HomeMy WebLinkAboutASHMOOR 10 - AM010 (AS DESIGNED)IECC 2009 Performance Compliance
Property
3445 YANCEY PL
CARMEL, IN 46074
AM010 (AS DESIGNED)
ASHMOOR 10
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$2,516
$370
$449
$3,335
$1,208
50
$4,542
Requirements
C4405.3
Performance-based compliance passes by 3.9%
402.4.1.2
Air Leakage Testing
402.5
Area -weighted average fenestration SHGC
402.5
Area -weighted average fenestration U -Factor
40322
Duct. Testing
C4
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052
Duct Insulation
CTSI
Energy Solutions
As Designed
52,426
5330
5449
$3,204
S1,208
50
$4,412
Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa.
Design exceeds requirements for IECC 2009 Performance compliance by 3.9%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
217119 at 8:58 AM
Ekotrope RATER - Version 3.1.0.2105
IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool.
3445 YANCEY PL
CARMEL, IN 46074
LENNAR HOMES
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls R-11
Framed Floor NIA
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 5 ACH50
Window U -Value: 0.32, SHGC: 0.31
Building Features
Duct Supply R-30.0, Return R-30.0
Duct Leakage to Outside 453.0 CFM @ 25Pa
Total Duct Leakage 605.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 95.5 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 217119 at 8:58 AM
Ekotrope RATER - Version 3.1.0.2105
No version of this software has been reviewed or approved by ICC or its affiliates.
The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC').
This software is a RESIN ETAccredited HERS Rating Tool.
Energy Code Inspection Checklist
Property
3445 YANCEY PL
CARMEL, IN 46074
AM010 (AS DESIGNED)
ASHMOOR 10
General Building Information
Conditioned Area (sq ft)
Conditioned Volume (cubic ft)
Insulated Shell Area (sq ft)
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
7,562
73,366
13,624
Inspection Status
Results are projected
C-M,
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identity any changes and ensure
that the home continues to meet the applicable energy code.
Slab
] Name: BSMT (3,114 s.f.)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
None Present
Foundation Wall
] Name: CONDIAMB (Exterior Perimeter [ft]: 206, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
]l Name: CONDIGAR (Exterior Perimeter [ft]: 82, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
Alcove Grade Wall
El Name: COND/AMB (2,162 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CONDIAMB 2X6 (600 s.f.)
R-3 continuous insulation, R-19 cavity insulation
Insulation Grade: I
]l Name: CONDfGAR (820 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property Organization
3445 YANCEY PL TSI Energy Solutions
CARMEL, IN 46074 Matthew Timmons
AM010 (AS DESIGNED) Builder
ASHMOOR 10 LENNAR HOMES
Name: CONDIATTIC (748 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
El Name: CONDIAMB (272 s.f.)
R: 13.575
Name: CONDIGAR (82 s.f.)
R: 10.876
El Name: CONDIATTIC (72 s.f.)
R: 13.575
Roof
Name: MAIN (2,922 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
El Name: SLOPED (240 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Opaque Door
El Name: FRONT (24 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
El Name: FRONT (196 s.f.), U:0.320, SHGC: 0.28, Orientation: SOUTH
El Name: BACK (66 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH
C",
Energy Solutions
2
Energy Code Inspection Checklist
C-M
Energy Solutions
Property Organization
3445 YANCEY PL TSI Energy Solutions
CARMEL, IN 46074 Matthew Timmons Inspection Status
Results are projected
AM010 (AS DESIGNED) Builder
ASHMOOR 10 LENNAR HOMES
E] Name: BACK 2X6 (154 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH
E] Name: BACK GD (18 s.f.), U:0.290, SHGC: 0.33, Orientation: NORTH
E] Name: BACK BSMT (16 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH
El Name: RIGHT SIDE (30 s.f.), U:0.320, SHGC: 0.31, Orientation: EAST
El Name: RIGHT SIDE 2X6 (15 s.f.), U:0.320, SHGC: 0.31, Orientation: EAST
El Name: LEFT SIDE (102 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST
11 Name: LEFT SIDE 2X6 (18 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST
El Name: LEFT GD (18 s.f.), U:0.290, SHGC: 0.33, Orientation: WEST
Name: LEFT BSMT (16 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
El Fuel -fired air distribution [1) • Natural Gas • 100% Heating Load @ 95.5 AFUE
E] Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER
Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
3
Test Status: Blower -door tested
House is air -sealed as to achieve 6,114 CFM50 (5.00 ACH50) or less at final blower -door test.
Energy Code Inspection Checklist
Property
3445 YANCEY PL
CARMEL, IN 46074
AM010 (AS DESIGNED)
ASHMOOR 10
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Infiltration Requirements for IECC in Climate Zone 5
Inspection Status
Results are projected
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 453.0 CFM @ 25 Pa
Total Duct Leakage is specified in Ekotrope at 605.0 CFM @ 25Pa
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
C-M
Energy Solutions
Property Organization
3445 YANCEY PL TSI Energy Solutions
CARMEL, IN 46074 Matthew Timmons
Inspection Status
AM010 [AS DESIGNED] Builder Results are projected
ASHMOOP 10 LENNAR HOMES
General Building Information
MM
Number Of Bedrooms 5
Number Of Floors 2
Conditioned Floor Area [sq. ft.] 7;562
Unconditioned, attached garage? Yes
Conditioned Volume [cu. ft.] 73;366
Total Units in Building 1
Residence Type Single family detached
Model PARKSIDE (B)
Community ASHMOOR 10
Climate Zone 5A
Basement Wall
Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing
CONDIAMB R-11 Draped, Oft 1 8 2D6 Exposed Exterior Conditioned Space
CONDIGAR R-11 Draped, Oft 1 8 82 Exposed Exterior Conditioned Space
Basement Wall Library List
Name Feet From Wall Tap To Insulation Feet From Wall Top Tb Insulation Is Fully Insulated R -value
Tap Bottom
R-11 Draped, Oft 0 4 No 11.00
Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing
Masonry Area
BSMT Uninsulated 288 Below Grade ❑ 0 3,114.0 sq. fL Exposed Exterior Conditioned
Space
Slab Library List
Name Wall C
Uninsulated Wood Frame / Other No ❑ 0 D 0.00
1
Building Summary
Property Organization
3445 YANCEY PL TSI Energy Solutions
CARMEL, IN 46074 Matthew Timmons
AM010 [AS DESIGNED] Builder
ASHMOOP 10 LENNAR HOMES
ramed Floor
None Present
Framed Floor Library List
Rim Joist
Name
CONDIAMB
CONDIATTIC
C O N DIGAR
Rim Joist Library List
Name
G1 R-13,0813
G1 R-13, R-3.0
Library 7yp(
G1 R-13, R-3.0
Inspection Status
Results are projected
urface Area
272.0 sq. ft.
TSI Energy Solutions
Locatior
Exposed Exterior
G1 R-13, R-3.0 72.0 sq. ft. Attic
G1 R-13, OSB
2 -Value
10.876
13.575
82.0 sq. ft. Unconditioned, attached garage
2
Name
Library Type
Surface Calor
Surface Area
Location
CONDIAMB
G1 R-13 BATT, R-3.0
Medium
2.162.0 sq. ft.
Exposed Exterior
CONDIAMB 2X6
G1 R-19, R-3.0 2X6
Medium
600.0 sq. ft.
Exposed Exterior
CONDIATTIC
G1 R-13 BATT, R-3.0
Medium
748.0 sq. ft.
Attic
CONDIGAR
G1 R-13 Gar Walls
Medium
8200.sq. ft.
Unconditioned, attached garage
2
Building Summary
Property
3445 YANCEY PL
CARMEL, IN 46074
AM010 [AS DESIGNED]
ASHMOOP10
brary List AA
Name
G1 R-13 BATT, R-3.0
G1 R-13 Gar Walls
G1 R-19, R-3.0 2X6
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
20217
Inspection Status
Results are projected
C-M,
Energy Solutions
Glazing
Name Library type Wall Assignment
Basement Wall Overhang Depth
Assignment
Overhang Ft To
Top
Overhang Ft To
Bottom
Orientation
Surface Area
BACK
U-.32, SHGC-.31
CONDIAMB
0
0
0
North
66.0 sq. ft
BACK 2X6
U-.32, SHGG.31
CONDIAMB 2X6
0
0
0
North
154.0 sq. ft.
BACK BSMT
U-.32, SHGG.31
CONDIAMB
0
0
0
North
16.0 sq. fL
BACK GD
U-29, SHGG.33
CONDIAMB 2716
0
0
0
North
18.0 sq. ft
FRONT
U-.32, SHGG28
CONDIAMB
0
0
0
South
1960.sq. R.
LEFT BSMT
U-.32, SHGG.31
CONDIAMB
0
0
0
West
16.0 sq. 1
LEFT GD
U-29, SHGG.33
CONDIAMB
0
0
0
West
18.0 sq. R
LEFT SIDE
U-.32, SHGG.31
CONDIAMB
0
0
❑
West
102.0 sq. ft.
LEFT SIDE 2X6
U-.32, SHGG.31
CONDIAMB 2X6
0
0
❑
West
18.0 sq. fL
RIGHT SIDE
U-.32, SHGG.31
CONDIAMB
0
0
❑
East
30.0 sq. fL
RIGHT SIDE 2X6
U-.32, SHGG.31
CONDIAMB 2X6
0
0
❑
East
15.0 sq. fL
Glazing Library List
Name
U-29, SHGC-.33
U-.32, SHGC-28
U-.32, SHGC-.31
Singe
U #actor
0.33 0.290
028 0.320
0.31 0.320
9
Building Summary
Property
3445 YANCEY PL
CARMEL, IN 46074
AM010 [AS DESIGNED]
ASHMOOP10
kylight J
Skylight Library List
Opaque Door
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
C-M,
Energy Solutions
Name Library Type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location
Assignment Ab sorpta n ce
FRONT Steel Door CONDIAMB 0.9 0.75 Medium 24.0 sq. ft Exposed Exterior
GARAGE Steel Door CONDIGAR 0.9 0.75 Medium 18.0 sq. ft Exposed Exterior
Opaque Door Library List
Name
Steel Door
Roof Insulation
U -factor
0.182
Name Library Type
Attic Exterior Area
Cray or Concrete Roof Surface Color
Surface Area Location
P.f.]
Tiles
MAIN R-38 Blown, GR1
2,922
No Medium
2,922.0 sq. ft Attic
SLOPED R-38 Vaulted, GR1
240
No Medium
240.0 sq. 1 Vaulted Roof
Roof Insulation Library List
Name Has
R-38 Blown, GR1
R-38 Vaulted, GR1
No 38.268
No 32263
4
Building Summary
Property
3445 YANCEY PL
CARMEL, IN 46074
AM010 [AS DESIGNED]
ASHMOOP10
I Whole House Infiltration
Infiltration
I5 ACH at 50 Pa
1
Mechanical Ventilation
Organization
TSI Energy Solutions
Matthew Timmons
Inspection Status
Builder Results are projected
LENNAR HOMES
Blower -door tested 4
None Present
C-M,
Energy Solutions
Lighting
% Interior Fluorescent % Interior LED Lighting I Exterior Fluorescent % Exterior LED Lighting I Garage Fluorescent % Garage LED Lighting
Lighting Lighting Lighting
C
100
Onsite Generation W IL
None Present
Onsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
0
100
0
100
A
Building Summary
Property
Organization
3445 YANCEY PL
TSI Energy Solutions
CARMEL, IN 46074
Matthew Timmons
AM010 [AS DESIGNED]
Builder
ASHMOOP 10
LENNAR HOMES
Inspection Status
Results are projected
conditioning Equipment
Name Library Type Heating Percent Load
Air conditioner (2) CA13NA042 0%
C-M,
Energy Solutions
g Percent LOW Hot water
icc%
I Fuel -fired air 915SA42100S21 100% G°o
distribution (1)
IWater Heating (3) RE350" 0% X11%
1
Equipment Type: 915SA4210OS21
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
95.5 AFUE
Heating Capacity [kBtulh]
97
Use default EAE
No
EAE [kWh]
1;205
Equipment Type: CA13NA042
Fuel Type
Distribution Type
Motor Type
Cooling Efficiency
Cooling Capacity [kBtulh]
Equipment Type: RE350*
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity (gal.)
Hot Water Capacity [kBtulh]
Recovery Efficiency
Electric
Forced Air
PSG (Single Speed)
13 SEER
40
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
0.98
0%
0%
100%
Building Summary
Property
Organization
3445 YANCEY PL
TSI Energy Solutions
CARMEL, IN 46074
Matthew Timmons
Sq. Feet Served
Inspection Status
AM010 [AS DESIGNED]
Builder Results are projected
ASHMOOP 10
LENNAR HOMES
istribution System
Distribution Type
Forced Air
Heating Equipment
Fuel -f red air distribution [1)
Cooling Equipment
Air conditioner (2)
Sq. Feet Served
7562
# Return Grilles
8
Supply Duct R Value
30
Return Duct R Value
30
Supply Duct Area [sq. ft.]
1531.3
Return Duct Area [sq. ft_]
1417.9
Duct Leakage to Outdoors (CFM25)
453
Total Leakage
605
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Conditioned Space
Percent Supply Area
60
Percent Return Area
60
Duct 2
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
40
Percent Return Area
40
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Ceiling Fan
'
Has Ceiling Fan
No
Cfm Per Watt
101
Water Distribution
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
107
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft]
34
Drain Water Heat Recovery?
No
C-M,
Energy Solutions
Building Summary
Property
3445 YANCEY PL
CARMEL, IN 46074
AM010 [AS DESIGNED]
ASHMOOP10
Organization
TSI Energy Solutions
Matthew Timmons
Inspection Status
Builder Results are projected
LENNAR HOMES
lothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I mef
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
"M
704 kWh/Year
0.0nWh
$23.00
$0.581Therm
2.874
0.331
Yes
Standard
270 kWh
Electric
No
No
709 kWh/Year
C-M,