Loading...
HomeMy WebLinkAboutTLR-023 ENERGYIECC 2009 Performance Compliance Property Organization 3284 TAMERLANE PLACE TSI Energy Solutions CARMEL, IN 46074 Devin Sielschott TLR023 (AS DESIGNED) Builder TALLYNS RIDGE 23 FISCHER HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,585 $218 $185 $1,988 $1,390 $0 $3,378 Requirements C-M, Energy Solutions As Designed $1,494 $216 $185 $1,896 $1,390 $0 $3,286 Z4405.3 Performance-based compliance passes by 4.6% 402.4.12 Air Leakage Testing Air sealing is 5.06 ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U -Factor Z4 403.2.2 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R405.2 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 4.6%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Cade based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and thatthe mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 2119/19 at 11:06 AM Ekotrope RATER- Version 3.1.0.2112 IECC 2009 Performance compliance results calculated using Ekotrope's energy algorithm, which is a RESIVET Accredited HERS Rating Tool. 3284 TAMERLANE PLACE CARMEL, IN 46074 FISCHER HOMES Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls R-10 Framed Floor R-30 Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U -Value: 0.31, SHGC: 0.28 Building Features Duct Supply R-6.0, Return R-6.0 Duct Leakage to Outside 280.0 CFM @ 25Pa Total Duct Leakage 448.0 CFM @ 25Pa Heating Furnace - Natural Gas - 96.1 AFUE Cooling Air Conditioner - Electric - 13 SEER Water Heating Water Heater - Natural Gas - 0.72 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedltested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 2/19119 at 11:06 AM Ekotrope RATER - Version 3.1.0.2112 No version of this software has been reviewed or approved by ICC or its affiliates_ The 2009 International Energy Conservation Code is a registered trademark ofthe International Code Council, Inc. ('ICC'). Th's software is a RESNETAccredited HERS Rating Tool. Energy Cade Inspection Checklist Property 3284 TAMERLANE PLACE CARMEL, IN 46074 TLR023 (AS DESIGNED) TALLYNS RIDGE 23 General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Organization TSI Energy Solutions Devin Sielschott Builder FISCHER HOMES 5,618 51,432 10,684 Inspection Status Results are projected C-M, Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab [ Name: BSMT (2,210 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor [ Name: OVER GARAGE (359 s.f.) R-0 continuous insulation, R-30 cavity insulation Insulation Grade: I Foundation Wall El Name: CDNDIAMB (Exterior Perimeter [ft]: 179, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7) R: 10.00 Fully insulated (top to bottom) El Name: CONDIGAR (Exterior Perimeter [ft]: 42, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7) R: 10.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Above Grade Wall Ej Name: CDNDIAMB (2,177 s.f.) R-0.205 continuous insulation, R-15 cavity insulation Insulation Grade: I E[ Name: CDNDIAMB 2X6 (324 s.f.) R-0.41 continuous insulation, R-19 cavity insulation 1 Insulation Grade: I Energy Cade Inspection Checklist Property Organization 3284 TAMERLANE PLACE TSI Energy Solutions CARMEL, IN 46074 Devin Sielschott TLR023 (AS DESIGNED) Builder TALLYNS RIDGE 23 FISCHER HOMES Name: CDNDIGAR (378 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Name: CDNDIATTIC (550 s.f.) R-0.205 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Joist El Name: RIM CONDIAMB (179 s.f.) R: 15.414 1� Name: BAND CONDJAMB (54 s.f.) 1--1 R: 15.414 Roof Name: CDNDIGAR (42 s.f.) R: 15.414 Name: CDNDIATTIC (57 s.f.) R: 15.414 Name: SECOND (2,274 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Name: MR (312 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Opaque Door El Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Inspection Status Results are projected C-M, Energy Solutions 2 Energy Cade Inspection Checklist C-M Energy Solutions Property Organization 3284 TAMERLANE PLACE TSI Energy Solutions CARMEL, IN 46074 Devin Sielschott Inspection Status Results are projected TLR023 (AS DESIGNED) Builder TALLYNS RIDGE 23 FISCHER HOMES Glazing El Name: FRONT (140 s.f.), U:0.310, SHGC: 0.28, Orientation: EAST 11 Name: BACK (121 s.f.), U:0.310, SHGC: 0.28, Orientation: WEST L] Name: BACK 2X6 (106 s.f.), U:0.310, SHGC: 0.28, Orientation: WEST Name: LEFT SIDE (8 s.f.), U:0.310, SHGC: 0.28, Orientation: SOUTH E] Name: SLIDER (40 s.f.), U: 0.310, SHGC: 0.28, Orientation: SOUTH L] Name: RIGHT (47 s.f.), U:0.310, SHGC: 0.28, Orientation: NORTH E] Name: BACK BSMT (20 s.f.), U:0.310, SHGC: 0.28, Orientation: WEST Skylight None Present Mechanical Ventilation None Present Mechanical Equipment 0 Fuel -fired air distribution • Natural Gas - 100% Heating Load @ 96.1 AFUE J1 Air conditioner - Electric - 100% Cooling Load @ 13 SEER El Water Heating - Natural Gas - 100% Hot Water Load @ 0.72 Energy Factor Air Leakage Control Test Status: Blower -door tested House is air -sealed as to achieve 4,286 CFM50 (5.00 ACH50) or less at final blower -door test. 3 Energy Code Inspection Checklist Property Organization 3284 TAMERLANE PLACE TSI Energy Solutions CARMEL, IN 46074 Devin Sielschott Inspection Status Results are projected TLR023 (AS DESIGNED) Builder TALLYNS RIDGE 23 FISCHER HOMES Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 Entirely within conditioned space Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 280.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 448.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFR. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 1 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage a= 4 CFM251 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage a= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage a= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property 3284 TAMERLANE PLACE CARMEL, IN 46074 T LR023 (AS D ES IG N E D) TALLYNS RIDGE 23 General Building In Number Of Bedrooms Number Of Floors Conditioned Floor Area [sq. ft.] Unconditioned; attached garage? Conditioned Volume [cu. ft.] Total Units in Building Residence Type Model Community Climate Zone Basement Wali Name Library type Organization TSI Energy Solutions Devin Sielschott Builder FISCHER HOMES 4 2 5,618 Yes 51,432 1 Single family detached LELAND(CC) TALLYNS RIDGE 23 5A Inspection Status Results are projected C-M, Energy Solutions ICONDIAMB R-10 Draped, Full 1 7 179 Exposed Exterior Conditioned Space ICONDIGAR R-10 Draped, 4ft 1 7 42 Exposed Exterior Conditioned Space Basement Wall Library List Name Feet From Wall Top To Insulation Feet From Wall Top Tb Top Insulation Bottom Is Fully Insulated R -value R-10 Draped, 4ft 0 4 No 10.00 RA0Draped, Full NIA NIA Yes 10.00 SIa Name Library Type Perimeter Floor Grade Carpet R Masonry Exposed Surface Area Location Enclosing Area BSMT Uninsulated 221 Below Grade 0 0 2,210.0 sq. ft. Exposed Exterior Conditioned Space Slab Librar List Name Wall Construction Type Slab Ccmpletely� Underslab Insulation Perimeter Insulation Perimeter Insulation R R -value Insulated. Width [14 Depth [ft] Value Uninsulated Wood Frame /Other No 0 0 D 0.00 1 Building Summary Property) Organization 3284 TAMERLANE PLACE TSI Energy Solutions CARMEL, IN 46074 Devin Sielschott T LR023 (AS D ES IG N E D) Builder TALLYNS RIDGE 23 FISCHER HOMES Framed Floor Name Library type Car OVER GARAGE R-30, GRI Framed Floor Library List Name R -value R-30, GR1 27.493 Rim Joist Name BAND CONDIAMB CONDIATTIC CONDI GAR RIM CONDIAMB Rim Joist Library List Name G1 R-19. OSB CTSI Energy Solutions Inspection Status Results are projected ret R Floor Grade SurlaceArea Location 123 Above Grade 359.0 sq. ft. Unconditioned, attached garage Library type Surface Area Locatinr G1 R-19, OSB 54.0 sq. R. Exposed Exterior GI R-19, OSB 57.0 sq. ft. Attic G1 R-19, OSB G1 R-19, OSB Name Library Type CONDIAMB G1 R-15 BATT, T -PLY CONDIAMB 2X6 G1 R-19 BATT, T -PLY CONDIATTIC G1 R-15 BATT. T -PLY R -value 15.414 :e Colo Medium Medium Medium 42.0 sq. ft. Unconditioned, attached garage 179.0 sq. ft. 2,177.0 sq. ft. 324.0 sq. ft. 550.0 sa. ft. Exposed Exterior Location Exposed Exterior Exposed Exterior Attic 2 Building Summary C-M Energy Solutions Property Organization 3284 TAMERLANE PLACE TSI Energy Solutions CARMEL, IN 46074 Devin Sielschott Inspection Status TLR023 (AS DESIGNED) Builder Results are projected TALLYNS RIDGE 23 FISCHER HOMES Name Library type Surface Color Surface Area Location CONDIGAR G1 R-15 Gar Walls Medium 378.0 sq. ft. Unconditioned, attached garage Wall Library List Name R -value G1 R-15 BATT, T -PLY 12.842 G1 R-15 Gar Walls 11.972 G1 R-19 BATT, T -PLY 17278 Glazing Name Library type Wall Assignment Basement Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area Assignment Tap Bottom BACK U-.31, SHGC-28 CONDIAMB ❑ 0 0 West 121 -0 sq. ft. BACK 2X6 U-.31, SHGC-28 CON DIAMB 2X6 0 0 0 West 106.0 sq. ft. BACK BSMT U-.31, SHGC-28 CONDIAMB 0 0 0 West 20.0 sq. ft. FRONT U-.31, SHGC-28 CONDIAMB 0 0 0 East 140.0 sq. ft. LEFT SIDE U-.31, SHGC-.28 CONDIAMB 0 0 0 South 8.0 sq. ft. RIGHT U-31, SHGC-.28 CONDIAMB 0 0 0 North 47.0 sq. ft. SLIDER U-.31, SHGC-28 CONDIAMB 0 0 0 South 40.0 sq. ft. Glazing Library List Name Shgc U -factor U-.31, SHGC-.28 D28 0.310 Skylight None Present 3 Building Summary Property 3284 TAMERLANE PLACE CARMEL, IN 46074 T LR023 (AS D ES IG N E D) TALLYNS RIDGE 23 Skylight Library List Organization TSI Energy Solutions Devin Sielschott Builder FISCHER HOMES Inspection Status Results are projected C-M, Energy Solutions Opaque Door Name Library Type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location Assignment Ab so rp to n ce FRONT Fiberglass/Steel CONDIAMB 0.9 0.75 Medium 20.0 sq. 11 Exposed Exterior Door GARAGE Fiberglass/Steel Door Opaque Door Library List Name FiherglasslSteel Door Roof Insulation CONDIGAR 0.9 0.75 Medium 18.0 sq. 11 Exposed Exterior 0.7 82 Name Library lype Attic Exterior Area Clay or Concrete Roof P.f.] Tiles MR R-38 Vaulted, GR1 312 No SECOND R-38 Blown, GR1 2,274 No Roof Insulation Library List i Name Has Radiant Barrier R-38 Blown, GRI NC R38 Vaulted, GR1 No 1 Surface Color Surface Area Location Medium 312.0 sq. 11 Vaulted Roof Medium 2,274.0 sq. 11 Attic 38268 32263 4 Building Summary Property) C-MEnergy Solutions Organization 3284 TAMERLANE PLACE TSI Energy Solutions CARMEL, IN 46074 Devin Sielschott Inspection Status TLR023 (AS DESIGNED) Builder Results are projected TALLYNS RIDGE 23 FISCHER HOMES Whole House Infiltration Infiltration Measurement type Shelter Glass 5 ACH at 50 Pa Blower -door tested 4 Mechanical Ventilation None Present Lighting Interior Fluorescent I Interior LED Lighting I Exterior Fluorescent I Exterior LED Lighting I Garage Fluorescent I Garage LED Lighting Lighting Lighting Lighting C a 0 0 0 a Onsite Generation None Present Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present 5 Building Summary Property Organization 3284 TAMERLANE PLACE TSI Energy Solutions CARMEL, IN 46074 Devin Sielschott T LR023 (AS D ES IG N E D) Builder TALLYNS RIDGE 23 FISCHER HOMES nditioning Equipment Name Library type H Air conditioner GSX130421A Fuel -fired air Distribution Type GMSS960803BN distribution PSC (Single Speed) Water Heating GPVL-50-200 Cooling Capacity [kBtulh] Equipment Type: GMSS960803BN ME= Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 96.1 AFUE Heating Capacity [kBtulh] 77 Use default EAE No EAE [kWh] 754 Equipment Type: GPVL-50-200 Fuel Type Natural Gas Distribution Type Hydronic Delivery Hot Water Efficiency 0.72 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 40 Recovery Efficiency 0.80 Equipment Type: GSX130421A = Fuel Type Electric Distribution Type Forced Air Motor Type PSC (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 40 Inspection Status Results are projected 0% 100% 100% 0% C-M, Energy Solutions 0% 0% 0% 0% 100% X Building Summary Property) Organization 3284 TAMERLANE PLACE TSI Energy Solutions CARMEL, IN 46074 Devin Sielschott T LR023 (AS D ES IG N E D) Builder TALLYNS RIDGE 23 FISCHER HOMES Distribution System Distribution Type Forced Air Heating Equipment Fuel -fired air distribution Cooling Equipment Air conditioner Sq. Feet Served 5618 # Return Grilles 4 Supply Duct R Value 6 Return Duct R Value 6 Supply Duct Area [sq. ft.] 151686 Return Duct Area [sq. ft] 1123.6 Duct Leakage to Outdoors (CFM25) 280 Total Leakage 448 Total Leakage Dud Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 100 Percent Return Area 100 Duct 2 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 3 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ rHasCeilingan No 166 Water Distribution J& Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 75 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 20 Drain Water Heat Recovery? No Inspection Status Results are projected C-M, Energy Solutions Building Summary Property 3284 TAMERLANE PLACE CARMEL, IN 46074 T LR023 (AS D ES IG N E D) TALLYNS RIDGE 23 Clothes Dryer Fuel Type Cef Field Utilization Organization TSI Energy Solutions Devin Sielschott Inspection Status Builder Results are projected FISCHER HOMES Electric 2.617 Timer Controls asher �&W Label Energy Rating 704 kWh/Year Electric Rate $0.08lkWh Annual Gas Cost $23.00 Gas Rate $0.58frherm Capacity 2.874 Imef 0.331 Appliances and Controls Programmable thermostat? Yes Dishwasher Size Standard Dishwasher Efficiency 270 kWh Range/Oven Fuel Natural Gas Convection Oven? No Induction Range? No Refrigerator Consumption 709 kVVh/Year 7 C-M, Energy Solutions