HomeMy WebLinkAboutC5.0.Utility PlanF.F.E. = 755.70
(NAVD 88 DATUM)
Equality Blvd.
A/C A/C
E
G
E
PROPOSED GYM &
LEARNING CENTER
13,000± S.F.
F.F.E. = 755.70
(NAVD 88 DATUM)
F.F.E. = 755.70
(NAVD 88 DATUM)
EXISTING SCHOOL
BUILDING
E
EXISTING SANITARY LATERALEX. 6" SAN. LATERALEXISTING C.O.
CO TYPE III
INV=741.62
RESTORE SWALE TO EXISTING
CONDITION WHEN CONSTRUCTION
OF LATERAL IS COMPLETE
MIN. 3' COVER
INV=742.0±
EXISTING C.O.
INV. = 749.7±
CO TYPE III
INV=751.1
CO TYPE I
INV=752.2
CO TYPE III
INV=749.5
NEW D.I. SLEEVE FOR EX.
SCHOOL BLDG. FDC LINE
CONNECT NEW 6" PVC C900
PRIVATE FIRE SERVICE LINE
TO EX. FIRE LINE
PROPOSED 3Ø, 120/208v ELEC.
TRANSFORMER PER DUKE
ENERGY SPECS.
EX. PRIMARY ELEC. SERVICE TO
BE REUSED FOR NEW
TRANSFORMER6" HYDRANT LINEWET TAP EX. 6"
FIRE LINE w/ GATE
VALVE FOR NEW 6"
PVC C900 PRIVATE
FIRE SERVICE LINE
PIV
4" F.D.C. LINE PER CARMEL
FIRE/UTILITIES STDS.
NEW FIRE HYDRANT
DS
FDC
EXISTING ELEC. CT CABINET
EXISTING FIRE HYDRANT
EXISTING GAS SERVICE TO BE RELOCATED
(T.B.D. BY VECTREN)
UX
UX
UX
UX
18
UX
UX
L
L
L
L
EXISTING FIRE SERVICE LINE TO
BE LOWERED DUE TO NEW
STORM SEWER INSTALLATION
(CONTRACTOR TO FIELD VERIFY
PRIOR TO COMMENCING WITH
CONSTRUCTION)
EX. PRIMARY ELECTRIC LINE
EX. SCHOOL
F.D.C.
PROP. ELEC. METER PER
DUKE ENERGY STDS.
SE
SE
SE
SE
EX. 8" SANITARY MAIN
BOA
HY1
HY1
EXISTING SANITARY MANHOLE
T.C. = 757.45
INV. = 739.24± (EX. 8" PVC - W)
INV. = 739.29± (EX. 8" PVC - E)
RELOCATE
EXISTING TELECOM
RELOCATE
EXISTING TELECOM
NEW 6" FIRE SERVICE LINE NEW 6" FIRE SERVICE LINE6" GATE VALVE
ABANDON EXISTING WATER LINE WITH
RESTRAINED PLUG/KICKER PER
CARMEL WATER STDS.
ABANDON EXISTING WATER LINE PER
CARMEL WATER STDS.
INSTALL NEW 6-INCH TEE, GATE
VALVE, & TEMPORARY BLOW-OFF
ASSEMBLY FOR TESTING/SAMPLING
EXISTING C.O.
T.C. = 752.2±
INV. = 745.45
L1 L1UX
UX
CO TYPE III
INV=746.8±
INSTALL NEW 6" WYE FITTING SDR 26 PVC
INV. = 746.0±
(EXISTING INVERT TO BE FIELD VERIFIED
BEFORE ALTERNATE #1 CAN BE
APPROVED FOR CONSTRUCTION)
UX
SANITARY LATERAL ALTERNATE #1
122± LF OF 6" SDR 35 PVC @ 1.04% MIN.EXISTING 18" RCPEX. 18" STORM INV = 747.8±
(EXISTING INVERT TO BE FIELD VERIFIED BEFORE
ALTERNATE #1 CAN BE APPROVED FOR CONSTRUCTION)
CC
4
4
4
4
PROJECT NUMBER
DRAWING NUMBER
SHEET OF
SCALE:
DATE:
DWN BY:
CHKD. BY:CIVIL SITE GROUP, INC.
GROUP, INC.PROF
E
SS
ION A L E NG INEERIND
IA NA
PE10910647
STATE OF
-o NREG I S TER
E
DBR IA N S CR
O
S
STPS.007
C5.0NOBLESVILLE, INDIANA 4606015575 STONY CREEK WAYTHE PLAY SCHOOL at LEGACY, INC.UTILITY PLANTHE PLAY SCHOOL at LEGACY SPORT COURT14454 COMMUNITY DRIVECARMEL, INDIANA 46033REVISION RECORD
06/22/2018
CONTRACTOR NOTE
NO EARTH DISTURBING ACTIVITY MAY COMMENCE
WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT.
TOPOGRAPHIC & BOUNDARY NOTE
BUILDING NOTE
REFER TO ARCHITECTURAL &
FOUNDATION PLANS FOR ALL
BUILDING DIMENSIONS.
UTILITY LOCATE NOTE
LEGEND:
UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE
THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE
RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT
IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE
DEVELOPER'S RESPONSIBILITY TO RESOLVE WITH THE UTILITY.
EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN
ONE FOOT OR THE PROPOSED RIGHT-OF-WAY LINE.
PLAN NOTES:
UX
18
ISDH NOTES
THE WATER-LINES THROUGHOUT THE
PROJECT SHALL BE INSTALLED WITH
AT LEAST 54-INCHES OF COVER TO
PROVIDE PROTECTION FROM
FREEZING.
WHERE WATER-LINES AND SEWERS
(STORM AND/OR SANITARY) CROSS
AND THE WATER-LINE CANNOT BE
PLACED ABOVE/BELOW THE SEWER
WITH A MINIMUM OF 18-INCHES
VERTICAL CLEARANCE, THE SEWER
MUST BE CONSTRUCTED OF WATER
WORKS GRADE DUCTILE IRON PIPE
WITH MECHANICAL JOINTS WITHIN 10
FEET OF THE WATER-LINE.
SANITARY SEWERS SHOULD HAVE A
MINIMUM OF 2 FEET OF COVER.
A
18 " OF VERTICAL SEPARATION MUST
BE MAINTAINED FOR ALL UTILITY
CROSSINGS.
ALL CONCRETE PIPE JOINTS SHALL
BE CONTINUOUS O-RING RUBBER
GASKET CONFORMING TO ASTM C 443
DEPENDING ON THE CONSTRUCTION SEASON,
MOISTURE CONTENT AND PROPERTIES OF THE
SOILS ON SITE, CHEMICAL MODIFICATIONS
AND/OR LIME STABILIZATION MAY BE REQUIRED.
SEE SHEET C9.0 FOR SPECIFICATIONS.
UTILITY NOTES
1. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO
VERIFY ALL EXISTING UTILITIES AND CONDITIONS
PERTAINING TO THEIR PHASE OF WORK. IT SHALL ALSO BE THE
CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF
THE VARIOUS UTILITIES FOR PROPER STAKE LOCATIONS FOR
EACH UTILITY BEFORE WORK IS STARTED. THE CONTRACTOR
SHALL NOTIFY IN WRITING THE OWNER OR THE ENGINEER OF
ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE
PLANS OR IN THE FIELD BEFORE WORK IS STARTED OR
RESUMED.
2. STANDARD SPECIFICATIONS FOR THE LOCAL GOVERNING
AGENCY SHALL APPLY FOR ALL SANITARY SEWERS, STORM
SEWERS, AND WATER MAINS.
3. ANY PART OF THE SANITARY OR STORM SEWER TRENCHES
RUNNING UNDER PAVED AREAS TO BE BACKFILLED WITH
GRANULAR MATERIAL.
4. ALL WATER SERVICE / FIRE LINES ARE REQUIRED TO HAVE A 60"
MINIMUM COVER OVER TOP OF PIPE. ALL WATER/SANITARY LINE
CROSSINGS MUST MAINTAIN 18" VERTICAL SEPARATION BETWEEN
OUTSIDE OF PIPES PER INDIANA STATE DEPARTMENT OF HEALTH.
5. STERILIZATION OF WATER MAIN SHALL BE IN ACCORDANCE
WITH STATE BOARD OF HEALTH REQUIREMENTS.
(APPLIES TO COMMERCIAL ONLY)
6. CONTRACTOR RESPONSIBLE TO INSTALL ALL UNDERGROUND
CONDUIT PER UTILITY COMPANY'S SPECIFICATIONS.
7. CONTRACTOR RESPONSIBLE FOR RESTORATION TO ALL AREAS
AFFECTED DURING CONSTRUCTION. REFER TO THE
CITY OF LAWRENCE DPW - STANDARDS FOR RESTORATION
REQ'S.
8. CONTRACTOR TO LOCATE ALL EXISTING UTLITIES AT ANY
PROPOSED CROSSING AND PROVIDE EXISTING TOP OF PIPE
ELEVATIONS WITHIN 10 DAYS OF NOTICE TO PROCEED.
PROVIDE CONCRETE CRADLE AS REQUIRED FOR ANY VERTICAL
SEPARATION LESS THAN 18 INCHES.
CATV:
Brighthouse Networks
Jason Kirkman
(317) 632-9077 x291
jason.kirkman@mybrighthouse.com
Telephone:
AT&T
Steve Krebs
(317) 252-4275
SK4986@att.com
Fire Service:
Office of Fire Chief, Fire Station #1
Gary Hoyt
Two Civic Square
Carmel, IN 46032
(317) 571-2600
cellison@carmel.in.gov
UTILITY CONTACTS
Natural Gas:
Vectren Energy
Joanie Clark
(317) 776-5532
jlclark@Vectren.com
Wastewater & Water:
Carmel City Utilities
John Duffy
760 Third Avenue SW
Carmel, IN 46032
(317) 632-9077
Drainage:
Carmel Engineering
Gary Duncan or John Thomas
1 Civic Square
Carmel, IN 46032
(317) 571-2441
gduncan@carmel.in.gov
Streets:
Carmel Street Department
Dave Klingensmith
3400 West 131st Street
Westfield, IN 46074
(317) 733-2001
Electric:
Duke Energy
Shirley Hunter
16475 Southpark Dr.
Westfield, IN 46074
(317) 896-6721
shirley.hunter@duke-energy.com
G
E
EXISTING CONDITIONS NOTE
CONTRACTOR TO VERIFY ALL EXISTING
CONDITIONS, INCLUDING UTILITIES AND
DRAINAGE INFRASTRUCTURE BEFORE
COMMENCING WITH CONSTRUCTION.
CONTRACTOR TO NOTIFY ENGINEER OF
ANY DISCREPANCIES.
FIRE PROTECTION NOTES
Prior to the Issuance of any Building Permits the stone base layers for all Streets, Drives and
Parking Lots to be installed and all Water Mains and Hydrants for the Site Development must be
installed per Approved Specifications and made Serviceable.
Prior to issuance of any building permits the stone sub-base shall be graded and compacted in
compliance with fire department specifications. A proof roll shall be witnessed by the fire
department or their designee.
The Carmel Fire Department shall be notified 24 hours prior to the inspection. 317-571-2600.
ENGINEER:
OWNER/DEVELOPER:
SURVEYOR:
ARCHITECT:
UTILITY VALVE/CASTING NOTE
IRRIGATION NOTE
L
FDC
PIV
B.O.A IS TEMPORARY ONLY TO BE USED FOR TESTING/SAMPLES & WILL
NEED TO BE ABANDONED WHEN TIE OVER TO NEW MAIN HAPPENS
BOA
SITE LIGHTING NOTE
DRIVEWAY GRADING & UTILITY NOTE
CONTRACTOR TO VERIFY THE DEPTH AND LOCATION OF ALL
EXISTING UTILITIES ALONG EQUALITY BLVD. PRIOR TO COMMENCING
CONSTRUCTION. PROPOSED DRIVEWAY CUTS MAY REQUIRE
EXISTING UTILITY FACILITIES TO BE LOWERED AND/OR RELOCATED
IN ORDER TO MAINTAIN MINIMUM STANDARDS OF COVER / VERTICAL
SEPARATION, INCLUDING WATER, GAS, POWER, AND TELECOM.
DS
EXISTING UTILITIES NOTES
REFER TO THE 'EXISTING CONDITIONS & DEMOLITION PLAN' FOR
INFORMATION ON WHICH UTILITIES TO REMOVE AND/OR RELOCATE PRIOR
TO COMMENCING WITH ANY NEW CONSTRUCTION.
GAS SERVICE - TO BE DETERMINED BY VECTREN. RELOCATION NOT
SHOWN PENDING AN 811 LOCATE.
TELECOM SERVICE - RELOCATION NOT SHOWN PENDING AN 811 LOCATE.
E
SE
HY1
L1
4
4
04/01/19