Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
IND SY 0078 REM Report
Building Summary Property NVR 11964 WEST ROAD ZIONSVILLE, IN 46062 Weather:Indianapolis, IN IND SY 0078 IND SY 0078.blg Organization PEG 703-934-2777 Nick Barry Builder NVR REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0078 Rater ID:4211992 Property/Builder Information Building Name IND SY 0078 Owner's Name NVR Property Address 11964 WEST ROAD City, St, Zip ZIONSVILLE, IN 46062 Phone Number Builder's Name NVR Phone Number 703-956-4231 Email Address bheuwie@nvrinc.com Plan/Model Name Rome ROM00-06 Community/Development SANCTUARY PRESERVE Permit Date/Number Organization Information Organization Name PEG Address 3975 Fair Ridge Dr, Suite T15S City, St, Zip Fairfax, VA 22033 Phone Number 703-934-2777 Website www.pegenv.com Rating/RESNET Information Provider ID 1998-109 Sample Set ID 00000000 Registry ID Registry Date Registered Rater's Name Nick Barry Rater's ID 4211992 Rater's Email nbarry@pegenv.com Last Field Insp Rating Type Projected Rating Reason for Rating New Home Rating Number IND SY 0078 Building Summary Property NVR 11964 WEST ROAD ZIONSVILLE, IN 46062 Weather:Indianapolis, IN IND SY 0078 IND SY 0078.blg Organization PEG 703-934-2777 Nick Barry Builder NVR REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0078 Rater ID:4211992 Page 2 of 14 General Building Information Area of Conditioned. Space(sq ft) 4760 Volume of Conditioned. Space 39620 Year Built 2019 Housing Type Single-family detached Level Type(Apartments Only) None Floors on or Above-Grade 2 Number of Bedrooms 4 Foundation Type Conditioned basement Enclosed Crawl Space Type N/A Number of Stories Including Conditioned Basement 3 Thermal Boundary Location REM Default Foundation Wall Information Name Library Entry Location Length(ft) Total Height(ft) Depth Below Grade(ft) Height Above Grade(ft) Uo Value Combo* Uo Value (wall only) Ambient R-13 Finished GI Cond->ambient/grn 149.0 8.0 6.0 2.0 0.066 0.097 Garage Uninsulated Cond->garage/grnd 35.0 8.0 6.0 2.0 0.282 1.506 * Uo Value Combo combines wall, airfilm, and soil path Foundation Wall Library List Foundation Wall: R-13 Finished GI Type Solid concrete or stone Thickness(in) 3.5 Studs Wood, 2x4, 16" o.c. Interior Insulation Continuous R-Value 0.0 Frame Cavity R-Value 13.0 Cavity Insulation Grade 1 Ins top 0.0 ft from top of wall Ins Bottom 0.0 ft from bottom of wall Exterior Insulation R-Value 0.0 Ins top 0.0 ft from top of wall Building Summary Property NVR 11964 WEST ROAD ZIONSVILLE, IN 46062 Weather:Indianapolis, IN IND SY 0078 IND SY 0078.blg Organization PEG 703-934-2777 Nick Barry Builder NVR REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0078 Rater ID:4211992 Page 3 of 14 Foundation Wall Library List Ins bottom 0.0 ft below grade Note Foundation Wall: Uninsulated Type Solid concrete or stone Thickness(in) 8.0 Studs None Interior Insulation Continuous R-Value 0.0 Frame Cavity R-Value 0.0 Cavity Insulation Grade 1 Ins top 0.0 ft from top of wall Ins Bottom 0.0 ft from bottom of wall Exterior Insulation R-Value 0.0 Ins top 0.0 ft from top of wall Ins bottom 0.0 ft below grade Note Slab Floor Information Name Library Entry Area(sq ft) Depth Below Grade(ft) Full Perimeter(ft) Exposed Perimeter(ft) On-Grade Perimeter(ft) Uninsulated Finished 1540 6.0 184 184 0 Slab Floor Library List Slab Floor: Uninsulated Finished Slab Covering Carpet Perimeter Insulation (R-Value) 0.0 Perimeter Insulation Depth (ft) 0.0 Under-Slab Insulation (R-Value) 0.0 Under-Slab Insulation Width (ft) 0.0 Slab Insulation Grade 1 Radiant Slab No Note Building Summary Property NVR 11964 WEST ROAD ZIONSVILLE, IN 46062 Weather:Indianapolis, IN IND SY 0078 IND SY 0078.blg Organization PEG 703-934-2777 Nick Barry Builder NVR REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0078 Rater ID:4211992 Page 4 of 14 Frame Floor Information Name Library Entry Location Area(sq ft) Uo Value Garage R-30 GI Btwn cond & garage 300 0.034 Fireplace R-30 GI Btwn cond & ambient 10 0.034 Frame Floor Library List Floor: R-30 GI Information From Quick Fill Screen Continous Insulation R-Value 0.0 Cavity Insulation R-Value 30.0 Cavity Insulation Thickness (in.) 10.0 Cavity Insulation Grade 1 Joist Size (w x h, in) 1.5 x 11.5 Joist Spacing (in oc) 16.0 Framing Factor - (default) 0.1300 Floor Covering CARPET Note Rim and Band Joist Information Name Location Area(sq ft) Continuous Ins Framed Cavity Ins Cavity Ins Thk(in) Joist Spacing Insulation Grade Uo Value Ambient Cond -> ambient 298.00 0.0 13.0 5.5 16.0 1 0.064 Garage Cond -> garage 70.00 0.0 13.0 5.5 16.0 1 0.064 Above-Grade Wall Name Library Entry Location Exterior Color Area(sq ft) Uo Value Ambient R-13 GI Cond -> ambient Medium 2653.00 0.082 Garage R-13 GI Cond -> garage Medium 315.00 0.082 Above-Grade Wall Library List Above-Grade Wall: R-13 GI Information From Quick Fill Screen Wall Construction Type Standard Wood Frame Continuous Insulation (R-Value) 0.0 Building Summary Property NVR 11964 WEST ROAD ZIONSVILLE, IN 46062 Weather:Indianapolis, IN IND SY 0078 IND SY 0078.blg Organization PEG 703-934-2777 Nick Barry Builder NVR REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0078 Rater ID:4211992 Page 5 of 14 Above-Grade Wall Library List Frame Cavity Insulation (R-Value) 13.0 Frame Cavity Insulation Thickness (in) 3.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in) 1.5 x 3.5 Stud Spacing (in o.c.) 16.0 Framing Factor - (defined) 0.1900 Gypsum Thickness (in) 0.5 Note Window Information Overhang Interior Adjacent Name Wall Assignment Orient U-Value SHGC Area (sqft) Depth (ft) To Top (ft) To Btm (ft) Winter Shading Summer Shading Winter Shading Summer Shading Front AGWall 1 Southeast 0.300 0.200 105.00 0.0 0.0 0.0 0.85 0.70 None None Right AGWall 1 Northeast 0.300 0.200 60.00 0.0 0.0 0.0 0.85 0.70 None None Right AGWall 1 Northeast 0.280 0.220 42.00 0.0 0.0 0.0 0.85 0.70 None None Rear AGWall 1 Northwes 0.300 0.200 114.00 0.0 0.0 0.0 0.85 0.70 None None Left AGWall 1 Southwes 0.300 0.200 60.00 0.0 0.0 0.0 0.85 0.70 None None Rear FndWall 1 Northwes 0.300 0.200 15.00 0.0 0.0 0.0 0.85 0.70 None None Door Information Name Library Entry Wall Assignment Opaque Area(sq ft) Uo Value R-Value of Opaque Area Storm Door Front Door Masonite AGWall 1 21.0 0.155 5.5 No Garage Door R-7 Steel AGWall 2 21.0 0.126 7.0 No Roof Information Name Library Entry Ceiling Area(sq ft) Roof Area(sq ft) Exterior Color Radiant Barrier Type Uo Value Cement or Clay Tiles Roof Tile Ventilation Attic R-38 Blown Attic GI 1675.00 2093.75 Medium No Attic 0.026 No No Morning Room R-38 Vaulted GI 170.00 170.00 Medium No Vaulted 0.028 No No Attic Access R-38 Batt Attic GI 5.00 6.25 Medium No Attic 0.041 No No Building Summary Property NVR 11964 WEST ROAD ZIONSVILLE, IN 46062 Weather:Indianapolis, IN IND SY 0078 IND SY 0078.blg Organization PEG 703-934-2777 Nick Barry Builder NVR REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0078 Rater ID:4211992 Page 6 of 14 Roof Library List Ceiling: R-38 Blown Attic GI Information From Quick Fill Screen Continous Insulation (R-Value) 25.0 Cavity Insulation (R-Value) 13.0 Cavity Insulation Thickness (in) 10.0 Cavity Insulation Grade 1 Gypsum Thickness (in) 0.500 Insulated Framing Size(w x h, in) 1.5 x 3.5 Insulated Framing Spacing (in o.c.) 24.0 Framing Factor - (defined) 0.0700 Ceiling Type Attic Note Ceiling: R-38 Vaulted GI Information From Quick Fill Screen Continous Insulation (R-Value) 0.0 Cavity Insulation (R-Value) 38.0 Cavity Insulation Thickness (in) 12.0 Cavity Insulation Grade 1 Gypsum Thickness (in) 0.500 Insulated Framing Size(w x h, in) 1.5 x 12.0 Insulated Framing Spacing (in o.c.) 24.0 Framing Factor - (default) 0.1100 Ceiling Type Vaulted Note Ceiling: R-38 Batt Attic GI Information From Quick Fill Screen Continous Insulation (R-Value) 0.0 Cavity Insulation (R-Value) 38.0 Cavity Insulation Thickness (in) 12.0 Cavity Insulation Grade 1 Gypsum Thickness (in) 0.500 Insulated Framing Size(w x h, in) 1.5 x 3.5 Insulated Framing Spacing (in o.c.) 24.0 Building Summary Property NVR 11964 WEST ROAD ZIONSVILLE, IN 46062 Weather:Indianapolis, IN IND SY 0078 IND SY 0078.blg Organization PEG 703-934-2777 Nick Barry Builder NVR REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0078 Rater ID:4211992 Page 7 of 14 Roof Library List Framing Factor - (default) 0.1100 Ceiling Type Attic Note Building Summary Property NVR 11964 WEST ROAD ZIONSVILLE, IN 46062 Weather:Indianapolis, IN IND SY 0078 IND SY 0078.blg Organization PEG 703-934-2777 Nick Barry Builder NVR REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0078 Rater ID:4211992 Page 8 of 14 Mechanical Equipment Number of Mechanical Systems 3 Heating SetPoint(F) 68.00 Heating Setback Thermostat Present Cooling SetPoint(F) 78.00 Cooling Setup Thermostat Present Heat: 92AFUE Gas Furn 80k SystemType Fuel-fired air distribution Fuel Type Natural gas Rated Output Capacity (kBtuh) 77.0 Seasonal Equipment Efficiency 92.0 AFUE Auxiliary Electric 725 Eae Note Number Of Units 1 Location Conditioned area Performance Adjustment 100 Percent Load Served 100 Cool: 13SEER A/C 3.5 ton System Type Air conditioner Fuel Type Electric Rated Output Capacity (kBtuh) 42.0 Seasonal Equipment Efficiency 13.0 SEER Sensible Heat Fraction (SHF) 0.70 Note Number Of Units 1 Location Conditioned area Performance Adjustment 100 Percent Load Served 100 DHW: 50 gal. 0.95EF Elec Water Heater Type Conventional Fuel Type Electric Building Summary Property NVR 11964 WEST ROAD ZIONSVILLE, IN 46062 Weather:Indianapolis, IN IND SY 0078 IND SY 0078.blg Organization PEG 703-934-2777 Nick Barry Builder NVR REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0078 Rater ID:4211992 Page 9 of 14 Mechanical Equipment Energy Factor 0.95 Recovery Efficiency 0.98 Water Tank Size (gallons) 50 Extra Tank Insulation (R-Value) 0.0 Note Number Of Units 1 Location Conditioned area Performance Adjustment 100 Percent Load Served 100 DHW Efficiencies All bath faucets & showers <= 2gpm false All DHW pipes fully insulated >= R-3 false Recirculation type None (standard system) Farthest fixture to DHW heater 98 TOTAL Pipelength for longest DHW run 128 DWHR unit present? false DHW Diagnostics dhwGpd 59.37 peRatio 1.17 dishwasherGpd 2.51 clothesWasherHotWaterGPD 4.48 EDeff 1.03 ewaste 36.01 tmains 57.90 dwhrWhInletTempAdj 0.00 pumpConsKwh 0.00 pumpConsMmbtu 0.00 Building Summary Property NVR 11964 WEST ROAD ZIONSVILLE, IN 46062 Weather:Indianapolis, IN IND SY 0078 IND SY 0078.blg Organization PEG 703-934-2777 Nick Barry Builder NVR REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0078 Rater ID:4211992 Page 10 of 14 Duct Systems Name Conditioned Floor Area(sq ft) 4760.0 # of Returns 4 Heating System 92AFUE Gas Furn 80k Cooling System 13SEER A/C 3.5 ton Supply Duct Surface Area(sq ft) 963.9 Return Duct Surface Area(sq ft) 714.0 Duct Leakage Qualitative Assessment Not Applicable Duct Leakage to Outside Supply+Return 0.035 CFM25 / CFA Supply Only Not Applicable Return Only Not Applicable Total Duct Leakage 0.070 CFM25 / CFA Duct Tightness Test Postconstruction Test Type Location Percent Location R-Value Supply Conditioned space 60.0 0.0 Attic, exposed 40.0 8.0 Return Conditioned space 60.0 0.0 Attic, exposed 40.0 8.0 Building Summary Property NVR 11964 WEST ROAD ZIONSVILLE, IN 46062 Weather:Indianapolis, IN IND SY 0078 IND SY 0078.blg Organization PEG 703-934-2777 Nick Barry Builder NVR REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0078 Rater ID:4211992 Page 11 of 14 Infiltration and Mechanical Ventilation Whole House Infiltration Measurement Type Blower door test Heating Season Infiltration Value 5.00 ACH @ 50 Pascals Cooling Season Infiltration Value 5.00 ACH @ 50 Pascals Shelter Class 4 Code Verification Tested Mechanical Ventilation for IAQ Type Exhaust Only Rate(cfm) 110 Sensible Recovery Efficiency(%) 0.00 Total Recovery Efficiency(%) 0.00 Hours per Day 13.1 Fan Power (watts) 36.00 ECM Fan Motor false Ventilation Strategy for Cooling Cooling Season Ventilation Natural Ventilation Building Summary Property NVR 11964 WEST ROAD ZIONSVILLE, IN 46062 Weather:Indianapolis, IN IND SY 0078 IND SY 0078.blg Organization PEG 703-934-2777 Nick Barry Builder NVR REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0078 Rater ID:4211992 Page 12 of 14 Lights and Appliances Rating/RESNET audit Ceiling Fan CFM / Watt 0.00 Refrigerator kWh/yr 703 Refrigerator Location Conditioned Range/Oven Fuel Type Natural gas Induction Range No Convection Oven No Dishwasher Energy Factor 0.78 Dishwasher kWh/yr 0 Place Setting Capacity 12 Clothes Dryer Fuel Type Electric Location Conditioned Moisture Sensing No CEF 2.62 Clothes Washer Location Conditioned LER (kWh/yr) 704 IMEF 0.331 Capacity (CU.Ft) 2.874 Electricity Rate 0.08 Gas Rate 0.58 Annual Gas Cost 23.00 Qualifying Light Fixtures Interior CFLs % 90.0 Interior Fluorescent % 0.0 Exterior Lights % 0.0 Garage Lights % 0.0 Building Summary Property NVR 11964 WEST ROAD ZIONSVILLE, IN 46062 Weather:Indianapolis, IN IND SY 0078 IND SY 0078.blg Organization PEG 703-934-2777 Nick Barry Builder NVR REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0078 Rater ID:4211992 Page 13 of 14 Mandatory Requirements IECC Requirements Verified IECC 04 true Verified IECC 06 true Verified IECC 09 true Verified IECC 12 false Verified IECC 15 false Verified NY-ECCC 2016 false Verified IECC MI false EPA Requirements Rater certifies that the home complies with the following requirements for: None Rater Design Review Checklist(National) Rater Field Checklist(National) HVAC Design Report HVAC Commissioning Checklist (optional) ENERGY STAR Version 3 Appliances Amount Refrigerators 1 Ceiling Fans 0 Exhaust Fans 0 Dishwashers 1 ENERGY STAR Version 3 Basements Basement Wall Area 50% Below Grad: true Basement Floor Area 1540.00 2009 IECC Prescriptive Requirements for ENERGY STAR v3.0 false Slab Insulation Exemption: false Indoor airPlus Verification Checklist false EPA Field App ID Building Summary Property NVR 11964 WEST ROAD ZIONSVILLE, IN 46062 Weather:Indianapolis, IN IND SY 0078 IND SY 0078.blg Organization PEG 703-934-2777 Nick Barry Builder NVR REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0078 Rater ID:4211992 Page 14 of 14 DOE Zero Energy Ready Home Home Builder ID Number Mandatory Requirements Verified Fenestration false Verified Insulation false Verified Duct Location false Verified Appliance false Verified Lighting false Verified Fan Efficiency false Verified Water Efficiency false Verified EPA Indoor airPLUS false Verified Renewable Energy Ready Solar Electric false Optional Home Builder Commitments for Recognition Certified under the EPA WaterSense for New Homes Program No Certified under the IBHS fortified for Safer Living Program No Followed the DOE Zero Energy Ready Home Quality Management Guidelines No The buyer of this home signed a waiver giving DOE Zero Energy Ready Home access to utility bill data for one year. No Active Solar System Type None Collector Loop Type None Collector Type None Collector Orientation None Area(sq ft) 0.0 Tilt(degrees) 0.0 Volume(cu ft/gal) 0.0 Notes 2009 IECC Energy Cost Compliance Property NVR 11964 WEST ROAD ZIONSVILLE, IN 46062 Weather:Indianapolis, IN IND SY 0078 IND SY 0078.blg Organization PEG 703-934-2777 Nick Barry Builder NVR HERS Projected Rating Rating No:IND SY 0078 Rater ID:4211992 REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. Annual Energy Cost $/yr 2009 IECC As Designed Heating 1659 1605 Cooling 333 255 Water Heating 494 494 SubTotal - Used to Determine Compliance 2485 2353 Lights & Appliances 1136 1118 Photovoltaics -0 -0 Service Charge 120 120 Total 3741 3591 Mandatory Requirements Annual Energy Cost Check PASSES Duct Insulation R-Value Check (per Section 405.2)PASSES Window U-Value and SHGC Check (per Section 402.5)PASSES Home Infiltration (Section 402.4.2)PASSES Duct Leakage (Section 403.2.2)PASSES Mandatory Requirements Check Box (2009 IECC)PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code based on a climate zone of 5A. In fact, this home surpasses the requirements by 5.3%. Name Nick Barry Signature Organization PEG Date 21 February 2019 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. Home Energy Rating CertificateHERS Index: 70REM/Rate - Residential Energy Analysis and Rating Software v15.4.2This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado.The Home Energy Rating Standard Disclosure for this home is available from the rating provider.Projected Rating: Based on Plans - Field Confirmation Required.General InformationConditioned Area 4760 sq. ft. House Type Single-family detachedMechanical Systems FeaturesHeating: Fuel-fired air distribution, Natural gas, 92.0 AFUE.Building Shell FeaturesCeiling Flat R-38.0 Slab R-0.0 Edge, R-0.0 UnderLights and Appliance FeaturesPercent Interior Lighting 90.00 Range/Oven Fuel Natural gas TITLEEstimated Annual Energy CostUse MMBtu Cost PercentHeating 111.5 $1441 45%Conditioned Volume 39620 cubic ft. Foundation Conditioned basementCooling: Air conditioner, Electric, 13.0 SEER.Sealed Attic NA Exposed Floor R-30.0Percent Garage Lighting 0.00 Clothes Dryer Fuel ElectricCompanyCooling 4.3 $137 4%Bedrooms 4Water Heating: Conventional, Electric, 0.95 EF, 50.0 Gal.Vaulted Ceiling R-38.0 Window Type U-Value: 0.300, SHGC: 0.200Refrigerator (kWh/yr) 703 Clothes Dryer CEF 2.62AddressHot Water 13.1 $421 13%Duct Leakage to Outside 166.60 CFM25.Above Grade Walls R-13.0 Infiltration Rate Htg: 5.00 Clg: 5.00 ACH50Dishwasher Energy Factor 0.78 Ceiling Fan (cfm/Watt) 0.00City, State, ZipLights/Appliances 36.7 $1118 35%Ventilation System Exhaust Only: 110 cfm, 36.0 watts.Foundation Walls R-13.0 Method Blower door testPhone #Photovoltaics -0.0 $-0 -0%Programmable Thermostat Heat=Yes; Cool=YesFax #Service Charges $120 4% Total 165.5 $3237 100%Property HERSNVR Rating Type: Projected Rating Certified Energy Rater: Nick Barry11964 WEST ROAD Rating Date: Rating Number: IND SY 0078ZIONSVILLE, IN 46062 Registry ID:CriteriaThis home meets or exceeds the minimum criteria for the following: