HomeMy WebLinkAboutA121 Electrical Plan - Reflected Ceiling PlanELECTRICAL LEGEND NEW CONSTRUCTION DO POWER OUTLET, DUPLEX POWER CUTLET, QUADRUPLEX JUNCTION BOX MOUNTED OCEILING JUNCTION BOX ® BOX, BLANK COVER PLATE ® BOX, OPEN P PROVIDE JUNCTION BOX � ABOVE CEILING FOR POWER POLE CONNECTION. POWER POLE BY OTHERS. FLOOR BOX WITH POWER FO=19 AND DATA, FLUSH MOUNTED FLOOR BOX WITH ® JUNCTION BOX AND DATA, FLUSH MOUNTED DATA/COMMUNICATION 14 OUTLET (PROVIDE BOX AND PULLSTRING ONLY) DED DEDICATED CIRCUIT GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET +42" HEIGHT OF ELECTRICAL OR DATA DEVICE EXISTING TO REMAIN POWER OUTLET, DUPLEX POWER OUTLET, QUADRUPLEX J 0 JUNCTION BOX CEILING MOUNTED JUNCTION BOX ® BOX, BLANK COVER PLATE QO BOX, OPEN P POWER AND DATA POLE FLOOR BOX WITH POWER ® AND DATA, FLUSH MOUNTED FLOOR BOX WITH 107< JUNCTION BOX AND DATA, FLUSH MOUNTED b DATA/COMMUNICATION OUTLET `LIT,_ E07 _ JE02 N+44" E02 zz STORAGE ® z OPEN AREA N COATS 41 r91 ENTRY ILA �/ ® P1 _ E01 ` I6= N JUI >CUS FOCUS (^1 r® i ® AREA NOT IN CONTRACT RELEASED FDR CDNSTRUCTIDN Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 03/27/19 GENERAL ELEC. NOTES I. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL NEW DEVICES AND FACE PLATES TO MATCH EXISTING. RELOCATE EXISTING OUTLETS AT SAME HEIGHT AS NEW IF THERE IS A VARIANCE. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. ALL ELECTRICAL AND MAGNETIC HARDWARE AND CONNECTIONS TO BE COMPLETED BY TENANT'S SECURITY VENDOR. 4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING, ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. ELECTRICAL PLAN NOTES ED7 PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE DETAILS, E02 PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT LOCATION WITH TENANT. E03 COORDINATE OUTLET HEIGHTS WITH HEIGHT OF RELOCATED BAR TOP. DESIGN INTENT IS FOR OUTLETS TO BE AT SIMILAR HEIGHT AND ORIENTATION AS EXISTING; VERIFY IN FIELD. E04 IS POSSIBLE, CONVERT EXISTING BLANK RECEPTACLE TO NEW DATA. IF NOT POSSIBLE, REMOVE BLANK AND PROVIDE NEW DATA IN SAME LOCATION. E05 PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR ELECTRICAL AND DATA, COORDINATE WITH TENANTS FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING. E08 EXISTING FLOOR CORE TO REMAIN IF LOCATION IS ACCEPTABLE FOR TENANT'S FURNITURE LAYOUT; CONFIRM WITH TENANT, IF NOT ACCEPTABLE, REMOVE EXISTING FLOOR CORE AND INFILL AS REQUIRED TO MAINTAIN BUILDING CONSTRUCTION TYPE, PREPARE FLOOR FOR NEW FINISHES AS REQUIRED. 0IS POSSIBLE, CONVERT EXISTING BLANK RECEPTACLE TO NEW 0 DUPLEX. IF NOT POSSIBLE, REMOVE BLANK AND PROVIDE NEW DUPLEX IN SAME LOCATION. E08 EPSON PROJECTOR SYSTEM FROM 5TH FLOOR TO BE RELOCATED TO THIS AREA. PROVIDE POWER IN CEILING; COORDINATE EXACT REQUIREMENTS AND LOCATION WITH TENANT. 1�� `ST EO iN+66" ED5 1+66" 1N /_ 1 11 Y CONFERENCE ELECTRICAL PLAN 0 24' 8' 16: RCP LEGEND NEW OR RELOCATED LIGHT FIXTURE, 2'x4', FLUORESCENT, PARABOUC ❑LIGHT FIXTURE, 2X2', FwoREscENr. PARABOLIC O LIGHT FIXTURE, 1 M, FLUORESCENT, PARABOLIC $( RECESSED LIGHT FIXTURE DIRECTIONAL RECESSED LIGHT FIXTURE WALL SCONCE UGHT MIXTURE LIGHT FIXTURE. ® PENDANT, SALVAGED FROM DEMOLITION ®A LIGHT FIXTURE, PENDANT, SALVAGED FROM DEMOMON NL INDICATES NIGHT UGHF LOCATION ® EXIT LIGHT FIXTURE EMERGENCYLIGHT FIXTURE $N LIGHT SWITCH INS LIGHT SWITCH, SWAY $ND LIGHT SWITCH, DIMMER $NP SWITCH, PROJECTOR SCREEN $NG SWITCH, GARBAGE DISPOSAL i — LIGHTCIRCUIT EXISTING TO REMAIN LIGHT FIXTURE, 2'x4', FLUORESCENT, PARABOLIC ®UGHT FIXTURE, 2'x2', FLUORESCENT. PARABOLIC O UGHT FIXTURE, 1'X4', FLUORESCENT, PARABOLIC )X RECESSED UGHT FIXTURE WALL SCONCE LIGHT FIXTURE ® UGHTFIXTURE, PENDANT INDICATES NIGHT LIGHT LOCATION ® EXIT LIGHT FIXTURE EMERGENCY LIGHT FIXTURE $ LIGHT SWITCH $3 LIGHT SWITCH, SWAY $D LIGHT SWITCH, DIMMER $P SWITCH, PROJECTOR SCREEN $G SWITCH, GARBAGE DISPOSAL -- UGHTCIRCUIT CEILING GRID, _i CEILING GRID, SUSPENDED, 2'x2' - __T__I _ SUSPENDED, 2'x2' ❑ EXPOSED TO DECK ❑ GYPSUM BOARD CEILING EXSIING/RELOCATED ® DIFFUSER. LAYJN. Tx2' DIFFUSER, LAY -IN, 2'X2 EXISTING/RELOCATED ® DIFFUSER, LAY -IN, 1'X4' [I DIFFUSER, LAYJN, 1'X4' EXISTING/RELOCATED ® DIFFUSER, LAY IN, 4N4' m DIFFUSER, LAYJN, 4k4' NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. RELOCATE DIFFUSERS & MECHANICAL DIFFUSER RELOCATION GENERAL RCP NOTES I. PROVIDE NEW BUILDING STANDARD CEILING GRID AN D TILE AT 7''-9" ALL WHERE SHOWN ON PLAN. 2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90, 1, CONTRACTOR MUST NOTIFY SDI, 4. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. OVER 50%OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 5. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTISWITCHPLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 0 cc 3 MECHANICAL NOTES I_ MECHANICAL WORK IS LIMITED TO A DESIGN- BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS, NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENTARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. RCP PLAN NOTES CONTROL ENTRY 401, BREAK 406, & OPEN AREA 404 LIGHTING R01 WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED AND REMOVE ANY UNUSED SWITCHES (WHERE APPLICABLE). R02 REMOVE AS MUCH OF THE EXPOSED CONDUIT, PIPING, JUNCTION BOXES AND MISCELLANEOUS UNUSED EQUIPMENT AS POSSIBLE. REPAIR THE EXISTING DUCT INSULATION WRAP SUCH THAT NO TORN OR DAMAGED INSULATION IS VISIBLE (IF APPLICABLE.) CLEAN AND PREPARE FOR DRYFALL PAINT. AS SPECIFIED, PAINT EXISTING EXPOSED CEILING DECK, EXPOSED DUCTWORK, SPRINKLER PIPING, JUNCTION BOXES, CONDUIT, STRUCTURAL BEAMS AND FIREPROOFING IN ACCORDANCE WITH NFPA 13 6.3.8. EXTEND PAINT PAST BULKHEAD AS FAR BACK AS REQUIRED SUCH THAT ALL VISIBLE DECK AND COMPONENTS FROM EYE -LEVEL AT ANY POINT IN THE SPACE IS FINISHED WITH DRYFALL PAINT (PT_.) REFERENCE SHEET A 131 FOR FURTHER DETAIL. R03 EXISTING DRYWALL BULKHEAD TO REMAIN AND BE REPAINTED Pr_. INSTALL FLOATING CLOUD AT 8'-0" AFF W ITH 2'X2' BU LD I NG 4 STANDARD CEILING GRID/TILE AND ARMSTRONG AXIOM TRIM TO MATCH TENANT'S SPACE ON 5TH FLOOR. LOCATE FLEX DUCT TO NEW DIFFUSERS SUCH THAT THEY ARE NOT VISIBLE FROM GROUND LEVEL. NOTE THAT SPRINKLERS MAYBE REQUIRED ABOVE AND BELOW CLOUD, FIRE SPRINKLER CONTRACTOR TO PROVIDE SUBMITTAL OF FINAL LAY -OUT FOR FINAL APPROVAL PRIOR TO INSTALLATION. PROVIDE NEW DRYWALL BULKHEAD AS SHOWN, BOTTOM OF ROS BULKHEAD TO BE AT 8'-0" AFF. ENTIRE BULKHEAD TO BE PAINTED PT_, RO ® ® ®EL Eel — �I J II II I ® AREA NOT IN CONTRACT REFLECTED CEILING PLAN IN 0 2' 4' B' 16'il ❑ AREA OF WORK %m v G r O C O � O N V +_ n �n Z� - e =tea O n O w O M o C G 33 'vVw] THIS DRAWING, AND THE IDEAS. DESIGNS AND CONCEPTS CONTAINED HEREIN. ARE WE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN. INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 04 O 0 W� J W W- uSJ � aaaaaJ � L N VU U LU w F- C/) Q aaaaaa� II� Q � VVoQ L a 7- SSUE DATE DESCRIPTION 02.21.19 REVIEW SET REVISIONS ARK DATE DB DESCRIPTION PROJECT NUMBER 2019.008 PROD. MGR DRAWN BY AS SLF 4TH FLOOR ELECTRICAL PLAN/ REFLECTED CEILING PLAN A121