HomeMy WebLinkAboutAT-4 PROPOSED POWER AND FINISH PLANSPOWER PLAN KEY NOTES
O COORDINATE WITH WASHERIDRYER SPECS FOR HEIGHT
PLACEMENT
POWER PLAN SYMBOLS
�- TELEPHONE/DATA RECEPTACLE
DUPLEX OUTLET
30 AMP DEDICATED OUTLET - COORDINATE WITH DRYER
SPECIFICATIONS
QUAD OUTLET
CORE DRILL
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
�;, Gs
DATE: 03/25/19
MATERIAL SCHEDULE
MARK DESCRIPTION MANUFACTURER MODEL. No. COLOR REMARKS
P-1 PAINT BEHR AK1410 N500-2: LOFT SPACE BEHR
P-2 PAINT BEHR AK1413 N500-5: MAGNETIC GRAY BEHR
F-1 LVT SHAW 0945V: SHEAR 45515: CARRERA LAY IN J TURN PATTERN
F-2 VCT ARMSTRONG EXCELON 51973: MONO WHITE VCT
VB-1 VINYL BASE ROPPE COVE PROFILE 100: BLACK USE COILS TO MINIMIZE JOIN
PL-1 P-LAM FORMICA 912-58 STORM MATTE FINISH
PL-2 I P-LAM I FORMICA 1994-58 IFOX MATTE FINISH
GENERAL FINISH NOTES
1. ALL MATERIALS SHALL BE APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS.
2. ALL MATERIALS SHALL BE PROVIDED AS SPECIFIED WITH NO "APPROVED EQUAL" SUBSTITUTIONS, UNLESS AUTHORIZED IN WRITING
3. CONTRACTOR SHALL BE SUBJECT TO ADJUSTMENTS OR CHANGE ON SITE.
4. PAINT GRADE DOORS, METAL FRAMES, AND PAINT GRADE WOOD FRAMES, SHALL BE PAINTED A SEMI -GLOSS FINISH TO MATCH THE WALL IN
WHICH THEY OCCUR. (U.O.N.)
5. FLOORING SHALL BE INSTALLED IN THE STANDARD "GLUE DOWN" METHOD, IN ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS.
6. CONTRACTOR SHALL PROVIDE A PRIMER AND TWO TOP COATS ON ALL PAINTED AREAS.
BREAK LAUNDRY
PROPOSED POWER PLAN
Scale: 1/8"- 1'-0"
FINISH PLAN KEY NOTES
O CONTRACTOR TO PROVIDE TRANSITION STRIP BETWEEN
FLOORING MATERIALS.
FINISH PLAN SYMBOLS
i
FINISHES CODE - SEE MATERIALS SCHEDULE
BREAK LAUNDRY
wio
DOWN SPOUT
❑ ❑
❑ ❑
❑ ❑
❑ ❑ PEDICURE
AREA
102
Ft MANICURE
F-1 AREA
WAITING
AREA
PROPOSED FINISH PLAN
Scale: 1/8"= 1'-0"
GENERAL PROP. POWER PLAN NOTES
1. ELECTRICAL ENGINEER TO DETERMINE THE MAXIMUM NUMBER OF
ELECTRICAL OUTLETS PER CIRCUIT ON ELECTRICAL EQUIPMENT
AND CODE REQUIREMENTS.
2. ALL DOOR SWINGS TO BE VERIFIED TO INSTALLING LIGHT
SWITCHES. SWITCHES SHALL BE ON LEVER SIDE OF DOOR AND
SHALL BE 42" AFF. IN CASE OF CONFLICT, NOTIFY ARCHITECT
PRIOR TO INSTALLATION.
3. NOT USED
4. ALL OUTLETS INSTALLED I8"AFF; JOIN.
5. ELECTRICAL CONTRACTOR SHALL PROVIDE SUFFICIENT WIRING
AND LENGTHS OF CABLE TO REACH LOCATIONS DESIGNATED ON
PLAN THROUGH LOW/ FULL HEIGHT PARTITIONS, WIRE MOLD, ETC.
TO FINAL INSTALLATION AND HOOK-UP OF DEVICES.
6. DRAWING DIMENSIONS GOVERN.
7. ALL MOUNTED HEIGHTS INDICATED ARE TO CENTER LINE OF
OUTLET DEVICES; UON.
8. ELECTRICAL WORK AND MATERIALS SHALL COMPLY WITH ALL
CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN
REQUIREMENTS, THE MOST RESTRICTIVE SHALL APPLY.
9. OUTLETS MOUNTED ON OPPOSITE SIDE OF PARTITIONS ARE NOT
TO BE MOUNTED BACK TO BACK.
10. BRACE AND SECURE ALL CONDUIT, COMMUNICATION AND POWER
OUTLET BOXES THAT FALL BETWEEN METAL STUDS W/ METAL
STRAPS SO OUTLETS ARE LOCATED AS SHOWN (AS REQUIRED).
11. COORDINATE WITH PARTITION, FURNITURE, MILLWORK, ETC. FOR
ANY CONFLICT IN LOCATION AND DIMENSION OF POWER OUTLETS.
12. CONTRACTOR SHALL COORDINATE LOCATIONS OF ELECTRICAL
DEVICES WITH FURNITURE VENDER. REFER TO THE ELECTRICAL
PLAN FOR APPROXIMATE LOCATIONS OF THE ELECTRICAL
DEVICES.
GENERAL PROPOSED FINISH PLAN NOTES
1. ALL EXPOSED EDGES AND/OR CORNERS ON ALL PAINTED
DRYWALL CONSTRUCTION SHALL RECEIVE A METAL BEAD
WHICH IS TO BE TAPED AND FLOATED SMOOTH.
2. WHERE NEW WALLS ARE TO ALIGN WITH THE EXISTING WALLS
AND/OR COLUMNS, REMOVE EXISTING CORNER BEAD. TAPE,
SPACKLE AND SAND SMOOTH ALL NECESSARY JOINTS TO A
POINT ALONG THE EXISTING WALL SO THAT NEW FINISH IS
NOT OBVIOUS.
3. ALL WOOD PRODUCTS TO BE FIRE -RATED IF REQUIRED BY
GOVERNING BUILDING AUTHORITIES.
4. FLOOR SLAB SHALL BE FLASH -PATCHED SMOOTH AS
REQUIRED TO ACCEPT NEW FLOOR FINISHES.
5. INSTALL NEW FRAMES, DOORS, AND HARDWARE IN
ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.
6. ALL PARTITIONS, DOORS, HARDWARE, AND OTHER
CONSTRUCTION ITEMS SHALL BE PROVIDED AS DESCRIBED IN
THESE DOCUMENTS AND IN COMBINATION WITH EXISTING
BUILDING STANDARD AND GOVERNMENT REQUIREMENTS. ALL
HARDWARE SHALL MEET THE REQUIREMENTS OF THE
AMERICANS WITH DISABILITIES ACT (ADA) AND PROJECT
REQUIREMENTS. SPECIAL HARDWARE TO BE PROVIDED AS
NOTED IN THESE DRAWINGS (IF APPLICABLE), U.O.N.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATING ALL FLOOR AND CEILING FINISHES TO ENSURE
THAT JOINTS AND TRANSITIONS BETWEEN MATERIALS,
WHETHER THEY BE WALL TO FLOOR, FLOOR TO FLOOR, WALL
TO CEILING OR CEILING TO CEILING, WILL BE SMOOTH, TRUE,
LEVEL AND IN ACCORDANCE WITH DRAWINGS,
SPECIFICATIONS, AND SCHEDULES.
8. IN ALL USE AREAS THE INTERIOR WALL FINISHES SHALL BE
CLASS A, B, OR C IN ACCORDANCE WITH TABLE 803.9 AND
SHALL ALSO COMPLY WITH NFPA SECTION 10.2. INTERIOR
FLOOR SHALL BE IN ACCORDANCE WITH IBC 2012 SECTION 804
& NFPA 10138.3.3.3 & 10.2.7.
Soe Lin & Associates, LLC
4340 East West Highway
Suite 105
Bethesda, Maryland
20814 USA
301.986-9300
Fax.986-0500
Notes Consultants
Dwn By
Chkd By
Job No.
Project
NAIL SALON
7245 EAST146th ST
SUITE 130
CARMEL, IN 46033
ZUMCIT REAL ESTATE MGMT.
Drawing Title
PROPOSED POWER &
FINISH PLANS
Sheet No.
AT-4