HomeMy WebLinkAboutT111 Cover Sheet & General NotesMECHANICAL & ELECTRICAL NOTES GENERAL PROJECT NOTES
I.
THE MECHANICAL, ELECTRICAL AND PLUMBING SCOPES OF WORK ARE LIMITED TO
I.
ALL WORKS HALL COMPLY WITH THE REQU I REMENTS OF THE EXISTING BU I LD I NG
BASIC DESIGN -BUILD ALTERATIONS WHICH ARE OUTLINED IN THESE PLANS. THE
CONSTRUCTION TYPE AS DEFINED BY SECTION 601 OF THE INDIANA BUILDING
DESIGN -BUILD CONTRACTORS FOR EACH TRADE MUST NOTIFY THE ARCHITECT IF THEY
CODE.
FIND THAT THE SCOPE OF WORK EXCEEDS THE LEVEL OF MECHANICAL, ELECTRICAL
OR PLUMBING WORK INDICATED ON THESE DRAWINGS SO THAT ANY NECESSARY
2.
ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE
ENGINEERING CAN OCCUR AND ADDITIONAL PLANS CAN BE FILED, OR IF
AND LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR
ADDITIONAL INFORMATION IS NEEDED IN ORDER TO DO THE WORK IN THE FIELD. THE
VERIFYING THE CURRENT APPLICABLE BUILDING CODE(S)FORTNEIR
MECHANICAL, ELECTRICAL AND PLUMBING DESIGN -BUILD CONTRACTORS SHALL
RESPECTIVE SCOPE OF WORK.
COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE
SUPPRESSION AND FIRE ALARM SYSTEMS SHALL BE INSTALLED BY THE APPROPRIATE
3.
CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE
DESIGN -BUILD CONTRACTOR AND MUST COMPLY WITH ALL APPLICABLE STATE AND
DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING
LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM DESIGN -BUILD
CONDITIONS OR NEW WORK REQUIREMENTS. CONTRACTORS( SHALL MAKE
CONTRACTORS ARE RESPONSIBLE FOR COMPLETING AND FILING THE R PLANS AND
THEMSELVES FAMILIAR WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY
OBTAINING iH El PERMITS.
AWARE OF THE REQUIREMENTS OF THE SCOPE OF WORK.
2.
MECHANICAL WORK 15 LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE
4.
FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. I GENERAL
DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE
NG
CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTIONNIFIF EXISTING
BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS
CONDITIONS PREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT
AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT
SCALE DRAWINGS. NOTED DIMENSIONS TAKE PRECEDENCE.
IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF
ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
5.
VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT
MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE
ANY DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO SCHOTT
CODES.
DESIGN, INC.
3.
VERIFY HEAT LOADS OF ANY SPECIAL EQUIPMENT IN THE TENANT SPACE, AND
6.
THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER
PROVIDE ADDITIONAL AIR FLOW IF REQUIRED, CONFIRM WITH OWNER PRIOR SO ANY
REGARDING ALL ON -SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK
PURCHASE OF NEW EQUIPMENT. REVISE ZONING IF REQUIRED. DO NOT DESIGN ANY
SCHEDULE, MATERIALS STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE
SINGLE OFFICE SPACE TO BE ON A SPLIT ZONE UNLESS APPROVED BY BUILDING
WORK SITE, TRAFFIC CONTROL, AND BUILDING/PUBLIC SAFETY PROCEDURES
OWNER/LANDLORD.
DURING CONSTRUCTION, THE CONTRACTOR SHALL ALSO COORDINATE
WORK "BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS NECESSARY SO EXECUTE
4.
RELOCATE AIR -SUPPLY DIFFUSERS AND RETURN -AIR GRILLES AS REQUIRED. PROVIDE
THE OVERALL PROJECT SCOPE.
PROPER Al R SUPPLY FOR DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES.
LOCATION OF DIFFUSERS SHOWN ON PLAN IS FOR REFERENCE ONLY. CONTRACTOR
7,
THE GEN FRAIL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY
IS TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS REQUIRED BY
WORKING HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR
CODE.
TO AND DURING HOLIDAYS. LANDLORD RESERVES THE RIGHT TO RESTRICT
CONSTRUCTION SO NIGHTS AND WEEKENDS WHEN THAT CONSTRUCTION IS
5.
POSITION LOCATION OF ALL THERMOSTATS WHERE APPROPRIATE PER MECHANICAL
DEEMED TO INTERFERE WITH THE OPERATIONS OF ADJACENT TENANTS.
DESIGN. COORDINATE WITH TENANT AND BUILDING OWNER FOR FURNITURE PANEL
OR OTHER CONFLICTS. PROVIDE BALANCE REPORTS TO OWNER UPON COMPLETION
B.
FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR
OF PROJECT.
SHALL COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND
COMMUNICATE TO THE OWNER, TENANT, AND SCHOTT DESIGN WHEN
6.
ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE
DECISIONS MUST BE RENDERED IN ORDER FOR THE CONTRACTOR TO MEET THE
DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF
PROJECT SCHEDULE. THE OWNER,TENANT, OR DESIGNER/ARCHITECT IS NOT
ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF
RESPONSIBLE FOR DELAYS RESULTING FROM THE CONTRACTOR'S FAILURE TO
THE EXISTING ELECTRICAL SERVICE IN THE BUILDING, ELECTRICAL CONTRACTOR IS SO
COMMUNICATE MATERIAL LEAD TIMES.
NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL
PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES,
9.
SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED
WITHOUT PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR
7.
COMPLY WITH THE I NDIANA ELECTRICAL AND MECHANICAL CODE AND ALL OTHER
SUBSTITUTIONS WITH APPROPRIATE SUPPORT INFORMATION SO THE DESIGNER.
APPLICABLE CODES.
ALLOW REASONABLY SUFFICIENT TIME FOR THE DESIGNER SO REVIEW THE
REQUEST AND RENDER A DECISION.
8.
SIZE AND CIRCUIT ELECTRICAL POWER ITEMS. PROVIDE OR REUSE ELECTRICAL POWER
AND DATA OUTLETS AS REQUIRED.
10.
DESIGN, INC.,SHALL HOT HAVE CONTROL OVER, ORBE IN CHARGE
OF, AND SHALL NOT BE RESPONSIBLE FORA CONTRACTOR'S CONSTRUCTION
OF, AN
9.
ALL ELECTRICAL OUTLETS WITHIN 6'-0"OF WATER ARE TO BE G.F.C.I.
MEANS, METHODS, SCHEDULES, SEQUENCES, SAFETY. SHE CONTRACTORS
SHALL BE RESPONSIBLE FOR MAINTAINING A SAFE
E ENVIRONMENT FOR
10.
AT CH PHONE DATA JACK,PROVIDEINGFOR FROM ABOVE TO
WORKERS AND THE PUBLIC AiALL TIMES.
BOX. TENANTS 15 RESPONSIBLE NDUCOR
BOX. TENANTS DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS
AND PROVIDING APPROPRIATE TERMINALS AT FACE PLATE.
11.
THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP
PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER
11.
PROVIDE COLORED FACEPLATES FOR ELECTRICAL OUTLETS& SWITCH PLATES TO
TO CONDUCT BUSINESS IN A SAFE AND CLEAN ENVIRONMENT.
MATCH EXISTING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TO
PURCHASE.
12.
THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, AN
AREA FOR STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER
12.
PROVIDE JUNCTION BOXES OR POWER POLES AT WORKSTATIONS WHERE SHOWN.
AND PARKING CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING
REFER TO THE PLAN FOR THE APPROPRIATE DESIGNATIONS, DATA WILL BE RUN BY THE
REST ROOM FACILITIES SHALL BE APPROVED BY THE LANDLORD. ONLY THOSE
TENANT'S DATA VENDOR. ELECTRICIAN SO MAKE FINAL CONNECTION FROM
DESIGNATED AREAS SHALL BE USED BY CONSTRUCTION CREWS.
WORKSTATION WHIP SO JUNCTION BOX, SHE FURNITURE VENDOR IS SO BE
RESPONSIBLE FOR WIRING THE BASE PANELS OF THE WORKSTATIONS.
13.
THE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS TO MINIMIZE
DISTURBANCES OF DAILY TENANT OPERATIONS DURING DEMOLITION AND
13.
CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION FURNITURE
CONSTRUCTION WORK, DUST PARTITIONS SHALL BE CONSTRUCTED OF 2%4
SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR TO RUNNING
WOOD STUDS @24"O.C., INSULATION AND 6 MIL VAPOR BARRIER ON EACH
ELECTRICAL CONDUITS SO JUNCTION BOXES.
SIDE,
14.
VERIFY EXISTING LIGHTING CIRCUITING SIZE NEW CIRCUITS AS REQUIRED. PROVIDE
14.
CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE
NEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT FIXTURES.
DISCOVERED BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT
THE INSTALLATION OF THOSE COMPONENTS AS INDICATED ON THE DRAWINGS,
15.
ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEETA.D.A.
T.E. WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE
REQUIREMENTS AND ARE CONSISTENT THROUGHOUT.
INSTALLATION OF LIGHTING FIXTURES AS INDICATED ON THE CEILING PLAN.
16.
WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE(1) GANG BOX WITH A SINGLE
15.
SCHOTT DESIGN,INC., IS NOT RESPONSIBLE FOR THE IDENTIFICATION,
COVER PLATE.
DISCOVERY, PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE
TO ANY PERSONS, THAT OF HAZARDOUS MATERIALS IN ANY FORM ON THE
17.
CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED DOWNLIGHTS,
PROJECTSITE.
SMOKE DETECTORS, SPRINKLER HEADS, AND EXIT SIGNS UNLESS OTHERWISE NOTED.
16.
PROVIDE FIRETREATEDWOOD BLOCKING IN WALLS FOR ALL WALL HUNG
18,
PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC.
ITEMS INCLUDING MILLWORK, WALL STOPS, CABINETRY, ETC.
EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER
SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE, FIXTURES
SHOWN ON PLAN ARE FOR REFERENCE ONLY.
FINISH NOTES
19.
PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES(, EMERGENCY
aaaaaaa
SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM&
I.
ALL FINISHES SHALL COMPLY WITH CHAPTER 8
(INTERIOR FINISHES( OF THE
DEFECTION SYSTEMS AS NECESSARY SO MEET ALL APPLICABLE CODES
INDIANA BUILDING CODE FOR CLASS A FIRE RATINGS.
(INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA. IN RECEPTION
AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL
2.
FOR ALL NEW DRYWALL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE
LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO
GYPSUM ASSOCIATION. (SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS,
INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE
TAPING DETAILS, CORNER BEADS, ETC.(
ITEMS AT THEIR EXPENSE.
3.
REFERENCE REFLECTED CEILING PLAN AND ELECTRICAL PLAN FOR COLOR OF
20.
COORDINATE WITH THE OWNER/TENANT PRIOR TO INSTALLATION OF FIRE DETECTION
ELECTRICAL AND DATA DEVICES AND PLATES. REMOVE ALL PLATES BEFORE
DEVICES REGARDING ALL DEVICE LOCATIONS TO AVOID CONFLICT WITH FEATURE
PAINTING AND REATTACHED AFTERWARDS. CONTRACTOR TO CONFIRM
WALLS (CONFERENCE ROOMS AND RECEPTION AREAS( AND TENANT INSTALLED
DESIRED COLOR PRIOR TO PURCHASING NEW.
ITEMS T.E. PRESENTATION BOARDS, A/V EQUIPMENT AND PROJECTION SCREENS(.
4.
ALL AREAS RECEIVING PAINT ARE SO RECEIVE PRIMER COAT AND TWO (2)
21.
IF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS
FINISH COATS.
IN EXISTING SPACES. CONSULT WITH LANDLORD. ALL LAMPS ARE TO BE MATCHING
IN C RI AND MANUFACTURER.
5.
FOR CHANGE IN FLOOR FINISH MATERIAL PROVIDE TRANSITION STRIP AT DOOR
OPENINGS AS NOTED ON FINISH PLAN T.E. WHERE VCS MEETS CARPET(,
22.
NEW AND EXISTING PLUMBING LINES IN C EILING ARE TO TO BE INSULATED.
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
DATE: 03/27/19
6. WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING
WHERE NEW OUTLETS HAVE BEEN INSTALLED, IS CONSIDERED PART OF THE
SCOPE OF WORK. PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR
TENANT AND BUILDING OWNER.
7. REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURRED.
8. WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT
TO MATCH ADJACENT WALL FINISH.
9. SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR PAINTED AS SPECIFIED( TO
SCHOTT DESIGN FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS
OF ALL MILLWORK.
10. REFERENCE INTERIOR ELEVATION & SECTIONS WHERE PROVIDED FOR
ADDITIONAL FINISH INFORMATION,
11, ALL PAINTS AND ADHESIVES/SEALANTS SHALL HAVE LOW VOC CONTENT.
12. ALL ADHESIVESGEALANTS TO BE USED AS RECOMMENDED BY PRODUCT
MANUFACTURER.
17. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED SO SCHOTT DESIGN,
INC. FOR APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR
CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE
DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL
NUMBER.
18. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW
SUFFICIENT TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND
DELIVERY OF MATERIALS AND EQUIPMENT.
19, ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST
QUALITY STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR
NOT, THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL
WORK IS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL BUILDING
CODES, AND STANDARDS FOR GENERAL, MECHANICAL, AND ELECTRICAL
CONSTRUCTION.
20. ALL DETAILS,MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST
APPROVAL BY SCHOTT DESIGN, INC., AND FINAL APPROVAL BY THE OWNER,
21, REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH
ALL OTHER TRADES. FIELD WORK ORDERS & CHANGE ORDERS WILL NOT BE
APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN
ACCOUNTED FOR BY THE BIDDER DURING PRE -BID FIELD INSPECTION AND
AFTER AWARD OF CONTRACT.
22. FURNITURE, OFFICE EQUIPMENT, OFFICE PARTITION SYSTEMS, REFRIGERATORS,
VENDING MACHINES, AND OTHER SIMILAR ITEMS SHOWN DASHED ON THIS
DRAWING AND NOT ATTACHED TO THE BUILDING ARE FOR REFERENCE ONLY
AND ARE NOT TO BE PROVIDED AS PART OF THE WORK UNLESS SPECIFICALLY
STATED TO BE PROVIDED.
23. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT
REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION.
PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR
ADJOIN TO EXISTING CORE WALLS.
24. PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND
SWITCH DEVICES BEING REMOVED. PATCH HOLE WITH DRYWALL, TAPE,
SPACKLE AND PREPARE FOR FINISH.
25, ALL EQUIPMENTAND/OR FIXTURES SHALL BE INSTALLED IN STRICT
ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR
INSTRUCTIONS.
26. EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON
COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT
SHALL BE CLEAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A
CONDITION THAT REPRESENTS THE HIGHEST LEVEL OF CARE AND
PROFESSIONALISM. ENSURE ALL GENERAL CONTRACTOR INSTALLED
APPLIANCES WORK & DO NOT LEAK.
27. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS,
OR INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF
THE PROJECT.
28. ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW
GYPSUM BOARD WALL, OR FACE TO FACE OF NEW GYPSUM BOARD WALL.
DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN.
29, CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING
WINDOW BLINDS. REPLACE ANY DAMAGED OR MISSING WINDOW BLINDS
WITH NEW TO MATCH BUILDING STANDARD.
30. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE
REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS,
AND FEES, THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
SUBMITTING ALL REQUIRED DRAWINGS AND SUPPORTING DOCUMENTS SO THE
LOCAL BUILDING OFFICIAL AND/OR PERMIT DEPARTMENT. ALL REQUIRED
LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL CONTRACTOR UNLESS
STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR AGREEMENT,
31. FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS
WITH APPROVED FIRE -RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS.
32. WHERE STRUCTURAL BEAMS,DUCTWORK, ETC. PENETRATE SOUND OR FIRE
RATED PARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED TO FIT TIGHT,
CAULKED AND FIRE DAMPERED IF REQUIRED.
33. CONTRACTOR TO BE AWARE THAT EXISTING CONDITIONS ARE NOT
NECESSARILY AN INDICATOR OF BUILDING TYPE. BUILDING TYPE LISTED ON
LI00 IS BASED UPON AVAILABLE INFORMATION AND FIELD VERIFICATION.
34. CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS. ALL EXISTING
FLOOR AND WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED
SO RECEIVE NEW CONSTRUCTION AND FINISHES, ADJUST DOORS AND FRAMES
AS REQUIRED.
FIRE PROTECTION NOTES
I. FIRE EXTINGUISHERS: CONTRACTOR SO ENSURE ALL NEW AND EXISTING FIRE
EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH
OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING, MAXIMUM TRAVEL
DISTANCE OF 75 FEEF FROM ANY POINT SO A VISIBLE EXTINGUISHER.
THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES.
2. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE
GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT
DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR
RENOVATION OF THE FI RE SPRINKLER SYSTEM.
3. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING
CODE, THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES
AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE
SPRI NKLER/FIRE SUPPRESSION SYSTEMS.
4. THE FI RE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS,
AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE
AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT,
_DEMOLITION NOTES
I. COORDINATE DEMOLITION WITH NEW WORK CONSTRUCTION DRAWINGS IN ORDER
TO DETERMINE THE FULL EXTENT OF NECESSARY DEMOLITION. SALVAGE REUSABLE
ITEMS.
2. NO STRUCTURAL OR LOAD -BEARING CONSTRUCTION SHALL BE REMOVED,
DEMOLISHED, OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY
NOTED OTHERWISE ON THE DRAWINGS. PROTECT ALL EXISTING STRUCTURAL MEMBERS
DURING DEMOLITION CONSTRUCTION. THE CONTRACTOR SHALL VERIFY IN THE FIELD
PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED i0 BE DEMOLISHED ARE NOT
STRUCTURAL. CONTACT SCHOTT DESIGN IMMEDIATELY IF THE CONTRACTORS( IN THE
FIELD SUSPECT THAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL
OR OTHERWISE LOAD -BEARING. BEWARE OF STRUCTURAL COLUMNS AND/OR BEAMS
THAT MAY BE CONCEALED BEHIND FINISHES THAT ARE NOTED FOR REMOVAL.
EXERCISE CAUTION WHEN DEMOLISHING BUILDING FINISHES OR PARTITIONS
ADJACENTTO OR AROUND STRUCTURAL MEMBERS. THE CONTRACTOR IS SOLELY
RESPONSIBLE FOR INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM.
3. PRIOR TO DEMOLITION, COORDINATE WITH THE OWNER IN THE FIELD REGARDING
THOSE ITEMS THAT MAY BE REMOVED AND REUSED. CONFIRM WITH THE OWNER
THOSE ITEMS THE OWNER CHOOSES TO RETAIN FROM DEMOLITION, AND THOSE ITEMS
OF WHICH THE OWNER CHOOSES TO DISPOSE. COMPLY WITH THE OWNER'S
REQUESTS.
4. WHERE EQUIPMENT,FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF
THE BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE
IN THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE
REMAINING AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE
DIRECTED BY OWNER.
5. REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, OR
DASHED LINES. NOTE THAT SOME ITEMS HAVE NOT BEEN SHOWN ON DEMOLITION
PLAN. VISIT AREA OF WORK SO ASSURE EXTENT OF DEMOLITION.
6. REMOVE ALL CARPEL VINYL BASE,VCT, WALL FABRIC, AND ANY OTHER FINISHES AS
REQUIRED FOR NEW CONSTRUCTION. CONTRACTOR TO FIELD VERIFY EXISTING
CONDITIONS. REFER SO FINISH PLAN/SCHEDULE FOR CLARIFICATION OF EXISTING
FINISHES TO REMAIN.
7. REMOVE ALL ELECTRICAL OUTLETS AND CONDUCTORS AS REQUIRED OR INDICATED.
SALVAGE OUTLETS FOR REUSE IN NEW CONSTRUCTION.
8. REFER TO DEMOLITION PLAN AND REFLECTED CEILING PLAN LEGEND FOR CEILING
GRID INSTRUCTIONS.
9. USE CARE TO PROTECT EXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS
TO REMAIN SUCH AS, BUT NOT LIMITED TO, EXISTING CEILING GRID, TILES, FIRE
SUPPRESSION EQUIPMENT, DIFFUSERS, LIGHT FIXTURES, EQUIPMENT, CASEWORK, AND
FINISHES, THE CONTRACTOR SHALL REPLACE AND/OR REPAIR, AT THE CONTRACTOR'S
COST, ANY SUCH ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE
OTHERWISE BEEN REASONABLY PROTECTED AND MAINTAINED IN GOOD CONDITION
FOR THE OWNER'S USE IN THE PROJECT.
10. PER THE INDIANA ELECTRICAL CODE (SPREAD OF FIRE OR PRODUCTS OF
COMBUSTION( REMOVE ALL ACCESSIBLE PORTIONS OF ABANDONED CABLES AND
WIRING INCLUDING BUT NOT LIMITED TO: DATA WIRING, COMMUNICATIONS WIRING,
FIRE ALARM CABLES, AUDIO CABLES, COAXIAL CABLES, FIBER OPTIC
CABLES/ RACEWAYS, A ND PLTC CABLES. REFER SO SECT ION 300.21.
11. WHERE FIXTURES OR EQUIPMENT ARE REMOVED FROM ANY ELECTRICAL, PLUMBING,
MECHANICAL, OR VOICE/DATA SYSTEMS, ALL REMAINING TERMINATIONS SHALL BE
CLOSED AND PROTECTED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND
GOVERNING SAFETY REGULATIONS OR PROCEDURES. TAKE BACK TO SOURCE IF NOT
BEING REUSED. MARK, LABEL, OR FLAG ALL TERMINATED SYSTEMS FOR FUTURE
REFERENCE. CONTRACTOR TO PROVIDE AN"AS-BUILT'SET INDICATING THE LOCATION
OF ALL PERMANENTLY ABANDONED SYSTEMS.
12. GENERAL CONTRACTOR TO PROVIDE RECYCLING COSTS TO THE BUILDING
OWNER/LANDLORD ON ALL ITEMS BEING DEMOLISHED, SUCH AS, METAL STUDS,
DRYWALL, CARPET, CEILING TILES, DOORS,GLASS, AND CABINETRY.
MILL/CASEWORK NOTES
I. CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWINGS ARE TO BE
PROVIDED UNDER THE GENERAL CONTRACT.
2. UNLESS INDICATED OTHERWISE, COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE
(A.W.I.( CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK.
3. FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE
TENANTAND SCHOTT DESIGN PRIOR TO FABRICATION.
4. WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON
PLANS AGAINST DIMENSIONS OF AS -BUILT CONDITIONS IN FIELD, REPORT ANY
DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. MAKE
ADJUSTMENTS SO CASEWORK AND MILLWORK SO FIT FIELD CONDITIONS UNLESS DOING
SO WILL SIGNIFICANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS.
5. VERIFY FINISHES (LAMINATE VENEER, STAIRS, ETC.( ON THE SECTIONS AND ELEVATION
DRAWINGS WITH FINISHES INDICATED ON THE FINISH PLAN/SCHEDULES, IMMEDIATELY
REPORT ANY DISCREPANCIES SO SCHOTT DESIGN THROUGH THE GENERAL
CONTRACTOR.
6. REFER SO MILLWORK SECTIONS & ELEVATIONS, UNLESS OTHERWISE SHOWN, PLASTIC
LAMINATE CLAD, COUNTERTOPS WITH 4" BACKSPLASHES WHERE INDICATED.
BACKSPLASHES TO BE FIELD APPLIED.
7. EDGES OF PLASTIC LAMINATE COUNTERTOPS, CABINETS AND DRAWERS TO BE PLASTIC
LAMINATE AND NOT PVC OR OTHER STOCK PLASTIC EDGING UNLESS NOTED OTHERWISE.
IF PVC EDGING IS BEING PROPOSED BY FABRICATOR FOR EDGES OF CABINETS AND
DRAWERS, FABRICATOR MUST PROVIDE SAMPLE OF COLOR MATCHING SPECIFIED
PLASTIC LAMINATE FOR APPROVAL.
B. REFER TO MILLWORK SECTIONS & ELEVATIONS FOR CABI NETRY SPECIFICATIONS
(CUSTOM PLASTIC LAMINATE OR PRE -MANUFACTURED STOCK CABINETRY(.
9. SO PROVIDE BLOCKING IN WALLS FOR ALL MILLWORK, WALL STOPS, HARDWARE, AND
CABINETRY WHERE SPECIFIED. ALL WOOD BLOCKING TO BE FIRE RATED.
5. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDE
MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE.
FIELD VERIFY EXISTING CONDITIONS PRIOR SO SHE STARS OF WORK,
6. FIRE STOP ANY EXISTING DECK PENETRATIONS.
DOCUMENT APPROVAL
TENANUCLI ENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE SCOPE OF WORK CONTAINED IN THESE DOCUMENTS.
TENANT/CLIENT COMANY NAME TENANT REPRESENTATIVE SIGNATURE TENANT REPRESENTATIVE PRINTED NAME DATE
ALL COSTS INCURRED DUE SO ANY CHANGES REQUESTED AFTER SIGN -OFF OF THESE DOCUMENTS SHALL BE THE FULL RESPONSIBILITY OF THE TENANT/CLIENT,
THESE DRAWINGS, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT SO BE
USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.
Carmel
T
s
F
an
,. ,.._.
IT Hills Nall
Hoip
wnn
1nnn
M,.N,F.a,.
.,,..,
Aroma m111ry n„e
. .,..
mm.Molo.k0
.,
9
�m'Nmw
C
wi,.a N01111
r
p,.,, m
VICINITY
MAP
NOT TO SCALE
N
KEY PLAN - 4TH FLOOR
NOT TO SCALE
INDEX OF DRAWINGS
TI II COVER SHEET AND GENERAL PROJECT NOTES
L100 LIFE SAFETY PLAN
Alit DEMOLITION PLAN & ARCHITECTURAL FLOOR PLAN
AI21 ELECTRICAL PLAN & REFLECTED CEILING PLAN
AI31 FINISH PLAN
A211 FINISH PLAN & DOOR SCHEDULE
all
N
d O U
N
O
V t
�n
Z� -
.o
-�'m
KID
=MnU
w
O O
O L
W
OM V
O
C
C
'vVw]
THIS DRAWING, AND THE IDEAS,
iESIGNS AND CONCEPTS CONTAINED
HEREIN. ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC_ AND ARE NOT TO BE
ISED OR REPRODUCED IN WHOLE, OR
IN PAR, WITHOUTTHE WRITTEN
CONSENT OF SCHOTT DESIGN.
N
ri
0
NO
0
W�-
A/
W
J
mi
UV E U
.LuV ,e
Z Q ^'
aaaJ i z Q
Q Vo
V _
Q LLJ
L
Q
z
ISSUE
DATE
DESCRIPTION
02.21.19
REVIEW SET
REVISIONS
ARK
DATE
DB
DESCRIPTION
PROJECT NUMBER
2019.008
PROD. MGR DRAWN BY
AS SLF
weew
4TH FLOOR
COVER SHEET AND
GENERAL NOTES
T111