HomeMy WebLinkAboutT111 Cover Sheet & General NotesMECHANICAL & ELECTRICAL NOTES GENERAL PROJECT NOTES I. THE MECHANICAL, ELECTRICAL AND PLUMBING SCOPES OF WORK ARE LIMITED TO I. ALL WORKS HALL COMPLY WITH THE REQU I REMENTS OF THE EXISTING BU I LD I NG BASIC DESIGN -BUILD ALTERATIONS WHICH ARE OUTLINED IN THESE PLANS. THE CONSTRUCTION TYPE AS DEFINED BY SECTION 601 OF THE INDIANA BUILDING DESIGN -BUILD CONTRACTORS FOR EACH TRADE MUST NOTIFY THE ARCHITECT IF THEY CODE. FIND THAT THE SCOPE OF WORK EXCEEDS THE LEVEL OF MECHANICAL, ELECTRICAL OR PLUMBING WORK INDICATED ON THESE DRAWINGS SO THAT ANY NECESSARY 2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE ENGINEERING CAN OCCUR AND ADDITIONAL PLANS CAN BE FILED, OR IF AND LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR ADDITIONAL INFORMATION IS NEEDED IN ORDER TO DO THE WORK IN THE FIELD. THE VERIFYING THE CURRENT APPLICABLE BUILDING CODE(S)FORTNEIR MECHANICAL, ELECTRICAL AND PLUMBING DESIGN -BUILD CONTRACTORS SHALL RESPECTIVE SCOPE OF WORK. COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM SYSTEMS SHALL BE INSTALLED BY THE APPROPRIATE 3. CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE DESIGN -BUILD CONTRACTOR AND MUST COMPLY WITH ALL APPLICABLE STATE AND DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM DESIGN -BUILD CONDITIONS OR NEW WORK REQUIREMENTS. CONTRACTORS( SHALL MAKE CONTRACTORS ARE RESPONSIBLE FOR COMPLETING AND FILING THE R PLANS AND THEMSELVES FAMILIAR WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY OBTAINING iH El PERMITS. AWARE OF THE REQUIREMENTS OF THE SCOPE OF WORK. 2. MECHANICAL WORK 15 LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE 4. FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. I GENERAL DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE NG CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTIONNIFIF EXISTING BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS CONDITIONS PREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT SCALE DRAWINGS. NOTED DIMENSIONS TAKE PRECEDENCE. IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND 5. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE ANY DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO SCHOTT CODES. DESIGN, INC. 3. VERIFY HEAT LOADS OF ANY SPECIAL EQUIPMENT IN THE TENANT SPACE, AND 6. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER PROVIDE ADDITIONAL AIR FLOW IF REQUIRED, CONFIRM WITH OWNER PRIOR SO ANY REGARDING ALL ON -SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK PURCHASE OF NEW EQUIPMENT. REVISE ZONING IF REQUIRED. DO NOT DESIGN ANY SCHEDULE, MATERIALS STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE SINGLE OFFICE SPACE TO BE ON A SPLIT ZONE UNLESS APPROVED BY BUILDING WORK SITE, TRAFFIC CONTROL, AND BUILDING/PUBLIC SAFETY PROCEDURES OWNER/LANDLORD. DURING CONSTRUCTION, THE CONTRACTOR SHALL ALSO COORDINATE WORK "BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS NECESSARY SO EXECUTE 4. RELOCATE AIR -SUPPLY DIFFUSERS AND RETURN -AIR GRILLES AS REQUIRED. PROVIDE THE OVERALL PROJECT SCOPE. PROPER Al R SUPPLY FOR DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES. LOCATION OF DIFFUSERS SHOWN ON PLAN IS FOR REFERENCE ONLY. CONTRACTOR 7, THE GEN FRAIL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY IS TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS REQUIRED BY WORKING HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR CODE. TO AND DURING HOLIDAYS. LANDLORD RESERVES THE RIGHT TO RESTRICT CONSTRUCTION SO NIGHTS AND WEEKENDS WHEN THAT CONSTRUCTION IS 5. POSITION LOCATION OF ALL THERMOSTATS WHERE APPROPRIATE PER MECHANICAL DEEMED TO INTERFERE WITH THE OPERATIONS OF ADJACENT TENANTS. DESIGN. COORDINATE WITH TENANT AND BUILDING OWNER FOR FURNITURE PANEL OR OTHER CONFLICTS. PROVIDE BALANCE REPORTS TO OWNER UPON COMPLETION B. FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR OF PROJECT. SHALL COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO THE OWNER, TENANT, AND SCHOTT DESIGN WHEN 6. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DECISIONS MUST BE RENDERED IN ORDER FOR THE CONTRACTOR TO MEET THE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF PROJECT SCHEDULE. THE OWNER,TENANT, OR DESIGNER/ARCHITECT IS NOT ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF RESPONSIBLE FOR DELAYS RESULTING FROM THE CONTRACTOR'S FAILURE TO THE EXISTING ELECTRICAL SERVICE IN THE BUILDING, ELECTRICAL CONTRACTOR IS SO COMMUNICATE MATERIAL LEAD TIMES. NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES, 9. SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR 7. COMPLY WITH THE I NDIANA ELECTRICAL AND MECHANICAL CODE AND ALL OTHER SUBSTITUTIONS WITH APPROPRIATE SUPPORT INFORMATION SO THE DESIGNER. APPLICABLE CODES. ALLOW REASONABLY SUFFICIENT TIME FOR THE DESIGNER SO REVIEW THE REQUEST AND RENDER A DECISION. 8. SIZE AND CIRCUIT ELECTRICAL POWER ITEMS. PROVIDE OR REUSE ELECTRICAL POWER AND DATA OUTLETS AS REQUIRED. 10. DESIGN, INC.,SHALL HOT HAVE CONTROL OVER, ORBE IN CHARGE OF, AND SHALL NOT BE RESPONSIBLE FORA CONTRACTOR'S CONSTRUCTION OF, AN 9. ALL ELECTRICAL OUTLETS WITHIN 6'-0"OF WATER ARE TO BE G.F.C.I. MEANS, METHODS, SCHEDULES, SEQUENCES, SAFETY. SHE CONTRACTORS SHALL BE RESPONSIBLE FOR MAINTAINING A SAFE E ENVIRONMENT FOR 10. AT CH PHONE DATA JACK,PROVIDEINGFOR FROM ABOVE TO WORKERS AND THE PUBLIC AiALL TIMES. BOX. TENANTS 15 RESPONSIBLE NDUCOR BOX. TENANTS DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS AND PROVIDING APPROPRIATE TERMINALS AT FACE PLATE. 11. THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER 11. PROVIDE COLORED FACEPLATES FOR ELECTRICAL OUTLETS& SWITCH PLATES TO TO CONDUCT BUSINESS IN A SAFE AND CLEAN ENVIRONMENT. MATCH EXISTING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TO PURCHASE. 12. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, AN AREA FOR STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER 12. PROVIDE JUNCTION BOXES OR POWER POLES AT WORKSTATIONS WHERE SHOWN. AND PARKING CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING REFER TO THE PLAN FOR THE APPROPRIATE DESIGNATIONS, DATA WILL BE RUN BY THE REST ROOM FACILITIES SHALL BE APPROVED BY THE LANDLORD. ONLY THOSE TENANT'S DATA VENDOR. ELECTRICIAN SO MAKE FINAL CONNECTION FROM DESIGNATED AREAS SHALL BE USED BY CONSTRUCTION CREWS. WORKSTATION WHIP SO JUNCTION BOX, SHE FURNITURE VENDOR IS SO BE RESPONSIBLE FOR WIRING THE BASE PANELS OF THE WORKSTATIONS. 13. THE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS TO MINIMIZE DISTURBANCES OF DAILY TENANT OPERATIONS DURING DEMOLITION AND 13. CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION FURNITURE CONSTRUCTION WORK, DUST PARTITIONS SHALL BE CONSTRUCTED OF 2%4 SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR TO RUNNING WOOD STUDS @24"O.C., INSULATION AND 6 MIL VAPOR BARRIER ON EACH ELECTRICAL CONDUITS SO JUNCTION BOXES. SIDE, 14. VERIFY EXISTING LIGHTING CIRCUITING SIZE NEW CIRCUITS AS REQUIRED. PROVIDE 14. CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE NEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT FIXTURES. DISCOVERED BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF THOSE COMPONENTS AS INDICATED ON THE DRAWINGS, 15. ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEETA.D.A. T.E. WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE REQUIREMENTS AND ARE CONSISTENT THROUGHOUT. INSTALLATION OF LIGHTING FIXTURES AS INDICATED ON THE CEILING PLAN. 16. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE(1) GANG BOX WITH A SINGLE 15. SCHOTT DESIGN,INC., IS NOT RESPONSIBLE FOR THE IDENTIFICATION, COVER PLATE. DISCOVERY, PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE TO ANY PERSONS, THAT OF HAZARDOUS MATERIALS IN ANY FORM ON THE 17. CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED DOWNLIGHTS, PROJECTSITE. SMOKE DETECTORS, SPRINKLER HEADS, AND EXIT SIGNS UNLESS OTHERWISE NOTED. 16. PROVIDE FIRETREATEDWOOD BLOCKING IN WALLS FOR ALL WALL HUNG 18, PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. ITEMS INCLUDING MILLWORK, WALL STOPS, CABINETRY, ETC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE, FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. FINISH NOTES 19. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES(, EMERGENCY aaaaaaa SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM& I. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES( OF THE DEFECTION SYSTEMS AS NECESSARY SO MEET ALL APPLICABLE CODES INDIANA BUILDING CODE FOR CLASS A FIRE RATINGS. (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL 2. FOR ALL NEW DRYWALL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO GYPSUM ASSOCIATION. (SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS, INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE TAPING DETAILS, CORNER BEADS, ETC.( ITEMS AT THEIR EXPENSE. 3. REFERENCE REFLECTED CEILING PLAN AND ELECTRICAL PLAN FOR COLOR OF 20. COORDINATE WITH THE OWNER/TENANT PRIOR TO INSTALLATION OF FIRE DETECTION ELECTRICAL AND DATA DEVICES AND PLATES. REMOVE ALL PLATES BEFORE DEVICES REGARDING ALL DEVICE LOCATIONS TO AVOID CONFLICT WITH FEATURE PAINTING AND REATTACHED AFTERWARDS. CONTRACTOR TO CONFIRM WALLS (CONFERENCE ROOMS AND RECEPTION AREAS( AND TENANT INSTALLED DESIRED COLOR PRIOR TO PURCHASING NEW. ITEMS T.E. PRESENTATION BOARDS, A/V EQUIPMENT AND PROJECTION SCREENS(. 4. ALL AREAS RECEIVING PAINT ARE SO RECEIVE PRIMER COAT AND TWO (2) 21. IF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS FINISH COATS. IN EXISTING SPACES. CONSULT WITH LANDLORD. ALL LAMPS ARE TO BE MATCHING IN C RI AND MANUFACTURER. 5. FOR CHANGE IN FLOOR FINISH MATERIAL PROVIDE TRANSITION STRIP AT DOOR OPENINGS AS NOTED ON FINISH PLAN T.E. WHERE VCS MEETS CARPET(, 22. NEW AND EXISTING PLUMBING LINES IN C EILING ARE TO TO BE INSULATED. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 03/27/19 6. WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE NEW OUTLETS HAVE BEEN INSTALLED, IS CONSIDERED PART OF THE SCOPE OF WORK. PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDING OWNER. 7. REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURRED. 8. WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. 9. SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR PAINTED AS SPECIFIED( TO SCHOTT DESIGN FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS OF ALL MILLWORK. 10. REFERENCE INTERIOR ELEVATION & SECTIONS WHERE PROVIDED FOR ADDITIONAL FINISH INFORMATION, 11, ALL PAINTS AND ADHESIVES/SEALANTS SHALL HAVE LOW VOC CONTENT. 12. ALL ADHESIVESGEALANTS TO BE USED AS RECOMMENDED BY PRODUCT MANUFACTURER. 17. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED SO SCHOTT DESIGN, INC. FOR APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER. 18. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND DELIVERY OF MATERIALS AND EQUIPMENT. 19, ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR NOT, THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL BUILDING CODES, AND STANDARDS FOR GENERAL, MECHANICAL, AND ELECTRICAL CONSTRUCTION. 20. ALL DETAILS,MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BY SCHOTT DESIGN, INC., AND FINAL APPROVAL BY THE OWNER, 21, REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER TRADES. FIELD WORK ORDERS & CHANGE ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE -BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT. 22. FURNITURE, OFFICE EQUIPMENT, OFFICE PARTITION SYSTEMS, REFRIGERATORS, VENDING MACHINES, AND OTHER SIMILAR ITEMS SHOWN DASHED ON THIS DRAWING AND NOT ATTACHED TO THE BUILDING ARE FOR REFERENCE ONLY AND ARE NOT TO BE PROVIDED AS PART OF THE WORK UNLESS SPECIFICALLY STATED TO BE PROVIDED. 23. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS. 24. PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND SWITCH DEVICES BEING REMOVED. PATCH HOLE WITH DRYWALL, TAPE, SPACKLE AND PREPARE FOR FINISH. 25, ALL EQUIPMENTAND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS. 26. EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT SHALL BE CLEAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION THAT REPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERAL CONTRACTOR INSTALLED APPLIANCES WORK & DO NOT LEAK. 27. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS, OR INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF THE PROJECT. 28. ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW GYPSUM BOARD WALL, OR FACE TO FACE OF NEW GYPSUM BOARD WALL. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. 29, CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS. REPLACE ANY DAMAGED OR MISSING WINDOW BLINDS WITH NEW TO MATCH BUILDING STANDARD. 30. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS, AND FEES, THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED DRAWINGS AND SUPPORTING DOCUMENTS SO THE LOCAL BUILDING OFFICIAL AND/OR PERMIT DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL CONTRACTOR UNLESS STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR AGREEMENT, 31. FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS WITH APPROVED FIRE -RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS. 32. WHERE STRUCTURAL BEAMS,DUCTWORK, ETC. PENETRATE SOUND OR FIRE RATED PARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED TO FIT TIGHT, CAULKED AND FIRE DAMPERED IF REQUIRED. 33. CONTRACTOR TO BE AWARE THAT EXISTING CONDITIONS ARE NOT NECESSARILY AN INDICATOR OF BUILDING TYPE. BUILDING TYPE LISTED ON LI00 IS BASED UPON AVAILABLE INFORMATION AND FIELD VERIFICATION. 34. CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS. ALL EXISTING FLOOR AND WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED SO RECEIVE NEW CONSTRUCTION AND FINISHES, ADJUST DOORS AND FRAMES AS REQUIRED. FIRE PROTECTION NOTES I. FIRE EXTINGUISHERS: CONTRACTOR SO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING, MAXIMUM TRAVEL DISTANCE OF 75 FEEF FROM ANY POINT SO A VISIBLE EXTINGUISHER. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. 2. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FI RE SPRINKLER SYSTEM. 3. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE, THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRI NKLER/FIRE SUPPRESSION SYSTEMS. 4. THE FI RE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT, _DEMOLITION NOTES I. COORDINATE DEMOLITION WITH NEW WORK CONSTRUCTION DRAWINGS IN ORDER TO DETERMINE THE FULL EXTENT OF NECESSARY DEMOLITION. SALVAGE REUSABLE ITEMS. 2. NO STRUCTURAL OR LOAD -BEARING CONSTRUCTION SHALL BE REMOVED, DEMOLISHED, OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. PROTECT ALL EXISTING STRUCTURAL MEMBERS DURING DEMOLITION CONSTRUCTION. THE CONTRACTOR SHALL VERIFY IN THE FIELD PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED i0 BE DEMOLISHED ARE NOT STRUCTURAL. CONTACT SCHOTT DESIGN IMMEDIATELY IF THE CONTRACTORS( IN THE FIELD SUSPECT THAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL OR OTHERWISE LOAD -BEARING. BEWARE OF STRUCTURAL COLUMNS AND/OR BEAMS THAT MAY BE CONCEALED BEHIND FINISHES THAT ARE NOTED FOR REMOVAL. EXERCISE CAUTION WHEN DEMOLISHING BUILDING FINISHES OR PARTITIONS ADJACENTTO OR AROUND STRUCTURAL MEMBERS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM. 3. PRIOR TO DEMOLITION, COORDINATE WITH THE OWNER IN THE FIELD REGARDING THOSE ITEMS THAT MAY BE REMOVED AND REUSED. CONFIRM WITH THE OWNER THOSE ITEMS THE OWNER CHOOSES TO RETAIN FROM DEMOLITION, AND THOSE ITEMS OF WHICH THE OWNER CHOOSES TO DISPOSE. COMPLY WITH THE OWNER'S REQUESTS. 4. WHERE EQUIPMENT,FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF THE BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE IN THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE REMAINING AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE DIRECTED BY OWNER. 5. REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, OR DASHED LINES. NOTE THAT SOME ITEMS HAVE NOT BEEN SHOWN ON DEMOLITION PLAN. VISIT AREA OF WORK SO ASSURE EXTENT OF DEMOLITION. 6. REMOVE ALL CARPEL VINYL BASE,VCT, WALL FABRIC, AND ANY OTHER FINISHES AS REQUIRED FOR NEW CONSTRUCTION. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS. REFER SO FINISH PLAN/SCHEDULE FOR CLARIFICATION OF EXISTING FINISHES TO REMAIN. 7. REMOVE ALL ELECTRICAL OUTLETS AND CONDUCTORS AS REQUIRED OR INDICATED. SALVAGE OUTLETS FOR REUSE IN NEW CONSTRUCTION. 8. REFER TO DEMOLITION PLAN AND REFLECTED CEILING PLAN LEGEND FOR CEILING GRID INSTRUCTIONS. 9. USE CARE TO PROTECT EXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS TO REMAIN SUCH AS, BUT NOT LIMITED TO, EXISTING CEILING GRID, TILES, FIRE SUPPRESSION EQUIPMENT, DIFFUSERS, LIGHT FIXTURES, EQUIPMENT, CASEWORK, AND FINISHES, THE CONTRACTOR SHALL REPLACE AND/OR REPAIR, AT THE CONTRACTOR'S COST, ANY SUCH ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE OTHERWISE BEEN REASONABLY PROTECTED AND MAINTAINED IN GOOD CONDITION FOR THE OWNER'S USE IN THE PROJECT. 10. PER THE INDIANA ELECTRICAL CODE (SPREAD OF FIRE OR PRODUCTS OF COMBUSTION( REMOVE ALL ACCESSIBLE PORTIONS OF ABANDONED CABLES AND WIRING INCLUDING BUT NOT LIMITED TO: DATA WIRING, COMMUNICATIONS WIRING, FIRE ALARM CABLES, AUDIO CABLES, COAXIAL CABLES, FIBER OPTIC CABLES/ RACEWAYS, A ND PLTC CABLES. REFER SO SECT ION 300.21. 11. WHERE FIXTURES OR EQUIPMENT ARE REMOVED FROM ANY ELECTRICAL, PLUMBING, MECHANICAL, OR VOICE/DATA SYSTEMS, ALL REMAINING TERMINATIONS SHALL BE CLOSED AND PROTECTED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND GOVERNING SAFETY REGULATIONS OR PROCEDURES. TAKE BACK TO SOURCE IF NOT BEING REUSED. MARK, LABEL, OR FLAG ALL TERMINATED SYSTEMS FOR FUTURE REFERENCE. CONTRACTOR TO PROVIDE AN"AS-BUILT'SET INDICATING THE LOCATION OF ALL PERMANENTLY ABANDONED SYSTEMS. 12. GENERAL CONTRACTOR TO PROVIDE RECYCLING COSTS TO THE BUILDING OWNER/LANDLORD ON ALL ITEMS BEING DEMOLISHED, SUCH AS, METAL STUDS, DRYWALL, CARPET, CEILING TILES, DOORS,GLASS, AND CABINETRY. MILL/CASEWORK NOTES I. CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWINGS ARE TO BE PROVIDED UNDER THE GENERAL CONTRACT. 2. UNLESS INDICATED OTHERWISE, COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE (A.W.I.( CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK. 3. FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE TENANTAND SCHOTT DESIGN PRIOR TO FABRICATION. 4. WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON PLANS AGAINST DIMENSIONS OF AS -BUILT CONDITIONS IN FIELD, REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. MAKE ADJUSTMENTS SO CASEWORK AND MILLWORK SO FIT FIELD CONDITIONS UNLESS DOING SO WILL SIGNIFICANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS. 5. VERIFY FINISHES (LAMINATE VENEER, STAIRS, ETC.( ON THE SECTIONS AND ELEVATION DRAWINGS WITH FINISHES INDICATED ON THE FINISH PLAN/SCHEDULES, IMMEDIATELY REPORT ANY DISCREPANCIES SO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. 6. REFER SO MILLWORK SECTIONS & ELEVATIONS, UNLESS OTHERWISE SHOWN, PLASTIC LAMINATE CLAD, COUNTERTOPS WITH 4" BACKSPLASHES WHERE INDICATED. BACKSPLASHES TO BE FIELD APPLIED. 7. EDGES OF PLASTIC LAMINATE COUNTERTOPS, CABINETS AND DRAWERS TO BE PLASTIC LAMINATE AND NOT PVC OR OTHER STOCK PLASTIC EDGING UNLESS NOTED OTHERWISE. IF PVC EDGING IS BEING PROPOSED BY FABRICATOR FOR EDGES OF CABINETS AND DRAWERS, FABRICATOR MUST PROVIDE SAMPLE OF COLOR MATCHING SPECIFIED PLASTIC LAMINATE FOR APPROVAL. B. REFER TO MILLWORK SECTIONS & ELEVATIONS FOR CABI NETRY SPECIFICATIONS (CUSTOM PLASTIC LAMINATE OR PRE -MANUFACTURED STOCK CABINETRY(. 9. SO PROVIDE BLOCKING IN WALLS FOR ALL MILLWORK, WALL STOPS, HARDWARE, AND CABINETRY WHERE SPECIFIED. ALL WOOD BLOCKING TO BE FIRE RATED. 5. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDE MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE. FIELD VERIFY EXISTING CONDITIONS PRIOR SO SHE STARS OF WORK, 6. FIRE STOP ANY EXISTING DECK PENETRATIONS. DOCUMENT APPROVAL TENANUCLI ENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE SCOPE OF WORK CONTAINED IN THESE DOCUMENTS. TENANT/CLIENT COMANY NAME TENANT REPRESENTATIVE SIGNATURE TENANT REPRESENTATIVE PRINTED NAME DATE ALL COSTS INCURRED DUE SO ANY CHANGES REQUESTED AFTER SIGN -OFF OF THESE DOCUMENTS SHALL BE THE FULL RESPONSIBILITY OF THE TENANT/CLIENT, THESE DRAWINGS, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT SO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. Carmel T s F an ,. ,.._. IT Hills Nall Hoip wnn 1nnn M,.N,F.a,. .,,.., Aroma m111ry n„e . .,.. mm.Molo.k0 ., 9 �m'Nmw C wi,.a N01111 r p,.,, m VICINITY MAP NOT TO SCALE N KEY PLAN - 4TH FLOOR NOT TO SCALE INDEX OF DRAWINGS TI II COVER SHEET AND GENERAL PROJECT NOTES L100 LIFE SAFETY PLAN Alit DEMOLITION PLAN & ARCHITECTURAL FLOOR PLAN AI21 ELECTRICAL PLAN & REFLECTED CEILING PLAN AI31 FINISH PLAN A211 FINISH PLAN & DOOR SCHEDULE all N d O U N O V t �n Z� - .o -�'m KID =MnU w O O O L W OM V O C C 'vVw] THIS DRAWING, AND THE IDEAS, iESIGNS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC_ AND ARE NOT TO BE ISED OR REPRODUCED IN WHOLE, OR IN PAR, WITHOUTTHE WRITTEN CONSENT OF SCHOTT DESIGN. N ri 0 NO 0 W�- A/ W J mi UV E U .LuV ,e Z Q ^' aaaJ i z Q Q Vo V _ Q LLJ L Q z ISSUE DATE DESCRIPTION 02.21.19 REVIEW SET REVISIONS ARK DATE DB DESCRIPTION PROJECT NUMBER 2019.008 PROD. MGR DRAWN BY AS SLF weew 4TH FLOOR COVER SHEET AND GENERAL NOTES T111