Loading...
HomeMy WebLinkAboutSPPSTOEPPELWERTH JOB ID ALWAYS ON CONTROL# 7965 East 106th Street, Fishers, IN 46038-2505 phone: 317.849.5935 fax: 317.849.5942 I ESTABLISHED DRAINAGE EASEMENT I WITH EROSION CONTROL IN PLACE. DO NOT DISTURB. T.C.= 903.6 \AS BUILT LOT 80 / PROP. HSE. w MH SNT843 / SOD LINE 2�'_25' D.&U. E, S.S.E. T.C.= 905.72 AS BUILT APPROX. 12' FROM TAP TO HOUSE 96-- — }— CONTRACTOR S.S.D� - w I6S HEREO IN SANCT2B.79 86298 RYAN LOT 79 THE SANCTUARY AT 116TH STREET SECTION 213 INST #2018052833 01 P.C. #5 SLIDE #899 T.C.= 904.37 AS BUILT 016.00' co Yo 0) 3.00' MORNING 21.00' ROOM MODEL= ROME N F.F.ELEV.= 909.27 2'X4.67 T.O.W.= 908.07 F.P. BSMT.= 900.41 0 (VERSION 06) (RH) N 129 in M 12.00' GAR. \ 19. O acmJn 3 0N PORCH o� 20.96'n 11.67' CONC. oDRIVE 0 20. If 5.5'SW _ 139.6 W W_ 05.06 / T.C.= 904.42 AS BUILT / - WEST T.C.=904.42 ROAD AS BUILT 25.5'SW LEGEND: 430 ± Sq. XX.X PROPOSED GRADE PER PLAN XX.XAB AS BUILT GRADE CONIC. DRIVEWAY: S.S.D. _ _ SUB—SURFACE DRAIN Ft. SANITARY SEWER 24± Sq. STORM SEWER PUBLIC WALK: W WATER MAIN Ft. W 3/4" WATER CONNECTION 272± Sq. 000<_ SWALE • SANITARY MANHOLE �J ■ N D.&U.E. B.S.L. S.S.E. M.L. A. G. M.F.P. G. M.F.F. T.O.W. STORM MANHOLE CURB INLET ALL UNDERGROUND SEWERS AND UTILITIES SHOWN ARE PLOTTED BY SCALE FROM "RECORD DRAWINGS" FURNISHED BY ENGINEER. BENCHMARK TOP OF CASTING = 904.42 SOD: 430 ± Sq. Yd. SEEDING: 5,687 ± Sq. Ft. CONIC. DRIVEWAY: 754 ± Sq. Ft. PRIVATE WALK: 24± Sq. Ft. PUBLIC WALK: 790 ± Sq. Ft. APRON: 272± Sq. Ft. 11944 WEST ROAD ZIONSVILLE, IN 46077 1 of = 30' LOT AREA: 13,135 Sq. Ft. M.LA.G.=907.20 M.F.P.G.=907.20 M.F.F.=908.20 LOT 78 VACANT LOT SOD LINE FIRE HYDRANT T.C.= 905.92 AS BUILT END SECTION MH SNT842 � W 0' MINIMUM REAR YARD EMERGENCY FLOOD ROUTE NOTE: SIDE/REAR SETBACKS & MINIMUM DRAINAGE & UTILITY EASEMENT BUILDING SEPARATION SHALL BE INCREASED BUILDING SETBACK LINE 05.70 SANITARY SEWER EASEMENT w � MINIMUM LOWEST ADJACENT GRADE MINIMUM FLOOD PROTECTION GRADE Lo MINIMUM FINISHED FLOOR EXCEEDING THIRTY—FIVE (35) FEET IN HEIGHT FIRE HYDRANT ZONINGS-1/RESIDENCE — ROSO III WITH WAIVERS 25' MINIMUM FRONT YARD (GARAGE) 0' MINIMUM SIDE YARD END SECTION 6' MINIMUM BETWEEN STRUCTURE 0' MINIMUM REAR YARD EMERGENCY FLOOD ROUTE NOTE: SIDE/REAR SETBACKS & MINIMUM DRAINAGE & UTILITY EASEMENT BUILDING SEPARATION SHALL BE INCREASED BUILDING SETBACK LINE BY ONE (1) FOOT FOR EACH ADDITIONAL (1) FOOT SANITARY SEWER EASEMENT A STRUCTURE IS RAISED ABOVE THE TWENTY—FIVE MINIMUM LOWEST ADJACENT GRADE MINIMUM FLOOD PROTECTION GRADE (25) FOOT HEIGHT STANDARD— WITH NO STRUCTURE MINIMUM FINISHED FLOOR EXCEEDING THIRTY—FIVE (35) FEET IN HEIGHT TOP OF WALL SW Sj0EPp ............... F Q : No. �-A =_ 80040474: STATE OF zNDIANP , NOTE: THIS DRAWING IS NOT INTENDED TO BE REPRESENTED AS A RETRACEMENT OR ORIGINAL BOUNDARY SURVEY, A ROUTE SURVEY OR A SURVEYOR LOCATION REPORT. 02/12/19 JHS r t Know whaPs below. Call before you dig.