Loading...
HomeMy WebLinkAboutMP-601-HVAC-SCHEDULES-&-SEQUENCE-OF-OPERATIONS-Rev.1Sheet Name: Proj. No.: Date: 02/22/18 - GARAGE PERMIT 074904TheProsceniumDevelopmentCarmelDevelopmentII,LLC.GarageIntersectionofCarmelDr.andRangelineRd.Carmel,Indiana46032ARCHITECTURE ENGINEERING GEOSPATIAL 02/22/18 1 2 3 4 5 6 7 8 9 A B C D E F G 7635 Interactive Way Suite 100 Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 Issuances: REV DESCRIPTION DATE BIM360://74904-Proscenium-R18/74904Garage-MECHPLUMBR18.rvt7/2/20189:55:21AMHVAC SCHEDULES & SEQUENCE OF OPERATIONS MP-601 PLAN MARK TYPE ELECTRICAL SERVICE CFM ESP ("WC) WHEEL SIZE DRIVE SONES HP VOLT PHASE NOTES FAN SCHEDULE NOTES: 1 PROVIDE WITH MOTOR SAFETY GUARD HOUSING WITH BIRDSCREEN 2 VARIABLE FREQUENCY DRIVE 3 PROVIDE MANUFACTURER APPROVED SUSPENSION WITH VIBRATION ISOLATION 4 INTERFACE WITH CO MONITOR SYSTEM 5 PROVIDE DISCONNECT SWITCH. INSTALLED BY E.C. 6 WALL HOUSING EF-1 GREENHECK MODEL SE2-48 GARAGE 21,875 0.25"-DIRECT 40 3 480 3 1, 2, 3, 4, 5, 6 PLAN MARK AREA SERVED ELECTRICAL MFR MODEL TYPE CFM KW V/PH MCA NOTES ELECTRIC HEATER SCHEDULE MARK NO: UH NOTES: 1 INTERNAL TEMPERATURE DOUBLE POLE THERMOSTAT/CIRCUIT BREAKER DISCONNECT 2 DISCONNECT PROVIDED BY E.C. 3 PROVIDE WALL MOUNTING BRACKET 4 PROVIDE RECESSED WALL MOUNT KIT 5 NEMA PREMIUM EFFICIENCY MOTOR UH-1 STAIRWELL MARKEL 3450 WALL 245 5 208/3 -1, 2, 4, 5 LENGTH 14 1/4" DIMENSIONS HEIGHT 23 1/16" DEPTH 4 1/4" RECESS YES MARK NO: EF EF-2 GARAGE 21,875 3 480 3 EF-3 GARAGE 21,875 3 480 3 EF-4 GARAGE 21,875 3 480 3 EF-5 GARAGE 21,875 3 480 3 EF-6 GARAGE 21,875 3 480 3 UH-2 STAIRWELL MARKEL 3450 WALL 5 -YES UH-3 STAIRWELL MARKEL 3450 WALL 5 -YES UH-4 STAIRWELL MARKEL 3450 WALL 5 -YES UH-5 STAIRWELL MARKEL 3450 WALL 5 -YES UH-6 UH-7 UH-8 STORAGE ROOM MARKEL UH SUSPENDED 400 5 480/3 -20"13"11"NO UH-9 STORAGE ROOM MARKEL UH SUSPENDED 5 480/3 -NO STORAGE ROOM MARKEL UH SUSPENDED 5 480/3 -NO STORAGE ROOM MARKEL UH SUSPENDED 5 480/3 -NO 245 245 245 245 14 1/4"23 1/16"4 1/4" 14 1/4"23 1/16"4 1/4" 14 1/4"23 1/16"4 1/4" 14 1/4"23 1/16"4 1/4" 400 400 400 20"13"11" 20"13"11" 20"13"11" - - - - - MARK MFR LOUVER SCHEDULE NOTES: L-1 AIROLITE 1,2 NOTES 1 COLOR TO BE SELECTED BY ARCHITECT FROM MANUFACTURER STANDARD COLORS. 2 PROVIDE WITH BIRDSCREEN AREA WELL LOUVER DESCRIPTION MODEL K6776 MOUNTING WALL FINISH KYNAR MATERIAL ALUM.- ACCESSORIES BASIS OF DESIGN MARK NO: L 208/3 208/3 208/3 208/3 1, 2, 4, 5 1, 2, 4, 5 1, 2, 4, 5 1, 2, 4, 5 1, 2, 3, 5 1, 2, 3, 5 1, 2, 3, 5 1, 2, 3, 5 ELECTRIC UNIT HEATERS (UH-1 THRU UH-9) FAN: 1.THE FAN SHALL CYCLE ON A CALL FOR HEATING. HEATING ELEMENT: 1.ON A FALL BELOW THE SPACE HEATING SET POINT OF 60°F(ADJ.), THE HEATER SHALL TURN ON UNTIL SPACE HEATING SET POINT IS SATISFIED. MONITORING AND CONTROL POINTS (MINIMUM LISTED, PROVIDE ADDITIONAL POINTS AS NECESSARY TO PROVIDE THE SPECIFIED SEQUENCE OF OPERATION). 1.FAN STATUS 2.FAN ON/OFF 3.SPACE TEMPERATURE 4.SENSOR NORM/FAIL STATUS SEQUENCE OF OPERATIONS EXHAUST FANS (EF-1 THRU EF-6) 1.THREE LEAD EXHAUST FANS SHALL RUN CONTINUOUSLY AT MINIMUM SPEED. TWO GROUPS OF LEAD EXHAUST FANS SHALL ROTATE WEEKLY BETWEEN EF-1, EF-3, EF-5 AND EF-2, EF-4, EF-6. MINIMUM GARAGE EXHAUST CFM SHALL NEVER DROP BELOW 8,750 CFM TOTAL. 2.WHEN CARBON MONOXIDE LEVELS OF 25 PPM OR GREATER ARE SENSED, LEAD EXHAUST FANS SHALL RAMP UP TO 50% FOR 5 MINUTES (ADJ.) TO REDUCE LEVELS BELOW 25 PPM. AFTER 5 MINUTES IF THE CO LEVELS ARE ABOVE 25 PPM THE LEAD FANS SHALL RAMP UP TO 80% FOR 10 MINUTES (ADJ.). ONCE CO LEVELS HAVE BEEN REDUCE TO BELOW 25 PPM, THE LEAD EXHAUST FANS SHALL STAY CONSTANT FOR 20 MINUTES BEFORE RAMPING BACK DOWN TO MINIMUM SPEED. 3.IF THREE LEAD EXHAUST FANS REACH 80% SPEED WITHOUT MAINTAINING CO CONCENTRATION FOR 10 MINUTES (ADJ.), THE LEAD EXHAUST FANS SHALL RAMP DOWN TO 50% SPEED WHILE THE REMAINING THREE LAG FANS SHALL START AT 50% SPEED. ALL FANS SHALL SIMULTANEOUSLY RAMP UP FROM 50% AS NEEDED TO MEET AND MAINTAIN CO CONCENTRATION LEVELS BELOW 25 PPM. ONCE CO LEVELS ARE REDUCED TO BELOW 25 PPM, THE FANS SHALL REMAIN CONSTANT FOR 20 MINUTES (ADJ.). AFTER 20 MINUTES, ALL FANS SHALL RAMP DOWN TO 50% SPEED. ONCE THE FANS HAVE RAMPED DOWN TO 50% SPEED AND CO LEVELS ARE BELOW 25 PPM, THE LAG FANS SHALL TURN OFF AND LEAD FANS SHALL RAMP DOWN TO MINIMUM SPEED. ALARMS: ALARMS (MINIMUM LISTED , PROVIDE ADDITIONAL POINTS AS NECESSARY TO PROVIDE THE SPECIFIED SEQUENCE OR OPERATION) 1.FAN FAILURE (DRIVE OR MOTOR) MONITORING AND CONTROL POINTS (MINIMUM LISTED, PROVIDE ADDITIONAL POINTS AS NECESSARY TO PROVIDE THE SPECIFIED SEQUENCE OF OPERATION) 1.FAN STATUS 2.FAN ENABLE/DISABLE 3.FAN VARIABLE FREQUENCY DRIVE OUTPUT (%) 1, 2, 3, 4, 5, 6 1, 2, 3, 4, 5, 6 1, 2, 3, 4, 5, 6 1, 2, 3, 4, 5, 6 1, 2, 3, 4, 5, 6 40 40 40 40 40 DIRECT DIRECT DIRECT DIRECT DIRECT 0.25" 0.25" 0.25" 0.25" 0.25" GREENHECK MODEL SE2-48 GREENHECK MODEL SE2-48 GREENHECK MODEL SE2-48 GREENHECK MODEL SE2-48 GREENHECK MODEL SE2-48 0 Issued for Garage Permit 02/22/18