HomeMy WebLinkAboutM-3 HVAC DETAILSE— W re support attached to structure 1" Black rigid �insulation board 12" all Washer with 8" 4 sides black neoprene min. paid on untlersitle Ceiling Eggcrae type return grille 7 Concrete floc slab D 3 Open Plenum Return Grille p M-3 Scale: None O d p Exhaust fan housing Granular fill J Prefabricated curb with built-in cant. Offset for 30° or less roof insulation thickness f More than 30° Vapor barrier Compacted Ductoffset Duct offset 12' min. Curb insulation sand backfill Use radius for more than 30° Use mitoretl far 30° or less Backtlraft damper Roof PVC coated Round air — r duct by M.C. See —III—III—I specifications. Trench Turning vanes and backfill by M.C. Secure and seal ductwork to angle frame all around NOTES: 2H V.D. OH q\ hed 1. Underground must be proteathru u from tlamageduringoof of construction for tfi andaf floor is pouretl. M.C. shall provitlea tlhru ductwork video pool of no damage prior to and after ` Ductwork. See plans for continuation. concrete floor Is poured. 2. Fill or concrete must not be directly poured onto the tluclwork �45°Boottap fitting 3. Ducts must be restrained during fill to prevent floating. 4. No vehicular traffic is allowed war the ductwork before, during, or after fill. 900 Square Elbow 90° Ratliusetl Elbow Branch off main Note: Roof opening shall conformto manufacturer's curb size. D 2 Low Velocity Sheet Metal Fittings M-3 Scale: None D Downblast Roof Exhaust Fan with Curb (il underground Ductwork with Sand Backfill M-3 Scale: None M-3 Scale: None Insulated flexible duct !Provide shoe 6" Min. to supply diffuser Low press / tap fitting supply brannchch dud cl V./ 4" flexible duct connection between roof ooftop Unit Neoprene wea^bRoof II insulation and bottom of rooftop unit Curb by RTU MF II specified oWood nailer E� Refer to "Gooseneck Detail" CounleFielof applietl cant strip 1U Collar with manual J T Supply dffuserJ volume damper &lock Insulated flexible duel upply and to supply diffuser return Roof Refer to Application NOT Acceptable construction. Treated 2shimmingq\\ architectural tlrawngs for type Notes: Hood exhaust duct to leve`Roof structure. Refer to si drawings for type ovide a 45 degree entry square -to -round firing from low pressure Provide supply branch duct when the supply diffuser branch size equals or Storm collar Full perimeter curb supports exceeds the depth of the supply branch dud. Width shall equal round diffuser branch size, depth shall equal supply branch duct depth. 3'-P' min Secure flexible duct to Provide rectangular 90° Refer to supply diffuser plenum connection detail H guidelines of his supply diffuser elbow Tall cone sheet metal flashing w/flange elbow to transition to been can not be met due to physical limitations. lifting with drawband Treated 2x4 blockinghorizontal. Roof construction. Refer to arohitecW21 drawings for type. Do not provide a duct plenum and horizontal tap If 90° elbow A maximum length of 5'-0" of flexible dud is allowed in a single run. _J - is impractical, coordinate 1 alternative with Engineer Sheet metal elbow Sheet metal box Secure flexible dud to supply diffuser elbow — Roof structure. Refer to structural 1 \` Notes: firing vnIn drawband 1-12" bull 1-12"tluct wrap Support plate drawings for type. 1. Roof curbs shall be with properly levelingdevices fmaich l and the so equipment is level and the roof curb is installetl to match the roof slope. installed the �— Refer to HVAC drawings 2. Provide perimeter angle support at all sides between structural steel. Size of angle based on load of equipment. Minimum size shall be 3" x 3" x 1 X'. } R\ Lay -in panel for exhaust duct size. 3. Roof curbs shall not be supported by the roof insulation. "2 " x 12' diffuser where required Ceiling Ceiling J 24" x 24" tliffuser tII 4. Coordinate location of roof curb and roof opening with structure. II�V �J 5. Roofing insulation shall be continuous under the rooftop equipment. D 6 Exhaust Gooseneck M_3 Scale: None D 4 Roof Equipment Support Curb Section ScaleNone M-3 : , D Supply Diffuser and Flexible Duct Connection M-3 Scale: None RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 03/25/19 r LAB0R9 l'r $v G Air - w w - 41 Soe Lin & Associates, LLC 4340 East West Highway Suite 105 Bethesda, Maryland 20814 USA 301.986-9300 Fax.986-0500 Notes Consultants Dwn By AK Chkd By JTL Job No. 18122 Project NAIL SALON 7245 EAST146th St CARMEL, IN 46033 ZUMOT REAL ESTATE MGMT. Drawing Title HVAC DETAILS a L L.,. �°u+µ \ yrSpSlVyC>75'IFA �Rpc � 13 No. _* PE10100876 "� STNIE OF �% Sheet No. M-3