HomeMy WebLinkAboutTLR-023 ENERGYIECC 2009 Performance Compliance
Property Organization
3284 TAMERLANE PLACE TSI Energy Solutions
CARMEL, IN 46074 Devin Sielschott
TLR023 (AS DESIGNED) Builder
TALLYNS RIDGE 23 FISCHER HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$1,585
$218
$185
$1,988
$1,390
$0
$3,378
Requirements
C-M,
Energy Solutions
As Designed
$1,494
$216
$185
$1,896
$1,390
$0
$3,286
Z4405.3 Performance-based compliance passes by 4.6%
402.4.12 Air Leakage Testing Air sealing is 5.06 ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa
402.5 Area -weighted average fenestration SHGC
402.5 Area -weighted average fenestration U -Factor
Z4 403.2.2 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R405.2 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 4.6%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Cade based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and thatthe mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date:
2119/19 at 11:06 AM
Ekotrope RATER- Version 3.1.0.2112
IECC 2009 Performance compliance results calculated using Ekotrope's energy algorithm, which is a RESIVET Accredited HERS Rating Tool.
3284 TAMERLANE PLACE
CARMEL, IN 46074
FISCHER HOMES
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls R-10
Framed Floor R-30
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 5 ACH50
Window U -Value: 0.31, SHGC: 0.28
Building Features
Duct Supply R-6.0, Return R-6.0
Duct Leakage to Outside 280.0 CFM @ 25Pa
Total Duct Leakage 448.0 CFM @ 25Pa
Heating Furnace - Natural Gas - 96.1 AFUE
Cooling Air Conditioner - Electric - 13 SEER
Water Heating Water Heater - Natural Gas - 0.72 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedltested and
that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date:
2/19119 at 11:06 AM
Ekotrope RATER - Version 3.1.0.2112
No version of this software has been reviewed or approved by ICC or its affiliates_
The 2009 International Energy Conservation Code is a registered trademark ofthe International Code Council, Inc. ('ICC').
Th's software is a RESNETAccredited HERS Rating Tool.
Energy Cade Inspection Checklist
Property
3284 TAMERLANE PLACE
CARMEL, IN 46074
TLR023 (AS DESIGNED)
TALLYNS RIDGE 23
General Building Information
Conditioned Area (sq ft)
Conditioned Volume (cubic ft)
Insulated Shell Area (sq ft)
Organization
TSI Energy Solutions
Devin Sielschott
Builder
FISCHER HOMES
5,618
51,432
10,684
Inspection Status
Results are projected
C-M,
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
[ Name: BSMT (2,210 s.f.)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
[ Name: OVER GARAGE (359 s.f.)
R-0 continuous insulation, R-30 cavity insulation
Insulation Grade: I
Foundation Wall
El Name: CDNDIAMB (Exterior Perimeter [ft]: 179, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7)
R: 10.00
Fully insulated (top to bottom)
El Name: CONDIGAR (Exterior Perimeter [ft]: 42, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7)
R: 10.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
Above Grade Wall
Ej Name: CDNDIAMB (2,177 s.f.)
R-0.205 continuous insulation, R-15 cavity insulation
Insulation Grade: I
E[ Name: CDNDIAMB 2X6 (324 s.f.)
R-0.41 continuous insulation, R-19 cavity insulation 1
Insulation Grade: I
Energy Cade Inspection Checklist
Property Organization
3284 TAMERLANE PLACE TSI Energy Solutions
CARMEL, IN 46074 Devin Sielschott
TLR023 (AS DESIGNED) Builder
TALLYNS RIDGE 23 FISCHER HOMES
Name: CDNDIGAR (378 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Name: CDNDIATTIC (550 s.f.)
R-0.205 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Rim Joist
El Name: RIM CONDIAMB (179 s.f.)
R: 15.414
1� Name: BAND CONDJAMB (54 s.f.)
1--1 R: 15.414
Roof
Name: CDNDIGAR (42 s.f.)
R: 15.414
Name: CDNDIATTIC (57 s.f.)
R: 15.414
Name: SECOND (2,274 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Name: MR (312 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Opaque Door
El Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Inspection Status
Results are projected
C-M,
Energy Solutions
2
Energy Cade Inspection Checklist
C-M
Energy Solutions
Property Organization
3284 TAMERLANE PLACE TSI Energy Solutions
CARMEL, IN 46074 Devin Sielschott Inspection Status
Results are projected
TLR023 (AS DESIGNED) Builder
TALLYNS RIDGE 23 FISCHER HOMES
Glazing
El Name: FRONT (140 s.f.), U:0.310, SHGC: 0.28, Orientation: EAST
11 Name: BACK (121 s.f.), U:0.310, SHGC: 0.28, Orientation: WEST
L] Name: BACK 2X6 (106 s.f.), U:0.310, SHGC: 0.28, Orientation: WEST
Name: LEFT SIDE (8 s.f.), U:0.310, SHGC: 0.28, Orientation: SOUTH
E] Name: SLIDER (40 s.f.), U: 0.310, SHGC: 0.28, Orientation: SOUTH
L] Name: RIGHT (47 s.f.), U:0.310, SHGC: 0.28, Orientation: NORTH
E] Name: BACK BSMT (20 s.f.), U:0.310, SHGC: 0.28, Orientation: WEST
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
0 Fuel -fired air distribution • Natural Gas - 100% Heating Load @ 96.1 AFUE
J1 Air conditioner - Electric - 100% Cooling Load @ 13 SEER
El Water Heating - Natural Gas - 100% Hot Water Load @ 0.72 Energy Factor
Air Leakage Control
Test Status: Blower -door tested
House is air -sealed as to achieve 4,286 CFM50 (5.00 ACH50) or less at final blower -door test. 3
Energy Code Inspection Checklist
Property Organization
3284 TAMERLANE PLACE TSI Energy Solutions
CARMEL, IN 46074 Devin Sielschott Inspection Status
Results are projected
TLR023 (AS DESIGNED) Builder
TALLYNS RIDGE 23 FISCHER HOMES
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
Entirely within conditioned space
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 280.0 CFM @ 25Pa
Total Duct Leakage is specified in Ekotrope at 448.0 CFM @ 25Pa
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFR.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 1 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage a= 4 CFM251 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage a= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage a= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
3284 TAMERLANE PLACE
CARMEL, IN 46074
T LR023 (AS D ES IG N E D)
TALLYNS RIDGE 23
General Building In
Number Of Bedrooms
Number Of Floors
Conditioned Floor Area [sq. ft.]
Unconditioned; attached garage?
Conditioned Volume [cu. ft.]
Total Units in Building
Residence Type
Model
Community
Climate Zone
Basement Wali
Name Library type
Organization
TSI Energy Solutions
Devin Sielschott
Builder
FISCHER HOMES
4
2
5,618
Yes
51,432
1
Single family detached
LELAND(CC)
TALLYNS RIDGE 23
5A
Inspection Status
Results are projected
C-M,
Energy Solutions
ICONDIAMB R-10 Draped, Full 1 7 179 Exposed Exterior Conditioned Space
ICONDIGAR R-10 Draped, 4ft
1
7
42 Exposed Exterior Conditioned Space
Basement Wall Library List
Name Feet From Wall Top To
Insulation Feet From Wall Top Tb
Top
Insulation
Bottom
Is Fully Insulated R -value
R-10 Draped, 4ft
0
4
No 10.00
RA0Draped, Full
NIA
NIA
Yes 10.00
SIa
Name Library Type
Perimeter Floor Grade
Carpet R
Masonry
Exposed Surface Area Location Enclosing
Area
BSMT Uninsulated
221 Below Grade
0
0 2,210.0 sq. ft. Exposed Exterior Conditioned
Space
Slab Librar List
Name Wall Construction Type Slab Ccmpletely� Underslab Insulation Perimeter Insulation Perimeter Insulation R R -value
Insulated. Width [14 Depth [ft] Value
Uninsulated Wood Frame /Other No 0 0 D 0.00
1
Building Summary
Property) Organization
3284 TAMERLANE PLACE TSI Energy Solutions
CARMEL, IN 46074 Devin Sielschott
T LR023 (AS D ES IG N E D) Builder
TALLYNS RIDGE 23 FISCHER HOMES
Framed Floor
Name Library type Car
OVER GARAGE R-30, GRI
Framed Floor Library List
Name R -value
R-30, GR1 27.493
Rim Joist
Name
BAND CONDIAMB
CONDIATTIC
CONDI GAR
RIM CONDIAMB
Rim Joist Library List
Name
G1 R-19. OSB
CTSI
Energy Solutions
Inspection Status
Results are projected
ret R Floor Grade SurlaceArea Location
123 Above Grade 359.0 sq. ft. Unconditioned, attached
garage
Library type Surface Area Locatinr
G1 R-19, OSB 54.0 sq. R. Exposed Exterior
GI R-19, OSB 57.0 sq. ft. Attic
G1 R-19, OSB
G1 R-19, OSB
Name Library Type
CONDIAMB G1 R-15 BATT, T -PLY
CONDIAMB 2X6 G1 R-19 BATT, T -PLY
CONDIATTIC G1 R-15 BATT. T -PLY
R -value
15.414
:e Colo
Medium
Medium
Medium
42.0 sq. ft. Unconditioned, attached garage
179.0 sq. ft.
2,177.0 sq. ft.
324.0 sq. ft.
550.0 sa. ft.
Exposed Exterior
Location
Exposed Exterior
Exposed Exterior
Attic
2
Building Summary
C-M
Energy Solutions
Property Organization
3284 TAMERLANE PLACE TSI Energy Solutions
CARMEL, IN 46074 Devin Sielschott
Inspection Status
TLR023 (AS DESIGNED) Builder Results are projected
TALLYNS RIDGE 23 FISCHER HOMES
Name Library type Surface Color Surface Area Location
CONDIGAR G1 R-15 Gar Walls Medium 378.0 sq. ft. Unconditioned, attached garage
Wall Library List
Name R -value
G1 R-15 BATT, T -PLY 12.842
G1 R-15 Gar Walls 11.972
G1 R-19 BATT, T -PLY 17278
Glazing
Name Library type Wall Assignment Basement Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area
Assignment Tap Bottom
BACK U-.31, SHGC-28 CONDIAMB ❑ 0 0 West 121 -0 sq. ft.
BACK 2X6 U-.31, SHGC-28 CON DIAMB 2X6 0 0 0 West 106.0 sq. ft.
BACK BSMT U-.31, SHGC-28 CONDIAMB 0 0 0 West 20.0 sq. ft.
FRONT U-.31, SHGC-28 CONDIAMB 0 0 0 East 140.0 sq. ft.
LEFT SIDE U-.31, SHGC-.28 CONDIAMB 0 0 0 South 8.0 sq. ft.
RIGHT U-31, SHGC-.28 CONDIAMB 0 0 0 North 47.0 sq. ft.
SLIDER U-.31, SHGC-28 CONDIAMB 0 0 0 South 40.0 sq. ft.
Glazing Library List
Name Shgc U -factor
U-.31, SHGC-.28 D28 0.310
Skylight
None Present
3
Building Summary
Property
3284 TAMERLANE PLACE
CARMEL, IN 46074
T LR023 (AS D ES IG N E D)
TALLYNS RIDGE 23
Skylight Library List
Organization
TSI Energy Solutions
Devin Sielschott
Builder
FISCHER HOMES
Inspection Status
Results are projected
C-M,
Energy Solutions
Opaque Door
Name Library Type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location
Assignment Ab so rp to n ce
FRONT Fiberglass/Steel CONDIAMB 0.9 0.75 Medium 20.0 sq. 11 Exposed Exterior
Door
GARAGE Fiberglass/Steel
Door
Opaque Door Library List
Name
FiherglasslSteel Door
Roof Insulation
CONDIGAR 0.9 0.75 Medium 18.0 sq. 11 Exposed Exterior
0.7 82
Name Library lype Attic Exterior Area Clay or Concrete Roof
P.f.] Tiles
MR R-38 Vaulted, GR1 312 No
SECOND R-38 Blown, GR1 2,274 No
Roof Insulation Library List
i
Name Has Radiant Barrier
R-38 Blown, GRI NC
R38 Vaulted, GR1 No
1
Surface Color
Surface Area Location
Medium
312.0 sq. 11 Vaulted Roof
Medium
2,274.0 sq. 11 Attic
38268
32263
4
Building Summary
Property)
C-MEnergy Solutions
Organization
3284 TAMERLANE PLACE
TSI Energy Solutions
CARMEL, IN 46074
Devin Sielschott
Inspection Status
TLR023 (AS DESIGNED)
Builder Results are projected
TALLYNS RIDGE 23
FISCHER HOMES
Whole House Infiltration
Infiltration Measurement type Shelter Glass
5 ACH at 50 Pa Blower -door tested 4
Mechanical Ventilation
None Present
Lighting
Interior Fluorescent I Interior LED Lighting I Exterior Fluorescent I Exterior LED Lighting I Garage Fluorescent I Garage LED Lighting
Lighting Lighting Lighting
C a 0 0 0 a
Onsite Generation
None Present
Onsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
5
Building Summary
Property
Organization
3284 TAMERLANE PLACE
TSI Energy Solutions
CARMEL, IN 46074
Devin Sielschott
T LR023 (AS D ES IG N E D)
Builder
TALLYNS RIDGE 23
FISCHER HOMES
nditioning Equipment
Name
Library type H
Air conditioner
GSX130421A
Fuel -fired air
Distribution Type
GMSS960803BN
distribution
PSC (Single Speed)
Water Heating
GPVL-50-200
Cooling Capacity [kBtulh]
Equipment Type: GMSS960803BN
ME=
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
96.1 AFUE
Heating Capacity [kBtulh]
77
Use default EAE
No
EAE [kWh]
754
Equipment Type: GPVL-50-200
Fuel Type
Natural Gas
Distribution Type
Hydronic Delivery
Hot Water Efficiency
0.72 Energy Factor
Tank Capacity (gal.)
50
Hot Water Capacity [kBtulh]
40
Recovery Efficiency
0.80
Equipment Type: GSX130421A
=
Fuel Type
Electric
Distribution Type
Forced Air
Motor Type
PSC (Single Speed)
Cooling Efficiency
13 SEER
Cooling Capacity [kBtulh]
40
Inspection Status
Results are projected
0% 100%
100% 0%
C-M,
Energy Solutions
0%
0%
0% 0% 100%
X
Building Summary
Property)
Organization
3284 TAMERLANE PLACE
TSI Energy Solutions
CARMEL, IN 46074
Devin Sielschott
T LR023 (AS D ES IG N E D)
Builder
TALLYNS RIDGE 23
FISCHER HOMES
Distribution System
Distribution Type
Forced Air
Heating Equipment
Fuel -fired air distribution
Cooling Equipment
Air conditioner
Sq. Feet Served
5618
# Return Grilles
4
Supply Duct R Value
6
Return Duct R Value
6
Supply Duct Area [sq. ft.]
151686
Return Duct Area [sq. ft]
1123.6
Duct Leakage to Outdoors (CFM25)
280
Total Leakage
448
Total Leakage Dud Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Conditioned Space
Percent Supply Area
100
Percent Return Area
100
Duct 2
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
rHasCeilingan No
166
Water Distribution J&
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
75
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft]
20
Drain Water Heat Recovery?
No
Inspection Status
Results are projected
C-M,
Energy Solutions
Building Summary
Property
3284 TAMERLANE PLACE
CARMEL, IN 46074
T LR023 (AS D ES IG N E D)
TALLYNS RIDGE 23
Clothes Dryer
Fuel Type
Cef
Field Utilization
Organization
TSI Energy Solutions
Devin Sielschott
Inspection Status
Builder Results are projected
FISCHER HOMES
Electric
2.617
Timer Controls
asher �&W
Label Energy Rating
704 kWh/Year
Electric Rate
$0.08lkWh
Annual Gas Cost
$23.00
Gas Rate
$0.58frherm
Capacity
2.874
Imef
0.331
Appliances and Controls
Programmable thermostat?
Yes
Dishwasher Size
Standard
Dishwasher Efficiency
270 kWh
Range/Oven Fuel
Natural Gas
Convection Oven?
No
Induction Range?
No
Refrigerator Consumption
709 kVVh/Year
7
C-M,
Energy Solutions