Loading...
HomeMy WebLinkAboutC2.1-UTILITY-PLAN-Rev.0TOPOGRAPHIC & BOUNDARY NOTE ALL EXISTING HORIZONTAL AND VERTICAL INFORMATION HAS BEEN SHOWN PER AN ALTA/NSPS LAND TITLE SURVEY PREPARED BY SEA GROUP, L-C. DATED 05/24/2018; THEREFORE, CIVIL SITE GROUP, INC. CANNOT BE HELD RESPONSIBLE IF ACTUAL HORIZONTAL AND VERTICAL DATA IS DIFFERENT FROM THAT SHOWN ON THESE PLANS. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS PRIOR TO COMMENCING WITH CONSTRUCTION. THESE DRAWINGS REFLECT ABOVE GROUND INDICATIONS OF EXISTING UTILITIES. THE SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED, ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM THE INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. EXISTING SANITARY MANHOLE T.0 =842.95 INV=834.95 (S-10" PVC) INV=834.95 (N-10" PVC) OWNER: SURVEYOR: DERMATOLOGY, INC. SEA GROUP, LLC. 3755 EAST 82nd STREET, STE. 75 494 ORACLE DRIVE INDIANAPOLIS, IN 46240 CARMEL, INDIANA 46032 ATTN: AMY SUMMERS (317) 844-3333 (317) 410-0056 . ENGINEER: ARCHITECT CIVIL SITE GROUP, INC. ENNIROSPACE, INC. 160 WEST CARMEL DRIVE ATTN: CANDACE BERGEF SUITE 240 645 BLOOR LANE CARMEL, INDIANA 46032 ZIOINSVILLE. IN 46077 (317) 810-1677 (317) 873-9950 CONNECT TO EXISTING 6" SAN. LAT. STUB (PR C.T.R.W.D. STANDARDS) 104 LF of DUSTING 6" SANITARY LATERAL (CONTRACTOR TO FIELD VERIFY DEPTH & LOCATION PRIOR TO COMMENCING WITH CONSTRUCTION) EXISTING SANITARY MANHOLE T.C=842.84 INV=836.34 (W-10" PVC) INV=836.34 (N-10" PVC) —sa—sw— SANITARY LATERAL NOTE REFER TO SHEET C10.1 FOR ALL SANITARY LATERAL INSTALLATION REQUIREMENTS, DETAILS, & SPECS. PER CLAY TOWNSHIP REGIONAL WASTE DISTRICT. NOTE REFER TO ARCHITECTURAL & FOUNDATION PLANS FOR ALL BUILDING DIMENSIONS. A 1 wnowwhaf9 below. Call before you dig. UTILITY LOCATE NOTE INDIANA 811 FAILED TO LOCATE ALL EXISTING UTILITIES ON AND/OR SURROUNDING THE SUBJECT SITE; THEREFORE, CONTRACTOR IS RESPONSIBLE TO LOCATE AND FIELD VERIFY ANY EXISTING UTILITIES BEFORE COMMENCING WITH CONSTRUCTION. CIVIL SITF GROUP. INC. CANNOT RF HFI D RESPONSIBLE RELEASED FOR CONSTRUCTION INoN Subject to compliance with all regulations of State and I ocal Cnni e City of Camel ((�� yVT�tanrklaA�L DATE: \ 03/27/19 I UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPER'S RESPONSIBILITY TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OR THE PROPOSED RIGHT-OF-WAY LINE. LOSS -HATCH C `, FIRE HYDRANT M Mk PROPOSED BUILDING 11,851 S.F. (GROSS) / / I I I 1 12 CONTRACTOR NOTE NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. LAKEFRONT COURT CONNECT TO NEW 2" PL GAS MAIN FUTURE GAS MAIN TO BE EXTENDED BY (T.B.D. BY VECTREN) VECTREN /�F31MO G E / \15ou& G --- 9: u �w�ELECTRIC Y)SERVICE (T.B.D. BY DUKE ENERG ; J \. / 6 UI GAS SERVICE UNE / (T.B.D. BY VECTRR) / N U 4/ 2.43 ACRES F.F.E. = 845.70 i o `� GAS SERVICE METER \ 713 L.F. 6" SAN. LAT. (SDR 26 PVC \ V ryA. I (T.B.D. BY VECTREN) rr e 1 04% MIN. W/TRACR WIRE REQ'D) \ Vr INF 2° DOMESTIC WATER SERVICE I' �I W/CURB STOP VALVE \ lizl `\ W \ 9 F5 `\ ELEC. CT CABINET (T.B.D. BY a N \ I u o I CONTRACTOR PER DUKE ENERGY SPECS.) \ I z I \\ SECONDARY ELECTRIC SERVICE IOn I \\\\ NEW TRANSFORMER PER DUKE j ENERGY SPECS - I �� a \\\ "PRIMARY SERVICE ROUTE TO BE Na M \\ DETERMINED BY DUKE ENERGY rt' I I I --------------------------------------------------- ----------------------- 1------------------------------------------------------ ------------------------- oua � �_ —{n—Fm—m mn srg— — a16o_py_—m—m—m—m m—m—m m m tO1—� 35' REGULATED DRAIN EASEMENT I �30' UTILITY EASEMENT &REAR YARD SETBACK gam, G — G — G — G — 2" WATER SERVICE ENE TAP W/ CURB STOP VALVE & FULL CIRCLE CLAMP PER CARMEL UTILITIES STD CW4-1 REVISION RECORD IREVI DATE I DESCRIPTION DES BY APR BY 1 107/27/181 REVISIONS PER T.A.C. COMMENTS LAG I FAG LEGEND: PROPERTY BOUNDARY RIGHT—OF—WAY — EASEMENT 0 NORTH r PROPOSED CONCRETE zo 0 10 20 PROPOSED STORM SEWER ( IN FEET ) Q PROPOSED STORM STRUCTURE 1 inch = 20% UTILITY CROSSING (EXISTING UTILITY DEPTH UX UNKNOWN / CONTRACTOR TO FIELD VERIFY PRIOR TO COMMENCING WITH CONSTRUCTION) ------------ ROOF DRAIN WTR EXISTING WATER LINE COM EXISTING COMMUNICATION LINE FBOP EXISTING FIBER OPTIC LINE UGE EXISTING UNDERGROUND ELECTRIC LINE STM EXISTING STORM SEWER SAN EXISTING STORM SEWER E E PROPOSED ELECTRIC SERVICE T T PROPOSED TELECOM SERVICE — W — W — PROPOSED WATER SERVICE — G — G — PROPOSED GAS SERVICE PROPOSED SANITARY LATERAL WITH 0`V CLEANOUT (SEE DETAIL 17/C10.1) SPLIT 1" INTERIOR SET METER ASSEMBLIES PER CARMEL UTIUTIES STDS. / OBACKFLOW PREVENTER TO BE FIRST CONNECTION DOWNSTREAM OF METER TREE (CONTRACTOR TO VERIFY ADEQUATE PRESSURE & FLOW PRIOR TO COMMENCING WITH CONSTRUCTION) UX UTILITY CROSSING CC CONCRETE CRADLE REQUIRED NOTE UTILITY NOTES 1. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS 18" OF VERTICAL SERARATION PERTAINING TO THEIR PHASE OF WORK. IT SHALL ALSO BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF MUST BE MAINTAINED FOR ALL THE VARIOUS UTILITIES FOR PROPER STAKE LOCATIONS FOR UTILITY CROSSINGS. EACH UTILITY BEFORE WORK IS STARTED. THE CONTRACTOR SHALL NOTIFY IN WRITING THE OWNER OR THE ENGINEER OF ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN THE FIELD BEFORE WORK IS STARTED OR RESUMED. SITE LIGHTING NOTE 2. STANDARD LOCALGOVERNING HALLAP LYTFORALLSANI SEWERS. AND WATER MAINS. SITE LIGHTING IS NOT SHOWN ON THESE PLANS. 2-1Y" CONDUITS (SITE UGFIPNG&SECURITY) 3. ANY PART OF THE SANITARY OR STORM SEWER TRENCHES REQUIRED TO AIL SITE hGI¶NG )CATIONSL. RUNNING UNDER PAVED AREAS TO BE BACKFILLED WITH GRANULAR MATERIAL, 4. ALL WATER SERVICE I FIRE LINES ARE REQUIRED TO HAVE A 54" IRRIGATION /A NOTE MINIMUM COVER OVER TOP OF PIPE. ALL WATEWSANITARY LINE CROSSINGS MUST MAINTAIN 18' VERTICAL SEPARATION BETWEEN OUTSIDE OF PIPES PER INDIANA STATE DEPARTMENT OF HEALTH SITE IRRIGATION IS NOT SHOWN ON THESE PLANS. IF SITE IRRIGATION IS REQUIRED CONTRACTOR SHALL WORK WIN THE 5. STERILIZATION OF WATER MAIN SHALL BE IN ACCORDANCE LOCAL WATER UTILITY TO DETERMINE THE REQUIREMENTS & STATE BOARD OF HEALTH REQUIREMENTS. WITHLOCATION FOR THE IRRIGATION METER & SITE IRRIGATION SYSTEM. PP (APPLIES TO COMMERCIAL ONLY) NO IRRIGATION SYSTEM SHALL BE INSTALLED WCITY THE PUBLIC S BOARD OF —WAY UNLESS APPROVAL FROM THE CITY OF G2EENWOW s. CONTRACTOR RESPONSIBLE INSTALLALLUNDERGROUND BOARD OF PUBLIC WORKS AND SAFETY S OBTAINED. CONCUR PER UNITY COMPANY'S SPECIFICATIONS. Y' 7. CONTRACTOR RESPONSIBLE FOR RESTORATION TO ALL AREAS VALVE NOTE CITY OF DDURING CITY OFEOBLESVILE STANDARDS ORREFERTOTHE URI GC STANDARDSFORRESTORATION REQ'S. AFFUTILITY 8. CONTRACTOR TO LOCATE ALL EXISTING UTILITIES AT ANY ALL UTILITY VALVES AFFECTED BY CONSTRUCTION SHALL BE PROPOSED CROSSING AND PROVIDE EXISTING TOP OF PIPE ADJUSTED TO FINAL GRADE AS NEEDED TO BE FLUSH WITH ELEVATIONS WITHIN 10 DAYS OF NOTICETO PROCEED. FINISHED PAVEMENT, SIDEWALK OR LANDSCAPE AREA. PROVIDE CONCRETE CRADLE AS REQUIRED FOR ANY VERTIOAI SEPARATION LESS THAN 18 INCHES. UTILITY CONTACTS Natural Gas: Vectren Energy Joanie Clark (317) 776-5532 jlclark@Vectren.com Sanitary Sewer: Clay Township Regional Waste District Ryan Hartman 10701 N. College Avenue, Ste. A Indianapolis, IN 46280 (317) 844-9200 ext. 203 Drainage: Carmel Engineering Alex Jordan or John Thomas 1 Civic Square Carmel, IN 46032 (317) 571-2441 gduncan@carmel.in.gov Telephone: AT&T Steve Krebs (317)252-4275 SK4986@att.com Fire Service: Office of Fire Chief, Fire Station #1 David Haboush Two Civic Square Carmel, IN 46032 (317) 571-2600 dhaboush@carmel.in.gov Streets: Carmel Street Department Dave Klingensmith 3400 West 131st Street Westfield, IN 46074 (317) 733-2001 CATV: Brighthouse Networks Jason Kirkman (317) 632-9077 x291 jason.kirkman@mybrighthouse.com Water: Carmel City Utilities John Duffy 760 Third Avenue SW Carmel, IN 46032 (317) 632-9077 Electric: Duke Energy Shirley Hunter 16475 Southpark Dr. Westfield, IN 46074 (317) 896-6721 shirley.hunter@duke-energy,com Ci CL 1 W O O cl Cn Z �D I® W E-1 Z < i-I �No 00 C) 0i d c _ QwQ E O LO Ln _ova CO) o°) 3 h v = O M 0 V� a �� �•�G\STEq� 7'�P i NO - • PE10403858 : AL .o STATE OF DATE: 07/20/2018 DWN BY: KPB CHKD. BY: EAG SCALE: 1" = 20' DATE: 07 20 18 N m O �z U0 la's O�/�� (zu¢(�� W V �— _J U)O I—� x O O 0 Ln N L` PROJECT INIJMHER T)ER.001 DRAWING NUMBER C2.1 SHEET 4 OF 15