Loading...
HomeMy WebLinkAboutA000.3\A1;1'-1" 1012 1012 \A1;4'-6" A.F.F. \A1;3'-2" TYP. SHINGLES PERSUB. SPECS. SIDING PER SPECS 8" TRIM4" TRIM (TYP.) 4" TRIM (TYP.) SHINGLES PERSUB. SPECS. SIDING PER SPECS SIDING PER SPECS8" TRIM4" TRIM (TYP.) 4" TRIM SURROUND ON DOOR10" SQ. COLUMN(SEE PORCH DETAIL)8" TRIM4" TRIM BOARD \A1;4'-0" SHAKE SIDING PER SPECS 8" TRIM 16x36 LOUV. VENT SHINGLES PER SPECS.SHINGLES PER SPECS. SCALE:FRONT ELEVATION1/4" = 1'-0"- ROWLOCK SILL, PER SPECBRICK VENEER, PER SPEC \A1;2'-3{\H0.75x;\S3#8;}" ROOF W/\POPT. LOFT \A1;8'-1{\H0.75x;\S1#8;}"\A1;7'-2{\H0.75x;\S7#8;}" \A1;9'-1{\H0.75x;\S1#8;}"\A1;OPT. 10'-1{\H0.7x;\S1#8;}" \A1;8'-2{\H0.75x;\S7#8;}"\A1;9'-2{\H0.7x;\S7#8;}" @ OPT. 10' PL. WINDOW HEIGHT 1st FLR LINE PLATE HEIGHT SECOND FLOOR PLATE (OPT. LOFT)WINDOW HDR. HGT. TOP OF FOUNDATION SCALE:REAR ELEVATION1/8" = 1'-0"- OPT. BRICK HEIGHT SCALE:LEFT ELEVATION1/8" = 1'-0"- \A1;8'-4{\H0.75x;\S3#8;}"\A1;HDR. HGT. @ 4010 OPT. DOOR\PPER PLAN 125 125 OPT. BRICK HEIGHT 127ROOF W/OPT. LOFT 127 SCALE:RIGHT ELEVATION1/8" = 1'-0"- WINDOW HEIGHT 1st FLR LINE CEILING HEIGHT 10:1210:12\A1;1'-1" SIDING PER SPECS \A1;1'-1"\A1;2'-0"512 6" CORNER BD.ON FRONT ELEV. &4" ON SIDES& REAR ELEV. ROOF SHINGLES, \PPER SPEC 6" FASCIA BOARD, \PPER SPEC OPT. BRICK HEIGHTTOP OF FOUNDATION OPT. WINDOWS\PPER PLAN 127ROOF W/\POPT. LOFT 127SECOND FLOOR PLATE (OPT. LOFT) \A1;8'-1{\H0.75x;\S1#8;}"\A1;7'-2{\H0.75x;\S7#8;}" WINDOW HDR. HGT. \A1;9'-1{\H0.75x;\S1#8;}"\A1;OPT. 10'-1{\H0.7x;\S1#8;}" \A1;8'-2{\H0.75x;\S7#8;}"\A1;9'-2{\H0.7x;\S7#8;}" @ OPT. 10' PL. SCALE:ROOF PLAN1/8" = 1'-0"- ROOF AREA"A"2973 SQ. FT. 5:12 5:12 OPT. POT VENTS \A1;30'-0" \A1;10'-0" 9:12 9:129:12 \A1;1'-0"\PTYP.9:129:12 OPT. GUTTER AND DOWNSPOUTS OPT 7:12 OPT 7:12 ELEVATION HR2C ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 2973 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 3.96 4.96 5.08 49.73 12 0 AT EAVE 5.95 4.96 5.14 50.27 0 74.00 TOTAL (MIN)9.91 9.91 10.22 100.00 3 HIGH - RIDGE VENT 3.96 4.96 5.00 49.32 0 0 40.00 AT EAVE 5.95 4.96 5.14 50.68 0 74.00 TOTAL (MIN)9.91 9.91 10.14 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE SCALE 1/4" = 1'-0"PORCH ELEVATIONS LEFT PORCH FRONT PORCH RIGHT PORCH2" CORNER BOARD (TYP)SIDING PER COMM. SPECS (TYP)1900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone Office........................... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2017 RICK STARKEY06/07/2013 GARAGE LEFT Croix 1993.301 -- 08/01/2017 PLOTTED: October 6, 2017 / Mark Muurisepp / 1993-CROIX-CZ-BAS2-EL-HR2C.DWG A3 HR2C-2FS.1Heartland 2C - Slab2 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule6:12 in shadow wood 12" overhangs 4 sides 03/28/19 Adam Schriner