHEDULE GOVERNING BUILDING AUTHORITIES. FLOOR STOP LOCKED OUTSIDE LEVER). LATCHBOLT IS OPERATED BY KEY IN OUTSIDE LEVER OR BY PANIC HARDWARE ROTATING INSIDE LEVER. INSIDE LEVER IS ALWAYS ACTIVE. + A- SUITE ENTRY FLEX. SEALANT SEE PARTITION m 4. SUSPENDED CEILING TILE GRID, BULKHEADS, ETC. SHALL BE DOORS AFF = @ FRAME PERIMETER TYPES FOR F w SUSPENDED FROM STRUCTURAL DECK ABOVE ONLY. SINGLE INTERIOR LOCK SET W/ CLOSER PRIVACY FUNCTION: ANSI A156.2, NO. F76 of METAL FRAME, PTD 'T' DIMENSION ¢ LOCK SET -PRIVACY EITHER LEVER OR KNOB OPERATES LATCHBOLT UNLESS OUTSIDE LEVER IS LOCKED BY � > HINGES PUSH BUTTON INSIDE. BUTTON AUTOMATICALLY RELEASES WHEN INSIDE LEVER IS 3'-0" SEE DOOR iw 5. ALL VERTICAL DIMENSIONS TO BE MADE FROM THE HIGHEST 1 15/16" CLOSER TURNED OR DOOR IS CLOSED. EMERGENCY RELEASE IS IN OUTSIDE LEVER. INSIDE LEVER SCHEDULE SEE DOOR POINT OF FLOOR SLAB TO ENSURE PROPER ALIGNMENT OF ALL FLOOR STOP IS ALWAYS ACTIVE. 5/8" }- FLEXIBLE SEALANT SCHEDULE DOORS, BULKHEADS, ETC. T+1" FOR KNOCK DOWN @FRAME PERIMETER TG = TEMPERED GLASS T+1 1/8" FOR WELDED METAL FRAME, PTD 6. LOCATE INSIDE EDGE OF ALL DOOR FRAMES 6 INCHES FROM THE ADJACENT PERPENDICULAR WALL AT INSIDE OF CORNERS, The Glass walls shall meet the Safety Glazing Criteria outlined in IBC 2012 Section 2406. 4 SEE SCHEDULE FOR SIZE VARIATIONS SEE SCHEDULE FOR SIZE VARIATIONS UNLESS OTHERWISE NOTED (U.O.N.), IN ACCORDANCE WITH UFAS CO SEE SCHEDULE FOR REQ'D FIRE RATING SEE SCHEDULE FOR REQ'D FIRE RATING AND ADA. The glass shall pass impact testing outlined in Section 2406.2 TYP. HEADER DETAIL TYP. JAMB DETAIL 7. ALL PENETRATIONS OF FIRE RATED ASSEMBLIES (FLOORS, Identification of safety glazing shall be done per section 2406.3 \%' NOT TO SCALE <NOT TO SCALE WALLS AND/ OR CEILINGS) SHALL BE FIRE STOPPED TO COMPLY B - INTERIOR DOORS WITH APPLICABLE CODES AND IN ACCORDANCE WITH UL Glass shall meet the criteria set out by section 2406.4.2 Glazing adjacent to doors - HAZARDOUS AREA STANDARDS. 8. DRAWINGS ARE NOT TO BE SCALED - DIMENSIONS GOVERN. 9. WHERE DIMENSIONS ARE OMITTED ON DRAWINGS, LOCATE NEW WALLS, PARTITIONS, OR OTHER FEATURES IN SELF-EVIDENT POSITIONS (I.E. ALIGNED WITH THE FACE OF EXISTING WALL PARTITION OR COLUMN, CENTERS ON OPENING, COLUMN, MULLION, SPACE, ETC.). 10. INSTALL NEW FRAMES, DOORS, AND HARDWARE IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS. 11. ALL PARTITIONS, DOORS, HARDWARE, AND OTHER CONSTRUCTION ITEMS SHALL BE PROVIDED AS DESCRIBED IN THESE DOCUMENTS, AND IN COMPLIANCE WITH GOVERNMENT REQUIREMENTS, IN COMBINATION WITH EXISTING BUILDING STANDARDS. ALL HARDWARE SHALL MEET THE REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT (ADA) AND PROJECT REQUIREMENTS. SPECIAL HARDWARE TO BE PROVIDED AS NOTED IN THESE DRAWINGS (IF APPLICABLE), U.O.N. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL FLOOR AND CEILING FINISHES TO ENSURE THAT JOINTS AND TRANSITIONS BETWEEN MATERIALS, WHETHER THEY BE WALL TO FLOOR, FLOOR TO FLOOR, WALL TO CEILING, OR CEILING TO CEILING, WILL BE SMOOTH, TRUE, LEVEL, AND IN ACCORDANCE WITH DRAWINGS, SPECIFICATIONS, AND SCHEDULES. 13. ALL DRYWALL PARTITIONS SHALL BE DIMENSIONED FROM FINISH FACE TO FINISH FACE, U.O.N. 14. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, INCLUDING MECHANICAL, NECESSARY TO COMPLETE THE SCOPE OF WORK PRIOR TO DEMOLITION OR CONSTRUCTION BEGINS. CONTRACTOR SHALL COORDINATE ALL MECHANICAL ITEMS WITH MECHANICAL ENGINEERS TO ENSURE SAFE, PROPER INSTALLATION OF CEILING TILE GRID, PARTITIONS, MECHANICAL DUCT WORK, ELECTRICAL CONDUIT, ETC. PROPOSED FLOOR PLAN KEY NOTES O KEEP THIS AREA CLEAR FOR 31 . 2Q CREATE CASED OPENING PROPOSED FLOOR PLAN SYMBOLS WALLTYPEID Ox DOOR ID RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel ��Gs DATE: 03/25/19 BREAK LAUNDRY PROPOSED FLOOR PLAN r Scale: 1/a"= V-V WALL TYPES FL( 5/8" GYP. BD. BOTH SIDES 2 1/2" MTL. STUDS @ 24" O.C. MAX. W/ TOP AND BOTTOM RUNNERS EXTENDING FROM FIN. FLOOR TO UNDERSIDE OF STRUCTURE ONE LAYER OF 5/8" GYP. BD., SCREWED TO STUDS, ON EACH SIDE OF STEEL STUDS. EXTEND GYP BD. THE FULL HEIGHT OF PARTITION. TYP. NON -BEARING PARTITION NOT TO SCALE 5/8" GYP. BD. BOTH SIDES 3 1/2" MTL. STUDS @ 24" O.C. MAX. W/TOP AND BOTTOM RUNNERS EXTENDING FROM FIN. FLOOR TO UNDERSIDE OF STRUCTURE. ONE LAYER OF 5/8" GYP. BD., SCREWED TO STUDS, ON EACH SIDE OF STEEL STUDS. EXTEND GYP BD. THE FULL HEIGHT OF PARTITION. ^TYP. NON -BEARING PARTITION GREEN BOARD ON PLUMBING SIDE SOUND ATTENUATION 5/8" GYP. BD. BOTH SIDES 3 1/2" MTL. STUDS @ 24" O.C. MAX. W/TOP AND BOTTOM RUNNERS EXTENDING FROM FIN. FLOOR TO UNDERSIDE OF STRUCTURE. ONE LAYER OF 5/8" GYP. BD., SCREWED TO STUDS, ON EACH SIDE OF STEEL STUDS. EXTEND GYP BD. THE FULL HEIGHT OF PARTITION. TYP. NON -BEARING PARTITION EEN 3 GRBOARD ON PLUMBING SIDE Sce Lin & Associates, LLC 4340 East West Highway Suite 105 Bethesda, Maryland 20814 USA 301.986-9300 Fax.986-0500 Notes Consultants Own By Chkd By Job No. Project NAIL SALON 7245 EAST146th ST SUITE 130 CARMEL, IN 46033 ZUMOT REAL ESTATE MGMT. Drawing Title PROPOSEDFLOOR PLAN Sheet No. AT-2