Loading...
HomeMy WebLinkAboutC705-DETAILS-Rev.1Aqua-Swirl Concentrator Model AS-9 Off-Line Standard Detail AS-9 STDDocument: Drawn By: Scale: Date: BLR 12/20/07 1:30 1. System shall be designed for the following capacities: Peak Treatment Flow: 14.2 cfs [402 L/s] Sediment Storage: 145 ft³ [4.1 m³] Oil/Debris Storage: 910 gal. [3444 L] STANDARD NOTE: U.S. Patent No. 6524473 and other Patent Pending Swirl Inlet 68" [1727 mm] Ø119 5/8" [Ø3038 mm] A Inlet20" [508 mm] OD Max Riser Varies Reinforced Top Grade (Rim) Manhole Frame and Cover by Manufacturer. (See Details) 132" [3353 mm] Arched Baffle Outlet A 20" [508 mm] OD Max Octagonal Base Plate Vent Rim elevations to match finished grade. HDPE risers can be field cut by Contractor. 132" [3353 mm] 32" [813 mm] OD Plan View Vent Arched Baffle Section A-A Undisturbed Soil 42" [1067 mm] Backfill Bedding12" [305 mm] STORMWATER TREATMENT SOLUTIONS Phone (888) 344-9044 www.aquashieldinc.com ™ 114" [2896 mm] Swirl Outlet ™ Phone (888) 344-9044 Fax (423) 826-2112 2705 Kanasita Drive, Chattanooga, TN 37343 www.aquashieldinc.com STORMWATER TREATMENT SOLUTIONS * Please see accompanied Aqua-Swirl specification notes. * See Site Plan for actual system orientation. 2ULHQWDWLRQPD\YDU\IURPƒƒRU custom angles to meet site conditions. 90° ** 4 1/2" [114 mm] Concrete Gravel Backfill Place small amount of concrete to support and level manhole frame. DO NOT allow manhole frame to rest upon HDPE riser. Soil 1/2" [13 mm] 1/2" [13 mm] Manhole Frame & Cover Detail NTS For Non-Traffic Areas Only Cover Frame Riser Concrete Gravel Backfill Soil 1/2" [13 mm] Bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles. 4 1/2" [114 mm] Gravel Backfill Paving 1/2" [13 mm] Manhole Frame & Cover Detail NTS For H-20 Traffic Loading Areas Cover Frame Riser 1/2" [13 mm] Concrete Gravel Backfill Paving 3" [76 mm] Typ. 10" [254 mm] Concrete 1/2" [13 mm] If traffic loading (H-20) is required or anticipated, a concrete pad must be placed over the entire Stormwater Treatment System. Sample details of concrete pad available upon request. Pipe coupling by Contractor. 12" [305 mm] long Stub-out by Manufacturer. Pipe coupling by Contractor. 12" [305 mm] long Stub-out by Manufacturer. Gravel Backfill shall extend at least 3.5 feet [1067 mm] outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below) Reinforced Top AQUASWIRL CONCENTRATOR DETAIL ADDITIONAL ADA RAMP & SIDEWALK DETAILS POND CONTROL STR#1 OFFSITE POND CONTROL STR #2 CKD.DR.DES.DATEPROJECT No:REVISIONDATENo.THE PROSCENIUM CARMEL DEVELOPMENT II, LLCWEST CARMEL DRIVE & SOUTH RANGELINE ROADCARMEL, INDIANA7635 Interactive WaySuite 100Indianapolis, IN 46278317.299.7500FAX: 317.291.5805C705 DETAILSPOND OUTLET PLAN