Loading...
HomeMy WebLinkAboutEP-601-SINGLE-LINE-DIAGRAM-AND-PANEL-AND-LIGHT-SCHEDULES-Rev.1Panel Schedule PANEL NAME:VOLTAGE PHASE:WIRE:NEUTRAL RATING: PANEL DESCRIPTION: GLP 277/480V 3 4 100%GARAGE LIGHTING PANEL MAINS: MOUNTING: MAX. NO. OF CIRCUITS: MANUFACTURER: PANEL A.I.C. RATING: LOCATION: 400A MCB SURFACE 66 SQUARE D 65k RISER ROOM BRANCH VA Load Load VA BRANCH NO DESCRIPTION POLES BKR A B C Type Type A B C BKR POLES DESCRIPTION NO. 1 GARAGE LIGHTING 1 20 2295 L E 1140 20 3 EF-1 2 3 GARAGE LIGHTING 1 20 1785 L E 1140 4 5 GARAGE LIGHTING 1 20 378 L E 1140 6 7 GARAGE EMERGENCY LIGHTING 1 20 1105 L E 1140 20 3 EF-2 8 9 PLUMBING HEAT TRACE 1 20 500 E E 1140 10 11 SPARE 1 20 E 1140 12 13 UH-6 3 20 1666 E E 1140 20 3 EF-3 14 15 1666 E E 1140 16 17 1666 E E 1140 18 19 UH-7 3 20 1666 E E 1140 20 3 EF-4 20 21 1666 E E 1140 22 23 1666 E E 1140 24 25 UH-8 3 20 1666 E E 1140 20 3 EF-5 26 27 1666 E E 1140 28 29 1666 E E 1140 30 31 UH-9 3 1666 E E 1140 20 3 EF-6 32 33 1666 E E 1140 34 35 1666 E E 1140 36 37 SPACE E SPACE 38 39 SPACE E SPACE 40 41 SPACE E SPACE 42 43 DWBP-1 3 50 7066 E SPACE 44 45 7066 E SPACE 46 47 7066 E SPACE 48 49 DPAC-1 1 20 2300 E SPACE 50 51 SPACE SPACE 52 53 SPACE SPACE 54 55 SPACE SPACE 56 57 SPACE SPACE 58 59 SPACE SPACE 60 61 SPACE E 2746 60 3 PANEL GRP 62 63 SPACE E 2526 64 65 SPACE E 2526 66 Total A B C SUM % LIGHTING [L] 3400 1785 378 5563 7 RECEPTS [R] 0 0 0 0 0 EQUIP. [E] 25616 23596 23096 72308 93 OTHER 0 0 0 0 0 ADDITIONAL 0 0 0 0 0 TOTAL 29016 25381 23474 77871 CONNECTED (AMPS): 94 AMPS DEMAND 20311 17767 16432 54510 70 DEMAND (AMPS): 66 AMPS % 37 33 30 Panel Schedule PANEL NAME:VOLTAGE PHASE:WIRE:NEUTRAL RATING: PANEL DESCRIPTION: GRP 120/208V 3 4 100%GARAGE RECEPTACLE PANEL MAINS: MOUNTING: MAX. NO. OF CIRCUITS: MANUFACTURER: PANEL A.I.C. RATING: LOCATION: 60A MCB SURFACE 24 SQUARE D 24k RISER ROOM BRANCH VA Load Load VA BRANCH NO DESCRIPTION POLES BKR A B C Type Type A B C BKR POLES DESCRIPTION NO. 1 RCPT- RISER ROOM 1 20 720 R E 1666 30 3 UH-5 2 3 TRAP PRIMERS 1 20 500 E E 1666 - -4 5 FIRE ALARM CONTROL PANEL 1 20 500 E E 1666 - -6 7 RCPT-FAN MAINTENANCE 1 20 460 R - - -8 9 RCPT-FAN MAINTENANCE 1 20 460 R - - -10 11 RCPT-FAN MAINTENANCE 1 20 460 R - - -12 13 - - -- - -14 15 - - -- - -16 17 - --- - -18 19 - - -- - -20 21 - - -- - -22 23 - --- - -24 Total A B C SUM % LIGHTING [L] 0 0 0 0 0 RECEPTS [R] 1180 460 460 2100 26 EQUIP. [E] 1666 2166 2166 5998 74 OTHER 0 0 0 0 0 ADDITIONAL 0 0 0 0 0 TOTAL 2846 2626 2626 8098 CONNECTED (AMPS):23 AMPS DEMAND 1992 1838 1838 5669 70 DEMAND (AMPS):16 AMPS % 35 32 32 TG U400A-4A GLP* 400 MCB 277/480V 3Ø-4W 40A-3A FEEDER SCHEDULE 40A-3A (3)#6 AWG AL & (1)#8 AWG AL GND IN 1-1/2" C. U400A-4A (2) SETS OF (4)#250 KCMIL AL., (1) #0 AL GND IN 3-1/2" C. EACH GRP* 60A MCB 120/208V 3Ø-4W SQUARE D MINI POWER ZONE 30 KVA 480V - 120/208V 3Ø-4W NOTES:FIXTURE SYMBOLQUANTITY LAMPS/LIGHT ENGINE FLUOR.INCAN.H.I.D.1. L.E.D.WATTS/LAMPG.E. LAMPSCAT. NO.FIXTURE VOLTAGEFIXTURE INPUT WATTSFIXTURE EFFICIENCYDELIVERED LUMENSMANUFACTURER & CATALOG NO. OTHER ACCEPTABLE MANUFACTURERS DIFFUSER MEDIA CLASSIFICATON EM--EMERGENCY N--NORMAL HAZ--HAZARDOUS HB--HIGH BAY LB--LOW BAY HM--HIGH MAST S--SURFACE R--RECESSED SM--STEM MTD. WM--WALL MTD. C--CHAIN MTD. UC--UNDER CAB. CS--CEIL. SURF. T--TRACKWHITENICKELCHROMEBRUSHED ALUM.STANDARDSEE NOTETRIM COLOR MOUNTING SIZE (IN.)DIAMETER ORWIDTHLENGTHDEPTHSEE NOTEL14 ---N/A LED 42 * PG1 ---N/A LED 85 MOUNT FIXTURES 8'-0" AFF. MOUNT TO CEILING OR PROVIDE CHAIN MOUNTING AS REQUIRED. 1 1 277 N/A N/A 8K COLUMBIA #LCL4-40ML-EU KIM LIGHTING #PGL71W/E45/60L4K277/PS/SF LITHONIA, PHILIPS - FROSTED POLYCARBONATE PRISMATIC ACRYLIC N N * CS OR C S 12"48"3" -18"DIA 7.5"277 PG2 ---N/A LED 851 N/A 8.7K KIM LIGHTING #PGL71N/E45/60L4K277/PS/SF -PRISMATIC ACRYLIC N *S -18"DIA 7.5"277 5.4K LITHONIA, PHILIPS LITHONIA, PHILIPS ---N/A LED 51 N/A DUAL-LITE #SESRWE -N/A EM *CS -11.75"10 1.5"277 LITHONIA, PHILIPS ---N/A LED 101 N/A -N/A EM *CS -11.75"10 1.5"277 LITHONIA, PHILIPS N/A N/A DUAL-LITE #SEDRWE Sheet Name: Proj. No.: Date: 02/22/18 - GARAGE PERMIT 074904The Proscenium DevelopmentCarmel Development II, LLC.GarageIntersection of Carmel Dr. and Rangeline Rd.Carmel, Indiana 46032ARCHITECTURE ENGINEERING GEOSPATIAL 03/08/18 1 2 3 4 5 6 7 8 9 A B C D E F G 7635 Interactive Way Suite 100 Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 Issuances: REV DESCRIPTION DATE BIM 360://74904 - Proscenium - R18/74904 Garage - ELEC R18.rvt3/13/2018 3:49:32 PMSINGLE LINE DIAGRAM AND PANEL AND LIGHT SCHEDULES EP-601 SCALE : N.T.S.1 SINGLE LINE DIAGRAM SCALE : N.T.S.2 PANEL GLP SCALE : N.T.S.3 PANEL GRP SCALE : N.T.S.4 FIXTURE SCHEDULE 0 Issued For Garage Permit 02/22/18