HomeMy WebLinkAbout2018113-Freddys-Carmel, IN-K2-BUILDING WORKSWALK-IN SLAB TO BE
LEVEL WITH BUILDING SIAB
rz
in
WALK-IN O.A DIMENSION
10' X 23'
Y
r
i
11
�
a_
j
OIL
OIL
LINE CONDUIT
AT 96' A F
L
T
e k
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
�VT�RJ'�D*T41WML_
DATE: \ 04/03/19
III
SEE ARCHITECTURAL
SHEETS FOR ALL WALL
BACKING NOTES
:::illllaa�01111111111roVof
BASE: CONCRETE 6' WE TO BE
JED BY OTHERS. NOTE: CURB MUE
UARE AND LEVEL TO THE COUNTS
ER. DIMENSIONS ARE FINISHED
(DING 51&' TILE) 'VERIFY ALL
(SIGNS WITH KITCHEN EQUIPMENT
6' PVC CONDUIT TO STUB THIRD THE
WALL UNDER COUNTER TOP DISPENSER
AT APPROX. IS"AFF- VERIFY WITH
OPENING IN BEVERAGE COUNTER
AT 96' AFF
AT APPROX. 1V' AFF -
SEE ARCHI TECTURAL
SHEETS FOR ALL WALL
BACKING NOTES
GENERAL CONSTRUCTION NOTES
1, THESE DRAWINGS ARE TO BE USED AS AN INSTRUMENT OF
REFERENCE BY ALL OTHER TRADES AND CONTRACTORS. ALL TRADES
SHALL VERIFY THE INFORMATION AS INDICATED ON THESE PLANS.
2, DIMENSIONS AND REQUIREMENTS FOR ALL EQUIPMENT THAT IS
U$TED AS EXISTING, PROVIDED BY OTHERS OR PROVIDED BY OWNER,
MUST BE VERIFIED WITH THE APPROPRIATE PARTIES.
3, ALL LOCAL STATE AND NATIONAL CODES SHALL APPLY.
4, ARCHITECT TO LOCATE, GENERAL CONTRACTOR TO PROVIDE ALL
OPENINGS IN WALLS, FLOORS, CEILINGS, AND ROOFS FOR THE
EXTENSION OF REFRIGERATION LINES, BEVERAGE LINES, ELECTRICAL
LINES, PLUMBING LINES, EXHAUST AND SUPPLY VENTILATION DUCTS.
CURBS, PITCH POCKETS OR SPECIAL FINISHING FOR THESE OPENINGS
SHALL BE SUPPLIED BY OTHERS.
5 SUPPLY FINS TO BE LOCATED A MINIMUM OF 19'-6'FROM ANY AIR
INLET OR OUTLET ON THE ROOF SUCH AS EXHAUST FANS, VENT
STACKS, NR CONDITIONERS, REFRIGERATION COMPRESSORS, ETC.
6. ALL INFORMATION PROVIDED FOR FOOD SERVICE HOOD SYSTEMS
PERTAINING TO QUANTITY, SIZE AND LOCATION OF EXHAUST AND
SUPPLY DUCT COLLARS, CFM RATINGS AND STATIC PRESSURE MU Sf
BE CONFIRMED WITH THE MANUFACTURER'S APPROVED SHOP
DRAWINGS.
T. GENERAL CONTRACTOR TO PROVIDE 314" PLYWOOD WALL BACKING ON
WALLS FOR WALL MOUNTED EQUIPMENT. ALTERNATIVE FOR
PLYWOOD MUST BE USED UNDER HOODS AND AT FIRE RATED WALLS
PER LOCAL CODES. ALL WALL BACKING MUST BE BEHIND WALL FINISH.
NO EXPOSED WALL BACKING SHALL BE ALLOWED. LOCATION AND
HEIGHT TO BE COORDINATED WITH MANUFACTURER'S SHOP
DRAWINGS AND SPECIFICATION SHEETS.
& PROVIDE COVED BASES AT ALL VERTICAL INTERSECTIONS OF FLOORS
IN KITCHEN AND STORAGE AREAS.
9. ALL HVAC REGISTERS ARE TO BE LOCATED SO AS TO PREVENT ANY
INTERFERENCE IN PERFORMANCE OF EXHAUST HOODS, HEATERS OR
WARMERS.
19, BOTTOM OF HOODS ARE TO BE MOUNTED AT 64' ABOVE FINISHED
FLOOR, UNLESS OTHERWISE SPECIFIED BY LOCAL CODES.
11.RECOMMENDED CEILING HEIGHTS ARE LISTED BELOW. CONTACT
HOCKENBERGS IMMEDIATELY IF MINIMUM HEIGHTS ARE LESS THAN
THOSE INDICATED:
A KITCHEN AREAS WITH EXHAUST HOODS: 96'
B. KITCHEN AREAS WITH WAWHN COOtERhFREEZERS: 74"
C. KITCHEN AREAS WITH ICE MACHINES &or COMPRESSORS: 9'-6'
D. GENERAL KITCHEN AREAS: S-9"
12. REMOTE CONDENSING UNITS & COMPRESSOR UNITS ARE TO BE
LOCATED OUTSIDE WHERE POSSIBLE. FOR INSIDE LOCATIONS,
VERIFY PROVISION OF SUFFICIENT VENTILATION WITH
MANUFACTURER. ARCHITECT TO LOCATE ALL REMOTE
COMPRESSORS AND CONDENSERS IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS.
GENERAL CONSTRUCTION &
BUILDING WORKS LEGEND
40�BEVERAGE UNE
uuuuuuuuuuuue INWALLBACKING
• • • • SODALINECONDUIT
� w w� w w� w w� BEERANINE LINE CONDUIT
WWZ
ThMark
Foodt�alce Equipment, Supplies and Drsign
HOCKENBERGS
14693 W 112th Street
Lenexa, KS 65215
P 866.445.4999
tnmarkusa.com
This document contains
confidential information, is an
instrument of aprofessional
service, and the property of
TnMark. It shall not be used on
other projects orfor the extension
of this project without TrlMarkS
written approval.
Owner and all Contractors to
check and verify existing
dimensions and conditions in
the field before starling
construction and to notify
TriMark of any material or detail
changes.
REVISIONS
DATE NO. DESCRIPTION MADE ffif
W
0
V /
U
Z
LU
0
ry
LU
ry
�
m
Q
Z
LU
LU
LU
LL
(I)
U
BUILDING
WORKS
PLAN
SHEET NUMBER'.
K-2
THIS DOCUMENT WAS ORIGINPLLY PRINTED ON A24' x36-SIZE SHEET