HomeMy WebLinkAboutM001.0IECC 2009 Performance Compliance Property 14249 JAMES DEAN DR CARMEL, IN 46033 GLO56 (AS DESIGNED) THE GROVE AT LEGACY 56 Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,139 $173 $342 $1,655 $800 $0 $2,455 Requirements C4405.3 Performance-based compliance passes by 1.2% 402.4.12 Air Leakage Testing C4402.5 Area -weighted average fenestration SHGG 402.5 Area -weighted average fenestration U -Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation C-M, Energy Solutions As Designed $1,125 $167 $342 $1,635 $800 $0 $2,435 Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa. design exceeds requirements for IECC 2009 Performance compliance by 1.2%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Michael Hill Organization: TSI Energy Solutions Signature: Date: 2128/19 at 10:28 AM Ekotrope RATER - Version 3.1.0.2119 IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool. 14249 JAMES DEAN DR CARMEL, IN 46033 PYATT BUILDERS, LLC Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls NIA Framed Floor R-38 Slab R-10.0 Perimeter, R-10.0 Under Infiltration 5 ACH50 Window U -Value: 0.32, SHGC: 0.31 Building Features Duct Supply R-30.0, Return R-20.0 Duct Leakage to Outside 144.0 CFM @ 25Pa Total Duct Leakage 192.0 CFM @ 25Pa Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name Michael Hill Organization: TSI Energy Solutions Signature: Date: 2f28f 19 at 10:28 AM Ekotrope RATER - Version 3.1.0.2119 No version of this software has been reviewed or approved by ICC or its affiliates. The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC'). This software is a RESIN ETAccredited HERS Rating Tool. Energy Code Inspection Checklist Property 14249 JAMES DEAN DR CARMEL, IN 46033 GL056 (AS DESIGNED) THE GROVE AT LEGACY 56 General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC 2,449 23,174 6,208 Inspection Status Results are projected C-M, Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identity any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB (1,133s.f.) R-10 perimeter insulation, R-10 under slab insulation. Framed Floor El Name: OVER GAR (271 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall None Present Above Grade Wall El Name: CONDIAMB (2,672 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I El Name: CONDIGAR (350 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I El Name: CONDIATTIC (213 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Joist Energy Code Inspection Checklist Property 14249 JAMES DEAN DR CARMEL, IN 46033 GLO56 (AS DESIGNED) THE GROVE AT LEGACY 56 Roof Name: CONDIAMB (94 s.f.) R: 11.691 Name: CONDIATTIC (71 s.f.) R: 11.691 Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Name: MAIN (1,404 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected 11 Name: FRONT (103 s.f.), U:0.320, SHGC: 0.31, Orientation: EAST 11 Name: BACK (84 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST 11 Name: SLIDER (40 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST E] Name: LEFT SIDE (75 s.f.), U: 0.320, SHGC: 0.31, Orientation: SOUTH E] Name: RIGHT SIDE (148 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH Skylight None Present Mechanical Ventilation None Present C-M, Energy Solutions 2 Energy Code Inspection Checklist Property 14249 JAMES DEAN DR CARMEL, IN 46033 GLO56 (AS DESIGNED) Organization TSI Energy Solutions 317-846-4655 Michael Hill Inspection Status Results are projected THE GROVE AT LEGACY 56 Builder PYATT BUILDERS, LLC Mechanical Equipment 0 Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 92.1 AFUE M Air conditioner • Electric • 100% Cooling Load @ 13 SEER E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 1,931 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 144.0 CFM @ 25 Pa Total Duct Leakage is specified in Ekotrope at 192.0 CFM @ 25Pa C", Energy Solutions 3 Energy Code Inspection Checklist Property 14249 JAMES DEAN DR CARMEL, IN 46033 GLO56 (AS DESIGNED) THE GROVE AT LEGACY 56 Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property 14249 JAMES DEAN DR CARMEL, IN 46033 GLO56 (AS DESIGNED) THE GROVE AT LEGACY 56 General Building Information Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Inspection Status Results are projected Number Of Bedrooms 3 Number Of Floors 2 Conditioned Floor Area [sq_ ft.] 2;449 Unconditioned, attached garage? Yes Conditioned Volume [cu. ft.] 23;174 Total Units in Building 1 Residence Type Single family detached Model BERKLEY Community THE GROVE AT LEGACY 56 Climate Zone 5A Basement Wall Basement Wall Library List None Present C-M, Energy Solutions Slab MA&MM Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area SLAB R-10, 1'down, 2' in 175 On Grade 1.23 0 1,133.0 sq. R. Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Type Slab Completer Underslab Insulation Perimeter Insulation Perimeter Insulation R R -value Insulated. Width [ft] Depth 1111 Value R-10, 1'down, 2' in Wood Frame / Other No 2 1 1D 14.00 Framed Floor Name Library Type IOVER Carpet R Floor Grade Surface Area Location GAR R-38, GR1 1.23 Above Grade 271.0 sq. R Unconditioned, attached garage 1 Building Summary Property Organization 14249 JAMES DEAN DR TSI Energy Solutions CARMEL, IN 46033 317-846-4655 G1 R-15 BATT, OSB Michael Hill GLO56 (AS DESIGNED) Exposed Exterior THE GROVE AT LEGACY 56 Builder Medium PYATT BUILDERS, LLC Framed Floor Library List CONDIGAR Name R -value R-38, GR1 Unconditioned, attached garage 33.825 Rim Joist _ Name CONDIAMB CONDIATTIC Rim Joist Library List Name G1 R-15, OSB C-M, Energy Solutions Inspection Status Results are projected Library Type Surface Area Locatior G1 R-15, OSB 94.0 sq. ft. Exposed Exterior G1 R-15, OSB 71.0 sq. ft. Attic ■ R -value Name Library Type Surface Color Surface Area Location CONDIAMB G1 R-15 BATT, OSB Medium 2,672.0 sq. ft. Exposed Exterior CONDIATTIC G1 R-15 BATT, OSB Medium 213.0 sq. fl. Attic CONDIGAR G1 R-15 Gar Walls Medium 350.0 sq. ft. Unconditioned, attached garage Wall Library List Name R -value G1 R-15 BATT, OSB 13.423 G1 R-15 Gar Walls 11.972 2 Building Summary Property Organization 14249 JAMES DEAN DR TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Michael Hill Inspection Status GLO56 (AS DESIGNED) Results are projected THE GROVE AT LEGACY 56 Builder PYATT BUILDERS, LLC lazing Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft To Assignment Top Overhang Ft To Bottom C-MEnergy Solutions Orientation Surface Area BACK 11-.32, SHGG.31 CONDIAMB 0 0 0 West 84.0 sq. ft FRONT 1-1-.32, SHGC-.31 CONDIAMB 0 0 0 East 103.0 sq. it. LEFT SIDE 11-.32, SHGG.31 CONDIAMB ❑ 0 ❑ South 75.0 s9. fL RIGHT SIDE 11-.32, SHGC-.31 CONDIAMB ❑ 0 ❑ North 148.0 sq. ft. SLIDER 11-.32, SHGG.31 CONDIAMB ❑ ❑ ❑ West 40.0 sq. ft Glazing Library List Name Shgc U factor U-32, SHGC-.31 0.31 0.320 lig None Present Skylight Library List None Present Opaque Door Name Library Type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location Assign ment Ab sorpta n ce FRONT Steel Door CONDIAMB 0.9 0.75 Medium 20.0 sq. fL Exposed Exterior GARAGE Steel Door CONDIGAR 09 0.75 Medium 18.0 sq. fL Exposed Exterior Building Summary Property 14249 JAMES DEAN DR CARMEL, IN 46033 GL056 (AS DESIGNED) THE GROVE AT LEGACY 56 paque Door Library List Name Steel Door Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC 0.182 Inspection Status Results are projected C-M, Energy Solutions Roof Insulation Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location �.f.] Tiles DRAIN R-38 Blown, GR1 1,404 No Medium 1,404.0 sq. ft Attic Roof Insulation Library List Name Has Radiant Barrier R -value R-38 Blown, GR1 Na 38.268 Whale House Infiltration InfiRration 5 ACH at 50 Pa Mechanical Ventilation Blower -door tested 4 None Present Lighting I % Interior Fluorescent °% Interior LED Lighting % Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting Lighting Lighting Lighting I0 ❑ 0 a ❑ ❑ 4 Building Summary Property 14249 JAMES DEAN DR CARMEL, IN 46033 GLO56 (AS DESIGNED) THE GROVE AT LEGACY 56 Onsite Generation Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Onsite Generation Library List None Present Solar Generation None Present Inspection Status Results are projected Solar Generation Library List None Present Conditioning Equipment Name Library Type Heating Percent Load Air conditioner CA13NA030 0% I Fuel4red air 9125A4206OS17 100% distribution IWater Heating RE350' 0% quipment Type: 912SA4206OS17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSC (Single Speed) Heating Efficiency 92.1 AFUE Heating Capacity [kBtulh] 57 Use default EAE Yes EAE [kWh] 736.1 Coaling Percent Load 100% 0% ❑% C-M, Energy Solutions L A Hot Water Percent Load 0% 0% 100% :j Building Summary Property 14249 JAMES DEAN DR CARMEL, IN 46033 GLO56 (AS DESIGNED) THE GROVE AT LEGACY 56 _ Equipment Type: CA13NA030 Fuel Type Distribution Type Motor Type Cooling Efficiency Cooling Capacity [kBtulh] Equipment Type: RE350* Fuel Type Distribution Type Hot Water Efficiency Tank Capacity {gal.} Hot Water Capacity [kBtulh] Recovery Efficiency Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Electric Forced Air PSC [Single Speed] 13 SEER 27.4 Inspection Status Results are projected M ��� Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 C-M, Energy Solutions Building Summary Property Organization 14249 JAMES DEAN DR TSI Energy Solutions CARMEL, IN 46033 317-846-4656 Sq. Feet Served Michael Hill Inspection Status GLO56 (AS DESIGNED) Results are projected THE GROVE AT LEGACY 56 Builder Return Duct R Value PYATT BUILDERS, LLC Vistribution System Distribution Type Forced Air Heating Equipment Fuel -f red air distribution Cooling Equipment Air conditioner Sq. Feet Served 2449 4 Return Grilles 2 Supply Duct R Value 30 Return Duct R Value 20 Supply Duct Area [sq. ft.] 661.23 Return Duct Area [sq. ft_] 244.9 Duct Leakage to Outdoors (CFM25) 144 Total Leakage 192 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Attic (well vented; under insulation) Percent Supply Area 40 Percent Return Area 40 Duct 2 Duct Location Conditioned Space Percent Supply Area 66 Percent Return Area 60 Duct 3 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Duct 4 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Duct 6 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Ceiling Fan Has Ceiling Fan No Cfm Per Watt 144 ater Distributionter Fixture Type Standard e Default Hot Water Pipe Length No t Water Pipe Length [ft] I 75 Least R3 Pipe Insulation? No t Water Recirculation System? No circulation System Pipe Loop Length jft] 2d in Water Heat Recovery? No C-M, Energy Solutions Building Summary Property 14249 JAMES DEAN DR CARMEL, IN 46033 GLO56 (AS DESIGNED) THE GROVE AT LEGACY 56 Clothes Dryer Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I mef Appliances and Controls Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Electric 2.617 Timer Controls 704 kWhlYear 0.081kWh $23.00 $0.581Therm 2.874 0.331 Programmable thermostat? Yes Dishwasher Size Standard Dishwasher Efficiency 270 kWh Range/Oven Fuel Electric Convection Oven? No Induction Range? No Refrigerator Consumption 709 kWhlYear Notes Inspection Status Results are projected C-M, Energy Solutions L1