Loading...
HomeMy WebLinkAboutA50-4GENERAL CEILING PLAN NOTES THE FOLLOWING GENERAL NOTES ARE APPLICABLE THROUGHOUT THESE CONSTRUCTION DRAWINGS. A. GYPSUM BOARD FINISH LEVELS: FINISH PANELS TO LEVELS INDICATED BELOW AND ACCORDING TO ASTM C 840: LEVEL 4: AT PANEL SURFACES THAT WILL BE EXPOSED TO VIEW UNLESS OTHERWISE INDICATED. LEVEL 4 @ ALL WALLS LEVEL 5 @ ALL CEILINGS NOTES: 1. LIGHT FIXTURES SHOWN ON FLOOR PLANS AND LIGHT FIXTURE SCHEDULE ARE FOR LAYOUT PURPOSES ONLY. 2. REFERENCE MEP DRAWINGS AND ALL ELECTRONIC CONSULTANT DRAWINGS FOR ALL SPECIFICATIONS, MOUNTING HEIGHTS, CIRCUITING, WITCHING, PANEL LAYOUTS, ETC. 3. CONTRACTOR TO PERFORM THEIR OWN TAKE-OFFS. 1 A50-6 EQEQ EQEQ EQEQ 3' - 4 3/4"2' - 10 5/8" 1' - 9" 1' - 5" 2' - 2" 1' - 5" EQ EQ1' - 10"1' - 3" EQ EQ 1' - 9 5/8"4' - 5 3/4" 3' - 8" 2' - 1 1/8" 3' - 10" 4' - 10" 3' - 5" EQEQEQ EQ EQ 3' - 0"6' - 0" 6' - 0" 3' - 0" 3' - 6"13' - 0" 3' - 6" 4' - 1"6' - 2" 6' - 2" 3' - 6" EQ EQ ? A2 A2 A2 A2 A2 A2 A2 A2A2 A2 A2 A1 A1 A1 A1A1 A1 A1 A1 A1 A1 A1 DF1 EF1 A2 E EE 3' - 6"5' - 4"3' - 6" 3' - 2"3' - 10" 3' - 2" 1' - 10"BEDROOM 1 102 LIFT 106 ENTRY HALL 101 WIC 103 LAUNDRY 105 MECH 104 GARAGE 107 B B WALL MOUNT SHADE VALENCE WALL MOUNT SHADE VALENCE A2 A2 3' - 5 1/2" 1' - 8" 2' - 11" 12' - 1"10" 1 A50-6 4' - 4 3/8" 4' - 4 3/8" 4' - 1" 2' - 6" 2' - 0"3' - 2" 2' - 0" 1' - 11" 3' - 3" 1' - 7" 5' - 3" 2' - 0" EQEQ7' - 1 1/2"3' - 7 1/2"7' - 10" EQ EQ 2' - 7 1/2"4' - 7" 5' - 8" 3' - 8" 3' - 2"15' - 1 1/2"2' - 6" ?? A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A2 A2 P1 P1 P1 P1 P1 P1 P1 EF1 A1 A1 A1 DF2 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 B3B B B B B EQEQ EQ EQ EQEQ 4' - 7 7/8"4' - 9" 4' - 9" 1' - 9" SHADE VALENCE SHADE VALENCE SHADE VALENCE DF3 3' - 10" 3' - 2" 2' - 4 1/8"3' - 2" 3' - 6" 3' - 2" 2' - 10 7/8" 3 5/8" 2' - 0" EQ B 1' - 6"1' - 6" 5' - 9 3/4" 1' - 6"5' - 0 1/4" 5' - 0 1/4" 3' - 7" 2' - 0 1/2"2' - 0" 3' - 5 1/2" 1' - 8" 1' - 8" 1 A50-6 EQEQ 1' - 7 1/2"1' - 9 1/2" 3' - 1 1/2" 3' - 0"2' - 0 1/2"1' - 11 1/2" 1' - 8" 3' - 7" 1' - 9 1/2" EQEQ 1' - 2"CL3' - 0"7' - 11" 3' - 0" 2' - 10 1/2" 7' - 7 1/2" 3' - 0" 2' - 1 1/2"1' - 10"3' - 9" 3' - 9" 2' - 0" 1' - 2"2' - 11" 3' - 1" 5' - 7"5' - 9" EQ EQ EQEQ EQ EQ EQ EQ 2' - 6 3/4"2' - 1 3/4" EQEQ 11" 2' - 8" 2' - 3" 1' - 9 1/2" 1' - 2"4' - 1 1/2" 3' - 9 1/2" 1' - 9 1/2" 1' - 8 1/2"1' - 9" 3' - 4" 3' - 4" 1' - 1 1/8"9' - 2 7/8" 1' - 8 1/2" 2' - 0 1/2" 8' - 3" 2' - 4" EQ EQ3' - 2"2' - 10 7/8" 3' - 2" 2' - 11 1/8"EQEQ 1' - 9 1/4"1' - 8 3/4" EQEQ ? ? A1 A1 A1 A1 EF2 A1 A1 A1 A1 A1 A1 A2A2 A2 A2 A1 A1 A1 A2 A2 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A2 B3 MASTER BEDROOM 305 MASTER BATH 306 MASTER CLOSET 304 LIFT 307 HALL 300 BATH 302 WIC 303 BEDROOM 2 301 SHADE VALENCE SHADE VALENCE SHADE VALENCE SHADE VALENCE EQEQ 2' - 5" 4' - 1" A1 2' - 0 1/2"2' - 11" 2' - 5 1/2"1 A50-6 EQMECHANICAL 400 GUEST BATH 402 WIC 401 BEDROOM 3 403 LIFT 404 ROOF DECK 405 HALL 407 2' - 9"5' - 3 1/2" 2' - 8"2' - 8"9' - 3 1/2" 2' - 8" 2' - 0" 2' - 7" 2' - 0" 4' - 1 1/2"EQEQ EQ EQ EQ EQ 3' - 5"3' - 6" EQEQ 3' - 6" SHADE VALENCE A1 A1 A1 A1 A2A2 A2 A1 A1 B3 A1 A1 DF6 U U EF1 A2 A2 A2 3 A50-3 7' - 2" 4' - 6"7' - 2 1/2"4' - 6" 2' - 4" B2 B2 1' - 8"8" 1' - 2"EQEQ EQ EQ EQ EQ EQ EQ EQEQ R TAR19900111 A CRHCETI STATE OF BTTOCS No. TSIGER ERED NETRA EP K SNI I A N ADNI ARCHITECT BLACKLINE 1 N MERIDIAN ST, SUITE 400 INDIANAPOLIS, INDIANA 46204 BLACKLINESTUDIO.NET 317.803.7900 M.E.P. GENESIS ENGINEERING GROUP 91 SOUTH MAIN STREET, SUITE 200 ZIONSVILLE, IN 46077 GENESIS-ENGINEERING.COM 317.927.8307 STRUCTURAL SCHWARZ ENGINEERING GROUP WWW.SCHWARZINC.COM 317.850.5133 - - ALL INFORMATION CONTAINED IN THIS DOCUMENT IS CONSIDERED TO BE BOTH CONFIDENTIAL AND PROPRIETARY INTELLECTUAL PROPERTY OF BLACKLINE STUDIO AND SHALL NOT BE COPIED, REPRODUCED, DISTRIBUTED OR ASSIGNED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT OF BLACKLINE STUDIO. UNAUTHORIZED USE OF THESE DOCUMENTS IS NOT PERMITTED. © 2017 BLACKLINE STUDIO CERTIFICATION: CHECKED:DRAWN: S:\_Projects\Monon & Main - Carmel\002 Drawings\005 Revit\103018 _ Monon & Main - A18 - Townhome Interiors.rvt 10/30/2018 2:13:41 PM A50-4COPYRIGHT 2018 REFLECTED CEILING PLANSMonon & Main BrownstonesMonon & Main St., Carmel INCheckerAuthor CDs -PERMIT SET 10/30/2018 Lot 50 -BOYD RESIDENCE#REVISION Date LIGHT FIXTURE SCHEDULE - Lot 50 MARK FIXTURE DESCRIPTION RECESSED DOWNLIGHTS, CEILING & WALL MOUNTED FIXTURES A1 4" Premium Deep Cone A2 4" Standard Reflector B Downlight - 2" Surface Gimbal B2 4" Designer Internal Adj. B3 4" Standard Adj. E Exterior Rated 2" recessed can light EF1 Exhaust Fan EF2 WhisperRecessed LED - Design Solution for Fan/Light Combinations, 80 CFM U 48" LINEAR LED STRIP LIGHT DECORATIVE FIXTURES DF1 Decorative Light Fixture by Others DF2 Decorative Light Fixture by Others DF3 Wall mounted DF6 Decorative Light Fixture by Others CASEWORK MOUNTED FIXTURES P1 Undercabinet Puck Light 1/4" = 1'-0" 1ST FLOOR RCP - LOT 501 1/4" = 1'-0" 2ND FLOOR RCP - LOT 502 1/4" = 1'-0" 3RD FLOOR RCP - LOT 503 1/4" = 1'-0" 4TH FLOOR RCP - LOT 504 03/26/19 Mike Sheeks