HomeMy WebLinkAboutM001.0IECC 2009 Performance Compliance
Property
14249 JAMES DEAN DR
CARMEL, IN 46033
GLO56 (AS DESIGNED)
THE GROVE AT LEGACY 56
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$1,139
$173
$342
$1,655
$800
$0
$2,455
Requirements
C4405.3
Performance-based compliance passes by 1.2%
402.4.12
Air Leakage Testing
C4402.5
Area -weighted average fenestration SHGG
402.5
Area -weighted average fenestration U -Factor
40322
Duct Testing
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052
Duct Insulation
C-M,
Energy Solutions
As Designed
$1,125
$167
$342
$1,635
$800
$0
$2,435
Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa.
design exceeds requirements for IECC 2009 Performance compliance by 1.2%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Michael Hill
Organization: TSI Energy Solutions
Signature:
Date:
2128/19 at 10:28 AM
Ekotrope RATER - Version 3.1.0.2119
IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool.
14249 JAMES DEAN DR
CARMEL, IN 46033
PYATT BUILDERS, LLC
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls NIA
Framed Floor R-38
Slab R-10.0 Perimeter, R-10.0
Under
Infiltration 5 ACH50
Window U -Value: 0.32, SHGC: 0.31
Building Features
Duct Supply R-30.0, Return R-20.0
Duct Leakage to Outside 144.0 CFM @ 25Pa
Total Duct Leakage 192.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name
Michael Hill
Organization: TSI Energy Solutions
Signature:
Date: 2f28f 19 at 10:28 AM
Ekotrope RATER - Version 3.1.0.2119
No version of this software has been reviewed or approved by ICC or its affiliates.
The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC').
This software is a RESIN ETAccredited HERS Rating Tool.
Energy Code Inspection Checklist
Property
14249 JAMES DEAN DR
CARMEL, IN 46033
GL056 (AS DESIGNED)
THE GROVE AT LEGACY 56
General Building Information
Conditioned Area (sq ft)
Conditioned Volume (cubic ft)
Insulated Shell Area (sq ft)
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
2,449
23,174
6,208
Inspection Status
Results are projected
C-M,
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identity any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: SLAB (1,133s.f.)
R-10 perimeter insulation, R-10 under slab insulation.
Framed Floor
El Name: OVER GAR (271 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Foundation Wall
None Present
Above Grade Wall
El Name: CONDIAMB (2,672 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
El Name: CONDIGAR (350 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
El Name: CONDIATTIC (213 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Rim Joist
Energy Code Inspection Checklist
Property
14249 JAMES DEAN DR
CARMEL, IN 46033
GLO56 (AS DESIGNED)
THE GROVE AT LEGACY 56
Roof
Name: CONDIAMB (94 s.f.)
R: 11.691
Name: CONDIATTIC (71 s.f.)
R: 11.691
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
Name: MAIN (1,404 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
11 Name: FRONT (103 s.f.), U:0.320, SHGC: 0.31, Orientation: EAST
11 Name: BACK (84 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST
11 Name: SLIDER (40 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST
E] Name: LEFT SIDE (75 s.f.), U: 0.320, SHGC: 0.31, Orientation: SOUTH
E] Name: RIGHT SIDE (148 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH
Skylight
None Present
Mechanical Ventilation
None Present
C-M,
Energy Solutions
2
Energy Code Inspection Checklist
Property
14249 JAMES DEAN DR
CARMEL, IN 46033
GLO56 (AS DESIGNED)
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Inspection Status
Results are projected
THE GROVE AT LEGACY 56 Builder
PYATT BUILDERS, LLC
Mechanical Equipment
0 Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 92.1 AFUE
M Air conditioner • Electric • 100% Cooling Load @ 13 SEER
E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 1,931 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 144.0 CFM @ 25 Pa
Total Duct Leakage is specified in Ekotrope at 192.0 CFM @ 25Pa
C",
Energy Solutions
3
Energy Code Inspection Checklist
Property
14249 JAMES DEAN DR
CARMEL, IN 46033
GLO56 (AS DESIGNED)
THE GROVE AT LEGACY 56
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
14249 JAMES DEAN DR
CARMEL, IN 46033
GLO56 (AS DESIGNED)
THE GROVE AT LEGACY 56
General Building Information
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
Inspection Status
Results are projected
Number Of Bedrooms
3
Number Of Floors
2
Conditioned Floor Area [sq_ ft.]
2;449
Unconditioned, attached garage?
Yes
Conditioned Volume [cu. ft.]
23;174
Total Units in Building
1
Residence Type
Single family detached
Model
BERKLEY
Community
THE GROVE AT LEGACY 56
Climate Zone
5A
Basement Wall
Basement Wall Library List
None Present
C-M,
Energy Solutions
Slab MA&MM
Name Library Type Perimeter
Floor Grade
Carpet R
Exposed Surface Area Location
Enclosing
Masonry Area
SLAB R-10, 1'down, 2' in
175 On Grade
1.23
0 1,133.0 sq. R. Exposed Exterior
Conditioned
Space
Slab Library List
Name Wall Construction Type
Slab Completer Underslab Insulation
Perimeter Insulation Perimeter Insulation R
R -value
Insulated.
Width [ft]
Depth 1111 Value
R-10, 1'down, 2' in Wood Frame / Other
No
2
1 1D
14.00
Framed Floor
Name Library Type
IOVER
Carpet R
Floor Grade Surface Area
Location
GAR R-38, GR1
1.23
Above Grade 271.0 sq. R Unconditioned, attached
garage
1
Building Summary
Property
Organization
14249 JAMES DEAN DR
TSI Energy Solutions
CARMEL, IN 46033
317-846-4655
G1 R-15 BATT, OSB
Michael Hill
GLO56 (AS DESIGNED)
Exposed Exterior
THE GROVE AT LEGACY 56
Builder
Medium
PYATT BUILDERS, LLC
Framed Floor Library List
CONDIGAR
Name
R -value
R-38, GR1
Unconditioned, attached garage
33.825
Rim Joist _
Name
CONDIAMB
CONDIATTIC
Rim Joist Library List
Name
G1 R-15, OSB
C-M,
Energy Solutions
Inspection Status
Results are projected
Library Type Surface Area Locatior
G1 R-15, OSB 94.0 sq. ft. Exposed Exterior
G1 R-15, OSB 71.0 sq. ft. Attic
■
R -value
Name
Library Type
Surface Color
Surface Area
Location
CONDIAMB
G1 R-15 BATT, OSB
Medium
2,672.0 sq. ft.
Exposed Exterior
CONDIATTIC
G1 R-15 BATT, OSB
Medium
213.0 sq. fl.
Attic
CONDIGAR
G1 R-15 Gar Walls
Medium
350.0 sq. ft.
Unconditioned, attached garage
Wall Library List
Name
R -value
G1 R-15 BATT, OSB
13.423
G1 R-15 Gar Walls
11.972
2
Building Summary
Property Organization
14249 JAMES DEAN DR TSI Energy Solutions
CARMEL, IN 46033 317-846-4655
Michael Hill Inspection Status
GLO56 (AS DESIGNED) Results are projected
THE GROVE AT LEGACY 56 Builder
PYATT BUILDERS, LLC
lazing
Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft To
Assignment Top
Overhang Ft To
Bottom
C-MEnergy Solutions
Orientation Surface Area
BACK 11-.32, SHGG.31
CONDIAMB
0
0
0
West
84.0 sq. ft
FRONT 1-1-.32, SHGC-.31
CONDIAMB
0
0
0
East
103.0 sq. it.
LEFT SIDE 11-.32, SHGG.31
CONDIAMB
❑
0
❑
South
75.0 s9. fL
RIGHT SIDE 11-.32, SHGC-.31
CONDIAMB
❑
0
❑
North
148.0 sq. ft.
SLIDER 11-.32, SHGG.31
CONDIAMB
❑
❑
❑
West
40.0 sq. ft
Glazing Library List
Name
Shgc
U factor
U-32, SHGC-.31
0.31
0.320
lig
None Present
Skylight Library List
None Present
Opaque Door
Name Library Type Wall Assignment Basement Wall
Emittance
Solar
Surface Color
Surface Area
Location
Assign ment
Ab sorpta n ce
FRONT Steel Door
CONDIAMB
0.9
0.75
Medium
20.0 sq. fL
Exposed Exterior
GARAGE Steel Door
CONDIGAR
09
0.75
Medium
18.0 sq. fL
Exposed Exterior
Building Summary
Property
14249 JAMES DEAN DR
CARMEL, IN 46033
GL056 (AS DESIGNED)
THE GROVE AT LEGACY 56
paque Door Library List
Name
Steel Door
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
0.182
Inspection Status
Results are projected
C-M,
Energy Solutions
Roof Insulation
Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location
�.f.] Tiles
DRAIN R-38 Blown, GR1 1,404 No Medium 1,404.0 sq. ft Attic
Roof Insulation Library List
Name Has Radiant Barrier R -value
R-38 Blown, GR1 Na 38.268
Whale House Infiltration
InfiRration
5 ACH at 50 Pa
Mechanical Ventilation
Blower -door tested 4
None Present
Lighting
I % Interior Fluorescent °% Interior LED Lighting % Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting
Lighting Lighting Lighting
I0 ❑ 0 a ❑ ❑
4
Building Summary
Property
14249 JAMES DEAN DR
CARMEL, IN 46033
GLO56 (AS DESIGNED)
THE GROVE AT LEGACY 56
Onsite Generation
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
Onsite Generation Library List
None Present
Solar Generation
None Present
Inspection Status
Results are projected
Solar Generation Library List
None Present
Conditioning Equipment
Name Library Type Heating Percent Load
Air conditioner CA13NA030 0%
I Fuel4red air 9125A4206OS17 100%
distribution
IWater Heating RE350' 0%
quipment Type: 912SA4206OS17
Fuel Type Natural Gas
Distribution Type Forced Air
Motor Type PSC (Single Speed)
Heating Efficiency 92.1 AFUE
Heating Capacity [kBtulh] 57
Use default EAE Yes
EAE [kWh] 736.1
Coaling Percent Load
100%
0%
❑%
C-M,
Energy Solutions
L A
Hot Water Percent Load
0%
0%
100%
:j
Building Summary
Property
14249 JAMES DEAN DR
CARMEL, IN 46033
GLO56 (AS DESIGNED)
THE GROVE AT LEGACY 56
_ Equipment Type: CA13NA030
Fuel Type
Distribution Type
Motor Type
Cooling Efficiency
Cooling Capacity [kBtulh]
Equipment Type: RE350*
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity {gal.}
Hot Water Capacity [kBtulh]
Recovery Efficiency
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
Electric
Forced Air
PSC [Single Speed]
13 SEER
27.4
Inspection Status
Results are projected
M ���
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
0.98
C-M,
Energy Solutions
Building Summary
Property
Organization
14249 JAMES DEAN DR
TSI Energy Solutions
CARMEL, IN 46033
317-846-4656
Sq. Feet Served
Michael Hill Inspection Status
GLO56 (AS DESIGNED)
Results are projected
THE GROVE AT LEGACY 56
Builder
Return Duct R Value
PYATT BUILDERS, LLC
Vistribution System
Distribution Type
Forced Air
Heating Equipment
Fuel -f red air distribution
Cooling Equipment
Air conditioner
Sq. Feet Served
2449
4 Return Grilles
2
Supply Duct R Value
30
Return Duct R Value
20
Supply Duct Area [sq. ft.]
661.23
Return Duct Area [sq. ft_]
244.9
Duct Leakage to Outdoors (CFM25)
144
Total Leakage
192
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
40
Percent Return Area
40
Duct 2
Duct Location
Conditioned Space
Percent Supply Area
66
Percent Return Area
60
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Ceiling Fan
Has Ceiling Fan No
Cfm Per Watt 144
ater Distributionter
Fixture Type
Standard
e Default Hot Water Pipe Length
No
t Water Pipe Length [ft]
I
75
Least R3 Pipe Insulation?
No
t Water Recirculation System?
No
circulation System Pipe Loop Length jft]
2d
in Water Heat Recovery?
No
C-M,
Energy Solutions
Building Summary
Property
14249 JAMES DEAN DR
CARMEL, IN 46033
GLO56 (AS DESIGNED)
THE GROVE AT LEGACY 56
Clothes Dryer
Fuel Type
Cef
Field Utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I mef
Appliances and Controls
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
Electric
2.617
Timer Controls
704 kWhlYear
0.081kWh
$23.00
$0.581Therm
2.874
0.331
Programmable thermostat?
Yes
Dishwasher Size
Standard
Dishwasher Efficiency
270 kWh
Range/Oven Fuel
Electric
Convection Oven?
No
Induction Range?
No
Refrigerator Consumption
709 kWhlYear
Notes
Inspection Status
Results are projected
C-M,
Energy Solutions
L1