HomeMy WebLinkAboutLighting PlanF.F.E. = 755.70 (NAVD 88 DATUM)N 00°00'00" W 234.67'N 90°00'00" W 376.00'S 03°04'59" E 243.00'N 90°00'00" E 214.95' A/C A/C E G E PROPOSED GYM & LEARNING CENTER 13,000± S.F. F.F.E. = 755.70 (NAVD 88 DATUM) F.F.E. = 755.70 (NAVD 88 DATUM) N 86°54'50" E 148.20' 2% MAX 2% MAX EXISTING SCHOOL BUILDING EProposed GateS4-IL MH: 25 S4 MH: 25 S4 MH: 25 0.0 0.1 0.1 0.2 0.3 0.6 0.9 1.5 1.5 0.9 0.5 0.1 0.1 0.2 0.4 0.7 1.2 2.0 2.6 2.5 2.1 2.4 1.6 0.1 0.2 0.4 1.0 1.9 2.2 2.6 2.8 2.8 2.6 2.4 1.9 0.2 0.5 1.0 1.5 2.8 2.5 0.3 1.1 2.3 2.6 3.1 2.6 0.4 1.1 2.6 2.7 3.1 2.6 0.3 0.7 1.5 2.2 3.6 2.8 0.3 0.6 0.9 2.2 3.9 3.1 0.3 0.7 1.3 2.1 3.6 2.8 0.4 1.1 2.5 2.6 3.1 2.4 0.3 1.1 2.5 2.6 2.9 2.2 0.3 0.6 1.1 1.6 2.7 1.9 0.1 0.3 0.4 1.1 1.9 1.5 0.1 0.1 0.2 0.4 0.8 0.8 0.0 0.0 0.1 0.1 0.2 0.2 0.0 0.0 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.4 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.00.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 Luminaire Schedule Symbol Qty Label Arrangement Lum. Lumens LLF Lum. Watts Description 2 S4 SINGLE 18858 0.900 154.1 XALM-FT-LED-SS-40 1 S4-IL SINGLE 14362 0.900 154.1 XALM-FT-LED-SS-40-IL Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min Parking Lot Illuminance Fc 1.40 3.9 0.0 N.A. N.A. Property Line Illuminance Fc 0.05 0.4 0.0 N.A. N.A. SHEETSOF DRAWN BY: ISSUE DATE SHEET SIZE STAMP REVISIONS NO CB13435-SITE-4 DRAWING NUMBER: 5855 KOPETSKY DR | INDIANAPOLIS, IN 46217 317-780-8350 | WWW.CBMCINC.COM BYDATE SCALE:Based on the information provided, all dimensions and luminaire locations shown represent recommended positions. The engineer and/or architect must determine applicability of the layout to existing or future field conditions. This lighting pattern represents illumination levels calculated from laboratory data taken under controlled conditions in accordance with Illuminating Engineering Society approved methods. Actual performance of any manufacturer's luminaire may vary due to variation in electrical voltage, tolerance in lamps, and other variable field conditions. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROPRIETARY TO CBMC LIGHTING SOLUTIONS. THIS DOCUMENT IS PREPARED FOR A SPECIFIC SITE AND INCORPORATES CALCULATIONS BASED ON DATA AVAILABLE FROM THE CLIENT AT THIS TIME. BY ACCEPTING AND USING THIS DOCUMENT, THE RECIPIENT AGREES TO PROTECT ITS CONTENTS FROM FURTHER DISSEMINATION, (OTHER THAN THAT WITHIN THE ORGANIZATION NECESSARY TO EVALUATE SUCH SPECIFICATION) WITHOUT THE WRITTEN PERMISSION OF CBMC LIGHTING SOLUTIONS. THE CONTENTS OF THIS DOCUMENT ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF CBMC LIGHTING SOLUTIONS. Copyright © 2018 CBMC Lighting Solutions All rights reserved. PHOTOMETRIC NOTES MOUNTING HEIGHT 25' LIGHT LOSS FACTOR 0.90 REFLECTANCES -- FOOTCANDLES CALCULATED AT @ GRADE SJM8/16/18ARCH Full Bleed D (24.00 X 36.00 Inches) 1" = 20' - - SITE LAYOUTPlay School at Legacy Sport Court - Exp ** Site Photometric ** Plan is a CBMC Standard and must contact Matt Earles or Rose Simpson @ CBMC for pricing. Tel. 317-780-8350 03/29/19