HomeMy WebLinkAboutP-103-GARAGE-UNDERGROUND-PLUMBING-PLAN---AREA-C-Rev.1P-502
2
A
B
C
D
E
F
H
16 17 18 19 20 21 22 23 24P-202P-106
MATCHLINEMATCHLINE
P-105
MATCHLINE 8"øSAN4"ø
S
A
N 4"øSANFCO6"øSAN4"øSAN8"øSAN4"ø SAN
FCO
4"øSAN4"ø SAN6"øST(4000SF)6"ø ST (4000 SF)6"øST(4000SF)6"ø ST (5500 SF)6"øST(5500SF)8"øST(11000SF)8"ø ST (15000 SF)10"ø ST (19000 SF)
4"ø ST (2400 SF)
6"ø ST (3000 SF)
4"ø
S
T
(2
4
0
0
S
F)
6"ø ST (4800 SF)
6"ø ST (3000 SF)16"øST(82200SF)6"ø
S
T
(6
4
0
0
S
F)
16"ø ST (67200 SF)4"øSAN4"ø SAN
4"øSAN6"ø SAN6"ø SAN 8"ø SAN 8"ø SAN 8"ø SAN 4"øSAN4"øSAN6"
ø
S
T
(6
4
0
0
S
F
)
FCO
4"ø ST (4800 SF)
G
6"øF6"ø DS
(6400 SF)
6"ø DS
(6400 SF)6"øF3"øWTR3"ø WTR
3"ø WTR
3"ø WTR
4"ø SS 4"ø SS 4"ø SS
4"øSAN6"ø F
6"ø F
6"ø F
6"ø F
6"ø F
4"ø SS
6"ø DS
(4000 SF)
6"ø DS
(4000 SF)4"øSAN6"ø DS
(5500 SF)
6"ø SAN
8"ø SAN
8"ø SAN
8"ø SAN
8"ø SAN
3"øWTR6"øF6"ø F
6"ø F
6"ø F
3"ø WTR
3"ø WTR
3"ø WTR
6"ø DS
(3000 SF)
6"ø DS
(3000 SF)
6"ø DS
(4800 SF)
4"ø DS
(2400 SF)
4"ø DS
(2400 SF)12"øST(45200SF)16"ø ST (64200 SF)
4"ø SS
4"ø SS
4"ø SS
4"ø SS
16"ø ST (69600 SF)
16"ø ST (77400 SF)
6"ø F
6"ø F
6"ø F
6"ø F
6"ø F
6"ø F
6"ø F
8"øSAN1
P-501
16.6 17.6 18.6 19.6 20.66"øFTYP.
3"ø WTR 6"ø F
1
P-501 TYP.
1
P-501 TYP.
1
P-501TYP.
INV.828.94
829.72
16"ø ST (66000 SF)16"ø ST (72400 SF)
16"ø ST (78800 SF)
GCO
8"ø SAN
INV.828.07
INV.833.00
4"ø4"ø
1
SP-1
2"ø
2
33
STAIR 5A
019
VESTIBULE
012
ELEVATOR 5A
014
FCO FCO
16"ø ST (82200 SF)
18"ø ST (161000 SF)
INV.829.59
INV.828.93
FCO
FCO
FCO FCO
FCO
FCO
4
4"øSAN3"ø WTR
4"ø
6"ø DS
(5500 SF)
FD-1 FD-1
5
Sheet Name:
Proj. No.:
Date:
02/22/18 - GARAGE PERMIT
074904TheProsceniumDevelopmentCarmelDevelopmentII,LLC.GarageIntersectionofCarmelDr.andRangelineRd.Carmel,Indiana46032ARCHITECTURE ENGINEERING GEOSPATIAL
03/08/18
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
G
7635 Interactive Way
Suite 100
Indianapolis, IN
46278
317.299.7500
FAX: 317.291.5805
Issuances:
REV DESCRIPTION DATE
BIM360://74904-Proscenium-R18/74904Garage-MECHPLUMBR18.rvt2/27/20186:34:40PMGARAGE
UNDERGROUND
PLUMBING PLAN -
AREA C
P-103 1/8" = 1'-0"1 GARAGE UNDERGROUND PLAN - AREA C KEY PLAN
A
E F
B C
NORTH
D
DRAWING NOTES
1 PROVIDE STUB FOR FOOTER
DRAIN TILE PROVIDED BY THE
GENERAL CONTRACTOR.
2 SUMP PUMP DISCHARGE RISING
AT WALL. SEE P-200 SERIES
DRAWINGS FOR CONTINUATION
OF PIPING.
3 PROVIDE STUBS FOR FUTURE
BUILDING #4
4 PROVIDE CONNECTION AT
MANHOLE. VERIFY INVERT.
5 PROVIDE HEAT TRACING OF FIRE
PROTECTION AND DOMESTIC
WATER PIPING LOCATED IN
ENCLOSURE.
FINISH FLOOR ELEVATION = 833'- 8" (833.66')
0 Issued for Garage Permit 02/22/18