Loading...
HomeMy WebLinkAboutMP-001-HVAC-LEGEND-&-PROJECT-NOTES-Rev.1S H T 1-01 RTU 12 4 H-100 4 H-100 ANNOTATION SYMBOL LEGEND A-8"ø 250 8"ø 24x12 THERMOSTAT OR TEMP. SENSOR HUMIDISTAT SWITCH KEYNOTE DESIGNATION VAV TERMINAL UNIT MARK AIR DEVICE MARK - NECK SIZE AIRFLOW ROUND DUCT SIZE RECTANGULAR DUCT SIZE POINT OF NEW CONNECTION EQUIPMENT PLAN MARK SECTION SYMBOL DETAIL SYMBOL AIR DEVICE AND DUCT ACCESS. LEGEND SUPPLY AIR DIFFUSER (HARD CONNECTION) RETURN OR EXH. GRILLE (HARD CONNECTION) RETURN AIR GRILLE SIDEWALL DIFFUSER SUPPLY AIR DIFFUSER WITH FLEXIBLE RUNOUT AND DAMPER SUPPLY AIR DIFFUSER (HARD CONNECTION) RETURN OR EXHAUST GRILLE (HARD CONNECTION) 14X14 TRANSFER OPENING IN WALL TRANSFER OPENING IN WALL OUTDOOR UNITODU PC PLUMBING CONTRACTOR PRESSURE DROPPD PAINT GRIP GALVANIZED STEELPGGS PP POLYPROPYLENE PARTS PER MILLIONPPM PRESS.PRESSURE PRESSURE REGULATING VALVEPRV PS PRESSURE SENSOR POLY VINYL CHLORIDEPVC PVCGS PVC COATED GALVANIZED STEEL RETURN AIRRA REFRIG. RECT RC ROOM CRITERIA LEVEL RECTANGULAR REFRIGERANT MATT FACED FIBERGLASSMFF A AMPS HVAC ABBREVIATION LEGEND ROOF MOUNTED CENTRIFUGAL FAN RETURN OR RELIEF FAN RMC RF SQUARESQ LEAVING WET BULB TEMPERATURELWB HEATING HOT WATERHW FLOW SWITCH FEED WATER NATURAL GASG FW FS SWEAT CONNECTION SOLVENT WELD THERMOSTATT SWLD SW CONDENSER WATER PUMPCWP CONDENSER WATERCW CU COPPER CHILLED WATER PUMPCHP CHILLED WATER SUPPLYCHWS CHILLED WATER RETURNCHWR CUBIC FEET PER MINUTECFM MANUAL DAMPERMD MINIMUM CIRCUIT AMPSMCA MECHANICAL CONTRACTORMC 1000 BTUHMBH MATERIALMAT. MOTORIZEDM LEAVING WATER TEMPERATURELWT LOUVERLVR LOW PRESSURE STEAMLPS LIQUID PROPANELP LEAVING DRY BULB TEMPERATURELDB LEAVING AIR TEMPERATURELAT INLINE CENTRIFUGAL FANILC HOT WATER SUPPLYHWS HOT WATER RETURNHWR HOT WATER PUMPHWP HOT WATER BOILERHWB HEATING/VENTILATING UNITHV HUMIDITY SENSORHS HIGH PRESSURE STEAMHPS HORSE POWERHP HOT GAS (REFRIGERANT)HG HEAT FUSIONHF HEATING CONTRACTORHC HUMIDIFIER (HUMIDITY)H GALVANIZED STEELGS GROOVED PIPEGRV GALLONS PER MINUTEGPM GALLONS PER HOURGPH GENERAL CONTRACTORGC GALVANIZEDGALV GA GAGE (GAUGE) DRAIND TC TOTAL CAPACITY DB DECIBELS TEMP.TEMPERATURE DCW DOMESTIC COLD WATER TH THICKNESS DDC DIRECT DIGITAL CONTROLS THRD THREADED DHW DOMESTIC HOT WATER TOD TOP OF DUCT DMPR DAMPER TOJ TOP OF JOIST DS DUCT SILENCER (SOUND ATTENUATOR) TOS TOP OF STEEL DT DUAL TEMPERATURE TS TEMPERATURE SENSOR DTP DUAL TEMPERATURE PUMP T/S PIPE TYPE OR SCHEDULE DTR DUAL TEMPERATURE RETURN UBC UPBLAST CENTRIFUGAL FAN DTS DUAL TEMPERATURE SUPPLY UC FLEXIBLE UNICELLULAR E-AL EMBOSSED ALUMINUM UH UNIT HEATER EAT ENTERING AIR TEMPERATURE UV UNIT VENTILATOR EC ELECTRICAL CONTRACTOR EDB ENTERING DRY BULB TEMPERATURE EF EXHAUST FAN EH ELECTRIC HEATER V VOLTS EWB ENTERING WET BULB TEMPERATURE VAV VARIABLE AIR FLOW EWT ENTERING WATER TEMPERATURE VC VENTILATING CONTRACTOR EXH EXHAUST WCS WROUGHT CARBON STEEL F FURNACE WCU WROUGHT COPPER FCU FANCOIL UNIT WLD WELDED CONNECTION FD FIRE DAMPER WMP WALL MOUNTED PROPELLER FAN FFJ FOIL FACED JACKET WPD WATER PRESSURE DROP FG FIBERGLASS WT WEIGHT (OR DENSITY) FGB FIBERGLASS BOARD INSULATION FGW FIBERGLASS WRAP FLA FULL LOAD AMPS FLG FLANGE FLGD FLANGED FMG FOAM GLASS FPM FEET PER MINUTE FPP FAN POWERED PARALLEL VAV FPS FAN POWERED SERIES VAV STAINLESS STEELSS COOLING TOWERCT SHUT OFF VALVE TERMINALSO CARBON STEELCS SUPPLY FANSF CONDENSATE RETURN PIPECRP SCREWED (THREADED)SCR STEAM CONDENSATE RETURNCR SCHEDULESCH CHLORINATED PVCCPVC SENSIBLE CAPACITYSC CONCRETECONC. SUPPLY AIRSA CEILING MOUNTED CENTRIFUGAL FANCMC SWITCHS CENTERLINE OF PIPECLP RELIEF VALVERV CENTERLINECL CAST IRONCI ROOF TOP UNITRTU ROOF MOUNTED PROPELLER FANRMP CHILLED WATERCHW REFRIGERANT LIQUIDRL CHILLERCH CUBIC FEETCF CALCIUM CARBONATE POWDERCCP CALCIUM SILICATE INSULATIONCAL CORRUGATED ALUMINUMC-AL BRAZEDBR BOTTOM OF PIPEBOP BOTTOM OF DUCTBOD BRAKE HORSE POWERBHP BACKDRAFT DAMPERBDD BUILDING AUTOMATION SYSTEMBAS STEAM BOILERB ON CENTERO.C. ALL SERVICE INSULATION JACKETASJ OPPOSED BLADE DAMPEROBD AIR PRESSURE DROPAPD OUTSIDE AIROA ALUMINUMALUM NOISE CRITERIA LEVELNC ABOVE FINISHED FLOORAFF MAKE UP AIRMUA ACR COPPER REFRIG PIPEACR MALLEABLE IRONMI AIR COOLED CONDENSING UNITACC HEAT RECLAIM WATERHRC PIPE SYMBOL LEGEND FEED WATER PIPEFW CR NATURAL GAS PIPE VENT PIPE LPS MPS RL RS RHG LPG DTS DTR DHW CHWS CHWR HWS HWR DCW CWR CWS G V HPS DUAL TEMPERATURE SUPPLY PIPE DUAL TEMPERATURE RETURN PIPE HEATING HOT WATER SUPPLY PIPE HEATING HOT WATER RETURN PIPE CONDENSATE RETURN PIPE CONDENSER WATER RETURN PIPE CONDENSER WATER SUPPLY PIPE LOW PRESSURE STEAM PIPE MEDIUM PRESSURE STEAM PIPE REFRIGERANT LIQUID PIPE REFRIGERANT SUCTION PIPE REFRIGERANT HOT GAS PIPE LIQUID PROPANE GAS PIPE DOMESTIC HOT WATER PIPE CHILLED WATER SUPPLY PIPE DOMESTIC COLD WATER PIPE CHILLED WATER RETURN PIPE HIGH PRESSURE STEAM PIPE 30-240deg. F UNION TEE DOWN PIPE UP PIPE DOWN CAPPED PIPE TEE UP BALL VALVE BUTTERFLY VALVE GAS SHUT-OFF VALVE CALIBRATED BALANCE VALVE PRESSURE REGULATING VAVLE GATE VAVLE GLOBE VALVE STRAINER BLIND FLANGE PIPE BREAK (FOR CLARITY) STRAINER WITH BLOW DOWN VALVE MOTORIZED 2-WAY VALVEM M MOTORIZED 3-WAY VALVE PRESSURE RELIEF VALVE 0-100psig PRESSURE GAGE THERMOMETER M RETURN OR EXHAUST AIR DUCT DOWN DUCTWORK SYMBOL LEGEND FIREDAMPER MOTORIZED DAMPER MANUAL BALANCING DAMPER SUPPLY/ OUTSIDE AIR DUCT OFFSET RETURN AIR DUCT OFFSET RETURN OR EXHAUST AIR DUCT UP SUPPLY OR OUTSIDE AIR DUCT DOWN SUPPLY OR OUTSIDE AIR DUCT UP RECTANGULAR BRANCH TAKEOFF RECTANGULAR DUCT TERMINATION ROUND DUCT TERMINATION ROUND WYE ROUND ELBOW ROUND OFFSET ROUND DUCT DOWN SUPPLY OR OUTSIDE AIR ROUND DUCT UP RADIUS RECTANGULAR ELBOW STANDARD RECTANGULAR ELBOW RECTANGULAR TRANSITION RECTANGULAR TO ROUND TRANSITION A-24x12 250 GLYS GLYR ICE WATER SUPPLY PIPE ICE WATER RETURN PIPE SCHEMATIC SYMBOL LEGEND M AUTOMATIC 2-WAY CONTROL VALVE AUTOMATIC 3-WAY CONTROL VALVEM AUTOMATIC FLOW CONTROLLER CHECK VALVE FLEXIBLE CONNECTION GAUGE, T-TEMPERATURE; P-PRESSURE T/P MANUAL BALANCE VALVE PIPE REDUCER/INCREASER PRESSURE REDUCING VALVE SHUTOFF VALVE COMBINATION BALANCE-SHUTOFF VALVE TRIPLE DUTY VALVE; SHUTOFF-BALANCE-CHECK TDV DIRECTION OF FLOW AIR VENT, MV-MANUAL VENT; AV- AUTOMATIC VENT MV/AV SAFETY RELIEF VALVE AHU-1 EQUIPMENT MARK RETURN OR EXHAUST AIR ROUND DUCT UP XXX 1.INSTALL THE H.V.A.C. SYSTEM AS INDICATED IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. 2.COORDINATE ALL WORK WITH OTHER TRADES. REWORK OF PIPING, DUCTWORK, EQUIPMENT LOCATION, CONDUIT, ETC. AS A RESULT OF POOR PLANNING. COORDINATION OR SCHEDULING SHALL BE THE RESPONSIBILITY OF THE INVOLVED CONTRACTORS. NOTIFY THE ARCHITECT/ENGINEER OF ANY CONFLICTS PRIOR TO START OF WORK. 3.THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ANY FRAMING REVISIONS, EQUIPMENT LOCATIONS, ADDITION OF CONTROLS, ELECTRICAL CIRCUITING REVISIONS, ETC. THAT RESULT FROM 4.USING EQUIPMENT OTHER THAN THOSE INDICATED ON THE DRAWINGS. APPROVAL OF THE SHOP DRAWINGS BY THE ARCHITECT/ENGINEER WILL NOT WAIVE THE CONTRACTOR OF THIS RESPONSIBILITY. 5.THE MECHANICAL CONTRACTOR SHALL HAVE THE FINAL RESPONSIBILITY FOR SYSTEM START UP, TRAINING, WARRANTY AND TURN OVER TO THE OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTRUCTING THE OWNER ON ANY ROUTINE MAINTENANCE REQUIRED DURING THE WARRANTY PERIOD. 6.ALL ITEMS INCLUDED ON THESE DRAWINGS AND THE SPECIFICATIONS SHALL BE INCLUDED IN THE CONTRACTORS BID. ANY ITEMS THAT ARE UNCLEAR OR FOUND TO BE INCORRECT BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER PRIOR TO THE BID DUE DATE. EXCLUSIONS OF WORK FROM THE BID ARE NOT ACCEPTABLE. 7.ALL WORK INDICATED ON THE MECHANICAL DRAWINGS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE. 8.THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL FIRESTOPPING FOR DUCT AND PIPE PENETRATIONS THAT PENETRATE FIRE RATED ASSEMBLIES. SEE ARCHITECTURAL DRAWINGS OR REFER TO THE OWNERS RECORD DRAWINGS FOR LOCATIONS OF FIRE RATED ASSEMBLIES. ALL FLOOR PENETRATIONS SHALL BE FIRESTOPPED AND SEALED WATER TIGHT WITH A FLEXIBLE SEALANT. INSTALL PER MFG. RECOMMENDATIONS. 9.THE MECHANICAL CONTRACTOR SHALL COORDINATE ANY ROOF PATCHING FOR ANY MECHANICAL ROOF PENETRATIONS NOT SPECIFICALLY IDENTIFIED ON THE ARCHITECTURAL DRAWINGS. ALL PATCHING SHALL BE PROVIDED BY GENERAL CONTRACTOR AND BE PERFORMED IN A MANNER CONSISTENT WITH THE ROOF SYSTEMS CURRENT WARRANTY REQUIREMENTS AND MANUFACTURERS RECOMMENDATIONS. 10.THE MECHANICAL CONTRACTOR SHALL NOT PERFORM ANY WELDING OR TORCH CUTTING OPERATIONS WITHIN THE OCCUPIED BUILDING WITHOUT OBTAINING PERMISSION OR A BURN PERMIT FROM THE OWNER. GENERAL: 1.THE H.V.A.C. EQUIPMENT AND SYSTEM SHALL NOT BE USED TO DURING CONSTRUCTION. THE WARRANTY PERIOD SHALL NOT BEGIN UNTIL SUBSTANTIAL COMPLETION. THE CONTRACTOR SHALL EXTEND THE EQUIPMENT WARRANTY PERIOD AS NECESSARY WHEN EQUIPMENT IS USED AFTER INITIAL START UP AND PRIOR TO SUBSTANTIAL COMPLETION. EQUIPMENT - GENERAL 1.ALL DUCTWORK SHALL BE CONSTRUCTED, INSTALLED AND SUPPORTED PER THE LATEST VERSION OF THE S.M.A.C.N.A. H.V.A.C. DUCT CONSTRUCTION STANDARDS. UNLESS SPECIFIED MORE STRINGENTLY IN THESE CONSTRUCTION DOCUMENTS. 2.COORDINATION OF DUCT SYSTEM INSTALLATION WITH OTHER TRADES SHALL BE PERFORMED PRIOR TO THE FABRICATION OF ANY DUCTWORK. VERIFY DUCT CLEARANCES PRIOR TO FABRICATION. NOTIFY THE ARCHITECT/ENGINEER OF ANY CONFLICTS THAT REQUIRE DIMENSIONAL CHANGES OR REQUIRE MAJOR RELOCATION OF DUCTWORK. 3.ALL DUCTWORK SHALL BE SUPPORTED FROM ROOF OR FLOOR STRUCTURE ABOVE. DUCTWORK SHALL NOT LAY ON TOP OF CEILING OR LIGHT FIXTURES. 4.ALL DUCTWORK SIZES SHOWN ARE EXTERNAL DIMENSIONS. ALLOWANCE HAS BEEN MADE FOR 1" DUCTLINER WHERE AND IF REQUIRED. 5.RECTANGULAR DUCTWORK SHALL BE SUPPORTED PER THE S.M.A.C.N.A. STANDARDS AND AT EACH CHANGE IN DIRECTION. DUCTWORK - GENERAL: PROJECT NOTES 1.PROVIDE PROJECT SPECIFIC CONTROL SYSTEM MANUAL FOR THE BUILDING. THE MANUAL SHALL CONTAIN A DIAGRAM OF THE CONTROL SYSTEM ARCHITECTURE, WIRING DIAGRAMS AND A SEQUENCE OF OPERATION. THE MANUAL SHALL ALSO INCLUDE AN 11 X 17 FLOOR PLAN INDICATING THE MAJOR EQUIPMENT AND PANEL LOCATIONS. THE MANUAL SHALL BE BOUND IN A HARD BACK 3 RING BINDER WITH DIVIDERS. BINDER SHALL BE LABELED "H.V.A.C TEMPERATURE CONTROL MANUAL" AND INCLUDE THE PROJECT NAME AS WELL AS THE BUILDING NAME, NUMBER AND ADDRESS. 2.LABEL ALL CONTROL PANELS, ACTUATORS, SENSORS, ETC WITH 1/8" THICK PLASTIC LAMINATE SIGNS. SEE DRAWINGS FOR LABEL AND LETTERING REQUIREMENTS. LABEL DESIGNATIONS SHALL BE CONSISTENT WITH THE DRAWINGS, TEMPERATURE CONTROL SYSTEM MANUAL AND DIAGRAMS. 3.MOUNT WALL MOUNTED THERMOSTATS, TEMPERATURE SENSORS AND CARBON MONOXIDE SENSORS 4'-0" ABOVE FINISH FLOOR. DO NOT MOUNT THERMOSTATS OR TEMPERATURE SENSORS IN DIRECT SUNLIGHT OR NEAR HEAT PRODUCING EQUIPMENT. 4.THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL INTERFACE WIRING REQUIRED BETWEEN THE TEMPERATURE CONTROL SYSTEM AND THE FIRE ALARM SYSTEM. THE ELECTRICAL CONTRACTOR SHALL PROVIDE THE INTERFACE TERMINALS AS PART OF THE FIRE ALARM SYSTEM AS REQUIRED TO PROVIDE THE SPECIFIED SEQUENCE OF OPERATION. 5.THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL MOTOR STARTERS AND DISCONNECT SWITCHES FOR H.V.A.C. EQUIPMENT UNLESS THEY ARE INCLUDED WITH THE EQUIPMENT AS INDICATED ON THE DRAWINGS AND IN THE SPECIFICATIONS. COORDINATE STARTER REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR AND THE CONTRACTOR PRIOR TO ORDERING. 6.WHERE AUXILIARY CONTACTS ARE REQUIRED IN STARTERS PROVIDED BY THE ELECTRICAL CONTRACTOR, THE MECHANICAL CONTRACTOR SHALL COORDINATE THE QUANTITY AND TYPE OF CONTACTS WITH THE E.C. PRIOR TO PURCHASE. 7.THE ELECTRICAL CONTRACTOR SHALL PROVIDE CIRCUIT BREAKERS IN THE ELECTRICAL PANELS THAT ARE SPECIFICALLY DEDICATED FOR THE TEMPERATURE CONTROL SYSTEM. COORDINATE THE QUANTITY AND SIZES WITH THE CONTRACTOR. SEE ELECTRICAL DRAWINGS FOR LOCATION. 8.THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL TEMPERATURE CONTROL SYSTEM WIRING AND CONDUIT REGARDLESS OF VOLTAGE AS REQUIRED TO PROVIDE THE SPECIFIED SEQUENCE OF OPERATION OR SATISFY ANY MANUFACTURER REQUIREMENTS. POWER AND CONTROL WIRING AND CONDUIT FOR VALVE ACTUATORS, DAMPER ACTUATORS, CARBON MONOXIDE SENSORS, TEMPERATURE CONTROL PANELS, RELAYS, INDICATOR LIGHTS, REMOTE CONTROL PANELS, SOLENOID VALVES AND OTHER SIMILAR DEVICES THAT ARE PART OF THE H.V.A.C SYSTEM SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. SEE ELECTRICAL DRAWINGS FOR THE LOCATION OF CIRCUIT BREAKERS SPECIFICALLY DEDICATED FOR TEMPERATURE CONTROL SYSTEM COMPONENTS. ALL 120 V CONTROL WIRING SHALL BE INSTALLED IN CONDUIT. CONCEALED ABOVE CEILING PLENUM RATED LOW VOLTAGE (24 VOLTS OR LESS) CONTROL WIRING DOES NOT REQUIRE TO BE INSTALLED IN CONDUIT. 9.THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL CONTROLS, RELAYS, SENSORS, CONTROLLERS, CONTROL TRANSFORMERS, CONTROL INTERFACE COMPONENTS, SOFTWARE, HARDWARE, ACTUATORS, SWITCHES AND ANY OTHER CONTROL COMPONENTS REQUIRED TO PROVIDE THE SPECIFIED SEQUENCE OF OPERATIONS ON PLANS, TO INTEGRATE PROJECT CONTROLS AND SYSTEM, AND TO MEET EQUIPMENT MANUFACTURER'S INSTALLATION AND OPERATION REQUIREMENTS, UNLESS NOTED OTHERWISE ON PLANS. 10.IT SHALL BE THE MECHANICAL CONTRACTORS RESPONSIBILITY TO COORDINATE ALL TEMPERATURE CONTROL SYSTEM REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR PRIOR TO THE PURCHASE OR INSTALLATION OF ANY OF THE ELECTRICAL POWER OR TEMPERATURE CONTROL SYSTEM COMPONENT. 11.ALL DAMPERS ON THE INLET OR OUTLET OF THE FAN SHALL BE OPEN PRIOR TO STARTING THE FAN. PROVIDE ANY TIME DELAYS OR END SWITCHES AS REQUIRED. 12.PROVIDE CLEAR PLASTIC VENTED IMPACT RESISTANT LOCKABLE GUARDS ON ALL WALL MOUNTED THERMOSTATS OR SENSORS WITH ADJUSTABLE SET-POINTS. PROJECT NOTES CONTROL NOTES: 1.PROVIDE PLASTIC LAMINATE IDENTIFICATION LABELS ON ALL EQUIPMENT SCHEDULED ON THE DRAWINGS. THE IDENTIFICATION SHALL BE CONSISTENT WITH THE PLANMARKS SHOWN ON THE DRAWINGS AND THE BAS SYSTEM USER INTERFACE. SEE DETAILS ON DRAWINGS REGARDING COLOR, SIZE, TEXT HEIGHT, ETC. 2.PROVIDE PLASTIC LAMINATE IDENTIFICATION LABELS ON ALL TEMPERATURE CONTROL COMPONENTS SUCH AS CONTROL PANELS, TEMPERATURE SENSORS, HUMIDITY SENSORS, ETC. THE IDENTIFICATION SHALL BE CONSISTENT WITH THE PLANMARKS SHOWN ON THE DRAWINGS WHERE AVAILABLE AND THE BAS SYSTEM USER INTERFACE. SEE DETAILS ON DRAWINGS REGARDING COLOR, SIZE, TEXT HEIGHT, ETC. 3.PLASTIC LAMINATE SIGNS AND LABELS ON OUTDOOR EQUIPMENT SHALL BE FIXED TO EQUIPMENT WITH STAINLESS STEEL OR ALUMINUM RIVETS OR STAINLESS STEEL OR PLATED SCREWS. 4.CLEAN EQUIPMENT AND PIPING PRIOR TO AFFIXING ADHESIVE TYPE LABELS AND SIGNS. IDENTIFICATION: DESIGN CRITERIA INDOOR DESIGN CONDITIONS STAIRWELL WINTER DRY BULB:60.0°FBUILDING LOCATION: LATITUDE: LONGITUDE: ELEVATION: SUMMER DRY BULB: SUMMER WET BULB: WINTER DRY BULB: OUTDOOR DESIGN CONDITIONS GENERAL DESIGN INFORMATION CARMEL, INDIANA 39.97 86.13 853 91.3°F (0.4% ASHRAE DESIGN CONDITION) 75.0°F (0.4% ASHRAE DESIGN CONDITION) 2.6°F (99.6% ASHRAE DESIGN CONDITION) Sheet Name: Proj. No.: Date: 02/22/18 - GARAGE PERMIT 074904TheProsceniumDevelopmentCarmelDevelopmentII,LLC.GarageIntersectionofCarmelDr.andRangelineRd.Carmel,Indiana46032ARCHITECTURE ENGINEERING GEOSPATIAL 02/22/18 1 2 3 4 5 6 7 8 9 A B C D E F G 7635 Interactive Way Suite 100 Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 Issuances: REV DESCRIPTION DATE BIM360://74904-Proscenium-R18/74904Garage-MECHPLUMBR18.rvt7/2/20189:55:19AMHVAC LEGEND & PROJECT NOTES MP-001 0 Issued for Garage Permit 02/22/18