Loading...
HomeMy WebLinkAboutA111 Demolition Plan - Architectural Floor PlanDEMOLITION LEGEND DEMO GENERAL NOTES WALL TYPES PLAN NOTES WE EXISTING TO BE REMOVED EXISTING TO REMAIN WALL vzozox PARTIAL HEIGHT WALL DOOR AND FRAME oo--�= WINDOW /SIDELIGHT Ji - L CEILING GRID AND TILES, 2'x4' CEILING GRID AND TILES, 2'x2' Fri =mm= SUPPLY AIR DIFFUSERS 11 LIGHT FIXTURE, L� __ i' FLUORESCENT, 2'x4' G TI LIGHT FIXTURE, I l FLUORESCENT, 2'x2' 3'� LIGHT FIXTURE, CAN -rH LIGHT FIXTURE, TRACK LIGHT FIXTURE, SCONCE LIGHT FIXTURE, �'-P `T' PENDANT LIGHT SWITCH �^ EXIT LIGHT ���0iZ4 ELECTRIC OUTLEi(S) DATA OR :0 COMMUNICATION OUTLET WALL I. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS SHOWN ON PLAN PER LEGEND. PATCH WALL AND PREPARE FOR NEW FINISHES AS REQUIRED. PARTIAL HEIGHT WALL DEMOLITION PLAN NOTES 7 DOOR AND FRAME 001 REMOVE EXISTING CABINETRY AND COUNTERTOP. x WINDOW/SIDELIGHT D02 REMOVE EXISTING CABINETRY, COUNTER TOP AND PLUMBING FIXTURE (WHERE APPLICABLE) AND SALVAGE FOR RELOCATION. SEE ARCHITECTURAL PLAN FOR MORE INFORMATION. EXISTING SINK TO BE REMOVED AND SALVAGED WITH EXISTING 003 CASEWORK. NO SERVICE SINKS ARE BEING REMOVED. REMOVE EXISTING SUSPENDED PANELS AND ALL ASSOCIATED DO4 HARDWARE. PATCH AND REPAIR SURFACES AS REQUIRED AND PREP TO RECEIVE NEW FINISHES. DOS REMOVE EXISTING GLASS PANELS AT THIS LOCATION, PATCH AND REPAIR SURFACES AS REQUIRED AND PREP TO RECEIVE NEW FINISHES, 008 REMOVE EXISTING CEILING GRID, TILE AND LIGHT FIXTURES AS SHOWN. SEE REFLECTED CEILING PLAN FOR MORE INFORMATION. DO REMOVE ALL PENDANT LIGHT FIXTURES IN THIS AREA AND SALVAGE FOR REUSE, SEE REFLECTED CEILING PLAN FOR MORE INFORMATION. OREMOVE EXISTING FLOOR CORE AND INFILL AS REQUIRED TO D08 MAINTAIN BUILDING CONSTRUCTION TYPE. PREPARE FLOOR FOR NEW FINISHES AS REQUIRED. WHERE HATCHED AREA IS SHOWN, REMOVE EXISTING DRYWALL DOB BULKHEAD AT THIS LOCATION. REPAIR EXPOSED CEILING ABOVE AS REQUIRED. SEE REFLECTED CEILING PLAN FOR MORE INFORMATION. D10 REMOVE EXISTING FIRE EXTINGUISHER AND RECESSED CABINET. CONFIRM WITH LANDLORD IF CABINET MATCHES BUILDING STANDARD. IF SO, SALVAGE CABINET FOR REUSE. SEE ARCHITECTURAL PLAN FOR MORE INFORMATION, Dil EXISTING RECESSED SHELVES TO REMAIN AT THIS LOCATION, NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN GOOD CONDITION. 14ai �J II ® AREA NOT IN CONTRACT RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel /� �VTGtBaS41WML_ DATE: \ 03/27/19 DEMOLITION PLAN 0 24' 8' 16: NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE ©1 UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM Al SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. H WALL WITH INSULATION 36% METAL STUDS AT 16 CC.; -� ONE LAYER OF% TYPE "%"GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" SOUND BATT INSULATION EACH SIDE OF WALL ABOVE CEILING. R WALL TO DECK 35/8" METAL STUDS AT 1 C O.C.; ON E LAYER OF 5%' TYPE"X' GYPSUM BOARD EACH SIDE; EXTEND WALLTO UNDERSIDE OF DECK R PARTAL HEIGHT WALL 35/8" METAL STUDS AT 16" O.C.; ONE LAYER OFS% TYPE"%' GYPSUM BOARD EACH SIDE; PROVIDE 1"STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED; R WALLTO DECK WITH INSULATION 3% METAL STUDS AT 16" O.C.; - �- ON E LAYER OF% TYPE "%" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BATT INSULATION INSIDE GENERAL NOTES I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. ARCHITECTURAL LEGEND EXISTING TO REMAIN W? WALL — WALL I� PARTIAL HEIGHT WALL o PARTIAL HEIGHT WALL Rya WINDOW/SIDELIGHT co—w WINDOW/SIDELIGHT ®DOOR AND FRAME RANDSCHEDULE) SttJy/ DOOR AND FRAME (SEE NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS, A01 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE P01 AND VENT PIPING FOR SINKS. EXISTING CASEWORK TO BE REUSED. ARE IN LINE WITH EXISTING WALLS. COORDINATE PLUMING LOCATION WITH EXACT LOCATION OF SINK; VERIFY IN FIELD. REFER TO LANDLORD FOR SOURCE OF HOT NEW BRUSHED ALUMINUM FIRE EXTINGUISHER RECESSED CABINET WATER AND LOCATION ALLOWED IN THIS BUILDING. 0 TO BE PROVIDED AND INSTALLED BY CONTRACTOR, IF EXISTING MATCHES BUILDING STANDARD, REUSE SALVAGED RECESSED PROVIDE COPPER WATER LINE I POLVTUBE IS NOT PERMITTED) CABINETAT THIS LOCATION; CONFIRM WTH LANDLORD, ALL FIRE P02 FOR REFRIGERATOR. CONFIRM LOCATION WITH TENANT, EXTINGUISHERS ARE TO BE PROVIDED BY TENANT AND INSTALLED ACCORDING TO NFPA 10, PROVIDE ALL NECESSARY PLUMBING AND DRAINS FOR P03 RELOCATED DISHWASHER. EXISTING CASEWORK AND O �3 PROVIDE COAT ROD AND SHELF AT THIS LOCATION' SEE DETAIL BE REUSED COORDINATE PLUMBING LOCATIONS FOR ORE HOD CHROME WITH EXACT LOCATION WITH EXACT LOCATION OF DISHWASHER; VERIFY IN FIELD. DOUBLE COAT HOOKS AT MAXIMUM 48" A.FFOR ADA DOUBT COAT MAXIMUM 48 A.F.F.S COMPLIANCE AT THIS LOCATION. REINSTALL SALVAGED CABINETS AND COUNTER FROM THIS ROOM AD4 AS SHOWN, DESIGN INTENT IS FOR ALL EXISTING FINISHES TO REMAIN; CLEAN AND REPAIR AS REQUIRED. REINSTALL SALVAGED CASEWORK INCLUDING ALL CABINETS, A06 COUNTERTOP/BACKPLASH, SINK, FAUCET HARDWARE AND DISHWASHER AS SHOWN. DESIGN INTENT IS FOR CASEWORK TO BE IN SAME CONFIGURATION AS EXISTING AND FOR ALL FINISHES TO REMAIN; CLEAN AND REPAIR AS REQUIRED. REINSTALL SALVAGED CASEWORK INCLUDING BASE CABINETS, A06 COUNTERTOP AND BAR TOP. DESIGN INTENT IS FOR ISLAND TO BE IN SAME CONFIGURATION AS EXISTING AND FOR ALL FINISHES TO REMAIN; CLEAN AND REPAIR AS REQUIRED. VERIFY EXISTING PARTIAL HEIGHT WALL IN FIELD AND PROVIDE NEW BELOW RELOCATED BAR TOP. HEIGHT AND LENGTH OF PARTIAL HEIGHT WALL TO MATCH EXISTING; VERIFY IN FIELD. AO] CONFI RM THAT EXISTING WALL MATCHES WALL TYPE W4. IF NOT, ALTER WALL AS REQUIRED SO THAT CONSTRUCTION MATCHES WALL TYPE W4. A08 CONFI RM THAT EXISTING WALL EXTENDS TO DECK; IF NOT, ALTER CONSTRUCTION AS REQUIRED. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR A09 TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. PROVIDE NEW 24" DEEP SOLID SURFACE COUNTER AT 42"ALL AS A10 SHOWN. SUPPORT COUNTER AS REQUIRED WITH CENTERLINE BRACKET'S FRONT MOUNTING PLUS BRACKET ATTACHED TO METAL STUDS WTH WOOD BLOCKING AND DRYWALL INSTALLED OVER VERTICAL SUPPORT. CASEWORK CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR TO INSTALLATION OF DRYWALL. COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL INSTALLATION AS NEEDED. SEE FINISH PLAN FOR MORE INFORMATION. PROVIDE NEW TRANSOM WINDOW TO MATCH FRAME TYPE F3.SEE A11 DOOR SCHEDULE FOR MORE INFORMATION. DRYWALL TO DECK ON EXTERIOR WALL AS REQUIRED PER OEXTEND Al2 EXPOSED CEILING IN THIS AREA. ® AREA NOT IN CONTRACT ARCHITECTURAL PLAN IN AREA OF WORK 0 2' 4' 816' ' ❑ so N �pO U N V O c �n Z ^ '� o = M P O O Q L W OM V O C UC THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOT TO BE ISED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUTTHE WRITTEN CONSENT OF SCHOTTDESIGN. 04 C) O Z W�— A/ i% W J LLJ I_ moor &I tN 0:� U Illaaaa� UU�Qo F LU G Z QL W `/) Z Q z ISSUE DATE DESCRIPTION 02.21.19 REVIEW SET REVISIONS ARK DATE DB DESCRIPTION PROJECT NUMBER 2019.008 PROD. MGR DRAWN BY AS SO 4TH FLOOR DEMOLITION PLAN/ ARCHITECTURAL FLOOR PLAN A111