Loading...
HomeMy WebLinkAboutCS - COVER SHEETGENERAL NOTES SYMBOLS PROJECT INFORMATION PROJECT DIRECTORY INDEX OF DRAWINGS 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWING AT THE JOB SITE AND SHALL NOTIFY THE ARCHITECT AND THE OWNER OF ANY DISCREPANCIES, OMISSIONS, AND/OR L_ x� WALL SECTION NO. PROJECT DESCRIPTION: EXISTING RAW UNFINISHED SPACE. OWNER: TIN TIN, LLC ARCHITECTURAL DRAWINGS CONFLICTS BEFORE PROCEEDING WITH THE JOB. A�T- SHEET NO. PROVIDE NEW WALLS, NEW P.O. BOX 370 2. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. LARGE SCALE DETAILS GOVERN SMALL SCALE PLANS. CEILING, MCLEAN, VA 22101 (703) 893-7233 CS COVER SHEETP. F. (703) 893-5267 AT-1 OCCUPANCY DIAGRAM &NEW CONCRETE PLAN 3. ALL WORK SHALL CONFORM TO STATE AND LOCAL BUILDING CODES, FIRE, HEALTH, WSSC, ETC. SECTIONAL DETAIL NO. � AT-2 PROPOSED FLOOR PLAN SHEET NO. AT-4 PROPOSED RCP 4. ALL PARTITIONS ARE DIMENSIONED TO OUTSIDE SURFACE, UNLESS OTHERWISE NOTED U.O.N.) ( PROJECT LOCATION: 7245 EAST 146TH ST. AT-4 PROPOSED POWER AND FINISH PLANS SUITE 130 ARCHITECT: SOE LIN AND ASSOCIATES, LLC AT-5 ELEVATIONS AND SECTIONS 5. CONTRACTOR SHALL BE RESPONSIBLE FOR THE BRACING AND BLOCKING OF WALLS RECEIVING x DETAIL TARGET, ENLARGEMENT CARMEL, IN 46033 4340 EAST WEST HIGHWAY MILLWORK, SHELVING, ETC. - SHEET NO. SUITE 105 BETMD 20814 6. WHERE A VINYL BASE IS SPECIFIED, SETABOVE CARPET. CODES: IBC 2012 P. (301) 1) 98686-9300 MEP DRAWINGS 7. ALL FLOORS SHALL BE LEVELED AND FREE OF IRREGULARITIES TO ASSURE ONE CONSTANT FLOOR A AAAAAA INTERIOR ELEVATION SYMBOL NFPA 13-2010 IMC 2012 F. (301) 986-0500 MIA HVAC SPECIFICATIONS HEIGHT SO THAT DOOR BUCKS, WHEN SET, ARE AT CONSISTENT DIMENSIONS FROM THE CEILING, WITH DDRAWING NO. IPC 2006 MpE THE ENGINEERING COLLABORATION M-2 HVAC FLOOR PLAN NO GAPS BETWEEN THE BOTTOM OF THE DOOR BUCK AT THE SLAB AFTER CARPETING AND OTHER SHEET NO. NEC 2008 ENGINEERS: EXECUTIVE DRIVE M-3 HVAC DETAILS FLOOR FINISHES ARE INSTALLED. ANY UNAVOIDABLE CHANGES IN THE FLOOR HEIGHT SHALL BE CABO/ANSI SUIT SUITE 100 M-4 HVAC GENERAL NOTES GRADUALLY RAISED AND TROWELED TO CREATE A RAMP -LIKE EFFECT. ALL DEPRESSIONS, CRACKS, A117.1-2009 INDIANAPOLIS, IN 46241 MEP-1 MEP UNDERGROUND PLAN SCREEDS, AND EXPANSION JOINTS ARE TO BE FILLED WITH A GOOD GRADE NON -CRUMBLING LATEX BASE 1xx AREA DESIGNATION/ FLASHING COMPOUND, WATER PUTTY OR CRACK FILLER. ROOM NUMBER USE GROUP / BUILDING B-BUSINESS P. (317) 636-3941 P-1 PLUMBING SPECIFICATIONS OCCUPANCYGROUP: P-2 PLUMBING PLAN 8. ALL WALL DUPLEX, TELEPHONE AND SWITCH BOXES ARE TO BE CAULKED AS PER BUILDING STANDARD. O DOOR NO. CONTRACTOR: TIN TIN, LLC. P-3 PLUMBING SCHEDULES & DETAILS OCCUPANCY: SEE CALCULATION P.O. BOX 370 9. CONTRACTOR SHALL BE RESPONSIBLE FOR ARRANGING WITH TENANT/OWNER REPRESENTATIVE FOR TOTAL: 32 McLEAN, VA 22101 E-1 ELECTRICAL SPECIFICATIONS PARKING REGULATIONS, LOADING REGULATIONS AND ROOF ACCESS AS WELL AS ALL SCHEDULING FOR �� BREAK LINE P. (703) 893-7233 E-2 ELECTRICAL PLANS ACCESS TO TENANTS SPACES. CONSTRUCTION TYPE: II B F. (703) 893-5267 E-3 ELECTRICAL SCHEDULES, DETAILS, & SYMBOLS 10. FOR INFORMATION ON COLUMNS, EXTERIOR WALLS, CORE AREA, ETC.: SEE BASE BUILDING BUILDING HEIGHT: 20 FEET ARCHITECTURAL DRAWINGS, SHELL AND CORE DRAWINGS. PARTITION TYPES - HIGH RISE: NO (1 FLOOR) TENANT: JL SALON 11. ALL WORK IS TO CONFORM WITH OWNER'S DRAWINGS AND SPECIFICATIONS. SEE SCHEDULE NO. OF STORIES IN ONE FLOOR 7245 EAST 146TH ST. SUITE 130 12. ALL CONTRACTORS ARE RESPONSIBLE FOR LAYING OUT EQUIPMENT RUNS TO INTERFERENCES. PROJECT: CARMEL, IN 46033 13. IF THE LIGHT FIXTURES OR OTHER ELEMENTS ON OR ABOVE THE CEILING CANNOT BE LOCATED AS PER PROPOSED PROJECT: 1,800 SF OCCU PANT LOAD THE PLANS, THIS MUST BE NOTED BEFORE BIDDING SO REVISIONS MAY BE MADE AND INCLUDED IN BIDS. TOTAL: 1,800 SF AREA OF WORK - 1,800 ft' 14. DOORS AND FRAMES WHICH REQUIRE A FIRE RESISTANT RATING SHALL BE A TYPE APPROVED BY THE NATIONAL BOARD OF FIRE UNDERWRITERS. CEILING: 12'-8" 15. AFTER THE JOB IS IN PROGRESS, "ADDENDUMS" OR "CHANGE ORDERS" MUST BE APPROVED IN WRITING SPRINKLER SYSTEM YES 1:100 BY THE OWNER AND/OR ARCHITECT. IN BLDG: BLDG FULLY 1,450.14 ft2/100 = 14.50 Occupants SPRINKLED 1:15 16. EXIT AND DIRECTIONAL SIGNS AND LIGHTS SHALL COMPLY WITH STATE AND LOCAL CODES. SEE MONITORED YES WAITING AREA REFLECTIVE CEILING PLANS. 168.88 ft' / 15 = 11.25 Occupants FLR UNDER 1ST FLOOR BREAK AREA 17. PERFORMANCE OF ALL WALL AIR HANDLING UNITS SHALL BE CHECKED AND ANY PROBLEMS SHALL BE CONSTRUCTION: 86.54 ft2 / 15 = 5.76 Occupants REPAIRED TO A LIKE NEW CONDITION. TOTAL = 32 OCCUPANTS 18. CONTRACTOR SHALL BE RESPONSIBLE FOR BRACING OF PARTITION WALLS AS REQUIRED AND AT ALL SITE PLAN/ FIRE &LIFE SAFETY DOOR OPENINGS. 19. DRYWALL CONTROL JOINTS SHALL BE PROVIDED IN ACORDANCE WITH RECOMMENDED PRACTICES OF THE UNITED STATES GYPSUM ASSOCIATION. 20. ALL MISCELLANEOUS BLOCKING IS TO BE FIRE -RETARDED. 21. CONTRACTOR TO REFINISH ALL FLOORS NOT RECEIVING NEW CARPET. 22. ALL ANGLES SHOWN ARE 45 DEGREES, UNLESS OTHERWISE NOTED. METE 00 107 r L 23. CONTRACTOR SHALL APPLY FOR AND OBTAIN ALL NECESSARY PERMITS. 124 SF _ Ea � W/D 24. CONTRACTOR MAY SUBSTITUTE MATERIALS AND/OR CONSTRUCTION UPON SUBMISSION TO AND APPROVAL BY THE ARCHITECT. 25. DIMENSIONS NOTED "HOLD" MAY NOT BE ADJUSTED WITHOUT APPROVAL BY THE ARCHITECT.`- 26. ISOLATE DISSIMILAR METALS IN CONTACT WITH EACH OTHER. UP 27. ALL DOORS, DOOR FRAMES, AND SHELVING SHALL BE FINISHED WITH SEMI -GLOSS ENAMEL. ALL OTHER SURFACES ARE TO BE FLAT PAINT UNLESS OTHERWISE NOTED. i TiMl l , 28. CONTRACTOR SHALL FURNISH AND INSTALL FIRE EXTINGUISHERS, FIRE DAMPERS, AND SMOKE DETECTORS AS REQUIRED BY THE FIRE MARSHALL AND LOCAL CODES. ❑ O) 29. CONTRACTOR SHALL COORDINATE INSTALLATION OF FIRE PULL BOXES, FIRE BELLS AND EXIT SIGNS, ETC. AS REQUIRED BY LOCAL CODES. - 30. CONTRACTOR SHALL SCHEDULE AND PERFORM ALL WORK SO AS NOT TO REASONABLY DISTURB ANY n TENANT IN THE BUILDING AND SHALL BE RESPONSIBLE FOR ANY OVERTIME COSTS INCURRED THEREBY. ❑_ 31. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND DISPOSAL OF ALL CONSTRUCTION DEBRIS AND N IC N I C REFUSE AND CLEANING OF ALL INTERIOR GLASS SURFACES. F-1 rl 32. UPON COMPLETION OF THE WORK, CONTRACTOR SHALL NOTIFY THE ARCHITECT TO COMPILE A PUNCH -LIST OF CORRECTIONS. 33. ALL EXISTING LIGHT FIXTURES ARE TO BE RE -USED - AS PER PLANS. 34. CONTRACTOR SHALL REPLACE ALL EXISTING EXIT EMERGENCY LIGHTS IN LOCATIONS AS SHOWN AFTER NEW CEILING AND NEW WALL FINISHES ARE INSTALLED. ti i 35. CONTRACTOR SHALL REPLACE AND RESTORE EXISTING FINISHES AND SURFACES AS AFFECTED BY NEW O) CONSTRUCTION. M 36. ELECTRICAL CONTRACTOR SHALL CIRCUIT RECEPTABLES TO AVAILABLE SPARES IN EXISTING PANEL BOX. 37. ELECTRICAL CONTRACTOR SHALL CAP OFF ALL UNUSED EXISTING WIRING. 38. CONTRACTOR TO PROVIDE LOCKABLE TENANT SPACE DURING NON -WORK HOURS.�rrrllrrr\///JJJ\\\\///))1 39. MAINTENANCE MATERIALS: DELIVER USABLE SCRAPS OF CARPET, UNUSED REMOVED DOORS AND ANY OTHER REUSABLE MATERIALS TO THE OWNER'S DESIGNATED STORAGE AREA. Ll RELEASED FOR CONSTRUCTION AREA OF ORK 't�Op Subject to compliance with all regulations ..a Q"i....d i..... i r..e... City of Camel �; Gs DATE: 03/25/19 Soe Lin & Associates LLC 4340 East West Highway Suite 105 Bethesda, Maryland 20814 USA 301.986-9300 Fax.986-0500 Notes Consultants Dwn By Chkd By Job No. Project NAIL SALON 7245 EAST146th ST SUITE 130 CARMEL, IN 46033 ZUMOT REAL ESTATE MGMT. Drawing Title COVER SHEET Sheet No. CS