HomeMy WebLinkAboutLSP-101-LIFE-SAFETY-PLAN-Rev.1WATER
SERVICES
RM
ELEVATOR
2A ELEVATOR
5A323' -0"
299' -2"
368' -0"
350' - 0"
EXIT 1
34"0.15 60"
221
400
EXIT 2
34"0.15 60"
221
400
EXIT 4
34"0.15 60"
221
400
EXIT 3
34"0.15 60"
221
400
176,040 SF S-2
38811/200
PARK. GARAGE
STAIR 2A
STAIR 3A
ELEVATOR
3A
STAIR 7AELEVATOR
6A
ELEVATOR
6B
STAIR 6A
FUTURE BUILDINGS
PODIUM LIMITS
STAIR 5A
HORIZONTAL EXIT
FEC
FEC
FEC
FEC FEC
FECFEC
FECFECFEC
FEC
FEC
FEC FEC
FECFECFEC EPEPEPEP EPEP
TRASH
LIFE SAFETY LEGEND
EGRESS ELEMENT
1 HOUR RATED
FIRE BARRIER
EGRESS WIDTH
(REQUIRED)
EGRESS WIDTH
(PROVIDED)
OCCUPANTS SERVED
(PROVIDED)
REQUIRED ELEMENT
WIDTH
REQUIRED S.F. PER
OCCUPANT
DENOTES EXIT
DISCHARGE
START
POINT
DENOTES EXIT
ROUTE
TRAVEL
DISTANCE
100' -6"
OCCUPANTS SERVED
(REQUIRED)
EXIT
20"0.2 32"
100
160
6000 SF B
2601 / 100
BUSINESS
SPACE AREA
FUNCTION OF SPACE
NUMBER OF OCCUPANTS
NUMBER OF REQUIRED
EXITS
OCCUPANCY
CLASSIFICATION
EXIT SIGN -SEE
ELECTRICAL
SEMI-RECESSED PORTABLE FIRE
EXTINGUISHER CABINET WITH
PORTABLE FIRE EXTINGUISHER PER
NFPA 72 AS SELECTED BY LOCAL FIRE
MARSHALL. REFER TO DETAIL 10/A-602.
FEC
EXIT
WALL MOUNTED PORTABLE FIRE
EXTINGUISHER PER NFPA 72 AS
SELECTED BY LOCAL FIRE MARSHALL.
FE
2 HOUR RATED
FIRE BARRIER
EMERGENCY PHONE EP
4454 Idea Center Blvd
Dayton, OH
45430-1500
937.461.5660
Fax: 937.461.0743
Proj. No.:
Date:
Issuances:
Sheet Name:
REV DESCRIPTION DATE
BIM 360://74904 - Proscenium - R18/74904 Garage - ARCH R18.rvt3/16/2018 10:01:22 AMThe Proscenium DevelopmentGarageCarmel Development II, LLC.Intersection of Carmel Dr. and Rangeline Rd. Carmel, Indiana 4603202/22/18 - GARAGE PERMIT
074904
02/22/18
LIFE SAFETY PLAN
LSP-101
SCALE : 3/64" = 1'-0"
PARKING LEVEL LIFE SAFETY PLAN
CHAPTER 3
S-2 –STORAGE (PARKING GARAGE)= 176,040 SF
CHAPTER 4
PARKING GARAGE WILL BE CLASSIFIED AS “ENCLOSED”AND MUST FOLLOW ALL OF
SECTION 404 AND SECTION 406.6
SECTION 404
• CLEAR HEIGHT MUST BE HIGHER THAN 7’, WE HAVE DECIDED TO USE A
10’-4”MAX HEIGHT BUT NO LESS THAN 7’.
• VEHICLE RAMPS ARE NOT CONSIDERED A MEAN OF EGRESS UNLESS
PEDESTRIAN PATHS ARE ADDED. MUST HAVE A SLOPE THAT DOES NOT
EXCEED 1:15
• PARKING GARAGES MUST BE SEPARATED FROM OTHER OCCUPANCIES
PER 508.1 (2 HOUR RATING)
SECTION 406.6
• VENTILATION REQUIREMENTS PER IMC
• AUTOMATIC FIRE SUPPRESSION SYSTEM IS REQUIRED (DRY PIPE SYSTEM
IS RECOMMENDED)
CHAPTER 5
BUILDING CONSTRUCTION TYPE
PARKING GARAGE (S-2) = 1A
STORIES AND AREAS
PARKING GARAGE (S-2) = 1A = UNLIMITED
SECTION 510 –SPECIAL PROVISIONS
HORIZONTAL SEPARATIONS MUST COMPLY WITH THE FOLLOWING
• 3-HR FIRE RESISTANCE RATING
• THE BUILDING BELOW IS NOT GREATER THAN ONE STORY ABOVE GRADE
• THE BUILDING BELOW IS OF TYPE 1A CONSTRUCTION
• ANY SHAFT, STAIRWAYS, RAMP, OR ESCALATOR MUST BE IN IN A 2-HOUR
RATED ENCLOSURE
• THE BUILDING BELOW IS PROTECTED BY AN AUTOMATIC FIRE SPRINKLER
SYSTEM, PER NFPA 13.
SECTION 510.9 MULTIPLE BUILDINGS ABOVE A HORIZONTAL ASSEMBLY SHALL BE
REGARDED AS SEPARATE BUILDINGS
CHAPTER 6 –TYPES OF CONSTRUCTION CHAPTER 9 –FIRE PROTECTION
THE BUILDING WILL BE PROTECTED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM
COMPLYING WITH NFPA 13.
CHAPTER 10 –MEANS OF EGRESS
OCCUPANCY COUNTS –TABLE 1004.1.2
PARKING GARAGE (S-2) @200 GROSS = 881 OCCUPANTS
4 EXITS PROVIDED AT 221 OCCUPANTS EACH (3 EXITS REQUIRED)
45" CLEAR AT STAIRS (44" REQUIRED), 60" CLEAR AT CORRIDORS (44" REQUIRED),
34" CLEAR AT DOORS (34" REQUIRED)
SECTION 1005 MEANS OF EGRESS SIZING
• CORRIDORS AND OTHER AREAS = 0.15 INCHES/OCCUPANT (SPRINKLERED)
• STAIRWELLS FOR EGRESS = 0.2 INCHES/OCCUPANT (SPRINKLERED)
• 44”CLEAR MINIMUM.BETWEEN HANDRAILS.
SECTION 1007 ACCESSIBLE MEANS OF EGRESS
• WHERE MORE THAN ONE MEANS OF EGRESS IS REQUIRED FROM ANY
ACCESSIBLE SPACE, EACH ACCESSIBLE SPACE MUST BE SERVED BY NOT
LESS THAN TWO ACCESSIBLE MEANS OF EGRESS.
OTHER MEANS OF EGRESS ITEMS
• NO AREAS OF REFUGE ARE REQUIRED AS THE BUILDING IS A PARKING
GARAGE.
• EXITS MUST DISCHARGE PER SECTION 1027.
PARKING COUNT: 511
ADA COUNT: 11 (11 REQUIRED)
ADA VAN COUNT: 4 (2 REQUIRED)
NORTH
0 Issued For Foundation Permit 01/30/18