HomeMy WebLinkAboutE-3 ELEC SCHEDULES, DETAILS, AND SYMBOLSElectrical Symbols Legend Lighting Q LED disc Iighliplure provided by owner, installed by E.C. per requirements. ® N2 LED troffer l ighl p 2 lamp wal l l ight fixture provitletl by owner, installed by E.C. per requirements. 1 lamp pendant fixture provided by owner, installed by E.C. per requirements. ® 13 lamp pendant fixture provided by owner, installed by E.C. per requirements. ® Ceiling mounted exit sign "O Wall mounted exit sign Switches $ Single pole switch $3 Three-way switch Dimmer switch $I Timer switch CP Disconnect switch Power 8 Duplex receptacle (20 Amp rated) F Quad receptacle (20 Amp rated per duplex) Ground fault interrupt duplex receptacle (20 Amp rated) 8wP Weatherproof, ground fault interrupt duplex receptacle (20 Amp rated) with "While-In-Use"cover around fault interrupt Wad receptacle (20 Amp rated per tluplex) ® Special purpose receptacle as noted on drawings o Existing 1201 panelboand to remain QMotor connection Communication e Telephonedata outlet location, 1" concert with pullwim to above accessible ceiling Circuiting Conduit system concealed above ceiling Surface mounted call system - - - Conduit system under floor Hamadan. Conduit system to panel as noted on drawings Q Junction box Cf- Conduit up Conduit down 0- Notes 1. Switches shall be a maximum +48" A.F.F. to the top of the device unless otherwise noted on plans. 2. Receptacles, telephone outlets, and television outlets shall be a minimum of+18" A.F.F. rather bottom of the device unless otherwise noted on plans. 3. Not all symbols listed above are shown on plans. The symbol legend is used for reference of symbols shown on plans. See specifications for information related to symbols. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Corks City of Camel �V�I��V'�6*14aWMt_ DATE: \ 03/25/19 AL1-1,3,5 Panel designation Ground conclusions) (if used) Phase conductons) Neutral conductors) Switch leg or Go-between All conductors 012 AWG otherwise noted All conduit N*'unless otherwise noted Circuit No. designation Notes 1. #12 AWG is min. conductor size except as noted. 2. W4" conduit is min. Size except as capacity ascribing 24 volt control conductors and switchlegs may be in 1/2" size, others as noted. 3. 1/2" is min. Flexsteel, Greenfield and Sealite size. Seale: None Light Fixture Schedule Illustration Type Manufacturer Model No. Lamp Type Voltage Mounting Description (See Note 1) Notes Columbia LCATM-35MLG-EDU 2'x2'LED volumeldblroHer. Acrylic, prismatic cater Lthonia diffuser. 0 10V dimmable. Suitable ton damp locations. IC Metalux rated. 'C1' Mercury LED /3500K 120 Ceiling $5 Recessed Moment Williams Day Bids Notes: 1. Pictures are shown as a visual wall and may not depict specific attributes listedin this schedule. 2. Ememencvbackuo: minimum of 90 minute rolfime for emergency operation. 3. 0-1011LEDonermingdaver. Provide Manufacturer approved compafible dimmer where applicable (refer 0 Nghfir)g plans for dimmer bcafioril 4. Coordinate with cabinetry structure prior to rough- in and verity exact quantities ofaN system components prior to ordering. 5. Coordinate with ceiling and/or wall structure prior to rough in and adjust as necessary to avoid installation conflicts. Notes: Main: Main Lug Only tt *= GFCl circuit breaker Existing Tenant Panel NStt Bus: Existing Mounting: Recessed **=HACR circuit breaker Location: Back of suite Cr. No. 20 AMP 1 Pole u.0 N. Cis. No. <Load(KW)> Remarks Liq F' Hee Equip- Other Other Equip- A/C Heat Rec. Light Lighting Front Room 1.1 1 30 60 2 .7 Lighting Back Receptacles Front .8 3 4 .8 Power Tables Power Tables .8 5 e .8 Power Chairs Power Chairs .8 ] 8 .8 Power Chairs Power Chairs .8 9 10 .8 Power Chairs Power Chairs .8 11 12 .4 Receptacle Receptacles .4 13 14 .3 Receptacle RR Receptacle RR .3 15 15 .7 Refrigerator At Receptacle Countertop .3 17 18 .3 HVAC Receptacle Quad Rec 1.0 19 20 1.0 Quad Rec Front Wall Seances .8 21 22 .8 Front Pendants Track Lighting .8 23 24 .8 Window Receptacles Spare 25 26 Spare Spare 27 28 Spare Spare 29 30 smile Space 31 32 Space Space 33 34 Space EF-1 1 .6 35 35 Space * Washer 1.0 37 38 14.8 RTU-1 ** D ryer 45 39 40 41 42 2.7 6.0 - - 6.1 - Connected load (KW) - - 14.8 - 6.7 1 1.5 2.7 6.0 - - 6.1 - Demand load (KAd - - 14.8 - 6.7 1 1.5 Legend Total Demand(KWI Feeder Calculated = 1 Pole 2 Pole = 3 Pole Light Rae I Heal I A Equip. Other Total Fed From. Existing (bottom) Wire Size Existing Conduit: Existing Total Demand Amps = 105± M 4.2 12.7 1d.8 6.1 - 37.8 Soe Lin & Associates, LLC 4340 East West Highway Suite 105 Bethesda, Maryland 20814 USA 301.986-9300 Fax.986-0500 Notes Consultants own By ALB Chkd By SLH Job No. 18122 Project NAIL SALON 7245 EAST146th St CARMEL, IN 46033 ZUMCIT REAL ESTATE MGMT. Drawing Title ELEC.SCHEDULES, DETAILS, & SYMBOLS �eras"�jEL L.n'moyti � yrSpSt�yG1S'IFA �Rpc � _* PE10100876 *3 ���'x'� �✓pANP ��` Sheet No. E-3