Loading...
HomeMy WebLinkAboutTLR 23 sewer10701 N. College Avenue Suite A Indianapolis, Indiana 46280 phone 317-8449200 fax 317-844-9203 www.trico.eco lResidenfial SANITARY SEWER PERMIT 999913180 Permit Type Final Subdivision Tallyn's Ridge Project WO 1256485796 Section Number Project Name Tallyn's Ridge Sec 1 Lot Number 23 Project Developer Platinum Properties Address Number 3284 Lift Station 23 12.6th Street Station Address 2 Treatment Plant MIX Street Tamerlane Place Parcel Acreage 0.37 City Carmel EDU in Gallons 310 Zip Code 46074 County Hamilton Local Sewer Charge - District Contribution 0.00 Builder Fischer Homes Indianapolis, L.P. Plan Review and Inspection 0.00 phone Number 317-348-2500 Application Fee 150.00 EDU Fee 1908.00 Owner Interceptor Fee _0_00 Phone Number Other Fees 0.00 Fees Due 20.5_8_.00 Occupant Invoice Number _ Phone Number PLEASE NOTE: Installation of building sewer shall be per the specifications of the TriCo Regional Sewer Utility (see reverse) and any conditions noted below. All installations shall be inspected by TriCo personnel during "open trench" phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundation drains, or other sources of ground or stormwateT, shall be permitted to enterTriCo's sanitary sewer system. TriCo will assume no liability for drains which are below the grade level of the nearest downstream manhole nor for laterals which are extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder) will be responsible for damages to TriCo's sewer system. This includes damages to manholes, castings, manhole lids and the like; caused by construction activity on the building site which is the subject of this permit. Inspections by TriCo are MANDATORY and shall be arranged by contacting TriCo's office at 844-9200 24 hours in advance. All new construction will be placed on billing two months after connection has been made or when water is connected, whichever comes first. The building has: Main ID: TAR803-TAR801 Grease Trap Slab Foundation ' Manhole @s USMH TAR -803 TAR -801 DSMH Grease Interceptor Crawl Space Grit Interceptor Basement YES Lid Elevation 920.79 920.82 Grinder Station First Floor Elevation 925.13 925.13 Water Service City of Carmel I Basement Elevation 916.00 916.00 Calculation is based on both Manhole Lid Elevations and the elevation of the First Floor 4.34 4.31 Ft. Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump Only TriCo currently requires that an I&I inspection is performed and a Certificate of Compliance is issued prior to occupancy / sale of properrty. Please review attached I/I Permit. Manholes shall remain accessible at all times. Buried manholes will be corrected by the Developerlowner. The proper class of cleanout must be installed every 100 feet of lateral pipe measured from sewer main to structure. T e terms of the conditional permit, if any, are listed below. Plans have been submitted. All fees have been paid. No certificate of insurance required. No additional permits required. No manhole core permit required. The facility is not classified as a FOG facility. (Notes)::::::41.1 - E- HAM1�10, By signing below, I attest th a 's eciflcations and agree to accept responsibility for all work done under thls ennit. Builder/ Owner Signature �Z Phone Number0 Printed Na Approved By / Ryan H/4ftr, V District Engineer _ _ 02/26/2019 Permit is valid for ON -YEAR from the date issued. Permit valid only with TriCo seal in red ink.