HomeMy WebLinkAbout01-Carmel IN-C1-C1Iii zTelmmIk9xot0
9701 N. MICHIGAN, RD.
CARMEL, I N . 46032
(HAMILTON COUNTY)
DAN WINTER ARCHITECT
1024 E. FIRST WICHITA, KS. 67214 - (316)267-7142
MECHANICAL ENGINEER.: T/ BC ENGINEERS
ELECTRICAL ENGINEER) 5720 Reeder St, Shawnee, KS 66203(913) 262-1772
PLUMBING ENGINEER:
STRUCTURAL ENGINEER:— M.K.E.C. ENGINEERING
CONSULTANTS, INC.
411 NORTH WEBB ROAD, WICHITA, KANSAS. 67206
(316) 684 - 9600 FAX (316) 618-8083
CIVIL:
KITCHEN EQUIPMENT
1 11 �jl L�_TZAVA
CIVIL SITE
160 WEST CARMEL DRIVE, SUITE 240, CARMEL, IN. 46032
(317) 810 - 1677 FAX (317) 810-1679
TRIMARK HOCKENBERGS
14603 WEST 112Ih, LENEXA, KS. 66215 - (913)491-4999
BUILDING CODE:
2014 INDIANA
BUILDING CODE
PLUMBING CODE:
2012 INDIANA
PLUMBING CODE
MECH. CODE:
2014 INDIANA
MECHANICAL CODE
ELECT. CODE:
2009 INDIANA
ELECTRICAL CODE
FUEL CODE:
2014 INDIANA
FUEL GAS CODE
FIRE CODE:
2014 INDIANA
FIRE CODE
ENERGY CODE:
2010 INDIANA
ENERGY CONSERVATION CODE
ADA:
ADA ACCESSIBILTY
GUIDELINES (ANSI 117)
BUILDING SUMMARY
NUMBER OF STORIES:
1
BUILDING HEIGHT:
22'-0"
BUILDING AREA:
3,572 SQ. FT.
BUILDING TYPE:
VB
USE GROUP:
A2
OCCUPANT LOAD:
104
SPRINKLER SYSTEM:
YES
EMERGENCY LIGHTING:
YES
NUMBER OF EXITS REQUIRED:
2
NUMBER OF EXITS PROVIDED:
3
MAXIMUM TRAVEL DISTANCE:
200'-0"
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
dVT�T lonDklDA�
DATE: \\ 04/03/19
PLAN NOTES:
• DO NOT SCALE DRAWINGS -WRITTEN DIMENSIONS TAKE PRECEDENT.
• IN CASE OF DISCREPANCIES OR CONFLICTS, NOTIFY ARCHITECT IMMEDIATLEY.
• ALL WOOD IN CONTACT WITH CONCRETE AND AT EXTERIOR LOCATIONS MUST BE PRESSURE TREATED
MOISTURE RESISTANT WOOD.
• ALL WALL CONSTRUCTION FACING PLUMBING FIXTURE AREA MUST UTILIZE MOISTURE RESISTANT GYPSUM
BOARD UNLESS OTHERWISE NOTED.
• ALL DOORS TO BE KEYLESS IN DIRECTION OF EGRESS.
• ALL MEANS OF EGRESS DOOR OPENING HARDWARE SHALL BE OPERATED BY A SINGLE HAND WITHOUT
MEANS OF TIGHT GRASPING, PINCHING OR TMI OF THE WRIST. ALL DOORS EQUIPPED NTH PANIC
HARDWARE MUST MAINTAIN A 32" CLEAR WIDTH. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT
EXCEED:
A. 8.5 L.B.F. (37.7N) FOR EXTERIOR DOORS.
B. 5.0 L.B.F. (22.2N) FOR INTERIOR DOORS.
• DOORS SHALL SET IN MOTION WHEN SUBJECTED TO A 30 POUND FORCE & SWING TO A FULL -OPEN
POSITION WHEN SUBJECTED TO A 15 POUND FORCE. FORCES SHALL BE APPLIED TO THE LATCH SIDE.
• DOORS INDICATED AS PART OF THE REQUIRED MEANS OF EGRESS SHALL HAVE HARDWARE WHICH IS
READILY OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE OR
SPECIAL EFFORT.
• PROVIDE FIRE EXTINGUISHERS AS REQUIRED PER APPLICABLE CODES AND COORDINATE EXACT LOCATION
WITH FIRE MARSHAL.
• PROVIDE AND INSTALL OCCUPANCY SIGN IN A CONSPICUOUS LOCATION IN ACCORDANCE WITH STATE &
LOCAL CODES.
• ALL LIGHT SWITCHES, THERMOSTATS, SECURITY ALARMS, ELECTRICAL OUTLETS, ETC. MUST BE MOUNTED
TO MEET ALL GOVERNING ACCESSIBILITY REQUIREMENTS FOR FLOOR & HEIGHT CLEARANCES AND ONE
HAND GRASPING OPERATION.
• CONTROLS SUCH AS EIGHT SWITCHES, HEATING/AIR CONDITONING CONTROLS, FIRE ALARM PULLS AND
ELECTRICAL OUTLETS ARE WITHIN SPECIFIED REACH RANGES AND HAVE ADEQUATE CLEAR FLOOR
SPACE FOR ACCESS. OPERABLE PARTS MUST BE OPERABLE WIN ONE HAND AND NOT REQUIRE TIGHT
PINCHING OR GRASPING.
• ALL INTERIOR DIMENSIONS ARE FACE OF STUD TO FACE OF STUD. UNLESS NOTED OTHERWISE.
• REINFORCING STEEL OR STRUCTURAL FRAMEWORK OF ANY PART OF ANY BUILDING OR STRUCTURE
SHALL NOT BE COVERED OR CONCEALED WITHOUT RECEIVING INSPECTION APPROVAL BY THE LOCAL
JURISDICTIONS BUILDING INSPECTOR. IN ADDITION TO REWIRED ELECTRICAL, MECHANICAL AND PLUMBING
INSPECTIONS, THE BUILDING PERMIT HOLDER OR HIS AGENT SHALL REQUEST THE LOCAL JURISDICTIONS
BUILDING INSPECTOR TO MAKE THE FOLLOWING CALLED BUILDING CONSTRUCTION INSPECTIONS.
a. FOUNDATION INSPECTION PRIOR TO THE POURING OF CONCRETE.
b. FRAME INSPECTION AFTER PIPES, CHIMNEYS AND VENTS ARE INSTALLED BUT PRIOR TO
CONCEALING THE FRAMEWORK.
c. INSULATION AND WALL BOARD INSPECTION.
d. FINAL INSPECTION PRIOR TO OCCUPANCY OF THE BUILDING.
• A SET OF BUILDING PLANS AND SPECIFICATIONS APPROVED BY THE LOCAL JURISDICTIONS BUILDING
INSPECTOR AND MARKED °FIELD COPY" SHALL BE KEPT ON THE PROJECT DURING CONSTRUCTION UNTIL
FINAL INSPECTOR APPROVAL HAS BEEN MADE.
• CHANCES MADE DURING CONSTRUCTION OF A PROJECT, THAT AFFECT EXITING, WALL CONFIGURATION
AND STRUCTURAL ELEMENTS THAT ARE NOT JUST 'COSMETIC" REQUIRE REVISED PLANS TO BE
SUBMITTED TO THE OFFICE OF LOCAL JURISDICTIONS BUILDING INSPECTOR FOR RENEW AND APPROVAL.
IF A LICENSED ARCHITECT OR ENGINEER SEALED THE ORIGINAL PLANS, THE REVISED PLANS MUST ALSO
BE SEALED.
• THE TYPE 1 HOOD AND EXTINGUISHING SYSTEM SHALL BE INSTALLED BY A LICENSED CONTRACTOR.
THE SYSTEM SHALL BE TESTED AND WITNESSED BY THE LOCAL ARE PREVENTION DEPARTMENT
AREACALCULATTONS
(NET)
VESTIBULE
42 SQ. FT.
DINING
17M SO FT
CUSTARD
240 S0. FT.
COQQINE
dK0 So. FT.
DISHWARE
158 so. FL
STORAGE
215 SO, FT
MECHANICAL
218 Sp FT.
ce SO. FT
RESTROOMS
230 50. FT.
HALL
44 CO. FT
COOLER FREEZER.
241 50. FT
FREDDYS AREA
3,572 SO. FT
SEATING CALCULATIONS
IN STOLE
13
1 4 SEAT BOOTHS
52
10
1 4 SEAT TABLES
40
2
1 4 SEAT HICJDW iA&ES
8
TOTAL IN STORE UININO
100
PATD
5 fi SEAT TABLES
m
TOTAL w ATIo SEAT IC
130
DRAWINGS INDEX
SHEET
TITLE
DATE
REV. DATE
C1
COVER SHEET &INDEX
02I28119
4 0312&19
RMI
RESPONSIBILITIES/ADA/NOTES
OW28119
C0.0
COVERSHEET
02/28119
03I20I19
C 1.0
EXISTING CONDITIONS & DEMOLITION PLAN
OD28/19
132.0
SITE PLAN
OD28/19
03120/19
C2A
UTILITY PLAN
02128119
d 03120119
C2.2
GRADING & DRAINAGE PLAN
/2/28119
03120119
C2S
GRADING & DRAINAGE PLAN
02/28/19
03I20119
C3.0
STORMWATER POLLUTION PREVENTION PLAN
2J28119
C3.1
STORMWATER POLLUTION PREVENTION DETAILS
2128119
C3.2
STORMWATER POLLUTION PREVENTION NOTES
028119
C4.0
INDOT DETAILED ENTRANCE PLAN
028119
C4.1
INDOT MAINTENANCE OF TRAFFIC PLAN
& EXISTING CONDITIONS
028119
C6.0
STORM SEWER PLAN & PROFILE
2128/19
031
CIOU
GENERAL DETAILS
2128/19
CIICA
GENERAL DETAILS
2/28/19
C10.2
GENERAL DETAILS
028119
4310.3
GENERAL DETAILS
028119
10H
ADS COVER SHEET
028119
2 OF
STORMTECH
028119
301
STORMTECH
028119
4 OF
STORMFECH
2/28/19
5OF6
STORNTTECH
2/28/19
6 OF
STORMTECH
2/28/19
Cll.0
SPECIFICATIONS
OD28119
DIX
LANDSCAPE PLAN
0028/19
SO
ELECTRICAL SITE LIGHTING PLAN
02/28/19
ALTA
ALTNNSPS/LAND TITLE TOPOGRAPHIC SURVEY
02/28119
SR1
SOILS REPORT SHEETS PER SOIL REPORT
02J28119
SIBS
SOILS REPORT SHEETS PER SOIL REPORT
02/28/19
SIBS
SOILS REPORT SHEETS PER SOIL REPORT
OD28/19
SR4
SOILS REPORT SHEETS PER SOIL REPORT
OD28/19
ERE
SOILS REPORT SHEETS PER SOIL REPORT
0028119
S-0
STRUCTURAL SCHEDULES& DETAILS
0028/19
S-1
STRUCTURAL GENERAL NOTES
02/28/19
S-2
FOOTING& FOUNDATION PLAN
2J28I19
Si
SLAB PLAN
0028119
S-3
ROOF FRAMING PLAN
0028119
S4
FOOTING& FOUNDATION SECTIONS
02/28/19
S-5
ROOF SECTIONS
02/28/19
S-6
ROOF SECTIONS
02/28/19
SA1
NOT USED
SA2
I TRASH ENCLOSURE PLAN & DETAILS
OD28/19
SA3
SAFE PLAN DETAILS
OD28119
SA4
SAFE PLAN DETAILS
0028119
A0.0
FLOOR DRAIN LOCATION PLAN
0028119
AC.1
UFILIFY SUPPLY LOCATION PLAN
02/28/19
AIX
STUD WALL LAYOUT PLAN
02/28119
ALL
ARCHITECTURAL FLOOR PLAN
02/28119
4 03/28/19
AL2
DOORFINISHE SCHEDULE
OD28/19
L4N, 03128119
Pi
FLOOR FINISH PLAN
OD28/19
A2
REFLECTED CEILING PLAN
02/28/19
A2.1
SOFFIT DETAILS
02/28119
A3
EXTERIOR ELEVATIONS
02128/19
A4
EXTERIOR ELEVATIONS
02228119
4 0312&19
AS
ROOF PLAN
OW28119
A&0
EXTERIOR WALL SECTIONS
02/28119
A6.1
EXFERIOR WALL SECTIONS
2/28/19
A&2
EXFERIOR WALL SECTIONS
0028119
ASS
EXFERIOR WALL SECTIONS
02J28119
A6.4
EXTERIOR WALL SECTIONS
0028119
ABE
FLASHING DETAILS
02/28/19
A7
INTERIOR ELEVATIONS & DETAILS
02/28/19
ARA
INTERIOR ELEVATIONS & DETAILS
OD28/19
AT2
RESTROOM ELEVATIONS & DETAILS
OD28/19
AS
INTERIOR KITCHEN ELEVATIONS
=28/19
A9
CABINET SECTIONS
0028119
AID
COUNTER LAYOUT & DETAILS
2/28119
All
WALL PARTITION TYPES
2/28/19
K-1
EQUIPMENT LAYOUT PLAN
2J28I19
K-2
BUILDING WORKS PLAN
2128119
K-3
LOAD CENTER TABLE
3028119
MPO
MECHANICAL SPECIFICATIONS
D028119
ME!
MECHANICAL FLOOR PLAN
2/28119
M2
MECHANICAL SCHEDULES & DETAILS
2/28119
M3
KITCHEN HOOD DRAWINGS
02128119,
M4
KITCHEN HOOD DRAWINGS
02128119
MS
KITCHEN HOOD DRAWINGS
02128119
P1
I PLUMBING WASTE&VENT FLOOR PLAN
0028/19
P2
PLUMBING WATER AND GAS FLOOR PLAN
02/28/19
P3
PLUMBING RISER DIAGRAMS
02/28119
P4
PLUMBING REQUIREMENTS PLAN
OW28119
E-0
ELECTRICAL SPECIFICATIONS
OD28/19
E-1
ELECTRICAL POWER PLAN
OD28/19
E-1A
ELECTRICAL ROOF POWER PLAN
02/28119
E-2
ELECTRICAL LIGHTING PLAN
02/28/19
E-3
ELECTRICAL LOW VOLTAGE PLAN
02/28/19
E4
ELECTRICAL PANEL SCHEDULE
02/28/19
E-5
ELECTRICAL SITE LIGHTING PLAN
OD28/19
E-6
ELECTRICAL REQUIREMENTS PLAN
=28/19
b
WWI.
lyi�6�
THE DESIGN AND DETAILS
DISCLOSED HEREIN ARE THE
EXCLUSIVE PROPERTY OF
VANDER ARCHITECTS INC. AND
SHALL NOT BE COPIED OR
REPRODUCED IN MOLE OR
IN PART WHFHCUT ITS PRIOR
WRITTEN CONSENT.
DAN HINTER, ARCHITECT
N�
1�
`Q
1�,w■
Y /
Q
U�
Z
z
WV
/Q��
092
U.
z
Q
U
NW
W
UL
WINTER
ARCHITECTS
1024 EAST
FIRST STREET
WICHITA, KS.
67214
PH. 316-267-7142
PROJECT II
ARCHITECT:
RODGER BAKER
TITLE
SHEET
18
3/28/2019
171LPF1
SHEET NO.
C1