Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M000-MECHANICAL-SYMBOLS-Rev.0
ABBREVIATIONS AND TERMS AIC AIRCONDITIONING EWT ENTERING WATER TEMPERATURE OA OUTSIDE AIR ACC AIR COOLED CONDITIONER EX EXHAUST OAT OUTSIDE AIR TEMPERATURE ACLU AIR COOLED CONDESNING UNIT F FURNACE DRIP OPPOSED BLADE DAMPER AD ACCESS DOOR F&T FLOAT AND THERMOSTATIC STEAM TRAP OD OUTSIDE DIAMETER, OVERFLOW DRAIN ARE ABOVE FINISHED FLOOR AGO FLOOR CLEANOUT OFICI OWNER FURNISHEDICONTRACTOR ARMS AIR FLOW MEASURING STATION FCU FAN COIL UNIT INSTALLED AGA AMERICAN GAS ASSOCIATION FD FLOOR DRAIN, FIRE DAMPER OSD OPEN SITE DRAIN AHU AIR HANDLING UNIT ADC ARE DEPARTMENT CONNECT] ON OZ OUNCE AL ALUMINUM HE HREEXTINGUISHER P PUMP ANSI AMERICAN NATIONAL STANDARDS INSTITUTE RHO HREHOSECABINET RED PARALLEL BLADE DAMPER AO ANALOG OUTPUT FLA FULL LOAD AMPS PC PLUMBI NG CONTRACTOR AP ACCESS PANEL FLR FLOOR PD PRESSURE DROP APD AIR PRESSURE DROP (IN. WC,) AM FACTORY MANUAL PH PHASE ARCH ARCHITECT FOV FUEL OIL VENT PN POST INDICATOR VALVE ARI AIR CONDITI ONING AND HEAR GERAl1 ON FPC ARE PROTECT] ON CONTRACTOR RPM PARTS PER MILLION INSTITUTE ARM FEET PER MINUTE PRV PRESSURE REDUCING VALVE ARV AIR RELIEF VALVE FPVAV FAN POWERED VAV UNIT PSI POUNDS PER SQUARE INCH AS AIRSEPARATOR FS FLOOR SINK PSIA POUNDS PER SQUARE INCH ABSOLUTE ASHRAE AMERICAN SOCIETY OF HEATING, FSD COMBINATION FIREISMOKE DAMPER PSIS POUNDS PER SQUARE INCH GAUGE REFRIGERATING, AND AIR CONDITIONING FT FOOT, FEET PTAC PACKAGED TERMINAL AIR CONDITIONER ENGINEERS FTR FINNED TUBE RADIATION PVC POLYVINYL CHLORIDE ASME AMERICAN SOCIETY OF MECHANICAL G NATURAL GAS R12 REFRIGERANT IT Z 22, ETC.) ENGINEERS GA GAGE OR GAUGE RA RETURN AIR ASPE AMERICAN SOCIETY OF PLUMBING GAL GALLON RAT RETURN AIR TEMPERATURE ENGINEERS GC GENERAL CONTRACTOR RD ROOF DRAIN ASTM AMERICAN SOCIETY FORTESTING AND GIV GRAVITY INTAKE VENTILATOR REV REVOLUTIONS MATERIALS GPD GALLONS PER DAY RF RETURN FAN ATM ATMOSPHERE GPH GALLONS PER HOUR RH RELATIVE HUMIDITY AWWA AMERICAN WATER WORKS ASSOCIATION GPM GALLONS PER MINUTE RM ROOM BD BUTTERFLYDAMPER GRV GRAVITY RELIEF VENTILATOR RP RADIANT PANEL BDD BACKDRAFTDAMPER GT GREASETRAP RPM REVOLUTIONS PER MINUTE BE BOTTOM ELEVATION HB HOSE BIBB RES REVOLUTIONS PER SECOND BHP BRAKEHORSEPOWER HD HEAD(FT) RTU ROOF TOP UNIT BLDG BUILDING HHWP HEATING HOT WATER RUMP RV RELIEF VALVE, ROOF VENT BOD BOTTOM OF DUCT HE HORSEPOWER, HEAT PUMP SA SUPPLY AIR BOP BOTTOM OF PIPING HR HOUR(S) SO SMOKE DAMPER ST BATHTUB HX HEAT EXCHANGER SEER SEASONAL ENERGY EFFICIENCY RATING CA COMPRESSED AIR He HERTZ SF SQUARE FOOT, SUPPLY FAN, SAFETY CB CATCH BASIN IS INVERTED BUCKET STEAM TRAP FACTOR OF CEILING FAN ID INSIDEDIAMTER SH SHOWER CFM CUBIC FEET PER MINUTE IE INVERT ELEVATION SK SINK CH CHILLER IN INCH, INCHES SMACNA SHEET METAL AND AIR CONDITIONING CHWP CHILLED WATER PUMP INT INTERIOR CONTRACTORS NATIONAL ASSOCIATION Cl CASTIRON INV INVERT SP STATIC PRESSURE CO CLEANOUT IRS INTERNATIONAL PIPE STANDARD SPEC SPECIFICATION COMER COMPRESSOR IW INDIRECTWASTE SO SQUARE COND CONDENSER ITC KITCHEN EQUIPMENT CONTRACTOR SRV SAFETY RELIEF VALVE CONV CONVECTOR kW KILOWATT SS SERVICE SINK, STAINLESS STEEL CP CONDENSATEPUMP LAT LEAVING AIR TEMPERATURE STD STANDARD CPVC CHLORINATED POLYVINYL CHLORIDE LAV LAVATORY SV STEAM VENT CT COOLING TOWER LBS POUNDS TOO TEMPERATURE CONTROL CONTRACTOR CU CONDENSING UNIT LP LIQUID PETROLEUM TE TOP ELEVATION CUH CABINET UNIT HEATER LWT LEAVING WATER TEMPERATURE TEMP TEMPERATURE CUV CLASSROOM UNIT VENTILATOR MA MIXED AIR TF TRANSFER FAN CV CONTROL VALVE MAT MIXED AIR TEMPERATURE TMV THERMOSTAIIC MIXING VALVE CWP CONDENSER WATER PUMP MAX MAXIMUM TS TAMPERSIMTCH DB DRYBULB ME MOPBASIN TER TOTAL STATIC PRESSURE (IN. WC.) DC DIRECTCURRENT MEH THOUSAND BTUH TXV THERMAL EXPANSION VALVE OF DRINKING FOUNTAIN MC MECHANICAL CONTRACTOR TYP TYPICAL DH DUCTHEATER MCA MINIMUM CIRCUIT AMPS UH UNITHEATER DI DIGITAL INPUT MCC MOTOR CONTROL CENTER UR URINAL DIN DOWN MD MOTORIZED DAMPER W UNITVENTILATOR DO DIGITAL OUTPUT MAR MANUFACTURER V VOLTS, VENT DS DOWNSPOUT MIN MANHOLE VAC VACUUM DWG DRAWING MIN MINIMUM VAV VARIABLE AIR VOLUME DWH DOMESTIC WATER HEATER MISC MISCELLANEOUS VB VACUUM BREAKER DWV DRAIN, WASTE, B VENT MS MOP SINK VD VOLUME DAMPER DX DIRECT EXPANSION MID MOUNTED VEL VELOCITY EA EXHAUST AIR MV MANUALVENT VERT VERTICAL EAT ENTERING AIR TEMPERATURE N NITROGEN VF VENTILATION FAN EC ELECTRICAL CONTRACTOR NA NOT APPLICABLE VFD VARIABLE FREQUENCY DRIVE ECO EXTERIOR CLEANOUT NO NOSE CRITERIA, NORMALLY CLOSED VTAC VERTICAL TERMINAL AIR CONDITIONER EER ENERGY EFFICIENCY RATIO NEC NATIONAL ELECTRIC CODE VTR VENTTHRQUGH ROOF EF EXHAUST FAN NEC NATIONAL FIRE CODE WV VERTICAL UNIT VENTILATOR EFF EFFICIENCY NFPA NATI ONAL FIRE PROTECT ON ASSOCIATION W WASTE, WATT EL ELEVATION NFWH NON -FREEZE WALL HYDRANT WI NTH EOM END OF MAIN DRIP NIC NOT IN CONTRACT NO WTHOUT ESH EMERGENCYSHOWER NO NORMALLY OPEN, NITROUS OXIDE WB WET BULB ESP EXTERNAL STATIC PRESSURE (IN.WC) NOM NOMINAL WC WATER CLOSET, WATER COLUMN ET EXPANSION TANK NEW NONPOTABLEWATER WCO WALLCLEANOUT EW EMERGENCY EYE WASH Ni NOT TO SCALE NH WALL HYDRANT ENO ELECTRIC WATER COOLER 0 OXYGEN WPD WATER PRESSURE DROP (FT. HD) WSHP WATER SOURCE HEAT PUMP RELEASED FOR CONSTRUCTION Subject to compliance with all regulalions of State and Local Codes City Gf Camel �N�1��T1G,N DATE: 03/27/19 REFERENCE SYMBOLS f� CONNECT] ON TO EXISTING INDICATOR PLAN NOTE INDICATOR DEMOLITION NOTE INDICATOR YQDRAWING REVISION INDICATOR X XXX-X �EQUIPMENTNO. EQUIPMENT INDICATOR YPE DETAIL NO. SHEET NO DETAIL INDICATOR XIXXXX AIJI SHEET NO. SECTION INDICATOR SECTION LETTER ELEVATION INDICATOR �SHEETNO. ELEVATION LETTER PIPING IDENTITY SYMBOLS ___0 PIPE PIPE ELBOW UP FLOW SWITCH D PIPEELBOWDOWN BALL VALVE I1i C PIPE TEE DOWN Dd GATEVALVE ----0— PIPE TEE UP --VQi AUTOMATIC FLOW VALVE 3 PIPE CAP CALIBRATED FLOW VALVE PIPE CONTINUES, SHOWN ELSEWHERE -181— GLOBE VALVE --S ir PIPE CONTINUES, VISUAL BREAK &— BUTTERFLY VALVE PITCH DIRECTION ARROW PLUG VALVE R`R t FLOW DIRECTION ARROW r�)— CHECK VALVE — — — PRESSUREIEMPERATURE PORT t5i PRESSURE REDUCING VALVE 4 AUTOMATIC AIR VENT ---&— 2-WAY ELECTRIC CONTROL VALVE * MANUAL AIR VENT — — — 4T#— 3-WAY ELECTRIC CONTROL VALVE PIPE ANCHOR ANGLE GATE VALVE = PIPE GUIDE All— PRESSURE RELIEF VALVE ---E:3— EXPANSION COMPENSATOR STRAINER --47F-- PIPEREDUCER STRAINER WITH CAPPED SLOWDOWN --iDg+— CIF— PIPEUNION —04q4_D REDUCED PRESSURE BACKFLOW PREVENTER ® WATER METER DOUBLE CHECK BACKFLOW PREVENTER ^• GAS METER ---rZr� DUAL CHECK VALVE EZa— FLEXIBLE CONNECTOR �l HORIZONTAL CLEANOUT n J-titi PIPE DOWN TO HOSE BIBB JI THERMOMETER INLINEPUMP WATER HAMMER ARRESTOR PRESSURE GAUGE WITH GAUGE CDC ® FLOOR DRAIN F&T STEAM TRAP(TYPE INDICATED) Eq FLOOR SINK PRESSURE SWITCH GENERAL LINETYPE DESIGNATORS EXISTING TO REMAIN — — — — EXISTING TO BE REMOVED NEW PLUMBING PIPING LEGEND — COLD WATER (CW) — — HOT WATER(HW) — — — HOT WATER RETURN(HWR) 14OF NN 14TF HOT WATER 14OFNNR 14TF HOT WATER RETURN Sw SOFTENED WATER DI DIONIZED WATER RG REVERSE OSMOSIS WATER SAN SANITARY —SAN— SANITARY (BELOW FLOOR) FSAN FORCE MAIN (SANITARY) GSAN GREASE SANITARY —GSAN— GREASE SANITARY (BELOW FLOOR) — — — — — — — — — — — — — — — — — — — — — — — — — SANITARY VENT iW INDIRECT WASTE ST STORM DRAIN —ST — STORM DRAIN (BELOW FLOOR) NGFREESURE) NATURAL GAS \P LIQUID PETROLEUM CA COMPRESSED AIR A VACUUM MECHANICAL PIPING LEGEND COPS CHILLED WATER SUPPLY CWR CHILLED WATER RETURN HAS HEATING WATER SUPPLY NWR HEATING WATER RETURN on DUAL TEMPERATURE SUPPLY oTR DUAL TEMPERATURE RETURN CS CONDENSOR WATER SUPPLY CR CONDENSER WATER RETURN XPRESWRE) STEAM scpsessuse) STEAMCONDENSATE Ro REFRIGERANT DISCHARGE (HOT GAS) RS REFRIGERANT SUCTION R\ REFRIGERANT LIQUID Co CONDENSATE DRAIN PC PUMPED CONDENSATE — — — — — — — — — — — CONTROL MINING DUCTWORK IDENTITY SYMBOLS 24x72 RECTANGULAR DUCTWORK DEIGNATION IN INCHES, PRESSURE SENSOR NTH ACCESS DOOR. FIRST DIMENSION IS SIDE SHOWN. 24"Pl ROUND SPIRAL DUCTWORK DESIGNATION IN TEMPERATURE SENSOR WTH ACCESS DOOR INCHES. �--� 24x72 FLAT OVAL DUCTWORK DESIGNATI ON IN INCHES, SMOKE DETECTOR WITH ACCESS DOOR. FIRST DIMENSION IS SIDE SHOWN. 1q�� DUCTWORKRISEUPPLY AIR, OUTSIDE AIR FLEXIBLEDUCTWORI(CONNECTIIXJ. �� ROUND SPIRAL SUPPLY AIR, OUTSIDE AIR DUCTWORK LINING OR DOUBLE WALL DUCTWORK, DUCTWORK RISE. II�� DESIGNATION SHOWN IS FREE AREA. FLAT OVAL SUPPLY AIR, OUTSIDE AIR DUCTWORK 4E BEVELED FITTING FOR RECTANGULARTO RISE RECTANGULAR DUCTWORK RECTANGULAR SUPPLY AIR, OUTSIDE AIR CONICAL FITTING FOR ROUND OR FLAT OVAL TO DUCTWORK DROP. RECTANGULAR DUCTWORK ROUND SPIRAL SUPPLY AIR, OUTSIDE AIR CONICAL FITTING FOR ROUND OR FLAT OVAL TO DUCTWORK DROP. ROUND OR FLAT OVAL DUCTWORK FLAT OVAL SUPPLY AIR, OUTSIDE AIR 450 LATERAL FITTING FOR ROUND OR FLAT OVAL TO DUCTWORK DROP. 1�,�� ROUND OR FLAT OVAL DUCTWORK R y DUCTWORK RISE IN DIRECT] ON OF FLOW. { I MITERED DUCTWORK ELBOW. MITERED DUCTWORK ELBOW WITH TURNING DUCTWORK DROP IN DIRECTION OF FLOW. VANES. 450 VOLUME DAMPER (CENTEIUNE 1SW). ELBOW (CENTERLINE 1.SxW). ACCESS DOOR ® CEILING PANEL SUPPLY AIR DIFFUSER MOTORIZED DAMPER WITH ACCESS DOOR. ROUND SUPPLY AIR DIFFUSER I FIRE DAMPER NTH ACCESS DOOR ® RECTANGULAR SUPPLY AIR REGISTER. SMOKE DAMPER WITH ACCESS DOOR. RETURN, EXHAUST, OR TRANSFER GRILLE. BACK DRAFT DAMPER NTH ACCESS DOOR O THERMOSTAT. AIRFLOW MEASURING STATION WTH ACCESS RO HUMIDISTAT. DOOR. FIRE AND SMOKE DAMPER WITH ACCESS DOOR. © CARBON DIOXIDE SENSOR. GENERALNOTES A ALL WORK SHALL BE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF THE TRADE, AND SHALL CONFORM WITH ALL FEDERAL, STATE, AND LOCAL CODES AND STANDARDS. THE SAME ARE MADE A PART OF THESE CONTRACT DOCUMENTS AS IF REPEATED HEREIN. B. CONTRACT DOCUMENTS CONSIST OF BOTH THE PROJECT MANUAL AND DRAWINGS, AND BOTH ARE INTENDED TO BE COMPLEMENTARY. ANYTHING APPEARING ON EITHER MUST BE EXECUTED THE SAME AS IF SHOWN ON BOTH. G THE CONTRACTOR SHALL INCLUDE IN BID PROPOSAL ALL COSTS REQUIRED TO COMPLETELY AND PROPERLY INSTALL ALL WORK REQUIRED FOR THE PROJECT, AND SHALL EXAMINE THE SCOPE OF WORK OF OTHER TRADES PRIOR TO SUBMITTING A BID PROPOSAL. D. CONSTRUCT] ON DOCUMENTS SHALL BE FOLLOWED AS CLOSELY AS POSSIBLE, HOWEVER SYSTEMS HAVE BEEN SHOWN DIAGRAMATICALLY AND IN SOME CASES, ENLARGED FOR CLARITY. ANY OFFSETS, ADDITIONAL FITTINGS, ANDIOR APPURTENANCES REQUIRED TO PROVIDE A COMPLETE AND COORDINATED SYSTEM SHALL BE BORNE BY THE CONTRACTOR. E THE ENGINEERING DRAWINGS ARE OF EQUAL IMPORTANCE WITH THE ARCHITECTURAL DRAWINGS IN DEFINING THE WORK OF THE CONTRACT DOCUMENTS. ITSHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK NTH THE ARCHITECTURAL DRAWINGS BEFORE THE INSTALLATION OF ENGINEERING WORK. SHOULD THERE BE A DISCREPANCY BETWEEN THE ARCHITECTURAL DRAWINGS AND THE ENGINEERING DRAWINGS THAT WOULD CAUSE AN AWKWARD OR IMPROPER INSTALLATION, THE DISCREPANCY SHALL BE BROUGHT TO THE ARCHITECTSENGINEERS ATTENTION FORCLARIFICATTON PRIORTO INSTALLATION OF SAID WORK ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BYTHE CONTRACTOR AT HIS EXPENSE AND AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECTIENGINEER. F. DO NOT SCALE THE DRAWINGS. THE DRAWINGS ARE NOT NECESSARILY TO SCALE. THE CONTRACTORSHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE PRIOR TO THE START OF CONSTRUCTION. IF DISCREPANCIES ARE FOUND, THE ARCHITECTIENGINEER SHALL BE NOTIFIED FOR CLARIFICATION BEFORE COMMENCING THE WORK. EXPLICIT DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALE. G. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BIDDING OR BEGINNING WORK ON THIS PROJECT. H. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE SHOWN. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, CONSULT THE ARCHITECTIENGINEER BEFORE PROCEEDING WITH THE WORK. I. ANY DETAILS, SYSTEMS ANDIOR MATERIALS WHICH ARE PROPOSED TO BE CHANGED MUST FIRST BE REVIEWED BY THE OWNER AND ARCHITECTIENGINEER PRIOR TO THE PREPARATION OF SHOP DRAWINGS. J. REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS AND TEMPLATE DRAWINGS FOR ALL MECHANICAL EQUIPMENT SUPPORTS, BOLT SETTING TEMPLATES, ISOLATORS, SPRING ISOLATION, ETC, NOT SHOWN ON THE DRAWINGS. K. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF CEILING MOUNTED MATERIALS INCLUDING ALL DIFFUSERS, GRILLES, AND REGISTERS. L. CONTRACTOR SHALL CLOSE ALL UNUSED OPENINGS IN EXISTING DUCTWORK. M. ALL DUCTWORK DESIGNATIONS REFER TO NET FREE AREA INSIDE THE DUCTWORK N. VOLUME DAMPERS SHALL BE LOCATED AT BRANCH CONNECTION TO THE MAIN. 0 A MAXIMUM OF SIX FEET OF FLEXIBLE DUCTWORK MAY BE USED AT ALL SUPPLY DIFFUSERS. BRANCH DUCTWORK TO DIFFUSER SHALL BE SAME SIZE AS DIFFUSER INLET UNLESS SPECIFICALLY LABELED OTHERWISE. REFER TO DIFFUSER SCHEDULE FOR INLET SIZES. AVOID SHARP BENDS IN FLEXIBLE DUCTWORK WHICH MAY P BRANCH DUCTWORK TO TERMINAL UNITS SHALL BE SAME SIZE AS TERMINAL UNIT INLET UNLESS SPECIFICALLY LABELED OTHERWISE. REFER TO TERMINAL UNIT SCHEDULE FOR INLET SIZES. NOT ALL NOTES, DESIGNATORS, SYMBOLS, OR ABBREVIATIONS MAY APPLY TO THIS PROJECT. CERTIFIED BY: 0 I1 IIF�C �T i pfO\STFq No. %PE10809451 STATE Cf �` T1,10NAp11"`j U Z Y d 0 Z a 0 / Z Z = W LU LU O ~ 06 U J W H w LU O Z a O WOU Z Z W O W < a W U Y J LL O L0 V N r � J W 0 REVISION: MARK I DATE I DESCRIPTION BRS PROJECT NUMBER 2018002 ISSUE DATE DRAWN BY CHECKED BY 2018.09.28 RCH JRF MECHANICAL SYMBOLS SHEET NUMBER M000