Loading...
HomeMy WebLinkAboutAT-4 PROPOSED POWER AND FINISH PLANSPOWER PLAN KEY NOTES O COORDINATE WITH WASHERIDRYER SPECS FOR HEIGHT PLACEMENT POWER PLAN SYMBOLS �- TELEPHONE/DATA RECEPTACLE DUPLEX OUTLET 30 AMP DEDICATED OUTLET - COORDINATE WITH DRYER SPECIFICATIONS QUAD OUTLET CORE DRILL RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �;, Gs DATE: 03/25/19 MATERIAL SCHEDULE MARK DESCRIPTION MANUFACTURER MODEL. No. COLOR REMARKS P-1 PAINT BEHR AK1410 N500-2: LOFT SPACE BEHR P-2 PAINT BEHR AK1413 N500-5: MAGNETIC GRAY BEHR F-1 LVT SHAW 0945V: SHEAR 45515: CARRERA LAY IN J TURN PATTERN F-2 VCT ARMSTRONG EXCELON 51973: MONO WHITE VCT VB-1 VINYL BASE ROPPE COVE PROFILE 100: BLACK USE COILS TO MINIMIZE JOIN PL-1 P-LAM FORMICA 912-58 STORM MATTE FINISH PL-2 I P-LAM I FORMICA 1994-58 IFOX MATTE FINISH GENERAL FINISH NOTES 1. ALL MATERIALS SHALL BE APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. 2. ALL MATERIALS SHALL BE PROVIDED AS SPECIFIED WITH NO "APPROVED EQUAL" SUBSTITUTIONS, UNLESS AUTHORIZED IN WRITING 3. CONTRACTOR SHALL BE SUBJECT TO ADJUSTMENTS OR CHANGE ON SITE. 4. PAINT GRADE DOORS, METAL FRAMES, AND PAINT GRADE WOOD FRAMES, SHALL BE PAINTED A SEMI -GLOSS FINISH TO MATCH THE WALL IN WHICH THEY OCCUR. (U.O.N.) 5. FLOORING SHALL BE INSTALLED IN THE STANDARD "GLUE DOWN" METHOD, IN ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS. 6. CONTRACTOR SHALL PROVIDE A PRIMER AND TWO TOP COATS ON ALL PAINTED AREAS. BREAK LAUNDRY PROPOSED POWER PLAN Scale: 1/8"- 1'-0" FINISH PLAN KEY NOTES O CONTRACTOR TO PROVIDE TRANSITION STRIP BETWEEN FLOORING MATERIALS. FINISH PLAN SYMBOLS i FINISHES CODE - SEE MATERIALS SCHEDULE BREAK LAUNDRY wio DOWN SPOUT ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ PEDICURE AREA 102 Ft MANICURE F-1 AREA WAITING AREA PROPOSED FINISH PLAN Scale: 1/8"= 1'-0" GENERAL PROP. POWER PLAN NOTES 1. ELECTRICAL ENGINEER TO DETERMINE THE MAXIMUM NUMBER OF ELECTRICAL OUTLETS PER CIRCUIT ON ELECTRICAL EQUIPMENT AND CODE REQUIREMENTS. 2. ALL DOOR SWINGS TO BE VERIFIED TO INSTALLING LIGHT SWITCHES. SWITCHES SHALL BE ON LEVER SIDE OF DOOR AND SHALL BE 42" AFF. IN CASE OF CONFLICT, NOTIFY ARCHITECT PRIOR TO INSTALLATION. 3. NOT USED 4. ALL OUTLETS INSTALLED I8"AFF; JOIN. 5. ELECTRICAL CONTRACTOR SHALL PROVIDE SUFFICIENT WIRING AND LENGTHS OF CABLE TO REACH LOCATIONS DESIGNATED ON PLAN THROUGH LOW/ FULL HEIGHT PARTITIONS, WIRE MOLD, ETC. TO FINAL INSTALLATION AND HOOK-UP OF DEVICES. 6. DRAWING DIMENSIONS GOVERN. 7. ALL MOUNTED HEIGHTS INDICATED ARE TO CENTER LINE OF OUTLET DEVICES; UON. 8. ELECTRICAL WORK AND MATERIALS SHALL COMPLY WITH ALL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN REQUIREMENTS, THE MOST RESTRICTIVE SHALL APPLY. 9. OUTLETS MOUNTED ON OPPOSITE SIDE OF PARTITIONS ARE NOT TO BE MOUNTED BACK TO BACK. 10. BRACE AND SECURE ALL CONDUIT, COMMUNICATION AND POWER OUTLET BOXES THAT FALL BETWEEN METAL STUDS W/ METAL STRAPS SO OUTLETS ARE LOCATED AS SHOWN (AS REQUIRED). 11. COORDINATE WITH PARTITION, FURNITURE, MILLWORK, ETC. FOR ANY CONFLICT IN LOCATION AND DIMENSION OF POWER OUTLETS. 12. CONTRACTOR SHALL COORDINATE LOCATIONS OF ELECTRICAL DEVICES WITH FURNITURE VENDER. REFER TO THE ELECTRICAL PLAN FOR APPROXIMATE LOCATIONS OF THE ELECTRICAL DEVICES. GENERAL PROPOSED FINISH PLAN NOTES 1. ALL EXPOSED EDGES AND/OR CORNERS ON ALL PAINTED DRYWALL CONSTRUCTION SHALL RECEIVE A METAL BEAD WHICH IS TO BE TAPED AND FLOATED SMOOTH. 2. WHERE NEW WALLS ARE TO ALIGN WITH THE EXISTING WALLS AND/OR COLUMNS, REMOVE EXISTING CORNER BEAD. TAPE, SPACKLE AND SAND SMOOTH ALL NECESSARY JOINTS TO A POINT ALONG THE EXISTING WALL SO THAT NEW FINISH IS NOT OBVIOUS. 3. ALL WOOD PRODUCTS TO BE FIRE -RATED IF REQUIRED BY GOVERNING BUILDING AUTHORITIES. 4. FLOOR SLAB SHALL BE FLASH -PATCHED SMOOTH AS REQUIRED TO ACCEPT NEW FLOOR FINISHES. 5. INSTALL NEW FRAMES, DOORS, AND HARDWARE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 6. ALL PARTITIONS, DOORS, HARDWARE, AND OTHER CONSTRUCTION ITEMS SHALL BE PROVIDED AS DESCRIBED IN THESE DOCUMENTS AND IN COMBINATION WITH EXISTING BUILDING STANDARD AND GOVERNMENT REQUIREMENTS. ALL HARDWARE SHALL MEET THE REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT (ADA) AND PROJECT REQUIREMENTS. SPECIAL HARDWARE TO BE PROVIDED AS NOTED IN THESE DRAWINGS (IF APPLICABLE), U.O.N. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL FLOOR AND CEILING FINISHES TO ENSURE THAT JOINTS AND TRANSITIONS BETWEEN MATERIALS, WHETHER THEY BE WALL TO FLOOR, FLOOR TO FLOOR, WALL TO CEILING OR CEILING TO CEILING, WILL BE SMOOTH, TRUE, LEVEL AND IN ACCORDANCE WITH DRAWINGS, SPECIFICATIONS, AND SCHEDULES. 8. IN ALL USE AREAS THE INTERIOR WALL FINISHES SHALL BE CLASS A, B, OR C IN ACCORDANCE WITH TABLE 803.9 AND SHALL ALSO COMPLY WITH NFPA SECTION 10.2. INTERIOR FLOOR SHALL BE IN ACCORDANCE WITH IBC 2012 SECTION 804 & NFPA 10138.3.3.3 & 10.2.7. Soe Lin & Associates, LLC 4340 East West Highway Suite 105 Bethesda, Maryland 20814 USA 301.986-9300 Fax.986-0500 Notes Consultants Dwn By Chkd By Job No. Project NAIL SALON 7245 EAST146th ST SUITE 130 CARMEL, IN 46033 ZUMCIT REAL ESTATE MGMT. Drawing Title PROPOSED POWER & FINISH PLANS Sheet No. AT-4