Loading...
HomeMy WebLinkAbout18110110 ElectricalCOMcheck Software Version 4.0.8.2 Interior Lighting Compliance Certificate Project Title: 2012 IECC Project Type:Alteration Construction Site: 10325 N. MICHIGAN RD. CARMEL, IN 46032 Owner/Agent: Chuy's 1623 Toomey Road Austin, TX 75067 514.473.2783 Designer/Contractor: Dialectic, Inc 310 W 20th St Suite 200 Kansas City, MO 64108 816.997.9601 Project Information Energy Code: Chuy's Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Dinning (Common Space Types:Family dining area)4950 1.40 6930 6930Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Dinning ( Common Space Types:Family dining area 4950 sq.ft.) LED 1: A3: Recessed: Other:1 9 26 234 LED 1 copy 1: A5: Recessed: Other:1 57 10 570 Track lighting 1: A6: TRACK: Wattage based on circuit breaker capacity (15 amps x 120 volts)0 0 1800 1800 LED 4: B: Linear: Other:1 4 51 204 LED 5: CB: Pendant: Other:1 1 30 30 LED 6: CC: Pendant: Other:1 4 30 120 LED 7: F: Fisher: Other:1 16 10 160 LED 8: J: Recessed: Other:1 14 27 378 LED 9: M/MX: Linear: Other:1 20 56 1120 LED 11: P1: Pendant: Other:1 21 10 210 LED 11 copy 1: P2: Pendant: Other:1 10 10 100 LED 12: P3: Pendant: Other:1 10 40 400 LED 16: Z: Surface: Other:1 1 75 75 5401Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2012 IECC requirements in COMcheck Version 4.0.8.2 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Interior Lighting PASSES Project Title: Data filename: Chuy's Y:\_Projects\Active\2018\01201828.31\01201828.31.Calcs and Support\182831 COMCHECK.cck 10/22/18Report date: 81 ofPage Name - Title Signature Date Project Title: Data filename: Chuy's Y:\_Projects\Active\2018\01201828.31\01201828.31.Calcs and Support\182831 COMCHECK.cck 10/22/18Report date: 82 ofPage Jeremy Marjan - EE 10/22/18 COMcheck Software Version 4.0.8.2 Exterior Lighting Compliance Certificate Project Title: 2012 IECC Project Type:Alteration Construction Site: 10325 N. MICHIGAN RD. CARMEL, IN 46032 Owner/Agent: Chuy's 1623 Toomey Road Austin, TX 75067 514.473.2783 Designer/Contractor: Dialectic, Inc 310 W 20th St Suite 200 Kansas City, MO 64108 816.997.9601 Project Information Energy Code: Chuy's 2 (Neighborhood business district)Exterior Lighting Zone Allowed Exterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B X C) Illuminated area of facade wall or surface 2232 ft2 0.1 No 223 Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 0 223 600 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Illuminated area of facade wall or surface (2232 ft2): Non-tradable Wattage LED 1: L1: Wall mount fixture: Other:1 24 13 312 0Total Tradable Proposed Watts = Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 2012 IECC requirements in COMcheck Version 4.0.8.2 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Exterior Lighting PASSES Project Title: Data filename: Chuy's Y:\_Projects\Active\2018\01201828.31\01201828.31.Calcs and Support\182831 COMCHECK.cck 10/22/18Report date: 83 ofPage Jeremy Marjan-EE 10/22/18 Inspection Checklist Requirements: 100.0% were addressed directly in the COMcheck software COMcheck Software Version 4.0.8.2 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2012 IECC Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Requirement will be met. C103.2 [PR8]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Chuy's Y:\_Projects\Active\2018\01201828.31\01201828.31.Calcs and Support\182831 COMCHECK.cck 10/22/18Report date: 84 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.2.2. 1 [EL22]2 Automatic controls to shut off all building lighting installed in all buildings. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.1. 1 [EL23]2 Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.1. 2 [EL15]1 Lighting controls installed to uniformly reduce the lighting load by at least 50%. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.2. 3 [EL16]2 Daylight zones provided with individual controls that control the lights independent of general area lighting. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.3 [EL17]3 Sleeping units have at least one master switch at the main entry door that controls wired luminaires and switched receptacles. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.2.2. 2 [EL18]1 Occupancy sensors installed in required spaces. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.2. 3 [EL20]1 Primary sidelighted areas are equipped with required lighting controls. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.2. 3 [EL21]1 Enclosed spaces with daylight area under skylights and rooftop monitors are equipped with required lighting controls. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.2.4 [EL25]2 Automatic lighting controls for exterior lighting installed. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.3 [EL4]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.3 [EL19]3 Fluorescent luminaires with odd numbered lamp configurations that are within 10 feet center to center (if recess mounted) or are within 1 foot edge to edge (if pendant or surface mounted) shall be tandem wired. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.4 [EL6]1 Exit signs do not exceed 5 watts per face. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Chuy's Y:\_Projects\Active\2018\01201828.31\01201828.31.Calcs and Support\182831 COMCHECK.cck 10/22/18Report date: 85 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.6 [EL24]1 Exterior grounds lighting over 100 W provides >60 lm/W unless on motion sensor or fixture is exempt from scope of code or from external LPD. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.3 [EL8]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Chuy's Y:\_Projects\Active\2018\01201828.31\01201828.31.Calcs and Support\182831 COMCHECK.cck 10/22/18Report date: 86 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C408.2.5. 1 [FI16]3 Furnished as-built drawings for electric power systems within 30 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.3, C408.2.5. 2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.5.2 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. C405.6.2 [FI19]1 Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. C408.3 [FI33]1 Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.3 [FI48]1 Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Chuy's Y:\_Projects\Active\2018\01201828.31\01201828.31.Calcs and Support\182831 COMCHECK.cck 10/22/18Report date: 87 ofPage Project Title: Data filename: Chuy's Y:\_Projects\Active\2018\01201828.31\01201828.31.Calcs and Support\182831 COMCHECK.cck 10/22/18Report date: 88 ofPage