HomeMy WebLinkAbout18662M-M1MECHANICAL 5YMBOLS ® (Sr NEIN SUPPLY DIFFUSER IRS) NBN RETURN AIR GRILLE ® EXHAUST GRILLE/FAN ® REMOTE TEMPERATURE SENSOR 0 THERMOSTAT, MOUNTED AT 45' AFF ® DUCT -MOUNTED SMOKE DETECTOR NEW DUCTWORK 52"x14" SIZE OF RECTANGULAR DUCT 611() SIZE OF ROUND DUCT FLEXIBLE DUG6NORK FLOOR FLAN NOTE DESIGNATION S.A. SUPPLY AIR R.A. RETURN AIR EXH. EXHAUST AIR TRANSITION IN DUCT SIZE Tg=a= I[}y ELBOW WITH TURNING VANES MANUAL VOLUME DAMPER -� MANUAL VOLUME DAMPER SUPPLY AIR DUCT UP/DCJWN RETURN AIR DUCT UP/DOWN ® EXHAUST AIR DUCT UP/DOWN SUP CHANGE IN ELEVATION UP (UP) DOWN (DN) IN DIRECTION OF FLOW III SCHEDULED MECHANICAL EQUIPMENT SHORT RADIUS ADJUSTABLE ELBOW ROOF TRUSS 12"C1) ROUND 120 22"CD MANUAL DAMPER "/ g IGHTING TRACK MOUNT DUCT A5 1 AS TRUSS OR LIG TRACK WILL AL -LC 16'O SUPPLY AIR DL MIN. 9 TO FLOOR ECCENTRIC TRANSITION TO MAINTAIN DUCT HEIGHT DINING ROOM DIFFUSER DETAIL -SPIN IN WITH VOLUME DAMPER ROUND FLEX —4 DUCT. 6' MAX. LENGTH O MOUNTING LOCATION FOR DUGTdOUNTEDSMOKE DETECTOR. ,• MECHANICAL FLOOR PLAN \V/ 20 LOCATION OF MANUAL PULL STATION. INSTALL PER THE MANFUACTURERS REQUIREMENTS. SCALE: 1/4"=l'-O" OS LOCATION OF RTU THERMOSTATS. GC TO LABEL EACH THERMOSTAT. MECHANICAL GENERAL NOTES: 40 LOCATION OF RTU TEMPERATURE SENSORS MOUNTED l'-O" AFF DIFFUSER DETAIL 5CA1i NONE 05 MAINTAIN A MIN, OF 10-0 CLEARANCE CLEARANCE BETWEEN ALL OUTDOOR AIR INTAKES a EXIT FLUE OUTLETS, 60 EXHAUST HOOD PROVIDED BY OTHERS. INSTALLED BY THIS CONTRACTOR PER THE MANUFACTURERS INSTRUCTIONS. 2. O TRANSITION AND CONNECT b"x9" GREASE DUCT TO EXHAUST HOOD AS SHOWN. ROUTE DUCT UP AND CONNECT TO EXHAUST FAN. OFFSET AS NECESSARY TO MI55 ROOF STRUCTURE, AND TO MAINTAIN 10-0 CLEARANCE CLEARANCE THE BUILDING HVAG SYSTEM SHALL BE BALANCED BY AN INDEPENDENT NEEB CERTIFIED BALANCING CONTRACTOR HIRED BY FROM ALL OUTDOOR AIR INTAKES, AND B-O" FROM PARAPET WALLS. ALL GREASE DUCT IS TO BE INSTALLED THE OMER. CONTACT Jason Neises - National TAB aC855-682-6822 x 105 WITH DUCT WRAP AS DETAILED AND PER THE MANUFACTURERS REQUIREMENTS. 5, OTRANSITION AND CONNECT 15"Iti GREASE DUCT TO 12"Iti COLLARS ON EXHAUST HOODS. ROUTE DUCT UP AND CONNECT TO EXHAUST FAN. OFFSET AS NECESSARY TO MISS ROOF STRUCTURE. AND TO MAINTAIN 10-0 CLEARANCE CLEARANCE FROM ALL OUTDOOR AIR INTAKES. AND B'-O" FROM PARAPET WALLS. REFER TO DETAIL ON SHEET M2. ALL GREASE DUCT IS TO BE INSTALLED WITH DUCT WRAP AND ACCESS 4. DOORS AS DETAILED AND PER THE MANUFACTURERS REQUIREMENTS. OUTDOOR AIR CALCULATIONS O TRANSITION AND CONNECT MAKE-UP AIR DUCT TO EXHAUST HOOD SUPPLY PLENUM PER THE MANUFACTURERS 5' REQUIREMENTS. SEE SHEET MS FOR CONNECTION SIZE AND SUPPLY GFM. 70 ROUTE 16"Iti MAKE UP AIR SUPPLY DUCT DOWN FROM MUA-1. TRANSITION AND CONNECT TO 16"Iti SUPPLY DUCT. 6 eeege atmnr Ar�nnueer zoneair dmnwrac h !m1engu::' almnw raem a.Ra,et arum'"g de iwwn Zone VERIFY THE EXACT SIZE AND LOCATION OF STRUCTURE BEFORE IN5TALLING DUCTWORK. UNIT Area(dri OCCURANCYCUSSIFICATON Oaupsnt UgisM1y NllOW sqR Ixy"nor alrlbw rate wwe s be m oNWa Popr" z � 1 amrenn xmow Nml amow(ctml 11 RETURN AIR DUCT LOCATED BETWEEN ROOF TRUBBEB. OPEN END OF DUCTWORK TURNED UP TOWARD STRUCTURE WITH D f[z1 A MINIMUM 14' CLEARANCE TO DECK. T. 545 Dining moms 70 7.5 0.18 555 0.8 1 12 SUPPORT EXHAUST FAN FROM STRUCTURE AS REQUIRED BY THE MANUFACTURER. RTU-1 8. 175 Corridors O 1 O 1 0.06 1 10 0.8 15 13 ROUTE RETURN AIR DUCT THROUGH OR BETWEEN ROOF TRUSSES. Total 491 7q MOUNT CONDENSING UNIT ON ROOF AS DETAILED AND AS REQUIRED BY THE MANUFACTURER. CONNECT REFRIGERANT PIPING AS REQUIRED BY THE MANUFACTURER. SEE ARCHTECTURAL PLANS FOR MOUNTING DETAIL. 545 Dining rooms 10 1.5 0.15 585 0.5 4T9 RTU-2 15 PROVIDE LOCKING QUADRANT DAMPER AND ROUND TO SQUARE TRANSITION FOR RETURN GRILL CONNECTION. ITS Corridors O 1 O 1 0.06 1 10 0.5 15 16 ROUTE 10"CD EXHAUST DUCT UP THROUGH ROOF TO ROOF GAP. MAINTAIN 10'-0" CLEARANCE TO ALL OUTDOOR AIR INTAKES. Total 491 1T TRANSITION AND CONNECT AIR CONDITIONING DUCT TO EXHAUST HOOD Ai SUPPLY PLENUM PER THE MANUFACTURERS REQUIREMENTS. BEE SHEET MS FOR CONNECTION SIZE AND SUPPLY GFM. 51 Kitchens (cooking) O O O 0.1 O 0.5 O 18 INSTALL CAPTIVE AIRE W E WINDEAND EXTENSION FOR KEF-1 AND KEF-2 PROVIDED BY KITCHEN EQUIPMENT SUPPLIER. RTU-5 50 Office spaces 5 5 0.06 4 Oh 5 19 COORDINATE DUCT DROP BETWEEN STRUCTURAL TRUSSES WITH SIZES SHOWN. 142 Corridors O O 1 0.06 1 9 0.6 11 ®O TRANSITION AND CONNECT 10"m ALUMINUM DUCT TO CONDENSATE HOOD. ROUTE DUCT UP AND CONNECT TO EXHAUST FAN. OFFSET A5 NECESSARY TC RELEASED FOR CONSTRUCTION Total 16 MI55 ROOF STRUCTURE, AND TO MAINTAIN 10 -Or CLEARANCE FROM ALL OUTDOOR AIR INTAKES AND 5FROM PARAPET WALLS. Subject to compliance with all regulations of State and Local Codes City of Camel dVT�lmnrJnlal� DATE: \ 04/03/19 COORDINATE ALL WORK WITH OTHER TRADES AND EXISTING CONDITIONS AS REQUIRED TO PROPERLY INSTALL ALL SYSTEMS AS INTENDED, WITHIN THE CONFINES OF THE SPACES AVAILABLE, AND WITHOUT INTERFERENCES. 714I5 CONTRACTOR SHALL PERFORM ALL WORK INDICATED AND/OR AS REQUIRED FOR THE PROPER INSTALLATION AND OPERATION OF THE MECHANICAL SYSTEMS. REFER TO ARGHfTEGTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF DIFFUSERS. INSTALL ALL DUCT, PIPE, ETC.. AS HIGH AS POSSIBLE. DUCT SIZES SHOWN ARE ACTUAL SHEET METAL SIZES AND INCLUDE A 1/2 INCH ALLOWANCE FOR DUCT LINER WHERE APPLICABLE. PROVIDE FLEXIBLE CONNECTION BETWEEN DUCTWORK AND ROOFTOP UNITS, EXHAUST FANS, AND OTHER MOTORIZED EQUIPMENT. NO DUCT SHALL BE ROUTED OVER THE TOP OF ELECTRICAL PANELS. ALL EXPOSED DUCT WORK SHALL BE PAINTED. REFER TO ARGHTEGTURAL PLANS FOR DETAILS. an ni I sense by the Desionor and is ended Is red on he body only III, to the emotional Works copyright III A, or an III draving"peciamons at We conodriely kind contents work 11 he idesq,lonamer Any wri use or boosted A needed maysid are northeast a.., A n harder a only ENGINEERS INCORPORATED 5720 Reeder S hawn as, Ks. 66203 (913)262-1772 Z W N NO 1� NW w um �a z C0 00 z U- J LI.I z oa ti U rn 11/7/2018 as ra1a41o70 % STnre OF F, _ PN4 '., `121 11111 WINTER ARCHITECTS 1024 EAST FIRST STREET WICHITA, KS. 67214 PH. 316-267-7142 DATE SHEETNO. M1