Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A023
SCALE: 3/4" = 1'-0" PLAN DTL - 3'-0"w. LANDING w/ STEPS TO GRADE @ HORIZONTAL SIDING 3'-0" 10" 10" 10"3'-0" 1'-0"4'-0"24" Ø FROST FOOTING 12" Ø CARRIAGE BOLTS 2x2 PICKETS @ 5" o.c. JOIST HANGER 2x6 P.T. LEDGER - HOLD T/ LEDGER 4" BELOW DOOR THRESHOLD 2x6 P.T. DECK JOIST - @ 16" o.c. 5/4 x 6 P.T. DECKING 2x2 PICKETS @ 5" o.c. 4x4 P.T. POST - 36" BELOW GRADE 12" Ø CARRIAGE BOLTS - 16" o.c. STAGGERED 2x BAND BOARD - SIZE VARIES 2x12 P.T. TREADS & STRINGERS - MAX. 81 4" RISE (MIDWEST) - MAX. 73 4" RISE (ATLANTA) - FIELD VERIFY NUMBER OF TREADS 2x4 BLK'G. SET 1" BACK FROM NOSING - TO PREVENT PASSAGE OF 4" Ø SPHERE - SHOWN BELOW 01 6'-0" 10" 10" 10"3'-0" 1'-0"4'-0"SCALE: 3/4" = 1'-0" PLAN DTL - 6'-0"w. LANDING w/ STEPS TO GRADE @ HORIZONTAL SIDING JOIST HANGER 2x6 P.T. LEDGER - HOLD T/ LEDGER 4" BELOW DOOR THRESHOLD 2x6 P.T. DECK JOIST - @ 16" o.c. 5/4 x 6 P.T. DECKING 2x2 PICKETS @ 5" o.c. 4x4 P.T. POST - 36" BELOW GRADE 12" Ø CARRIAGE BOLTS - 16" o.c. STAGGERED 2x BAND BOARD - SIZE VARIES 24" Ø FROST FOOTING 12" Ø CARRIAGE BOLTS 2x2 PICKETS @ 5" o.c. 2x12 P.T. TREADS & STRINGERS - MAX. 81 4" RISE (MIDWEST) - MAX. 73 4" RISE (ATLANTA) - FIELD VERIFY NUMBER OF TREADS 2x4 BLK'G. SET 1" BACK FROM NOSING - TO PREVENT PASSAGE OF 4" Ø SPHERE - SHOWN BELOW 02 SCALE: 3/4" = 1'-0" PLAN DTL - 3'-0"w. LANDING w/ STEPS TO GRADE @ BRICK VENEER 3'-0" 10" 10" 10"3'-0" 1'-0"4'-0"12" Ø CARRIAGE BOLTS 2x2 PICKETS @ 5" o.c. JOIST HANGER 2x6 P.T. LEDGER - HOLD T/ LEDGER 4" BELOW DOOR THRESHOLD 2x6 P.T. DECK JOIST - @ 16" o.c. 5/4 x 6 P.T. DECKING 2x2 PICKETS @ 5" o.c. 4x4 P.T. POST - 36" BELOW GRADE 2x12 P.T. TREADS & STRINGERS - MAX. 814" RISE (MIDWEST) - MAX. 73 4" RISE (ATLANTA) - FIELD VERIFY NUMBER OF TREADS 2x4 BLK'G. SET 1" BACK FROM NOSING - TO PREVENT PASSAGE OF 4" Ø SPHERE - SHOWN BELOW 3" 2'-6" BRICK BRACKET - INSTALL PER MANUFACTURER'S INSTRUCTIONS 2x BAND BOARD - SIZE VARIES 3" 24" Ø FROST FOOTING 03 07 D5.0 06 D5.0 07 D5.0 06 D5.0 6'-0" 10" 10" 10"3'-0" 1'-0"4'-0"SCALE: 3/4" = 1'-0" PLAN DTL - 6'-0"w. LANDING w/ STEPS TO GRADE @ BRICK VENEER JOIST HANGER 2x6 P.T. LEDGER - HOLD T/ LEDGER 4" BELOW DOOR THRESHOLD 2x6 P.T. DECK JOIST - @ 16" o.c. 5/4 x 6 P.T. DECKING 2x2 PICKETS @ 5" o.c. 4x4 P.T. POST - 36" BELOW GRADE BRICK BRACKET - INSTALL PER MANUFACTURER'S INSTRUCTIONS 2x BAND BOARD - SIZE VARIES 12" Ø CARRIAGE BOLTS 2x2 PICKETS @ 5" o.c. 2x12 P.T. TREADS & STRINGERS - MAX. 814" RISE (MIDWEST) - MAX. 73 4" RISE (ATLANTA) - FIELD VERIFY NUMBER OF TREADS 2x4 BLK'G. SET 1" BACK FROM NOSING - TO PREVENT PASSAGE OF 4" Ø SPHERE - SHOWN BELOW 7" 2'-5" 7"2'-5" 24" Ø FROST FOOTING 04 05 06 07 SCALE: 3/4" = 1'-0" ELEV. - LANDING w/ STEPS TO GRADE3'-0"12" Ø CARRIAGE BOLTS 2x2 PICKETS @ 5" o.c. 2x12 P.T. TREADS & STRINGERS - MAX. 81 4" RISE (MIDWEST) - MAX. 73 4" RISE (ATLANTA) - FIELD VERIFY NUMBER OF TREADS 214"2x6 P.T. TOP RAIL - HOLD PICKETS DOWN 214" FROM TOP 2x4 BLK'G. SET 1" BACK FROM NOSING - TO PREVENT PASSAGE OF 4" Ø SPHERE 12" HANDGRIP GROOVE - SEE DTL. 08/D5.0 3'-0"SCALE: 1" = 1'-0" BRICK VENEER CAST-IN-PLACE CONCRETE FOUNDATION WALL STRUCTURAL SHEATHING 1x TRIM BOARD 12" Ø CARRIAGE BOLTS - 16" o.c. STAGGERED GALV. DECK FLASHING JOIST HANGER 5/4 x 6 P.T. DECKING 2x6 P.T. DECK JOIST 2x6 P.T. LEDGER - HOLD T/ LEDGER 4" BELOW DOOR THRESHOLD - RIP TO FIT 2x BAND BOARD - SIZE VARIES 2"2" CAULK - SMOOTH OUT w/APPLICATOR SECTION DETAIL - LEDGER BOARD @ BRICK VENEER4"BRICK BRACKET - INSTALL PER MANUFACTURER'S INSTRUCTIONS SCALE:1" = 1'-0" HORIZONTAL SIDING CAST-IN-PLACE CONCRETE FOUNDATION WALL STRUCTURAL SHEATHING - EXTEND SHEATHING TO 12" BELOW T/FOUNDATION 1x TRIM BOARD 12" Ø CARRIAGE BOLTS - 16" o.c. STAGGERED GALV. DECK FLASHING JOIST HANGER 5/4 x 6 P.T. DECKING 2x6 P.T. DECK JOIST 2x6 P.T. LEDGER - HOLD T/ LEDGER 4" BELOW DOOR THRESHOLD - RIP TO FIT 2x BAND BOARD - SIZE VARIES 2"2" CAULK - SMOOTH OUT w/APPLICATOR POLY FLASHING SECTION DETAIL - LEDGER BOARD @ HORIZONTAL SIDING4"08 SCALE: 1 1/2" = 1'-0" SECTION - HANDRAIL 12" HANDGRIP GROOVE - BOTH SIDES 512"134"314" 214"2x2 P.T. PICKET @ 5" o.c. - HOLD DOWN 21 4" FROM T/ 2x6 TOP RAIL 2x6 P.T. TOP RAIL 13 SCALE: SECTION - FOOTING @ DECK COLUMN 3/4" = 1'-0" 1'-6"REFER TO GENERAL NOTES FORMINIMUM FROST FOOTING DEPTH18"Ø C.I.P. CONCRETE FT'G - REFER TO GN FOR MIN. FROST FOOTING DEPTH APPROXIMATE LINE OF GRADE 'SIMPSON' STANDOFF POST BASE - # ABA66Z - ANCHOR TO FOOTING w/ 12"Ø EXPANSION BOLTS, EMBED MINIMUM 4" 12 1± 6x6 P.T. POST - FLUSH w/ TOP OF DECK JOISTS 512" NOTE: 22"Ø C.I.P. CONCRETE FT'G @ CENTER OF 17'-6"w. DECK - REFER TO GN FOR MIN. FROST FOOTING DEPTH WILLIAM L.KAUF H OL Z ARCHITECTTALLYNS RIDGEREASON FOR PLOT: PLOT DATE: Job No. Sheet No.INHOMESITE NO. OFFICE REVIEW:MASTER BY: DATE: C DATE: 3940 OLYMPIC BLVDERLANGER, KY 41018PH: (859) 341-4709FIELD SPEC HOTLINE: (859) 341-4709COPYRIGHT ALL RIGHTS RESERVED FISCHER HOMES, Inc.JOB INFO:DATE: PERMIT: SIGN-OFF: CONSTRUCTION:REVISION:REVISION:REVISION:REVISION:HOME TYPE:PLAN:2/19/2019 2:24 PM# TLR010230000 ADAM SOLOMON3284 TAMERLANE PLACELELAND 57-442-LELAND COASTAL CLASSIC WITH BRICK & STONE CARMEL, IN23 05/2017 ----------------------------------------------------fieldspecchange@fischerhomes.comREVISED BY:----LORI SOLOMONSAPPHIRE TRADE SUPPORT sapphiretradepartners@fischerhomes.com Fischer Homes Indianapolis II, LLCD5.0 03/21/19 Adam Schriner