Loading...
HomeMy WebLinkAboutASHMOOR 10 - AM010 (AS DESIGNED)IECC 2009 Performance Compliance Property 3445 YANCEY PL CARMEL, IN 46074 AM010 (AS DESIGNED) ASHMOOR 10 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $2,516 $370 $449 $3,335 $1,208 50 $4,542 Requirements C4405.3 Performance-based compliance passes by 3.9% 402.4.1.2 Air Leakage Testing 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U -Factor 40322 Duct. Testing C4 Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation CTSI Energy Solutions As Designed 52,426 5330 5449 $3,204 S1,208 50 $4,412 Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa. Design exceeds requirements for IECC 2009 Performance compliance by 3.9%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 217119 at 8:58 AM Ekotrope RATER - Version 3.1.0.2105 IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool. 3445 YANCEY PL CARMEL, IN 46074 LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls R-11 Framed Floor NIA Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U -Value: 0.32, SHGC: 0.31 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 453.0 CFM @ 25Pa Total Duct Leakage 605.0 CFM @ 25Pa Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 217119 at 8:58 AM Ekotrope RATER - Version 3.1.0.2105 No version of this software has been reviewed or approved by ICC or its affiliates. The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC'). This software is a RESIN ETAccredited HERS Rating Tool. Energy Code Inspection Checklist Property 3445 YANCEY PL CARMEL, IN 46074 AM010 (AS DESIGNED) ASHMOOR 10 General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 7,562 73,366 13,624 Inspection Status Results are projected C-M, Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identity any changes and ensure that the home continues to meet the applicable energy code. Slab ] Name: BSMT (3,114 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall ] Name: CONDIAMB (Exterior Perimeter [ft]: 206, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 ]l Name: CONDIGAR (Exterior Perimeter [ft]: 82, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Alcove Grade Wall El Name: COND/AMB (2,162 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIAMB 2X6 (600 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I ]l Name: CONDfGAR (820 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property Organization 3445 YANCEY PL TSI Energy Solutions CARMEL, IN 46074 Matthew Timmons AM010 (AS DESIGNED) Builder ASHMOOR 10 LENNAR HOMES Name: CONDIATTIC (748 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist El Name: CONDIAMB (272 s.f.) R: 13.575 Name: CONDIGAR (82 s.f.) R: 10.876 El Name: CONDIATTIC (72 s.f.) R: 13.575 Roof Name: MAIN (2,922 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I El Name: SLOPED (240 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Opaque Door El Name: FRONT (24 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected El Name: FRONT (196 s.f.), U:0.320, SHGC: 0.28, Orientation: SOUTH El Name: BACK (66 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH C", Energy Solutions 2 Energy Code Inspection Checklist C-M Energy Solutions Property Organization 3445 YANCEY PL TSI Energy Solutions CARMEL, IN 46074 Matthew Timmons Inspection Status Results are projected AM010 (AS DESIGNED) Builder ASHMOOR 10 LENNAR HOMES E] Name: BACK 2X6 (154 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH E] Name: BACK GD (18 s.f.), U:0.290, SHGC: 0.33, Orientation: NORTH E] Name: BACK BSMT (16 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH El Name: RIGHT SIDE (30 s.f.), U:0.320, SHGC: 0.31, Orientation: EAST El Name: RIGHT SIDE 2X6 (15 s.f.), U:0.320, SHGC: 0.31, Orientation: EAST El Name: LEFT SIDE (102 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST 11 Name: LEFT SIDE 2X6 (18 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST El Name: LEFT GD (18 s.f.), U:0.290, SHGC: 0.33, Orientation: WEST Name: LEFT BSMT (16 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST Skylight None Present Mechanical Ventilation None Present Mechanical Equipment El Fuel -fired air distribution [1) • Natural Gas • 100% Heating Load @ 95.5 AFUE E] Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control 3 Test Status: Blower -door tested House is air -sealed as to achieve 6,114 CFM50 (5.00 ACH50) or less at final blower -door test. Energy Code Inspection Checklist Property 3445 YANCEY PL CARMEL, IN 46074 AM010 (AS DESIGNED) ASHMOOR 10 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Infiltration Requirements for IECC in Climate Zone 5 Inspection Status Results are projected 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 453.0 CFM @ 25 Pa Total Duct Leakage is specified in Ekotrope at 605.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary C-M Energy Solutions Property Organization 3445 YANCEY PL TSI Energy Solutions CARMEL, IN 46074 Matthew Timmons Inspection Status AM010 [AS DESIGNED] Builder Results are projected ASHMOOP 10 LENNAR HOMES General Building Information MM Number Of Bedrooms 5 Number Of Floors 2 Conditioned Floor Area [sq. ft.] 7;562 Unconditioned, attached garage? Yes Conditioned Volume [cu. ft.] 73;366 Total Units in Building 1 Residence Type Single family detached Model PARKSIDE (B) Community ASHMOOR 10 Climate Zone 5A Basement Wall Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, Oft 1 8 2D6 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, Oft 1 8 82 Exposed Exterior Conditioned Space Basement Wall Library List Name Feet From Wall Tap To Insulation Feet From Wall Top Tb Insulation Is Fully Insulated R -value Tap Bottom R-11 Draped, Oft 0 4 No 11.00 Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area BSMT Uninsulated 288 Below Grade ❑ 0 3,114.0 sq. fL Exposed Exterior Conditioned Space Slab Library List Name Wall C Uninsulated Wood Frame / Other No ❑ 0 D 0.00 1 Building Summary Property Organization 3445 YANCEY PL TSI Energy Solutions CARMEL, IN 46074 Matthew Timmons AM010 [AS DESIGNED] Builder ASHMOOP 10 LENNAR HOMES ramed Floor None Present Framed Floor Library List Rim Joist Name CONDIAMB CONDIATTIC C O N DIGAR Rim Joist Library List Name G1 R-13,0813 G1 R-13, R-3.0 Library 7yp( G1 R-13, R-3.0 Inspection Status Results are projected urface Area 272.0 sq. ft. TSI Energy Solutions Locatior Exposed Exterior G1 R-13, R-3.0 72.0 sq. ft. Attic G1 R-13, OSB 2 -Value 10.876 13.575 82.0 sq. ft. Unconditioned, attached garage 2 Name Library Type Surface Calor Surface Area Location CONDIAMB G1 R-13 BATT, R-3.0 Medium 2.162.0 sq. ft. Exposed Exterior CONDIAMB 2X6 G1 R-19, R-3.0 2X6 Medium 600.0 sq. ft. Exposed Exterior CONDIATTIC G1 R-13 BATT, R-3.0 Medium 748.0 sq. ft. Attic CONDIGAR G1 R-13 Gar Walls Medium 8200.sq. ft. Unconditioned, attached garage 2 Building Summary Property 3445 YANCEY PL CARMEL, IN 46074 AM010 [AS DESIGNED] ASHMOOP10 brary List AA Name G1 R-13 BATT, R-3.0 G1 R-13 Gar Walls G1 R-19, R-3.0 2X6 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 20217 Inspection Status Results are projected C-M, Energy Solutions Glazing Name Library type Wall Assignment Basement Wall Overhang Depth Assignment Overhang Ft To Top Overhang Ft To Bottom Orientation Surface Area BACK U-.32, SHGC-.31 CONDIAMB 0 0 0 North 66.0 sq. ft BACK 2X6 U-.32, SHGG.31 CONDIAMB 2X6 0 0 0 North 154.0 sq. ft. BACK BSMT U-.32, SHGG.31 CONDIAMB 0 0 0 North 16.0 sq. fL BACK GD U-29, SHGG.33 CONDIAMB 2716 0 0 0 North 18.0 sq. ft FRONT U-.32, SHGG28 CONDIAMB 0 0 0 South 1960.sq. R. LEFT BSMT U-.32, SHGG.31 CONDIAMB 0 0 0 West 16.0 sq. 1 LEFT GD U-29, SHGG.33 CONDIAMB 0 0 0 West 18.0 sq. R LEFT SIDE U-.32, SHGG.31 CONDIAMB 0 0 ❑ West 102.0 sq. ft. LEFT SIDE 2X6 U-.32, SHGG.31 CONDIAMB 2X6 0 0 ❑ West 18.0 sq. fL RIGHT SIDE U-.32, SHGG.31 CONDIAMB 0 0 ❑ East 30.0 sq. fL RIGHT SIDE 2X6 U-.32, SHGG.31 CONDIAMB 2X6 0 0 ❑ East 15.0 sq. fL Glazing Library List Name U-29, SHGC-.33 U-.32, SHGC-28 U-.32, SHGC-.31 Singe U #actor 0.33 0.290 028 0.320 0.31 0.320 9 Building Summary Property 3445 YANCEY PL CARMEL, IN 46074 AM010 [AS DESIGNED] ASHMOOP10 kylight J Skylight Library List Opaque Door Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected C-M, Energy Solutions Name Library Type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location Assignment Ab sorpta n ce FRONT Steel Door CONDIAMB 0.9 0.75 Medium 24.0 sq. ft Exposed Exterior GARAGE Steel Door CONDIGAR 0.9 0.75 Medium 18.0 sq. ft Exposed Exterior Opaque Door Library List Name Steel Door Roof Insulation U -factor 0.182 Name Library Type Attic Exterior Area Cray or Concrete Roof Surface Color Surface Area Location P.f.] Tiles MAIN R-38 Blown, GR1 2,922 No Medium 2,922.0 sq. ft Attic SLOPED R-38 Vaulted, GR1 240 No Medium 240.0 sq. 1 Vaulted Roof Roof Insulation Library List Name Has R-38 Blown, GR1 R-38 Vaulted, GR1 No 38.268 No 32263 4 Building Summary Property 3445 YANCEY PL CARMEL, IN 46074 AM010 [AS DESIGNED] ASHMOOP10 I Whole House Infiltration Infiltration I5 ACH at 50 Pa 1 Mechanical Ventilation Organization TSI Energy Solutions Matthew Timmons Inspection Status Builder Results are projected LENNAR HOMES Blower -door tested 4 None Present C-M, Energy Solutions Lighting % Interior Fluorescent % Interior LED Lighting I Exterior Fluorescent % Exterior LED Lighting I Garage Fluorescent % Garage LED Lighting Lighting Lighting Lighting C 100 Onsite Generation W IL None Present Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present 0 100 0 100 A Building Summary Property Organization 3445 YANCEY PL TSI Energy Solutions CARMEL, IN 46074 Matthew Timmons AM010 [AS DESIGNED] Builder ASHMOOP 10 LENNAR HOMES Inspection Status Results are projected conditioning Equipment Name Library Type Heating Percent Load Air conditioner (2) CA13NA042 0% C-M, Energy Solutions g Percent LOW Hot water icc% I Fuel -fired air 915SA42100S21 100% G°o distribution (1) IWater Heating (3) RE350" 0% X11% 1 Equipment Type: 915SA4210OS21 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 95.5 AFUE Heating Capacity [kBtulh] 97 Use default EAE No EAE [kWh] 1;205 Equipment Type: CA13NA042 Fuel Type Distribution Type Motor Type Cooling Efficiency Cooling Capacity [kBtulh] Equipment Type: RE350* Fuel Type Distribution Type Hot Water Efficiency Tank Capacity (gal.) Hot Water Capacity [kBtulh] Recovery Efficiency Electric Forced Air PSG (Single Speed) 13 SEER 40 Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 0% 0% 100% Building Summary Property Organization 3445 YANCEY PL TSI Energy Solutions CARMEL, IN 46074 Matthew Timmons Sq. Feet Served Inspection Status AM010 [AS DESIGNED] Builder Results are projected ASHMOOP 10 LENNAR HOMES istribution System Distribution Type Forced Air Heating Equipment Fuel -f red air distribution [1) Cooling Equipment Air conditioner (2) Sq. Feet Served 7562 # Return Grilles 8 Supply Duct R Value 30 Return Duct R Value 30 Supply Duct Area [sq. ft.] 1531.3 Return Duct Area [sq. ft_] 1417.9 Duct Leakage to Outdoors (CFM25) 453 Total Leakage 605 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 60 Percent Return Area 60 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area 40 Percent Return Area 40 Duct 3 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Ceiling Fan ' Has Ceiling Fan No Cfm Per Watt 101 Water Distribution Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 107 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 34 Drain Water Heat Recovery? No C-M, Energy Solutions Building Summary Property 3445 YANCEY PL CARMEL, IN 46074 AM010 [AS DESIGNED] ASHMOOP10 Organization TSI Energy Solutions Matthew Timmons Inspection Status Builder Results are projected LENNAR HOMES lothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I mef Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption "M 704 kWh/Year 0.0nWh $23.00 $0.581Therm 2.874 0.331 Yes Standard 270 kWh Electric No No 709 kWh/Year C-M, Energy Solutions ,�