HomeMy WebLinkAbout2018113-Freddys-Carmel, IN-E6-ELECTRICAL1 2 WALK-IN COOLER/ FREEZER LIGHTS&ACCESSORIES A A 12W6011, (20.D AMP CIRCUIT) JB 109'AFF, EC TO CONNECT ON TOP OF WALK-IN FOR LIGHTS AND ACCESSORIES, EC TO INSTALL & WIRE ALL LIGHT FIXTURES SHIPPED LOOSE, PER DETAIL 1A WALK-IN COOLER COMPRESSOR (REMOTE) A 2WRdY3,T7AMRS, DB, ON ROOF, EC TO PROVIDE DI SCONNECT,INTER-CONNECT TO EVAPORATOR COIL USING FACTORY PROVIDED WIRING HARNESS, REFER TO WALK-IN SHOP DRAWINGS FOR DETAILS 1.2 COOLER EVAPORATOR A 208hBW1,1.35 AMPS, JB POWER PROVIDED FROM CONDENSING UNIT ON ROOFTOP THRU FACTORY PROVIDED WIRING HARNESS, REFER TO WALK-IN SHOP DRAWINGS FOR DETAILS eFREEZER COMPRESSOR (REMOTE) A 206A50i 26 AMPSp JB ON ROOF EC TO PROVIDE DI SCONNECT INTER -CONNECT TO EVAPORATOR COIL USING FACTORY PROVIDED WIRING HARNESS, REFER TO WALK-IN SHOP DRAWINGS FOR DETAILS 22 WALK-IN FREEZER EVAPORATOR A 2086&1, OS AMPS.(FAR &DEFROST HEATER),JIM., POWER PROVIDED FROM CONDENSING UNIT ON ROOFTOP THRU FACTORY PROVIDED WIRING HARNESS, REFER TO WALK414 SHOP DRAWINGS FOR DETAILS, EC TO WRAP DRAIN WITH HEAT TAPE AND INSULATE 2 WALK-IN FREEZER HEAT TAPE B 120'W11, 1GoAMPS, WEATHERPROOF DR BEHIND EVAPORATOR FAN FOR HEAT TAPE, WRAP DRAIN WITH HEAT TAPE AND INSULATE eICE MACHINE - (BY OTHERS) A 12016011,18.5 AMPS, JB 96' AFF 1 REMOTE CONDENSER -(BY OTHERS) A 12W6011, EC TO WIRE TO REMOTE CONDENSER FROM ICE MACHINE HEAD, REFER TO DETAIL ON THIS PAGE 10 DISHWASHER -(BY OTHERS) A 120'W11,12D AMPS, JB 66'AFF, VERIFY ALL ROUGH -IN REQUIREMENTS 17 BAG-N430X-(BY OTHERS) A 12W6011,(15.0 AMP CIRCUIT), DR 60"AFF, VERIFY ALL REQUIREMENTS WITH SODA VENDOR 8,A FOOD WARMER 12W6011,10.4 AMPS, OR uB"AFF r20'Ni CHEESE WARMER A 120s60/1,1.]AMRS, DR 48"AFF 28 UTILITYOUTLET AM A 12W6011,(15.0 P CIRCUIT), DR EVE WE (TWO LOCATIONS) 1 32 FRY WARMING STATION A 12W60/1, 10,0 AMPS, OR a&-AFF EXHAUST HOOD LIGHTS A 130s60/1,(15.0 AMP CIRCUIT), JB DFA, EC TO WIRE LIGHTS TO HOOD CONTROL PANEL RELEASED FOR CONSTRUCTION I GETS TO HOOD CONTROL PANEL Subject to compliance with all regulations of State and Local Codes �VT�VI�DRA4IWML DATE: \ 04/03/19 ELECTRICAL REQUIREMENTS 23 WOW TABLE W/LOAD CENTER A 1201200 AMRS, J­BOX, Q4" AFF, EC TO WIRE THROUGH SHUNT TRIP BREAKER & INTERCONNECT TO FIRE SUPPRESSION SYSTEM. REFER TO WORK TABLE SHOP DRAWINGS - SHEET K-3 TO INCLUDE THE FOLLOWING: 18 FOOD WARMER A REFER TO LOAD CENTER ON WORK TABLE SHOP DRAWINGS 21 FOOD WARMERS (TWO REQUIRED) A REFER TO LOAD CENTER ON WORK TABLE SHOP DRAWINGS B22 PIZZAPREP TABLE (TWO REQUIRED) A REFER TO LOAD CENTER ON WORK TABLE SHOP DRAWINGS eDROP IN COLD PAN A REFER TO LOAD CENTER ON WORK TABLE SHOP DRAWINGS 24 BUN TOASTER (TWO REQUIRED) A REFER TO LOAD CENTER ON WORK TABLE SHOP DRAWINGS 25 HOT DOG HUTCH A REFER TO LOAD CENTER ON WORK TABLE SHOP DRAWINGS e48" GRIDDLE (TWO REQUIRED) A REFER TO LOAD CENTER ON WORK TABLE SHOP DRAWINGS 29 REFRIGERATED SANDWICH UNIT (TWO REQUIRED) A REFER TO LOAD CENTER ON WORK TABLE SHOP DRAWINGS b 46 CUSTARD MACHINE A 201.0 AMPS (EACH), SR 24" AFF, NEMA L15-20P 8115-2011, EC TO PROVIDE CORD AND PLUG, VERIFY ALL ROUGH -IN REQUIREMENTS (TWO LOCATIONS) eSODA DISPENSER - (BY OTHERS) A 12016011, 10.0 AMPS, DR 24" AFF, VERIFY PLL ROUGH -IN REQUIREMENTS b49 ICE MACHINE- (BY OTHERS) A 208'W11,(3-WIRE WITH DEDICATED GROUND) 18.5 AMPS, JB WE WE REMOTE CONDENSER -(BY OTHERS) A 12016011, EC TO WIRE TO REMOTE CONDENSER FROM ICE MACHINE HEAD, REFER TO DETAIL ON THIS PAC£ a6 ROB UNIT FRONT COUNTER -(BY OTHERS) A 12016011,(15,0 AMP CIRCUIT )(EACH), PROVIDE ISOLATED CIRCUIT, DR TV- AFF, VERIFY ALL ROUGH -IN REQUIREMENTS (TWO LOCATIONS) ROB UNIT DRIVE-THRU - (BY OTHERS) A 12016011,(15D AMP CIRCUIT), PROVIDE ISOLATED CIRCUIT OR 24" AFF, VERIFY ALL ROUG H-IN REQUIREMENTS D69 DISPLAY FREEZER A 12016011,11.OAMPRDR24'AFF 3 REACH4N REFRIGERATOR A 12016011,17 AMPS, DR 20" ARE ]4 HOOD CONTROL PANEL -(CABINET MOUNTED ON HOOD) A 1201 AMP CIRCUIT),J6., DROP FROM ABOVE, EC TO CONNECT LIGHTS, FANS, SWITCHES AND SENSORS AS REQUIRED, REFER TO HOOD & FAN SHOP DRAWINGS FOR DETAILS ABFIRE SYSTEM (REMOTE PULL STATION) REFER TO DETAIL ON THIS SHEET FOR REMOTE PULL STATION, (ONE FIRE PULL FOR SHARED 4, GRIDDLE HOOD EXHAUST FAN (NOT SHOWN ON DRAWINGS) A REFER TO HOOD & FAN SHOP DRAWINGS FOR DETAILS SYSTEM WITH ITEM # 33A & 33B) eFRYER SYSTEM A 4, FRYER HOOD EXHAUST FAN (NOT SHOWN ON DRAWINGS) REFER TO HOOD& FAN SHOP DRAWINGS FOR DETAILS A 12016011, 8.S AMPS, DR 2C ' AFF 35 bA REACH -IN FREEZER 4, MUA UNIT (NOT SHOWN ON DRAWINGS) REFER TO HOOD& FAN SHOP DRAWI NES FOR DETAILS A 12DI6D11, 9.5 AMPS, DR ]2"AFF e SODA DISPENSER -(BY OTHERS) A 4, CONDENSATE EXHAUST FAN (NOT SHOWN ON DRAWINGS) REFER TO HOOD& FAN SHOP DRAWINGS FOR DETAILS A 12016011,(10,0P CIRCUIT), OR 24" AFF, VERIFY ALL ROUGH -IN REQUIREMENTS WITH VENDOR AM 40 TEA BREWER -(BY OTHERS) ]] A FRY SAUCE CHILLERS 12DI6D11, 1.0 AMP, DR 48"AFF A 12016011,(15.OAMP CIRCUIT), OR 4P'AFF, VERIFY ALLROUGH-IN REQUIREMENTS 42 BLENDER ]8 A WATER FILTER CONTROLS 12016011, 1, 0 AMP, DR SEE AFF A 12016011, 2.1 AMPS, DR 24" AFF,(LND LOCATION S) M43 HOT FUDGE DISPENSER A 12016011,8.3AMPS,DR48"AFF DIPPINGCABINET AD12016011,8.0AMPS,DR20"AFF DIPPING CABINET A 120/6D/1,8DAMPS,DR24"AFF D85 VIDEO MONITOR -(BY OTHERS) A 12016011,(15.0 AMP CIRCUIT), DR64-3/e" AFF, VERIFY ALL ROUGH -INS NOTE: EC TO PROVIDECONTROL WIRING FROM ANSULCONTROL BOX TO REMOTE PULL STATION AS PULLEY& CONDUIT FROM THIS REQUIRED. POI NIT BY FIRE SUPPRESSION _ SYSTEM INSTALLER tr- 1Q"CONDUIT STANDARD OCTAGON BOX CONCEALED IN WALL RECESSED IN WALL(BY (BY ELEC.CONTR.) ELI CONTR.) MAINTAIN ORIENTATION OF JUNCTION BOX AS SHOWN 48E ME REMOTE FIRE PULL DETAIL NOT TO SCALE 4" STAMPED STEEL JET, BOX BY DIV 16 E.M.T. CONDUIT CROUSE HINDS (OR EQUAL) ES BY DIV, 16 SEALING HUB BY DIV 16 CEILING E.C. TO CUT HOLE AS RI GID STEEL CONDUIT O O DIRECTED BY K.E. C. VINYL THRU WALK IN BY DIV 16, SLEEVE AND GROMMETS SEAL BETWEEN CONDUIT BY DIV. 16 & SLEEVE WITH SEALANT- LIGHT MIXTURE PROVIDED BY BY DIV i6 K.EG,EC. TO SEAL BETWEEN BASE & CEILING E.C. TO PROVIDE & INSTALL LAMP 1. ALL CONDUIT TO BE RUN ON EXTERIOR OF WAUK-IN BY DIV. 16 UNLESS BOX IS LOCATED OUTDOORS. THEN CONDUIT IS TO RUN BELOW CEILING. 2 ALL PENETRATIONS THRU WALK-IN TO BE THOROUGHLY SEALED 1 ALL LIGHT FIXTURES TO PE FURNISHED BE K.E.C. 4. MOUNTING FIXTURES, ALL CCNDUR AND ALL INTER -WIRING BY DIV. 16. 5 ALL hAMPS (BUUBS)TO BE FURNISHED BY OTHERS. WALK-IN LIGHT DETAIL NOTTOSCALE ROOF TOP, Z AMPS) \ FOR 115V PT UQUID REFRIG. LINES & ELEC FROM MACHINE TO RUN IN WALL TO CONDENSER iICE MACHINE BE MANUFACTURED IS! Mel -U .0aVAaNMMaISlA 3' PVC ELBOW WHERE LIQUID REFRIG. LINES COME THRU WALL (]2- APE FOR BACK -OF -HOUSE, SN MOUNTED CURER 96- ARE FOR SODA DISPENSER MOUNTED CUBER) UQUID REFRIG. REMOTE ICE MACHINE DETAIL ELECTRICAL NOTES 1. THESE DRAWN GS ARE TO BE USED AS AN INSTRUMENT OF REFERENCE BY ALL OTHER TRADES AND CONTRACTORS. ALL TRADES SHALL VERIFY THE INFORMATION AS INDICATED ON THESE PLANS, 2, DIMENSIONS AND REQUIREMENTS FOR ALL EQUIPMENT THAT IS LISTED AS EXISTING, PROVIDED BY OTHERS OR PROVIDED BY OWNER, MUST BE VERIFIED WITH THE APPROPRIATE PARTIES. 3. ALL LOCAL, STATE AND NATIONAL CODES SHALL APPLY. 4, THESE UTILITY REQUIREMENT DRAWINGS INDICATE THE UTILITY AND LOCATION OF REQUIREMENTS BASED ON THE EQUIPMENT SPECIFIED. 5. ALL EQUIPMENT SHALL BE WIRED IN STRICT CONFORMANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND/OR SHOP DRAWINGS. 6, UNLESS OTHERWISE NOTED, ALL DIMENSIONS SHOWN ON THIS PLAN ARE FROM THE FINISHED FLOOR, CEILING, WALLS OR COLUMN CENTERLINES TO THE CENTERLINE OF THE ROUGH -INS. ]. ALL ELECTRICAL CONNECTION S ARE TO BE EXTENDED AND INTERCONNECTED TO CONNECTION POINTS ON THE EQUIPMENT BY OTHERS. UNLESS SPECIFIED, ALL HARDWARE REQUIRED FOR THESE CONNECTIONS SHALL BE SUPPLIED BY THE ELECTRICAL CONTRACTOR. a SURFACE MOUNTED WIRE AND CONDUIT WILL NOT BE ALLOWED, ALL ELECTRICAL LINES AND CONDUIT SHALL BE EXTENDED THROUGH AND OUT OF BUILDING WALLS WHERE POSSIBLE. WHERE SURFACE MOUNTED CONDUIT IS UNAVOIDABLE, IT MUST BE COORDINATED WITH HOCKENSERGS. 9, ROUGH -INS OUT OF FLOOR SHOULD BE STUBBED UP 4"ABOVE FINISHED FLOOR AND BROUGHT TO THE REQUIRED HEIGHT AFTER EQUIPMENT IS SET IN PLACE. 10, ALL 120 VOLT UTILITY OUTLETS TO BE G.F.C. I. OUTLETS. 11. ALL NECESSARY ELECTRICAL DISCONNECTS, SHUNT TRIP BREAKERS AND STARTERS PRE TO BE FURNISHED AND INSTALLED BY OTHERS, UNLESS PROVIDED AS A STANDARD OR SPECIFIED EQUIPMENT COMPONENT OF THE EQUIPMENT MANUFACTURER. THIS SHALL INCLUDE ELECTRICAL DISCONNECTS FOR ALL REMOTE COMPRESSORS, BOOSTER HEATERS AND OTHER ITEMS REQUIRED BY CODE, 12, ALL ELECTRICAL ITEMS SUPPLIED UNDER COOKING LINE EXHAUST HOOD ARE TO SHUT DOWN WITH SHUNT TRIP BREAKERS (BY OTHERS) CONNECTED TO FIRE SYSTEM. ELECTRICAL ENGINEER TO CONFIRM COMPLIANCE TO ALL CODES, 13, ALL OUTLETS, JUNCTION BOXES, DISCONNECTS, ETC. SHALL BE INSTALLED SO AS NOT TO INTERFERE WITH THE PERFORMANCE, FUNCTION, OR PLACEMENT OF THE EQUIPMENT. 14,STARTERS.RELAYS, HEATERS AND SWITCHES REQUIRED FOR EXHAUST AND SUPPLY FANS ARE TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 15. DISHMACHINES: A. ELECTRICAL CONTRACTOR SHALL INTERCONNECT DISHMACHINE WITH DISHMACHINE EXHAUST FAN. INTERCONNECTION SHALL UNK OPERATION OF EXHAUST FAN AND DISHMACHINE SO THAT BOTH UNITS RUN SIMULTANEOUSLY AT ALL TIMES. B. ELECTRICAL CONTRACTOR SHALL INTERCONNECT TABLE LIMIT SWITCH AT END OF CLEAN DISHTABLE WITH CONVEYOR TYPE DISHMACHINES. LIMIT SWITCH SHALL TERMINATE DISHMACHINE OPERATION WHEN DEPRESSED. 16, WALK-IN COOtEbFREEZER BOXES & REMOTE COMPRESSORS: A INTERCONNECT TO BLOWER COIL IN FREEZER. B. INTERCONNECT BETWEEN TIMER & CONTACTOR. C. INTERCONNECT BETWEEN TIMER& PRESSURE CONTROL SOLENOID. D. INTERCONNECT BETWEEN CONTACTOR AND COMPRESSOR FAN. E. INTERCONNECT BETWEEN TERMINAL AND CONTACTOR TO BLOWER COIL IN FREEZERS. R CONNECT DRAIN LINE HEATER TO RECEPTACLE IN FREEZER. G. CONNECT PAN HEATER TO TERMINAL STRIP IN FREEZERS. H. CONNECT DOOR HEATER TO TERMINAL STRIP IN FREEZERS. 17. ALL ELECTRICAL CONDUIT TO BE RUN ON TOP (EXTERIOR) OF WALK-IN COOLIER/FREEZER BOX WHERE POSSIBLE. 18 UNLESS PROVIDED BY THE MANUFACTURER, ALL LIGHT BULBS FOR FOODSERVICE EQUIPMENT TO BE PROVIDED BY OTHERS. ELECTRICAL SYMBOLS eREMEMBER ELECTRICAL ROUGHMN NOTE CONNECTION NUMBER (SEE SCHEDULE) SINGLE RECEPTACLE VI1 dI, DUPLEX RECEPTACLE QUADRECEPTACLE ISOLATED GROUND DUPLEX RECEPTACLE HIGH VOLTAGE RECEPTACLE JO JUNCTION BOX 4 SPECNLLOUTLET ® WALL SWITCH T TELEPHONE Y DATA '3w USB RECEPTACLE e'••• ELECTRICAL INTERCONNECTION REMOTE COMPRESSORS DIETERMIN DAYARCHHiTec�T RREEEEa�vAccesS & CONDENSING UNITS INTOAREAFCRCOMRRESCORSMUSTBEPROVIDEDBY OTHERS. TOALLOW PLACEMENT OF RACK AS WELLAS THESENOTESAPRYTOMULTI-SYSTEMCOMPRESSCRRACKSAS MAINTAIN MINIMUM CLFARANCE REQUIREMENTS. WELL AS INDIVIDUAL CCMPRE SOON S AND CONDENSERS. SUFFICIENT AIR CHANGES MUST BE PROVIDED IN THIS REMOVE REMOTE AREA, TO ALLOW ADEQUATE AIR CIRCULATION FOR COMPRESSOR WATER COOLED OR AIR COOLED COMPRESSORS. WATEROR FREEMR STRUCTURAL SUPPORT AS WELL AS CURBS, PADS OR REDWOOD RAILS FOR COMPRESSORS, ON ROOF OR INSIDE STRUCTURE, TO BE PROVIDED BY OTHERS. SEE MANUFACTURER'S SHOP DRAWINGS FOR DETAILED REQUIREMENTS FOR CLEARANCE ACTUAL SIZES, J J MECHANICAL, PLOWING & ELECTRICAL REQUIREMENTS. FOR WATER CONED UNITS, STRICT ADHERENCE TO 11 21 MANUFACTURERS REQUIREMENTS FOR MIN.1MAX. A A WATER TEMP AND PRESSURE MUST BE MAINTAINED. ASHRAE CALCULATIONS AND MY RESULTING CONDENSER CONDENSER REQUIREMENTS FOR COMPRESSOR AREA, PIPING CHASES AND FREON DETECTION SYSTEMS SHALL BE THE RESPCNSIBIUTY OF OTHERS. J J ALL REFRIGERANT PIPING CHASES AND BUILDING PENETRATIONS SHP1L BE THE RESPONSIBILITY OF THE 1 9. BUILDING TRADES AND TO COMPLY WITH ALL LOCAL A A CODES. EXACT LINE RUNS OF REFRIGERATION PIPING SHALL BE DETERMINED IN COORDINATION WITH THE REFRIGERATION INSTPLIER Al_ ELECTRICAL DISCONNECTS TO SE RROVIDEDBY OTHERS, Wpu ThMark Foodsacice Equipment, Supplies and Dlsign HOCKENBERGS 14603 W 112111 Street Lenexa, KS 66215 P 866.445.4999 tnmarkusa.com This document contains confidential information, is an instmment of aprofessional service, and the property of Tril It shall not be used on other projects orfor the extension of this project without TrlMarkS written approval. Owner and all Contractors to Check and verify existing dimensions and conditions in the field before starling construction and to notify Triu of any material or detail changes. REVISIONS DATE NO. DESCRIPTION MADE 06 li V / U Z LU O I. L N LU L.I. LL Z LU J w 'LU I 1010 (Y LL- Ci U ELECTRICAL REQUIREMENTS PLAN SHEET NUMBER'. E-6 THIS DOCUMENT WAS ORIGINALLY PRINTED ON A24' xM' SIZE SHEET