Loading...
HomeMy WebLinkAbout19030148 Structural AnalysisEng. Number OAA743689_C2_01 December 19 2018 Page 1 of 2 ATC Tower Services, Inc. - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 – 919-468-0112 Office - 919.466.5414 Fax - www.americantower.com Structural Evaluation ATC Site Number & Name 92397, North Carmel, IN Carrier Site Number & Name IN0106, West Clay Site Location 2525 W 141st Street Westfield, IN 46074-9676, Hamilton County 39.99021667 N / 86.20723333 W Tower Description 148 ft Monopole Basic Wind Speed Basic Wind Speed w/ Ice Code 90 mph (3-Second Gust, Vasd) / 115 mph (3-Second Gust, Vult) 40 mph (3-Second Gust) w/ 1” ice ANSI/TIA-222-G / 2012 IBC / 2014 Indiana Building Code Existing and Reserved Equipment Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD 148.0 150.0 3 Nokia FRIG w/o Solar Shield Low Profile Platform (6) 1 5/8" Coax (6) 1 1/4" Coax (1) 1.58" Hybrid T-Mobile 3 Nokia FHFB 148.0 3 RFS ATMAA1412D-1A20 1 Raycap ASU9338TYP01 1 Nokia FXFB 3 RFS APXV18-206517S-C-A20 6 Andrew TMBXX-6516-A2M with actuator 140.0 140.0 3 Ericsson RRUS A2 B4 Platform w/ Handrails (6) 7/8" Coax (3) 1.56" Hybrid Verizon 3 Ericsson RRUS A2 B2 3 Ericsson RRUS B13 w/ RRUS A2 3 Ericsson RRUS12 B4/AWS 3 Ericsson RRUS-12 B2 3 Commscope RC3DC-3315-PF-48 6 Antel LPD-7905/8 6 Kathrein 800 10865 130.0 130.0 2 Raycap DC6-48-60-18-8F Platform w/ Handrails (6) 1 5/8" Coax (2) 0.39" Fiber Trunk (2) 0.78" 8 AWG 6 (1) 2" conduit (1) 3/8" RET Control Cable AT&T Mobility 6 Powerwave LGP17205 3 Ericsson RRUS 32 B2 3 Ericsson RRUS-32 3 Ericsson RRUS-11 3 Powerwave RA21-7770.00 3 KMW ET-X-UW-70-16-70-18-iR-AT 125.0 125.0 1 RFS SCX2-190xxx Side Arm (1) E105 Verizon 115.0 115.0 3 Samsung RRH-P4 Platform w/ Handrails (3) 1.26" (32mm) Hybrid (Type 5) (1) 1.16" Hybrid Sprint Nextel 3 Samsung RRH-C2A 3 Samsung FD-MIMO Radio 1 Powerwave P90-15-XLPP-RR 2 KMW ET-X-TS-70-15-62-18-iR-RD 105.0 - - - Empty Low Profile Platform - Other 85.0 85.0 6 EMS RV65-18-02DP T-Arm w/ Platform (6) 1 5/8" Coax Cleveland Unlimited 79.0 79.0 1 Procom CXL 900-3LW Side Arm (1) 1/2" Coax Sigfox S.A. 1 5" x 3" x 2" Cavity Filter 1 Low Noise Amplifier Eng. Number OAA743689_C2_01 December 19 2018 Page 2 of 2 ATC Tower Services, Inc. - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 – 919-468-0112 Office - 919.466.5414 Fax - www.americantower.com Equipment to be Removed Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD 130.0 130.0 3 Andrew SBNHH-1D65C - (2) 0.78" 8 AWG 6 AT&T Mobility 6 Kaelus DBC0062F1Vxx-1 3 Ericsson RRUS 12 w/ RRUS A2 Proposed Equipment Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD 130.0 130.0 6 Kaelus DBC0061F1V51-2 Platform w/ Handrails (4) 0.92" Cable (3) 7/8" Coax (1) 0.39" Fiber Trunk AT&T Mobility 3 Ericsson RRUS 4426 B66 3 Ericsson RRUS 4478 B14 1 Raycap DC6-48-60-18-8F 3 Ericsson RRUS 4478 B5 3 Ace Technology XXQLH-654L8H8-iVT 1 Mount elevation is defined as height above bottom of steel structure to bottom of mount, RAD elevation is defined as center of antenna above grade level (AGL). Install proposed coax inside of the pole shaft. The existing and proposed loads listed in the tables above are compared to the tower’s current design capacity or previous structural analysis. The tower should be re-evaluated as future loads are added or if actual loads are found different from those listed in the tables. The subject tower and foundation are adequate to support the above stated loads in conformance with specified requirements. CQ/ANG