HomeMy WebLinkAboutCS - COVER SHEETGENERAL NOTES
SYMBOLS
PROJECT
INFORMATION
PROJECT
DIRECTORY
INDEX
OF
DRAWINGS
1.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWING AT THE JOB SITE
AND SHALL NOTIFY THE ARCHITECT AND THE OWNER OF ANY DISCREPANCIES, OMISSIONS, AND/OR
L_ x� WALL SECTION NO.
PROJECT DESCRIPTION:
EXISTING RAW UNFINISHED SPACE.
OWNER: TIN TIN, LLC
ARCHITECTURAL DRAWINGS
CONFLICTS BEFORE PROCEEDING WITH THE JOB.
A�T- SHEET NO.
PROVIDE NEW WALLS, NEW
P.O. BOX 370
2.
DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. LARGE SCALE DETAILS GOVERN SMALL SCALE PLANS.
CEILING,
MCLEAN, VA 22101
(703) 893-7233
CS
COVER SHEETP.
F. (703) 893-5267
AT-1
OCCUPANCY DIAGRAM &NEW CONCRETE PLAN
3.
ALL WORK SHALL CONFORM TO STATE AND LOCAL BUILDING CODES, FIRE, HEALTH, WSSC, ETC.
SECTIONAL DETAIL NO.
�
AT-2
PROPOSED FLOOR PLAN
SHEET NO.
AT-4
PROPOSED RCP
4.
ALL PARTITIONS ARE DIMENSIONED TO OUTSIDE SURFACE, UNLESS OTHERWISE NOTED U.O.N.)
(
PROJECT LOCATION:
7245 EAST 146TH ST.
AT-4
PROPOSED POWER AND FINISH PLANS
SUITE 130
ARCHITECT: SOE LIN AND ASSOCIATES, LLC
AT-5
ELEVATIONS AND SECTIONS
5.
CONTRACTOR SHALL BE RESPONSIBLE FOR THE BRACING AND BLOCKING OF WALLS RECEIVING
x DETAIL TARGET, ENLARGEMENT
CARMEL, IN 46033
4340 EAST WEST HIGHWAY
MILLWORK, SHELVING, ETC.
- SHEET NO.
SUITE 105
BETMD 20814
6.
WHERE A VINYL BASE IS SPECIFIED, SETABOVE CARPET.
CODES:
IBC 2012
P. (301) 1) 98686-9300
MEP DRAWINGS
7.
ALL FLOORS SHALL BE LEVELED AND FREE OF IRREGULARITIES TO ASSURE ONE CONSTANT FLOOR
A
AAAAAA INTERIOR ELEVATION SYMBOL
NFPA 13-2010
IMC 2012
F. (301) 986-0500
MIA
HVAC SPECIFICATIONS
HEIGHT SO THAT DOOR BUCKS, WHEN SET, ARE AT CONSISTENT DIMENSIONS FROM THE CEILING, WITH
DDRAWING NO.
IPC 2006
MpE THE ENGINEERING COLLABORATION
M-2
HVAC FLOOR PLAN
NO GAPS BETWEEN THE BOTTOM OF THE DOOR BUCK AT THE SLAB AFTER CARPETING AND OTHER
SHEET NO.
NEC 2008
ENGINEERS: EXECUTIVE DRIVE
M-3
HVAC DETAILS
FLOOR FINISHES ARE INSTALLED. ANY UNAVOIDABLE CHANGES IN THE FLOOR HEIGHT SHALL BE
CABO/ANSI
SUIT
SUITE 100
M-4
HVAC GENERAL NOTES
GRADUALLY RAISED AND TROWELED TO CREATE A RAMP -LIKE EFFECT. ALL DEPRESSIONS, CRACKS,
A117.1-2009
INDIANAPOLIS, IN 46241
MEP-1
MEP UNDERGROUND PLAN
SCREEDS, AND EXPANSION JOINTS ARE TO BE FILLED WITH A GOOD GRADE NON -CRUMBLING LATEX BASE
1xx AREA DESIGNATION/
FLASHING COMPOUND, WATER PUTTY OR CRACK FILLER.
ROOM NUMBER
USE GROUP / BUILDING
B-BUSINESS
P. (317) 636-3941
P-1
PLUMBING SPECIFICATIONS
OCCUPANCYGROUP:
P-2
PLUMBING PLAN
8.
ALL WALL DUPLEX, TELEPHONE AND SWITCH BOXES ARE TO BE CAULKED AS PER BUILDING STANDARD.
O DOOR NO.
CONTRACTOR: TIN TIN, LLC.
P-3
PLUMBING SCHEDULES & DETAILS
OCCUPANCY:
SEE CALCULATION
P.O. BOX 370
9.
CONTRACTOR SHALL BE RESPONSIBLE FOR ARRANGING WITH TENANT/OWNER REPRESENTATIVE FOR
TOTAL:
32
McLEAN, VA 22101
E-1
ELECTRICAL SPECIFICATIONS
PARKING REGULATIONS, LOADING REGULATIONS AND ROOF ACCESS AS WELL AS ALL SCHEDULING FOR
�� BREAK LINE
P. (703) 893-7233
E-2
ELECTRICAL PLANS
ACCESS TO TENANTS SPACES.
CONSTRUCTION TYPE:
II B
F. (703) 893-5267
E-3
ELECTRICAL SCHEDULES, DETAILS, & SYMBOLS
10.
FOR INFORMATION ON COLUMNS, EXTERIOR WALLS, CORE AREA, ETC.: SEE BASE BUILDING
BUILDING HEIGHT:
20 FEET
ARCHITECTURAL DRAWINGS, SHELL AND CORE DRAWINGS.
PARTITION TYPES -
HIGH RISE:
NO (1 FLOOR)
TENANT: JL SALON
11.
ALL WORK IS TO CONFORM WITH OWNER'S DRAWINGS AND SPECIFICATIONS.
SEE SCHEDULE
NO. OF STORIES IN
ONE FLOOR
7245 EAST 146TH ST.
SUITE 130
12.
ALL CONTRACTORS ARE RESPONSIBLE FOR LAYING OUT EQUIPMENT RUNS TO INTERFERENCES.
PROJECT:
CARMEL, IN 46033
13.
IF THE LIGHT FIXTURES OR OTHER ELEMENTS ON OR ABOVE THE CEILING CANNOT BE LOCATED AS PER
PROPOSED PROJECT:
1,800 SF
OCCU PANT LOAD
THE PLANS, THIS MUST BE NOTED BEFORE BIDDING SO REVISIONS MAY BE MADE AND INCLUDED IN BIDS.
TOTAL:
1,800 SF
AREA OF WORK - 1,800 ft'
14. DOORS AND FRAMES WHICH REQUIRE A FIRE RESISTANT RATING SHALL BE A TYPE APPROVED BY THE
NATIONAL BOARD OF FIRE UNDERWRITERS.
CEILING:
12'-8"
15.
AFTER THE JOB IS IN PROGRESS, "ADDENDUMS" OR "CHANGE ORDERS" MUST BE APPROVED IN WRITING
SPRINKLER SYSTEM
YES
1:100
BY THE OWNER AND/OR ARCHITECT.
IN BLDG:
BLDG FULLY
1,450.14 ft2/100 =
14.50 Occupants
SPRINKLED
1:15
16.
EXIT AND DIRECTIONAL SIGNS AND LIGHTS SHALL COMPLY WITH STATE AND LOCAL CODES. SEE
MONITORED
YES
WAITING AREA
REFLECTIVE CEILING PLANS.
168.88 ft' / 15 =
11.25 Occupants
FLR UNDER
1ST FLOOR
BREAK AREA
17.
PERFORMANCE OF ALL WALL AIR HANDLING UNITS SHALL BE CHECKED AND ANY PROBLEMS SHALL BE
CONSTRUCTION:
86.54 ft2 / 15 =
5.76 Occupants
REPAIRED TO A LIKE NEW CONDITION.
TOTAL =
32 OCCUPANTS
18.
CONTRACTOR SHALL BE RESPONSIBLE FOR BRACING OF PARTITION WALLS AS REQUIRED AND AT ALL
SITE PLAN/ FIRE &LIFE SAFETY
DOOR OPENINGS.
19.
DRYWALL CONTROL JOINTS SHALL BE PROVIDED IN ACORDANCE WITH RECOMMENDED PRACTICES OF
THE UNITED STATES GYPSUM ASSOCIATION.
20.
ALL MISCELLANEOUS BLOCKING IS TO BE FIRE -RETARDED.
21.
CONTRACTOR TO REFINISH ALL FLOORS NOT RECEIVING NEW CARPET.
22.
ALL ANGLES SHOWN ARE 45 DEGREES, UNLESS OTHERWISE NOTED.
METE 00
107
r
L
23.
CONTRACTOR SHALL APPLY FOR AND OBTAIN ALL NECESSARY PERMITS.
124 SF _
Ea
�
W/D
24.
CONTRACTOR MAY SUBSTITUTE MATERIALS AND/OR CONSTRUCTION UPON SUBMISSION TO AND
APPROVAL BY THE ARCHITECT.
25.
DIMENSIONS NOTED "HOLD" MAY NOT BE ADJUSTED WITHOUT APPROVAL BY THE ARCHITECT.`-
26.
ISOLATE DISSIMILAR METALS IN CONTACT WITH EACH OTHER.
UP
27.
ALL DOORS, DOOR FRAMES, AND SHELVING SHALL BE FINISHED WITH SEMI -GLOSS ENAMEL. ALL OTHER
SURFACES ARE TO BE FLAT PAINT UNLESS OTHERWISE NOTED.
i TiMl
l
,
28.
CONTRACTOR SHALL FURNISH AND INSTALL FIRE EXTINGUISHERS, FIRE DAMPERS, AND SMOKE
DETECTORS AS REQUIRED BY THE FIRE MARSHALL AND LOCAL CODES.
❑
O)
29.
CONTRACTOR SHALL COORDINATE INSTALLATION OF FIRE PULL BOXES, FIRE BELLS AND EXIT SIGNS, ETC.
AS REQUIRED BY LOCAL CODES.
-
30.
CONTRACTOR SHALL SCHEDULE AND PERFORM ALL WORK SO AS NOT TO REASONABLY DISTURB ANY
n
TENANT IN THE BUILDING AND SHALL BE RESPONSIBLE FOR ANY OVERTIME COSTS INCURRED THEREBY.
❑_
31.
CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND DISPOSAL OF ALL CONSTRUCTION DEBRIS AND
N IC
N I C
REFUSE AND CLEANING OF ALL INTERIOR GLASS SURFACES.
F-1
rl
32.
UPON COMPLETION OF THE WORK, CONTRACTOR SHALL NOTIFY THE ARCHITECT TO COMPILE A
PUNCH -LIST OF CORRECTIONS.
33.
ALL EXISTING LIGHT FIXTURES ARE TO BE RE -USED - AS PER PLANS.
34.
CONTRACTOR SHALL REPLACE ALL EXISTING EXIT EMERGENCY LIGHTS IN LOCATIONS AS SHOWN AFTER
NEW CEILING AND NEW WALL FINISHES ARE INSTALLED.
ti
i
35.
CONTRACTOR SHALL REPLACE AND RESTORE EXISTING FINISHES AND SURFACES AS AFFECTED BY NEW
O)
CONSTRUCTION.
M
36.
ELECTRICAL CONTRACTOR SHALL CIRCUIT RECEPTABLES TO AVAILABLE SPARES IN EXISTING PANEL BOX.
37.
ELECTRICAL CONTRACTOR SHALL CAP OFF ALL UNUSED EXISTING WIRING.
38.
CONTRACTOR TO PROVIDE LOCKABLE TENANT SPACE DURING NON -WORK HOURS.�rrrllrrr\///JJJ\\\\///))1
39.
MAINTENANCE MATERIALS: DELIVER USABLE SCRAPS OF CARPET, UNUSED REMOVED DOORS AND ANY
OTHER REUSABLE MATERIALS TO THE OWNER'S DESIGNATED STORAGE AREA.
Ll
RELEASED FOR CONSTRUCTION
AREA OF ORK
't�Op
Subject to compliance with all regulations
..a Q"i....d i..... i r..e...
City of Camel
�; Gs
DATE: 03/25/19
Soe Lin & Associates LLC
4340 East West Highway
Suite 105
Bethesda, Maryland
20814 USA
301.986-9300
Fax.986-0500
Notes Consultants
Dwn By
Chkd By
Job No.
Project
NAIL SALON
7245 EAST146th ST
SUITE 130
CARMEL, IN 46033
ZUMOT REAL ESTATE MGMT.
Drawing Title
COVER SHEET
Sheet No.
CS