HomeMy WebLinkAboutA2.1-FLOOR-PLAN-Rev.0500PE DOOUMENT
THE DRAWINGS INDICATE THE GENERAL SCOPE
OF THE PROJECT IN TERMS OF PE516N CONCEPT.
AS SCOPE DOCUMENTS, THE DRAWINGS DO NOT
WGE55ARILY INDICATE OR DE5GRIBE ALL WORK
REQUIRED FOR FULL PERFORMANCE AND COMPLETION
OF THE PROJECT. THE GONTRAGTOR AND
SUBCONTRACTORS SHALL FURNISH ALL ITEMS FOR
WORK REGUIRED FOR THE PROPER EXECUTION AND
COMPLETION OF THE PROJECT.
GENERAL NOTES
A. ALL WORK SHALL COMPLY WITH ALL
APPLICABLE LOCAL, STATE, AND
FEDERAL CODES AND REGULATIONS.
B. ALL FINISHES SHALL COMPLY WITH
FLAME SPREAD AND SMOKE DEVELOPMENT
STANDARDS AS LISTED IN THE UNIFORM FIRE
CODE AND THE UNIFORM BUILDING CODE.
G. ALL DIMENSIONS ARE FROM FINISHED
FACE OF WALL TO FINISHED FACE OF
WALL OR FROM FIN15HED FACE OF WALL
TO FINISHED FACE OF MASONRY OR FROM
FINISHED FACE OF MASONRY TO FINISHED
FACE OF MASONRY, UNLESS OTHERWISE
NOTED. ALL MA50NRY DIMENSIONS ARE
NOMINAL.
D. VERIFY ALL EXISTIN6 CONDITIONS
PRIOR TO THE START OF CONSTRUCTION.
NOTIFY DE516NER OR ARCHITECT
IMMEDIATELY OF ANY DIMEN51ONAL
CONFLICTS OR CONFLICTS DUE TO
UNKNOWN CONDITIONS. WORK SHALL
NOT PROCEED UNTIL CONFLICTS ARE
RESOLVED.
E. EACH CONTRACTOR SHALL EXAMINE
ALL DRAWING SHEETS TO DETERMINE
FULL EXTENT OF RE5PON51BILITIE5
FOR EACH RESPECTIVE TRADE.
F. REVIEW ALL DRAWIN65
(ARCHITEGTURAL, PLUMBING,
ELECTRICAL, HVAC) CONCERNING
SLEEVES, OUTLETS, BOXE5, ANCHORS,
VENT5, OPENINGS, ETC. THAT MAY BE
REQUIRED. EACH RESPECTIVE TRADE
15 RESPONSIBLE FOR PROVIDING
AND INSTALLING THESE ITEMS.
6. ALL SUBGONTRAGTOR5 SHALL PROVIDE
SHOP DRAWINGS TO DE516HER
FOR REVIEW ON PRODUCTS OF WORK
PRIOR TO FABRICATION AS REQUESTED.
H. WHERE NIG = NOT IN CONTRACT, BY
OTHERS OR BY OWNER, THE 6.0. SHALL
GOOROINATE AND VERIFY ANY AND
ALL SPECIFIC REGdUIREMENT5 OF FRAMING,
BLOCKING, HOOK-UP, SERVICES, UTILITIES,
ETC. WITH THE OWNER.
I. O.G. TO TAPE, SPACKLE, AND SAND
SMOOTH ALL GYPSUM WALL CONSTRUCTION
AND PREPARE WALLS TO RECEIVE
FINISHES.
J. G.C. TO PROVIDE AND INSTALL ANY
i toAT lb Ob,
eATT mSAATIgI
H �� xsw amNm
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel C^�
�.- A'4",,___.._.\I
DATE: 03/27/19
FLOOR PLAN
PLAN NOTES
I. ALL DOORS TO BE NEW STANDARD SOLID CORE
WOOD DOORS WITH HOLLOW METAL FRAMES.
DOORS TO BE PRE -FINISHED STAIN. FRAMES TO
BE PAINTED. ALL DOORS TO HAVE
LEVER HANDLES WITH BEST (?) LOCKS AND
HARDWARE- NO SUBSTITUTES.
2. DOORS w51 AND 42 TO BE NEW METAL DOORS
AND FRAMES, PAINTED AND WITH PANIC
HARDWARE.
3. CONTRACTOR TO PROVIDE BLOCKING IN ALL
LOCATIONS WHERE 514ELVIN6, CABINETRY, OR
WORKSURFAGES ARE SHOWN.
4. EXTERIOR WINDOW BLINDS TO BE PROVIDED
FOR ALL EXTERIOR WINDOWS. ALL BLINDS TO BE
DETERMINED.
5. ALL EXPOSED CORNERS TO RECEIVE CLEAR
PLASTIC CORNER 61JAR05.
6. CONTRACTOR TO PROVIDE CLEAR CAULKING
AROUND ALL DOOR FRAMES (WOOD AND METAL)
AFTER DOOR FRAMES HAVE BEEN ADJUSTED
AND SET.
1. CONTRACTOR TO PROVIDE LEO SUPPORT FOR
ALL COUNTERTOPS NOT SUPPORTED BY BASE
CABINETS.
H. CONTRACTOR TO PROVIDE ALL CODE AND ADA
REOUIRED FIXTURES AND ACCE55ORIES FOR
RE5TROOM5 103, 132, 15b AND 156.
9. ANY INTERIOR 6LAZIN6 REQUIRED TO BE
�" LAMINATED SAFETY GLASS.
10. GONTRAGTOR TO PROVIDE SHOP DRAWIN65
FOR ALL CASEWORK FOR APPROVAL.
11. ALL NEW PLASTIC LAMINATE COUNTERTOPS TO
HAVE l}" RADIUS ON ALL EXPOSED 40 DE6REE
GORNER5.
12. CONTRACTOR TO PROVIDE CLEAR CAULKING
AROUND ALL COUNTERTOPS.
13. CONTRACTOR TO PROVIDE THE FOLLOWING
FOR DOOR FRAME SUPPORT, 20 5AU5E DOUBLE
5TUD ON EITHER 51DE OF DOOR FRAME; MINIMUM
OF 2' 20 6AU6E TRACK ON EITHER 51PE OF
DOOR FRAME; (2) LEAD ANCHORS ON TRACK ON
EITHER SIDE OF DOOR FRAME.
14. CONTRACTOR 15 REQUIRED TO TIE ALL LIGHT
FIXTURES TO BUILDING STRUCTURE.
15. ALL INTERIOR WALL CONSTRUCTION TO BE WALL
TYFE A EXCEPT AS NOTED.
16. SEE SITE PLAN FOR EXTERIOR WALK AND
RAMP LOCATIONS.
WALL TYPE B (RATED)
NO SCALE
FLOOR PLAN
KEYED NOTES
I. CONTRACTOR TO PROVIDE STANDARD
IT" X 19" 5TAINLE55 STEEL SIN6LE BOWL SINK.
2. CONTRACTOR TO PROVIDE STRUCTURAL
SUPPORT COLUMN.
3. CONTRACTOR TO PROVIDE 12" DEEP HEAVY
DUTY ADJJSTABLE SHELVING. CONTRACTOR
TO DETERMINE BEST ARRANGEMENT AND
SUPPORT. CONTRACTOR TO SUPPLY
STANDARDS AND BRACKETS AS REQUIRED.
4. CONTRACTOR TO PROVIDE STANDARD
DOUBLE BOWL STAINLESS STEEL SINK AND
TO HAVE 6ARBAc5E DISPOSAL.
S. LOCATION FOR MOP BASIN.
6. CONTRACTOR TO PROVIDE BLOCKING IN
WALL AT CEILING HEIGHT FOR WALL MOUNTED
TV. EXACT HEIGHT, SIZE, AND TYPE OF MOUNT
TO BE DETERMINED.
T. LOCATION FOR PHONE BOARD AND IT.
b. CONTRACTOR TO PROVIDE SHOWER BASIN
WITH EYEWASH AND EMERGENCY PULL
5TRIN6.
9. CONTRACTOR TO PROVIDE EXTRA
VENTILATION TO IT 156 AND LT BOX 114.
10. CONTRACTOR TO PROVIDE DRYWALL
EULKHEAD TO V-0' A.F.F.
11. LOCATION FOR FULL-SIZE REFRIGERATOR
WITH ICE MAKER BY TENANT. CONTRACTOR
TO PROVIDE ELECTRICAL AND WATER
SUPPLY.
12. LOCATION FOR COPIER BY TENANT.
13. CONTRACTOR TO PROVIDE 24" DEEP BASE
CABINET - PLI AT 34' A.F.F. WITH
PLASTIC, LAMINATE TOP - PL-.
14. CONTRACTOR TO PROVIDE SOLID SURFACE
COUNTER - SSI.
NALL LEGEND
NEW INSULATED WALL
�_______EXISTIN6 WALL CONSTRUCTION
TO BE REMOVED.
fEWI PARTIAL HE16HT PARTITION
NEW 6LAZED WALL
WALL TYPE G (NOT RATED)
NO SCALE
e
e
MOHS
115
MOHS
116
BILLERS (2)
163
MED OFFICE
165 r'
`Uu OFFICE
OFFICE V GAl
bl
IIV
PLAN NORTH
FLOOR PLAN
SGALE 1 8 =1-0'
001
w�l0�
F i v
a 0
® 1 ~
a °
j►a MGM O
T vMINI
®�
.
LN!J
Q
I
O O
L
� 0
�
v
MAPS LAB®
169
2
2
L---J
LJLJ
®w
e
SLIDES
E2
\-TRANSFORMER
VEST
101
e��HpP LFS�".
QP��e,E4NoeHFO�Y'P.^P
'f} 870146 i*
STATE OF j
0 14
(��"� "''•CIS'"'"
1
O
o
N
C1
a
AD
AD
LL
O
2 LL
L
LI
L
y o
LLI
O
m
00
r Q
Z
Z
�m
fl
Q
N
0
�w
F
rQ
u
LL
n/
1.�
m
SHEET NUMBER
A2"
OF_SHEETS