Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18662P-P2
PROVIDE RI5E IN PIPE IF fal TO GET CONFIGURATION OF DIRT LEG SHOWN � FROM UNIT DRAIN PAN GLEANOUT WITH PIPE GAP (TYPIGAU MIN. DRAIN LINE SLOPE AS REQUIRED TO DRAIN CONNECTION. RUN ON ROOF. 6A5 METER (1004 GFH ® 295i.) TERMINATE AT GUTTERS OR ROOF DRAIN. SECURE END OF PIPE IN/ NYLON 5TRAR � I CONDENSATE DRAIN DETAIL 1GAS FIRED EQUIPMENT UNION 6A5 SHUT-OFF VALVE DIRT LBO (SAME SIZE AS GAS PIPE - 6" LENGTH) GAS CONNECTION DETAIL 5GALE: NONE ROOF HYDRANT DETAIL L SCALE: NONE GAS REGULATOR PROVIDE RISE IN PIPE IF FillTOGET GONFI6URA1ON OF DIRT LEG SHOWN 6A5 FIRED EQUIPMENTT 7 GAS // SHUT-OFF VALVE UNION DIRT LEG (SAME SIZE AS 6A5 PIPE - b" LENGTH) GAS CONNECTION WITH REG, DETAIL SCALE: NONE 1" x 1/5" GALVANIZED IRON STRAP. DO NOT GLAMP PIPE PIPE TIGHT NON -CORROSIVE 1/4" UNI-STRUT 1-5/5" GALVANIZED NUTS AND BOLTS. STEEL CHANNEL ROOF INSULATION ROOF DECK EASIWASH CABINET MIFAB C510 RUBBER SUPPORT WITH 1-5/5" GALVANIZED STEEL CHANNEL RUBBER ROOF PIPE SUPPORT DETAIL 50ALE: NONE PEX PIPING REQUIREMENT5 PIPE 51ZE5 GIVEN ON THE DRAWINGS ARE NOMINAL COPPER PIPE SIZE. IF PEX PIPING 15 USED, INCREASE PEX PIPING ONE SIZE ABOVE LISTED SIZES AS REQUIRED TO EQUAL OR EXCEED COPPER PIPE INSIDE DIAMETER. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City d Camel dVT� lmnrJnelJS� DATE: \\ 04/03/19 C.o4 L1 r---- — MEN n i I 1 WOMEN REEZER WC I 1 Y1 Ul i / HALL I /9 1 yy _J u I 5/4 2 I (160 —Cl LERin { rl---Fw 1— ,1�Pw— A ! I I STORAGE I f r I r II �� [Ee[Ee :L •hN 1:..�i�R I�■ 11 1� ��j=� Lily a a3/4' Miami I ME'1Y HIS I El 1 11 �In I -.1Ld1 rl,i�� �I DISHWARE 1 y" DOMESTIC T' FIRE SERVICE SEES MATEIL. CIVIL BEE CI „ PLUMBIN SEE CIVIL PLAN FOR PLAN FOR CONTINUATION. SCALE: 1/4" = 1'-O" CONTINUATION. PLUMBING PLAN NOTES: OCOORDINATE WITH GAS COMPANY FOR INSTALLATION OF A METER WITH CAPACITY FOR 1004 GFH ® 2 951. ROUTE PIPING UP IN51DE THE EXTERIOR WALL AND PENETRATE THE PARAPET WALL ONTO ROOF. ALL JOINTS ARE TO BE WELDED OR USE FITTINGS APPROVED FOR CONGEALED USE. VERIFY ALL EQUIPMENT GAS CAPACITIES AND OPERATING PRESSURES PRIOR TO INSTALLATION OF ANY PIPING. OCONNECT OAS PIPING TO EQUIPMENT AS DETAILED AND PER THE MANUFACTURERS INSTRUCTIONS. O 3/" 6A5 (2p5i) WITH SHUT-OFF VALVE AND PRESSURE REGULATOR LOCATED BEHIND FRYER. (3/4 MAXITROL 325-51., 220 GFH, 2051. INLET PRE55URE WITH TW.G. OUTLET PRESSURE). PROVIDE WITH AN51 Z21.50/C5A 6.66 LISTED VENT LIMITING DEVICE. 1" PIPE TO FRYER MANIFOLD. 4O %' 6A5 (2051.) WITH SHUT-OFF VALVE AND PRESSURE REGULATOR ON ROOF (5/" MAXITROL #325-SL, 454 GFH, 2p5i. INLET PRESSURE WITH T' W.G. OUTLET PRESSURE). CONNECT TO ROOF TOP UNITS A5 DETAILED AND A5 REQUIRED. SO SUPPORT GAS PIPING ON ROOF AS DETAILED. O 34' 6A5 DOWN THROUGH ROOF AND GEILIN6 TO WATER HEATER. CONNECT PER THE MANUFACTURERS REQUIREMENTS. OGAS PIPING DOWN THRU ROOF TO AUTOMATIC GAS SHUT OFF VALVE IN AN ACCESSIBLE LOCATION ABOVE GEI1-IN6 AS REQUIRED. OPROVIDE Yl" FILTERED CW TO ICE MACHINE WITH SHUT-OFF VALVE. PROVIDE WAli 5D-B BFP PRIOR TO CONNECTION TO WATER FILLER. 9O PROVIDE 1" CONDENSATE DRAIN FOR RN AS DETAILED. 10 CONNECT TO 1-Y' DOMESTIC WATER SERVICE AS REQUIRED. SEE CIVIL PLAN FOR CONTINUATION. MAINTAIN MINIMUM 46" OF COVER. 11 SEE RISER DIAGRAM FOR WATER HEATER PIPING DIAGRAM. REFER TO MANUFACTURERS INSTRUCTIONS FOR EXACT REQUIREMENTS SET HOT WATER HEATER THERM05TAT TO 140- F. rim DINNO O O O r k �0 'DINING { { 4 rr— I RTU I I I I M1 5 L I s3J HIS p, I 5 G yres oil ® I don � Y' i it 4 - e i I CUSTARD R PLAN PLUMBING PLAN NOTES: 12 PROVIDE (1) $" VALVED CN CONNECTION FOR THE CUSTARD MACHINE DIPPER WELL. 13 ALL APPLIANOE CONNECTIONS SHALL BE MADE WITH UL LISTED FLEXIBLE APPLIANCE CONNECTOR. FLEX CONNECTORS SHALL BE PROVIDED BY TENANT. CONTRACTOR SHALL PROVIDE SAFETY LOOK AND CHAIN AT ALL GAS APPLIANCES ON WHEELS. PROVIDE PIPING REDUCERS AND INCREASERS AS REQUIRED TO MATE HARD PIPING WITH FLEX CONNECTORS. 14 CONNECT" GW TO WATER FILTER WITH BYPASS PER THE MANUFACTURER'S REQUIREMENTS. REFER TO KITCHEN EQUIPMENT DRAWINGS FOR DETAILS. 15 PROVIDE YS" FILTERED Cw TO SODA SYSTEM. PROVIDE RPZ BACKFLOW PREVENTOR AS APPROVED BY WATER DEPARTMENT IN ACCESSIBLE LOCATION (24" AFF) ADJACENT TO BA6-IN-BOX. NO COPPER PIPE DOWNSTREAM OF BFP. 16 COORDINATE WITH 6.C. TO SEAL PENETRATION WEATHER TIGHT. iT PROVIDE AND INSTALL RPZ BAGKFLOW PREVENTOR AS REQUIRED BY LOCAL JURISDICTION. ROUTE DISCHARGE PIPING TO FLOOR SINK WITH AIR GAP. 16 PROVIDE Al FILTERED CW TO ICE MACHINE WITH SHUT-OFF VALVE. 1R ROUTE PIPING ON INTERIOR SIDE OF INSULATION FOR FREEZE PROTECTION. ®O CONNECT RECIRCULATION PUMP TO WATER HEATER AS DETAILED IN THE RI5ER DIAGRAM. 21 PROVIDE SHUTOFF VALVE AND CONNECT FILTERED GW TO BEVERAGE DISPENSER WITH BACKFLOW PREVENTER AS REQUIRED BY THE MANUFACTURER. Q W GAS (2p5iJ WITH SHUT-OFF VALVE AND PRESSURE REGULATOR ON ROOF P14 MAXITROL 11525-5L, 150 GFH, 2951. INLET PRESSURE WITH -I" W.G. OUTLET PRESSURE). CONNECT TO ROOF TOP UNIT AS DETAILED AND AS REQUIRED. Q5/G' 6A5 (2p5i.) WITH SHUT-OFF VALVE AND PRESSURE REGULATOR ON ROOF (%' MAXITROL #325-5L, 150 GFH, 2p5i. INLET PRE55URE WITH " W.O. OUTLET PRESSURE). CONNECT TO WATER HEATER A5 DETAILED AND A5 REQUIRED. ©q 4" FIRE LINE, SSE CIVIL PLANS FOR CONTINUATION. MAINTAIN A MINIMUM 46" BURY FOR FREEZE PROTECTION. =I 11/7/2018 o. Pe11a00705 e PLUMBING PLAN NOTES: ©5 4" FIRE LINE THRU FLOOR WITH 4" GATE VALVE PER LOCAL CODE REQUIREMENTS. o �O " L PROVIDE USG CERTIFIED DOUBLE CHECK VALVE ASSEMBLY (DGVA) AND THE MAIN 11110 DRAIN VENTED TO DAYLIGHT. SEAL EXTERIOR WALL PENETRATION WEATHER TI6HT AS REQUIRED. COORDINATE WITH SPRINKLER CONTRACTOR FOR PROPER INSTALLATION. WINTER COORDINATE WITH WATER DEPARTMENT FOR SERVICE FLUSHING REQUIREMENTS. GAP ARCHITECTS LINE FOR FUTURE CONTINUATION BY SPRINKLER CONTRACTOR. QPROVIDE HOT AND GOLD HOSE BIBS AT 5'-5" AFF. CONNECT HOT AND GOLD WATER TO EA5IWASH SYSTEM PER THE MANUFACTURERS REQUIREMENTS. VERIFY THAT THE 1024 EAST EQUIPMENT HAS THE APPROPRIATE BACKlli PREVENTION AS REQUIRED BY THE FIRST STREET LOCAL JURISDICTION. PROVIDE AND INSTALL DOUBLE CHECK BAGKFLOW PREVENTERS WICHITA, KS. AS NECESSARY. 67214 OINSTALL ROOF HYDRANT PER THE MANUFACTURER'S REQUIREMENTS. COORDINATE WITH ROOFING CONTRACTOR FOR PENETRATION. ROUTE DRAIN PIPING FROM VALVE DRAIN PH. 316-267-7142 TO FLOOR DRAIN IN MECHANICAL ROOM WITH AN AIR GAP. DATE 11 an insommeni d Wood bond rm o��ernmedareb dsJoaredinhoomancononlyd m"o.a,�",.,:.."d"non,a,re�.. aN r Pool dM18K cool Im DRAWN BY: SM/TH CHECKED BY: DS/BD mENGINEERS INCORPORATED SHEETNO. P2 5720 Reeder Shawn ee, al 66203 (913)262-1772