Loading...
HomeMy WebLinkAboutSY 78 sewer10701 N. College Avenue Suite A Indianapolis, Indiana 46280 phone 31748449200 fax 317-844-9203 www.trico.eco Residential SANITARY SEWER PERMIT 999913191 Permit Type Final Subdivision Sanctuary at 116th St Project WO 2018-1367 Section Number 26 Project Name Sanctuary at 116th Street Section 2B Lot Number 78 Project Developer CESO Inc. Address Number 11964 Lift Station Treatment Plant Parcel Acreage EDU in Gallons 17 Zion Hills Station Address 2 Local Sewer Charge - District Contribution Plan Review and Inspection Application Fee EDU Fee Interceptor Fee Other Fees Fees Due Invoice Number CTRWD WWTP Street West Road 0.27 City Zionsville 310 Zip Code County Builder 46077 Hamilton Ryan Homes 0.00 0.00 150.00 Phone Number 317-371-6577 1908.00 Owner 0.00 Phone Number 0.00 2058.00 Occupant Phone Number PLEASE NOTE: Installation of building sewer shall be per the specifications of the TriCo Regional Sewer Utility (see reverse) and any conditions noted below. All installations shall be inspected by TriCo personnel during "open trench" phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundation drains, or other sources of ground or stormwater, shall be permitted to enter TriCo's sanitary sewer system. TriCo will assume no liability for drains which are below the grade level of the nearest downstream manhole nor for laterals which are extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder) will be responsible for damages to TriCo's sewer system. This includes damages to manholes, castings, manhole lids and the like; caused by construction activity on the building site which is the subject of this permit. Inspections by TriCo are MANDATORY and shall be arranged by contacting TriCo's office at 844-9200 24 hours in advance. All new construction will be placed on billing two months after connection has been made or when water is connected, whichever comes first. The building has: Main ID: SNT842-SNT841 Grease Trap Slab Foundation USMH SNT-842 SNT-841 DSMH Grease Interceptor Crawl Space Manhole IDs Grit Interceptor Basement YES Lid Elevation 905.92 909.25 ,/ Grinder Station First Floor Elevation 910.271 91027 Water Service City of Carmel Baserrmnt Fldvation 9 01.41 1 901.41 ✓/ Calculation is based on both Manhole Lid Elevations and the ,Ievation of the Fir3t door 4,35' 1.02 Ft. Per Ordinance 9-13-99 and the elevations provided, the substruct, re s.l?all be plumbed by: Ejector Pump Only a TriCo currently requires that an ISI inspection is perfonrr:,i ) : ompliance, is issued prior to occupancy 1 sale of a properrty. Please review attached Ill Permit. ___ -- GC Manholes shall remain accessible at all times. Burial ;r: sit ;z-. wi ; 'I -o rortected by the Developer/Owner. The proper class of cleanout must be installed every 100 feet of latest pipe measured from sewer main to structure. The terms of the conditional permit, if any, are listed below. Plans have been submitted. All fees have been paid. No certificate of insurance required. No additional permits required. No manhole core permit required. The facility is not classified as a FOG facility. (Notes) By signing below, I attest that I am fa 1larwith the Dis ict's specifications and agree to accept responsibility for all Builder I Owner Signature /L,i��KIA„ Phone Number_ rT Printed Name Approved By Ryan a an, District Engineer Permit is valid' r O -YEAR from the date issued. Permit valid only with 0 done under this permit. F� _ -r- m 01 r 56 in d i Z O 9Y C @\� t �f� �'t4 M1IlT CW N R