HomeMy WebLinkAboutGP-000-COVER-SHEET-Rev.1The Proscenium Development
VICINITY MAP
GARAGE:
1203 Walnut Street, Second Floor
Cincinnati, OH 45202
Fax: 937.461.0743
www.woolpert.com
WOOLPERT
Tel: 513.272.8300
PROJECT TEAM
PROJECT
SITE
PROJECT IMAGE
PROJECT LOCATION:
PROJECT NAME:
GOVERNING BUILDING CODE:
PROJECT TYPE:
INTERSECTION OF CARMEL DRIVE AND RANGELINE ROAD - HAMILTON
COUNTY, INDIANA
THE PROSCENIUM DEVELOPMENT - GARAGE / PODIUM
2014 INDIANA BUILDING CODE (2012 INTERNATIONAL BUILDING CODE)
2014 INDIANA FIRE CODE (2012 INTERNATIONAL FIRE CODE)
PARKING GARAGE, WITH FUTURE BUILDINGS ON TOP
GENERAL NOTES
LOCATION MAP
PROJECT
SITE
PROJECT INFORMATION
A. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS IN THE FIELD PRIOR TO ORDERING OR
FABRICATION OF MATERIALS OR THE BEGINNING OF CONSTRUCTION. NOTIFY ARCHITECT AND OWNER
REPRESENTATIVE OF ALL DISCREPANCIES. ALL WORK REQUIRING MEASURING TO BE DONE ACCORDING TO
FIGURES ON DRAWINGS. DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND DRAWINGS SHALL BE BROUGHT TO
THE IMMEDIATE ATTENTION OF THE ARCHITECT AND OWNER REPRESENTATIVE. CONTRACTOR TO SUBMIT
SPECIFIC DISCREPANCY FOR ARCHITECT REVIEW, PRIOR TO COMMENCING WITH THE WORK IN QUESTION.
B. ALL WORK TO CONFORM TO LOCAL CODES, ORDINANCES AND REQUIREMENTS.
C. THE CONTRACTOR SHALL ARRANGE FOR THE PREMISES TO BE MAINTAINED IN AN ORDERLY MANNER, FREE OF
DUST AND DEBRIS,THROUGHOUT THE COURSE OF THE WORK. PROVIDE AND MAINTAIN TEMPORARY BARRICADES
AS REQUIRED TO PROTECT THE PUBLIC AND OWNERS PERSONNEL DURING CONSTRUCTION. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE EXISTING STRUCTURE OR EQUIPMENT. ANY SUCH DAMAGE
SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE.
D. CONTRACTOR SHALL PROVIDE DAILY OR MORE FREQUENT GENERAL CLEAN UP IN COMPLIANCE WITH OWNER'S
REQUIREMENTS OF AREAS WITHIN THE LIMITS OF CONSTRUCTION, AND FINAL CLEAN UP AT CONCLUSION OF
WORK.
E. CONTRACTOR TO REVIEW OTHER DRAWINGS ISSUED FOR THIS PROJECT FOR ADDITIONAL INFORMATION FROM
OTHER TRADES TO COORDINATE THE REQUIRED SCOPE OF WORK.
F. DO NOT SCALE FROM THE DRAWINGS. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE. THE OWNER'S
REPRESENTATIVE MUST BE NOTIFIED OF ANY CONFLICTS IN DIMENSIONING.
G. EXTERIOR DIMENSIONS ARE TO FACE OF BRICK VENEER OR FACE OF METAL STUD, BRICK VENEER, MASONRY
OPENING, OR COLUMN CENTERLINE UNLESS OTHERWISE NOTED. INTERIOR DIMENSIONS ARE TO FACE OF
EXTERIOR STUD, FACE OF MASONRY, FACE OF CONCRETE, CENTERLINE OF COLUMNS, OR FACE OF INTERIOR
STUD UNLESS OTHERWISE NOTED.
H. ALL MATERIALS, FIXTURES AND EQUIPMENT INDICATED IN THE CONSTRUCTION DOCUMENTS SHALL BE NEW AND
AS SPECIFIED, UNLESS IDENTIFIED OTHERWISE.
I. ALL NEW FINISHED AND PATCHED SURFACES SHALL BE SMOOTH, CONTINUOUSLY FREE OF IMPERFECTIONS AND IN
PROPER CONDITION TO RECEIVE THE SPECIFIED FINISH. PATCHED AREAS SHALL MATCH THE ADJACENT
MATERIALS CONSTRUCTION AND FINISH.
J. ALL FLOORS ON EITHER SIDE OF A DOORWAY OR OPENING SHALL BE LEVEL AND HAVE MAXIMUM ELEVATION
DIFFERENCE OR THRESHOLD HEIGHT OF 1/2".
K. DOOR OPENINGS NOT LOCATED BY DIMENSION SHALL BE 4" FROM THE FACE OF STUD TO FACE OF STUD OF DOOR
FRAME JAMB UNLESS NOTED OTHERWISE.
L. DOOR SIZES, STYLES, AND SPECIFICATIONS, ROUGH OPENING SIZES AND EXACT LOCATIONS TO BE CHECKED AND
VERIFIED BY THE CONTRACTOR BEFORE ORDERING AND BEFORE CONSTRUCTION BEGINS.
M. ALL PENETRATIONS OF FIRE RATED FLOORS, WALLS AND CEILINGS TO BE SEALED WITH PROPER APPROVED
MATERIALS TO THE FULL THICKNESS OF THE CONSTRUCTION ELEMENTS.
N. FIRE STOP ALL FLOORS, WALLS AND CEILINGS AS REQUIRED BY APPLICABLE CODE.
O. ALL WOOD BLOCKING IN EXTERIOR WALLS TO BE MOISTURE RESISTANT TREATED IN ACCORDANCE WITH
SPECIFICATIONS. WHERE REQUIRED BY CODE, ALL WOOD BLOCKING IN INTERIOR WALLS TO BE FIRE RETARDANT
TREATED IN ACCORDANCE WITH SPECIFICATIONS.
P. INSTALL SEALANT AT EXTERIOR SIDE OF ALL JOINTS, SEAMS, CONNECTIONS OR OPENINGS WHICH WOULD ALLOW
WATER OR AIR INFILTRATION EXCEPT AS NOTED OTHERWISE. SEALANT COLOR TO MATCH ARCHITECT'S SAMPLE.
COLOR REQUIRES ARCHITECT'S APPROVAL.
Q. PROVIDE FIRE EXTINGUISHER COMPLYING WITH NFPA 10, AS INDICATED ON LIFE SAFETY DRAWINGS WITH MAX
TRAVEL DISTANCE OF 75'.
R. ALL METAL STUDS AND OR FURRNING SHALL BE 20 GAGE MINIMUM, UNLESS NOTES OTHERWISE.
S. MASONRY CONTROL JOINTS ARE SHOWN FOR REFERENCE ONLY, LOCATIONS OF CONTROL JOINTS SHALL BE PER
THE NATIONAL BRICK INDUSTRY ASSOCIATION GUIDELINES.
T. THE LOCATIONS OF EXISTING UTILITIES HAVE BEEN PREPARED FROM DOCUMENTS PROVIDED BY THE OWNER AND
MAY NOT REPRESENT THE ACTUAL FIELD CONDITIONS. CONTRACTOR TO REVIEW ALL OWNER DOCUMENTS AND
BECOME FAMILIAR WITH ALL EXISTING UTILITIES. THE CONTRACTOR HAS THE RESPONSIBILITY TO VERIFY
LOCATIONS IN THE FIELD BY EMPLOYING FIELD UTILITY LOCATING SERVICES BEFORE CONSTRUCTION STARTS, AND
COORDINATE ALL NEW UTILITY LOCATIONS, CONNECTIONS AND PENETRATIONS.
U. THE SUBCONTRACTOR SHALL VERIFY AND COORDINATE, WITH ALL TRADES, THE SIZES AND LOCATIONS OF ALL
OPENINGS FOR MECHANICAL, PLUMBING, AND ELECTRICAL EQUIPMENT, EQUIPMENT PADS, OR BASES AS WELL AS
POWER, WATER, AND DRAIN INSTALLATIONS BEFORE PROCEEDING WITH WORK. SUBCONTRACTOR SHALL
PROVIDE COORDINATION DRAWINGS FOR PROPER PLACEMENT OF ALL TRADES' WORK. ALL CONCERNS, SPACE
LIMITATIONS OR STRUCTURAL CONFLICTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT,
PRIOR TO COMMENCING WITH THE WORK IN QUESTION.
V. IT IS THE SUBCONTRACTOR'S RESPONSIBILITY TO COORDINATE AND LOCATE ELECTRICAL, DATA, AND PHONE
RECEPTACLES, SWITCHES, ETC. TO AVOID CONFLICTS WITH CASEWORK, DOORS, AND OTHER TRADES.
W. ARCHITECTURAL DATUM 100'-0" = FINISHED FLOOR
CODE INFORMATION
ISSUED FOR GARAGE PERMIT
JULY 2, 2018
CHAPTER 3
USE GROUP:
CHAPTER 5
AREA AND HEIGHT LIMITATIONS:
CHAPTER 6
CONSTRUCTION TYPE:
S-2 – STORAGE (PARKING GARAGE) = 176,040 SF
BUILDING CONSTRUCTION TYPE
PARKING GARAGE (S-2) = 1A
STORIES AND AREAS
PARKING GARAGE (S-2) = 1A = UNLIMITED
SECTION 510 – SPECIAL PROVISIONS
HORIZONTAL SEPARATIONS MUST COMPLY WITH THE FOLLOWING
• 3-HR FIRE RESISTANCE RATING
• THE BUILDING BELOW IS NOT GREATER THAN ONE STORY ABOVE
GRADE
• THE BUILDING BELOW IS OF TYPE 1A CONSTRUCTION
• ANY SHAFT, STAIRWAYS, RAMP, OR ESCALATOR MUST BE IN IN A 2-
HOUR RATED ENCLOSURE
• THE BUILDING BELOW IS PROTECTED BY AN AUTOMATIC FIRE
SPRINKLER SYSTEM, PER NFPA 13.
SECTION 510.9 MULTIPLE BUILDINGS ABOVE A HORIZONTAL ASSEMBLY SHALL BE
REGARDED AS SEPARATE BUILDINGS
1A
PRIMARY STRUCTURAL FRAME = 3-HR
BEARING WALLS
EXTERIOR = 3-HR
INTERIOR = 3-HR
NON-BEARING WALLS
INTERIOR = 0-HR
BUILDING CODE INFORMATION
CHAPTER 7
FIRE / SMOKE PROTECTION
CHAPTER 9
FIRE SUPPRESSION:
CHAPTER 10
NUMBER OF EXITS:
TRAVEL DISTANCE:
COMMON PATH OF TRAVEL:
OCCUPANCY LOAD :
SECTION 713 - SHAFT ENCLOSURES SHALL HAVE A FIRE RESISTANCE RATING OF NOT
LESS THAN 2-HR.
- STAIRWELLS SHALL HAVE 2-HR RATING
- ELEVATOR SHAFTS SHALL HAVE 2-HR RATING
THIS BUILDING WILL HAVE AN AUTOMATIC FIRE SUPPRESSION SYSTEM MEETING
NFPA 13 REQUIREMENTS
3 - BETWEEN 500 AND 1,000 OCCUPANTS (S-2),4 EXISTS PROVIDED
400 FT PER TABLE 1016.2 (S-2)
100 FT PER TABLE 1014.3 (S-2)
S-2 PARKING GARAGE (@200 GROSS) 176,040 SF = 881 OCC
4454 Idea Center Blvd
Dayton, OH
45430-1500
937.461.5660
Fax: 937.461.0743
Proj. No.:
Date:
Issuances:
Sheet Name:
REV DESCRIPTION DATE
BIM 360://74904 - Proscenium - R18/74904 Garage - ARCH R18.rvt7/2/2018 1:38:46 PMThe Proscenium DevelopmentGarageCarmel Development II, LLC.Intersection of Carmel Dr. and Rangeline Rd. Carmel, Indiana 4603202/22/18 - GARAGE PERMIT
074904
02/22/18
COVER SHEET
GP-000
0 Issued For Foundation Permit 01/30/18
1 Issued For Garage Permit 07/02/18